You are on page 1of 1

HY-8 Analysis Results

Customized Table
Culvert Crossing: “CREACIÒN Y MEJORAMIENTO DEL CAMINO VECINAL
Total CHILCAPUQUIO
Culvert – YACUY
Headwate Inlet SONCCO,
Outlet DISTRITO DE
Flow Type Crest Face Throat Tailwater
ACORIA-HUANCAVELICA-HUANCAVELICA"
Discharge Discharge r Control Control Control Control Control Elevation
(cms) (cms) Elevation Depth(m) Depth(m) Elev(m) Elev(m) Elev(m) (m)
(m)
0.00 0.00 3196.13 0.00 0.0 0-NF 0.00 3196.13 0.00 3196.00
0.10 0.10 3196.39 0.26 0.05 1-S2n 0.00 0.00 0.00 3196.09
0.20 0.20 3196.51 0.37 0.13 1-S2n 0.00 0.00 0.00 3196.13
0.30 0.30 3196.60 0.46 0.21 1-S2n 0.00 0.00 0.00 3196.17
0.40 0.40 3196.68 0.55 0.28 1-S2n 0.00 0.00 0.00 3196.20
0.50 0.50 3196.76 0.63 0.36 1-S2n 0.00 0.00 0.00 3196.22
0.60 0.60 3196.83 0.70 0.43 1-S2n 0.00 0.00 0.00 3196.25
0.60 0.60 3196.83 0.70 0.43 1-S2n 0.00 0.00 0.00 3196.25
0.80 0.80 3196.99 0.85 0.59 1-S2n 0.00 0.00 0.00 3196.30
0.90 0.90 3197.07 0.93 0.68 5-S2n 0.00 0.00 0.00 3196.32
1.00 1.00 3197.15 1.02 0.77 5-S2n 0.00 0.00 0.00 3196.34