You are on page 1of 4

CEVERON alpha ®

CEVERON® alpha is the most flexible automated


hemostasis & thrombosis research tool on the market.
Clotting Chromogenic

Tu r b i d i m e t r i c F l u o r o m e t r i c*

800.526.5224
info@diapharma.com

RESEARCH USE ONLY IN THE US AND CANADA *optional


CEVERON alpha®

S O F T WA R E F E AT U R E S

V E R S AT I L I T Y
• Create custom protocols
• Personalized test menu
• Can export results and analyze
data as desired

U S E R - F R I E N D LY C A L I B R AT I O N G R A P H S
• Windows®-based software • With all relevant parameters
• Detailed information for each sample, • Comparison of calibration curves
test, period and reaction curve possible

USER MANAGEMENT QUALITY CONTROL


• User identification and tracking • Complete quality control monitoring
• Secure access through programmable • User-defined QC limits and Westgard
user levels method
• Statistics and graphics
W E B - B A S E D U P D AT E S
REAGENT HANDLING
Ceveron alpha user platform:
• Updates for Technoclone reagents Reagent Data Management:
• Software updates • User-defined test and reagent profiles
• Automatic alert • Reagent monitoring of volume and
• Service check on-board stability
CEVERON alpha ®

A N A LY Z E R F E A T U R E S

G E N E R A L F E AT U R E S R E A G E N T F E AT U R E S
• Open programming • 14 cooled positions
• High precision and flexibility • 4 of them stirred
• Fast and easy • 4 positions at RT
• Fully automated walk-away system • Preheated pipetting needle
• Many programmable applications • Reagent liquid-level sensing
• Bidirectional interface • Barcoded Technoclone reagents
• Limited instrument maintenance • Complete reagent management (name,
batch, stability, expiry date, volume)
MEASUREMENT
F E AT U R E S S A M P L E F E AT U R E S
• Simultaneous measurement of • Integrated barcode identification
clotting, chromogenic and for samples
turbidimetric test possible • All tube sizes accepted
• 24/7 continuous operation • Automatic dilution and re-dilution
• Fluorescence measurement • Complete traceability of samples
possible (optional)
• Reflex anytime possible UNIQUENESS
• Approximately 100 PT results/hour -
• Fluorescence measurement
depending on test protocol
possible (optional)
• Compact format
• Extremely quiet
• Automatic self-check
• Transparent shield

T G A M O D U L E F E AT U R E S ( O P T I O N A L )
Fluorescence measurement for TECHNOTHROMBIN® TGA

• TECHNOTHROMBIN® TGA - a thrombin generation assay (TGA) based on monitoring the


formation of thrombin by means of a fluorogenic substrate upon activation of the coagulation
cascade by tissue factor
Module - a special adapted TGA module with 4 channels is placed laterally in the
• Fluorogenic
tempered cuvette rotor, with a UV emitter (360 nm) placed in the module, thrombin generation
can be measured
• Calibration Curve - fully automated calibration curve is created
• Measurement Monitoring - TGA monitoring of each sample during measurement possible
- results are automatically calculated and displayed in Lag Time (Lag), Time to Peak
• Results
(tPeak), Peak Thrombin (Peak), Velocity Index (VI) and Area Under the Curve (AUC)

800.526.5224 info@diapharma.com
RESEARCH USE ONLY IN THE US AND CANADA • ML-00-00057REV03
CEVERON alpha ®

S P E C I F I C AT I O N S

Test Menu Clotting, chromogenic, turbidimetric and fluorogenic assays

• 4 channels with 4 wavelengths


Wavelengths: 405, 570, 630, 740 nm
Measuring Unit • 4 channels with fluorogenic wavelength
Excitation wavelength: 360 nm, Emission wavelength: 430 nm

Samples On Board 24 + 12 for Ceveron® sample cups

Reagents On Board 14 cooled, 4 room temperature, 8 buffers and diluents

Cuvettes On Board 84 (7 x 12 racks)

Tests Per Sample 36

Sample Volume 5 - 400 μL

Reagent Volume 5 - 400 μL

Reflex Testing Yes, configurable

Sample Data Storage Unlimited

Dimensions (analyzer) 29.5" x 26.6" x 16.5" (w x d x h) with height 30" when cover open

Weight 40 kg (88 lb)

F E AT U R E S CLOTTING TESTS CHROMOGENIC


TESTS
• Sample barcode reader PT
• Reagent barcode reader aPTT FVIII:C
Fibrinogen C1-Inhibitor
• Barcoded Technoclone reagents
Thrombin time Protein C
• Sample level sensor Extrinsic coagulation factors Antithrombin
• Reagent level sensor Intrinsic coagulation factors Plasminogen
• Sample predilution Lupus tests Antiplasmin
FVIII inhibitor anti-Xa
• Calibration curve predilution Protein C UFH, LMWH, Orgaran
• Reaction curve availability Protein S Arixtra, Rivaroxaban
• Security system APCR Apixaban
• Continuous
Direct thrombin inhibitors
operation
Calibrators TURBIDIMETRIC
• Bidirectional interface Quality controls TESTS
• Host query function
• Events log system D-Dimer
FLUOROMETRIC
vWF
• Automatic repeats TESTS
• Automatic re-dilution Thrombin generation

800.526.5224 info@diapharma.com
RESEARCH USE ONLY IN THE US AND CANADA • ML-00-00057REV03

You might also like