You are on page 1of 2

100 kW CHP

Microturbine
Elliott Energy Systems, Inc. has been Main Features: Compressor
designing and supplying microturbines Rated Power Output The compressor is a rugged
Electrical 100 kW @ 0.8PF stainless steel radial flow design.
since 1997. Our experience has made us at 59ºF/ 15ºC, Sea Level The approximate pressure ratio
a leader in microturbine technology. Thermal 172 kW/ 587,000 BTU/ hr is 4 to 1.
Located in Stuart, Florida, USA, Elliott Noise Outdoor <62 dBA @ 10 m
Energy is a wholly owned subsidiary of Indoor <75 dBA @ 1 m Combustor
Ebara Corporation of Tokyo, Japan. Electrical Data Combustor is designed with the
Parallel Ready aid of advanced computational
Ebara values contributing to society by Voltage Output 400/ 480 VAC fluid dynamics capabilities and
providing superior technologies and Amps 200 Max precision tested with high
services related to power, energy, water, Frequency 50/ 60 Hz accuracy flow systems to provide
air, and environment. Ebara Corporation Output Circuit 4-Wire Wye reliable starting, robust operation
has been supplying industrial equipment Operating Mode Island & Grid Connect) during onload/ offload, extended
life, and low NOx and CO over
and solutions for over 90 years. Elliott Standard Equipment: the entire operating range.
Energy benefits from Ebara’s experience ■ Integral Gas Compressor
and large knowledge base, which has ■ Integral Heat Recovery Unit High Speed Alternator
enabled the development of products like (Stainless Tube & Copper Fin) The electric power is generated
■ Remote Interface through a 4 pole, permanent
the one presented here. RS485/ Modbus magnet alternator rotating within
■ Automatic Voltage Regulation an oil cooled stator assembly.
The TA100 CHP is packaged as an ■ Battery Charger The stator assembly is energized
efficient combined heat and power (CHP) ■ Single Stage Dry Type Air Filter as a motor during initial start-up
genset. Our Microturbine CHP system is ■ Corrosion Resistant Hardware reducing the need for auxiliary
■ Digital LCD Touch Panel starting hardware.
capable of producing 100kW of electrical ■ System Protection Including:
energy and 172kW of thermal power per ❒ Under and Over Voltage Turbine
hour. Cogeneration usage can consist of ❒ Under and Over Frequency The radial super-alloy turbine
hot water, absorption chiller or drying ❒ Over Current, Over Temperature provides design margin and long
system applications. Depending upon the ■ Optional Outdoor Kit (NEMA 3R, IP 44) life capability to provide energy
■ Battery Start to drive both the compressor
user application, overall total thermal ■ CE Certified alternator.
efficiency could be greater than 75%.
Heat Exchanger
The heat exchanger is an air to
liquid tube and fin counter
current flow design, fired by the
exhaust gas. The tube and fin
materials have been selected to
provide long life, maximum
thermal energy recovery and
allows for potable water
applications. The outlet liquid
temperature is dependent upon
inlet liquid temperature and liquid
flow.

Power Electronics
The output from the alternator is
converted into 480 or 400 VAC,
60 or 50 Hz, depending upon the
needs of the end-user.

Control System
The control system provides
automatic control of the CHP
System, Turbine and Engine
protection features as well as
complete control of engine,
starting, speed, safety systems ,
and outside communications.

* Photo is shown without intake hood and exhaust flange.

©2005 by Elliott Energy Systems, Inc. All Rights Reserved EESI #51 Rev. 1
TA100 CHP Specifications
Performance: Emissions, Natural Gas (Typical)
Electrical Output CO: 25 PPM @ 15% O2
Output (@ ISO) 100 kW net 15 PPM Volume
105 kW gross 32.9 mg/MJ
Maximum Block Loading 100% 31.7 mg/m3@ 15% O2
Minimum Load 0kW 1.00 lbs/ MWhr
Efficiency* 29% (+/- 1) LHV 0.315 grams /bhp hr
THD < 3% 0.077 lbs /MMBTU
Voltage Regulation +/- 2% NOx: 24 PPM @ 15% O2
Fuel Consumption (ISO Rated 14 PPM Volume
Power) 52.6 mg/MJ
Natural Gas: 22 SCFM/ 50 mg/m3@ 15% O2
0.62 m3/min 1.60 lbs/ MWhr DIGITAL LCD
0.504 grams /bhp hr TOUCH PANEL
(940 BTU/ SCF)
362 kW (@ 1,235,000 Btu/ hr.) LHV 0.122 lbs /MMBTU 88.7 KEY SWITCH
2.25 m EMERGENCY
Heat Rate 12,355 BTU/ kWh 76.5
Exhaust Gas Temperature 1.94 m STOP
Thermal Output (Hot water) Heat Recovery Mode 180ºF/
172 kW / 587,000 Btu/ hr. 82ºC
Water Inlet Temp 120ºF / 49ºC Full HRU Bypass 560ºF/ 293ºC
Water Outlet Temp 140ºF / 60ºC
Flow 60 GPM/ 3.8 L/s Batteries 24VDC min.
Total System Efficiency* >75% Two 12 volt, Group 27, lead acid,
* Not Including Gas Compressor maintenance free - 105Ah nominal
33.5
Engine Total Weight with Enclosure: 0.85 m
FRONT VIEW
Manufacturer Elliott Energy Indoor: 4,100 lb./ 1,860 kg
Systems Outdoor: 4,500 lb./ 2,040 kg
Model TA-100 CHP
Type Recuperated Gas Turbine
Pressure Ratio 4 to 1

Cooling System ENGINE AIR INLET COOLING AIR INLET


Alternator Oil Cooled ENGINE EXHAUST STACK 64.9
Power Electronics Air Cooled 1.65m

Enclosure 2,400 CFM/ 1.13 m3/s


EXHAUST
Exhaust System
Outlet Size 10” Diameter
Max. Back Pressure 5” water column
1.2 kPa
Exhaust Gas Flow 1,700 SCFM
0.80 Nm3/s
Fuel 76.1
1.93 m
Fuel Type Natural Gas
Pressure Required 0.5 - 5 PSIG
3.4 - 34.5 kPa
Oil System 39.8
1.01 m
Oil Type Mobil SHC 824 POWER
2" FNPT HUB
Capacity 5 US gal. (19 L) RIGID
Oil Filter Spin On Type, 3 Micron 9.3
236.22 mm

3.0 SUPPLY 4.4 FORK LIFT POINTS 16.0 3.0


2" MNPT 111.76 mm 406.4 mm 76.2 mm
WATER 63.8
ENCLOSURE 1.62 m 2.5
EXHAUST 2" FNPT 97.8 63.5 mm
2.48 m 2.0
WATER 103.9 50.8 mm
2" FNPT 2.64 m
111.7
ERGY SYST WATER 2.84 m
EN E
T 1/2" MNPT 120.0
M
OT

S,

3.1 m
ELLI

INC.

128.1
3.25 m LEFT SIDE VIEW
40
IS

O
90 17
01 A1
For more information please contact: 2901 S.E. Monroe St.
Elliott Energy Systems, Inc. Stuart, FL 34997 USA
Sales & Marketing Tel:772-219-9449
ees.sales@elliottmicroturbines.com Fax:772-219-9448
Website: www.elliottmicroturbines.com
The specifications in this catalogue are subject to change without prior notice.

©2005 by Elliott Energy Systems, Inc. All Rights Reserved EESI #51 Rev. 1