You are on page 1of 3

F3

Door lock
3 2 1

E1 3 2 1
Heater 1
1

1 2 3

X1
The reproduction, transmission or use of this document or its contents is not permitted express written authority.

43 4 1 2 3
23 3
iS L
og

12 2
1 1
L L’
by patent grant or registration of a utility model or design are reserved. Copyright reserved.

X16 N
3 3
2 2
1 1 K41
Offenders will be liable for damages. All rights including rights created

X15 2 2 N
1 1 8 8 1 1 L
2
3
2
3
7
6
7
6 X3 K2
4 4 5 5
5
6
5
6
4
3
4
3 N N L
K6 K7
7 7 2 2
8 8 1 1
X22 X21 K39 Q4 7 7 1 1

N N N
N
6 6 2 2
K64 K23 5 5 3 3

Operating + display Power module K38 K40 K37 1 2


K35

X0
4 4 4 4
M

θ
module 3 3 5 5
~
1 2 2 2 6 6
GND

GND

G
Data

K5
+5V

L L’ L’ L’ L’ 1 1 7 7

X4 8
1 2 3 1 2 3 1 3 1 3 5 1 3 1 3
X2 M 2
X8

X6

X7

X5
X10

X12

1 2 3 1 2 3 1 3 1 3 5 1 3 1 3
Motor-wash/spin

2 1 2 1

2 1 2 1
3 2 1 L
2 1 3 1

3 1 θ
3 2 1
3 1
PE
3 1 f 2 1
M
Xx.x
p ➀ F20 ~
B19 N

Temperature Switch-aqua N
B14 stop
sensor (washing) θ
Pressure sensor 5 3 1 M3 R2
➀ K67 Pump
(frequency) 5 3 1 Interference filter
Valve (warm
iS L Customer service interface K46 water or aqua Only in Variants with PTC-Door lock
og

Valve (main wash) stop) Designation: LCS Document No.: Rev.: Sheet-No.:

➀ only for warmwater / Aqua Stop variants Interconnection Diagram 1


–––/∗ Not included in all variants
K47 EN 5500 0000 068374 D of:
3
Valve (pre wash) F03/F11/F13/F15/S16/S18-1&2 Material No.:
9000 665002 12.09.2014

behnke
F3
Door lock
S11
∗B30
Load/unbalance S12
sensor (3D/3G) 3 2 1

H E1
s Heater 1
3 2 1
1
3 2 1

3 2 1

1 2 3

X1
The reproduction, transmission or use of this document or its contents is not permitted express written authority.

43 4 1 2 3
23 3
iS L
og

12 2
1 1
L L’
by patent grant or registration of a utility model or design are reserved. Copyright reserved.

X16 N
3 3
2 2
1 1 K41
Offenders will be liable for damages. All rights including rights created

X15 2 2 N
1 1 8 8 1 1 L
2
3
2
3
7
6
7
6 X3 K2
4 4 5 5
5
6
5
6
4
3
4
3 N N L
K6 K7
7 7 2 2
8 8 1 1
X22 X21 K39 Q4 7 7 1 1

N N N
N
6 6 2 2
K64 K23 5 5 3 3

Operating + display Power module K38 K40 K37 1 2


K35

X0
4 4 4 4
M

θ
module 3 3 5 5
~
1 2 2 2 6 6
GND

GND

G
Data

K5
+5V

L L’ L’ L’ L’ 1 1 7 7

X4 8
1 2 3 1 2 3 1 3 1 3 5 1 3 1 3
X2 M 2
X8

X6

X7

X5
X10

X12

1 2 3 1 2 3 1 3 1 3 5 1 3 1 3
Motor-wash/spin

2 1 2 1

2 1 2 1
3 2 1 L
2 1 3 1

3 1 θ
3 2 1
3 1
PE
3 1 f 2 1
M
Xx.x
p ➀ F20 ~
B19 N

Temperature Switch-aqua N
B14 stop
sensor (washing) θ
Pressure sensor 5 3 1 M3 R2
➀ K67 Pump
(frequency) 5 3 1 Interference filter
Valve (warm
iS L Customer service interface K46 water or aqua Only in Variants with magnetic door lock
og

Valve (main wash) stop) Designation: LCS Document No.: Rev.: Sheet-No.:

➀ only for warmwater / Aqua Stop variants Interconnection Diagram 2


–––/∗ Not included in all variants
K47 EN 5500 0000 068374 D of:
3
Valve (pre wash) F03/F11/F13/F15/S16/S18-1&2 Material No.:
9000 665002 12.09.2014

behnke
F3
Door lock
S11
∗B30
Load/unbalance S12
sensor (3D/3G) 3 2 1

H E1
s Heater 1
3 2 1
1
3 2 1

3 2 1

1 2 3

X1
The reproduction, transmission or use of this document or its contents is not permitted express written authority.

43 4 1 2 3
23 3
iS L
og

12 2
1 1
L L’
by patent grant or registration of a utility model or design are reserved. Copyright reserved.

X16 N
3 3
2 2
1 1 K41
Offenders will be liable for damages. All rights including rights created

X15 2 2 N
1 1 8 8 1 1 L
2
3
2
3
7
6
7
6 X3 K2
4 4 5 5
5
6
5
6
4
3
4
3 N N L
K6 K7
7 7 2 2
8 8 1 1
X22 X21 K39 Q4 7 7 1 1

N N N
N
6 6 2 2
K64 K23 5 5 3 3

Operating + display Power module K38 K40 K37 1 2


K35

X0
4 4 4 4
M

θ
module 3 3 5 5
~
1 2 2 2 6 6
GND

GND

G
Data

K5
+5V

L L’ L’ L’ L’ 1 1 7 7

X4 8
1 2 3 1 2 3 1 3 1 3 5 1 3 1 3
X2 M 2
X8

X6

X7

X5
X10

X12

1 2 3 1 2 3 1 3 1 3 5 1 3 1 3
Motor-wash/spin

2 1 2 1

2 1 2 1
3 2 1 L

3 1 θ
3 2 1
PE
3 1 f M
Xx.x
p ~
B19
7 6 5 4 3 2 1
Temperature B14 N
sensor (washing) θ
Pressure sensor
7 6 5 4 3 2 1 M3 R2
(frequency) K47 Pump Interference filter
Valve (pre wash) K61
Valve (warm Only in Variants with magnetic door lock
K46 Designation: LCS Document No.: Rev.: Sheet-No.:
iS L Customer service interface Valve (main wash) water)
og

Interconnection Diagram EN 5500 0000 068374 D


3
–––/∗ Not included in all variants of:
3
F03/F11/F13/F15/S16/S18-1&2 Material No.:
9000 665002 12.09.2014

behnke

You might also like