The document provides a table listing occupancy types and their corresponding occupant load factors and exit capacity factors. The occupant load factor is the minimum area per person required for each occupancy type. The exit capacity factors specify the minimum width required per person for stairways and ramps serving each occupancy. The table includes occupancy types such as assembly, business, educational, healthcare, residential, commercial, storage, industrial, parking, and animal housing.
The document provides a table listing occupancy types and their corresponding occupant load factors and exit capacity factors. The occupant load factor is the minimum area per person required for each occupancy type. The exit capacity factors specify the minimum width required per person for stairways and ramps serving each occupancy. The table includes occupancy types such as assembly, business, educational, healthcare, residential, commercial, storage, industrial, parking, and animal housing.
The document provides a table listing occupancy types and their corresponding occupant load factors and exit capacity factors. The occupant load factor is the minimum area per person required for each occupancy type. The exit capacity factors specify the minimum width required per person for stairways and ramps serving each occupancy. The table includes occupancy types such as assembly, business, educational, healthcare, residential, commercial, storage, industrial, parking, and animal housing.
FACTOR WIDTH WIDTH PER PERSON PER PERSON PER PERSON 1. ASSEMBLY, GROUP A,B,C.
i. Concentrated (Ballroom, Dance 0.65 m2, net 7.6 mm 5 mm
floor, Prayer rooms etc.) 0.9 m2, net for prayer rooms ii. Less Concentrated, Outdoors etc. 1.4 m2, net 7.6 mm 5 mm (Meeting rooms, Restaurant, Out- doors etc.) iii. Bench Seatings, 455 mm linear 7.6 mm 5 mm iv. Fixed Seatings Number of fixed seats 7.6 mm 5 mm 2 v. Waiting Spaces in theaters, similar 0.28 m 7.6 mm 5 mm spaces vi. Kitchens 9.3 m2 7.6 mm 5 mm 2 vii. Library Stacks area 9.3 m 7.6 mm 5 mm 2 viii. Library Reading rooms 4.6 m , net 7.6 mm 5 mm ix. Swimming Pool 4.6 m2 Water surface 7.6 mm 5 mm x. Swimming Pool Decks 2.8 m2 7.6 mm 5 mm 2 xi. Exercise Room with Equipment 4.6 m 7.6 mm 5 mm 2 xii. Exercise Room without Equipment 1.4 m 7.6 mm 5 mm xiii. Stages 1.4, net 7.6 mm 5 mm xiv. Lighting and Access Catwalks 9.3, net 7.6 mm 5 mm 2 xv. Casinos and Gaming areas 1m 7.6 mm 5 mm xvi. Skating Rinks 4.6 m2 7.6 mm 5 mm xvii. Food Court Seating areas 1.4 m2 7.6 mm 5 mm 2 xviii. Airport Concourse 9.3 m 7.6 mm 5 mm 2 xix. Airport Waiting areas 1.4 m 7.6 mm 5 mm xx. Airport Baggage Claim 1.9 m2 7.6 mm 5 mm 2 xxi. Airport Baggage Handling 27.9 m 7.6 mm 5 mm xxii. Theater-Type Seating Number of fixed seats 7.6 AB 5.6 C See Table See Table 1.17.3. 1.17.3. xxiii. Museum 5.0 m2 7.6 mm 5 mm 2. BUSINESS, GROUP A,B,C.
i. Regular Office areas 9.3 m2 7.6 mm 5 mm
2 ii. Concentrated Office areas 4.6 m 7.6 mm 5 mm iii. Air Traffic Control observation levels 3.7 m2 7.6 mm 5 mm 3. EDUCATIONAL , GROUP A,B,C.
i. Classroom 1.9, net 7.6 mm 5 mm
i. Shops, Laboratories, Vocational etc. 4.6, net 7.6 mm 5 mm | CDGH-OP-25 | September 2018 Page 285 of 1348 Table 3.13.: Occupant Load Factors and Exit Capacity Factors
OCCUPANCY OCCUPANT LOAD STAIR RAMP
FACTOR CAPACITY CAPACITY PER PERSON PER PERSON PER PERSON 4. HEALTHCARE GROUP A,B
i. Inpatient treatment departments 22.3 m2 7.6 mm 5 mm
2 ii. Sleeping departments 11.1 m 7.6 mm 5 mm 2 iii. Consultation departments 9.3 m 7.6 mm 5 mm 2 iv. Clinics 9.3 m 7.6 mm 5 mm 2 v. Limited Care 9.3 m 7.6 mm 5 mm 2 vi. Both sides of Smoke Compartment 2.8 m , net 7.6 mm 5 mm 5. HEALTHCARE GROUP C
i. Ambulatory Health care 13 m2 7.6 mm 5 mm
6. RESIDENTIAL GROUP A
i. Apartments 18.6 m2 7.6 mm 5 mm
7. RESIDENTIAL GROUP B, C
i. Staff Accommodation, Hostels 18.6 m2 7.6 mm 5 mm
i. Labor Accommodation 18.6 m2 7.6 mm 5 mm 8. PRIVATE VILLA None None None 9. COMMERCIAL VILLA None None None 10. DETENTION , GROUP A,B,C. 11.1 m2 7.6 mm 5 mm 11. HOTEL
i. Hotel Apartments 18.6 m2 7.6 mm 5 mm
i. Hotel Guest rooms 18.6 m2 7.6 mm 5 mm 12. DAY CARE, GROUP A,B 3.3 m2 , net 10 mm 5 mm 13. MERCANTILE, GROUP A,B,C.
i. Sales area on floor below street floor 2.8 m2 7.6 mm 5 mm
ii. Sales area on street floor 2.8 m2 7.6 mm 5 mm iii. Sales area on floors above street floor 5.6 m2 7.6 mm 5 mm iv. Sales area on two or more street floors 3.7 m2 7.6 mm 5 mm v. Floors used only for offices 9.3 m2 7.6 mm 5 mm vi. Floors used for goods and not public 27.9 m2 7.6 mm 5 mm
| CDGH-OP-25 | September 2018 Page 286 of 1348
Table 3.13.: Occupant Load Factors and Exit Capacity Factors
OCCUPANCY OCCUPANT LOAD STAIR RAMP
FACTOR CAPACITY CAPACITY PER PERSON PER PERSON PER PERSON 14. MALL, GROUP A,B
i. Mall gross leasable area less than 2.8 m2 7.6 mm 5 mm
14,000 m2 ii. Mall gross leasable area of 14,000 m2 3.3 m2 7.6 mm 5 mm iii. Increment of every 1,290 m2 (Approx.) 0.1 m2 added to 3.3 m2 7.6 mm 5 mm Max 5.1 m2 15. STORAGE, GROUP A
i. High Hazard Storage 27.9 m2 18 mm 10 mm
16. STORAGE, GROUP B,C.
i. Low and Ordinary Hazard Storage 27.9 m2 7.6 mm 5 mm
17. INDUSTRIAL, GROUP A
i. High Hazard content 9.3 m2 18 mm 10 mm
18. INDUSTRIAL, GROUP B,C.
i. General, Low Hazard 9.3 m2 7.6 mm 5 mm
ii. Special Purpose NA 7.6 mm 5 mm 19. PARKING, GROUP A,B
i. Enclosed parkings 27.9 m2 7.6 mm 5 mm
ii. Open parkings 27.9 m2 7.6 mm 5 mm 20. PARKING, GROUP C
i. Mechanical/Robotic parkings 46.5 m2 7.6 mm 5 mm
21. ANIMAL HOUSING, GROUP A,B,C. 11.1 m2 7.6 mm 5 mm