FEATURES: 20 Selectable Sampling Rates — lets you display signals in a wide variety of waveforms, from a small fraction of a waveform to multiple waveforms of the measured signal Selectable Input Voltage Ranges — lets you select the range of the measured signal for the most accurate readings. le Trigger Sources — lets you select whether the oscilloscope starts a measurement using an internal or an external trigger. Acquisition Modes — lets you automatically setting the trigger (AUTO), or triggering on an explicit trigger event (NORMAL), continuously or on a single event (SINGLE). Pre- and Post Trigger — lets you visualize the measured signal before and/or behind the trigger event. The Trigger position can be set anywhere within the memory depth. Selectable Trigger Levels — lets you select an individual signal trigger level anywhere within the grid (vertically), and either on negative or positive signal transition. Selectable Zero Levels — lets you select an line position anywhere within the grid (vertically). Selectable Input Coupling — lets you select whether the signal to be measured is DC or AC coupled to the scope. idual zero Do not use unapproved attachments. Do not allow anything to rest on the USB cable, when, attached to the Key-Scape. Do not locate the USB cable where people might walk on the cable. If your Key-Scope doesn't operate normally, in particular if any unusual sounds or smells come from it, immediately unplug it and contact your local distributor, Donot attempt to service the Key-Scope yourself; opening or removing the cover can expose you to dangerous voltage or other hazards. Unplug the Key-Scope and refer servicing to qualified service personnel under the following conditions: — Ifthe Key-Scope has been exposed to rain or water — Ifthe Key-Scope does not operate normally and you are following the operating instructions — Ifthe Key-Scope has been dropped or damaged — Ifthe Key-Scope exhibits a distinct change in performance This Key-Scope is fully calibrated and tested. Under normal Use, no further internal adjustment should be necessary. Adjust only those controls covered by the operating instructions. B ®O Wittig Improper adjustment of other controls might result in damage and might require extensive work by a qualified technician to restore the Key-Scope to normal operation. If the Key-Scope should require repait,do not try to repairit yourself. Take it to your distributor. OWNER'S MANUAL Please read before using this equipment Key-Scope V1.0 Mey eile rle-) First English Edition Al Rights Reserved © 2012 Wittig srl Italy. Key-Scope is a trademark used by Wittig sr. Key-Scope made in Italy Made in Italy GETTING STARTED SAFETY INSTRUCTIONS The Key-Scope is a microprocessor-controlled digital storage oscilloscope in a small keyring-type housing with a backlit mini color Liquid Crystal Display (LCD). All oscilloscope parameters ‘are menu-driven and selected by pressing one of the push buttons. You can quickly and single-handedly set all parameters while looking at the point of measurement, the scope's controls, and the display. This eliminates the need for any head movement, making the Key-Scope the easiest-to-use measurement tool available. It is battery powered and can be connected to the PC via the supplied USB cable. The most updated windows application software and the latest firmware update are available for free download on our website at wowitigit Read all of these instructions carefully, and save them for your reference. Tip Slider press to unlock then slide Connect USB cable for PC access and torecharge battery Warning: Use extreme caution in the use of this device. Improper use of this device can result in injury or death. Follow all the safeguards suggested in this owner's manual in addition to normal safety precautions in dealing with electrical circuits. Do not use this device if you are unfamiliar with electrical circuits and testing procedures. ‘Not for commercial or industrial use. This oscilloscope is designed to ensure the safest operation possible. However, safe operation depends on you, the operator. Make sure you follow these simple safety rules: + Readall of these instructions carefully, and save them for your reference. + Followall warnings and instructions marked on the Key-Scope and mentioned in the PC Application. + When making voltage measurements, never touch the Key-Scope' tip ora hot wire in AC wiring circuits. Ifyou do, you could receive an electric shock a 2 Never apply the Key-Scope to a source of power greater than 42V AC peak-to-peak or 60V DC. Doing so could cause electrical shock or damage to the Key-Scope. Caution: f you do not know the level of the voltage to ‘measure always start at the highest range: 5V/div Never try to measure any voltage more than 42 VAC on a DC source bias. Doing so might damage your Key-Scope. Always discharge filter capacitors in the circuit under test, before you attach the Key-Scope.If the Key-Scope touches an undischarged capacitor, it could damage it. f you touch an undischarged capacitor, you could receive an electric shock Because many AC-DC sets have a potentially hot chassis, be sure the top of your workbench and the floor underneath it are made of nonconductive materials Unplug the Key-Scope before cleaning it.o not use liquid of aerosol cleaners. Use a damp cloth for cleaning and then wipe it dry immediately. Do not use the Key-Scope near water (for example, bathtub, washbow kitchen sink, laundry tub, wet basement or swimming pool) AUXiliary Port — lets you connect an external source or used as signal generator output. Auto Measurements — lets you measure automatically either numerical voltages Vpp (Volt peak-to-peak) or frequencies. Battery Powered — lets you recharge the battery via the supplied USB cable, when connected toa PC. Color Display — lets you visualize measured signals and control parameters in color. The backlight can be set in different modes. Also define your individual and preferred color settings. PC Application — lets you connect the Key-Scope to a PC via the USB to visualize measured signals on a big PC screen, print and save, and fully control parameters remotely. World-Smallest Oscilloscope — lets you carty your personal oscilloscope anywhere along with you attached to your keyring. igger MAIN SCREEN TIMEBASE | [INPUT VOLTAGE ‘AUX PORT, FUNCTION INDICATOR PRE-/POST POSITION (TRIGGER LEVEL) TRANSITION INDICATOR ZERO LINE MEASURED SIGNAL TRIGGER -/— [RSoeiaie NERY ACAUTES [ACQUISITION MODE, CONPLING |\ (GSE CONNECT) pwittio 32 v ‘AUTOMATIC MEASUREMENT GRID Press (@ (Cursor Control knob) vertically or 44> toselect menu item, PC Interface via USB, remote control, many additional features, via download available, USB cable included Dimensions Tamm x 40mm x 17mm Weight 509 Operation Environment 0" t040°C Certifications ce EN 61326 + EN61000+ Country of Origin Developed and manufactured in Europe, Italy Warranty 2years Specifications are typical;individual units might vary. Specifications are subject to change and improvement without notice. = CARE AND MAINTENANCE Your Key-Scope is an example of superior design and craftsmanship. The following suggestions will help you care for the Key-Scope so you can enjoy it for years im AN) Keep the Key-Scope dry. IFit gets wet, wipe it dry immediately. Liquids might contain minerals that can corrode the electronic circt Handle the Key-Scope gently and carefully. Dropping it can damage circuit boards and cases and can cause the Key-Scope to work improperly. Use and store the Key-Scope only in normal temperature environments.Temperature extremes can shorten the life of electronic devices and distort or melt plastic parts. Keep the Key-Scope away from dust and dirt, which can cause premature wear of parts. Wipe the Key-Scope with a damp cloth occasionally to keep it looking new.Do not use harsh chemicals, cleaning solvents, or strong detergents to clean the Key-Scope. Modifying or tampering with the Key-Scope’ internal com- ponents can cause a malfunction and might invalidate your Key-Scope’s warranty and void the CE authorization to use it. 20 OWOO Selector AC-DC Coupling) (Backlit Color LCD) ‘START/STOP/SINGLE Press and hold for 3sec to switch ON AUX Port External Trigger or Signal Output Software selectable} Ure) ‘Measurement Tip access over slider ‘on housing backside Software Cursor Control EEA use supplied Ground cable with clip Shipment Contents + keyring-type Oscilloscope in blister package + Ground & Ausiliary Cable with Clip,and USB Cable + Short instructions & Manual (multilingual available on request). 5 ESTE) PR Tous Press (@)) vertically until to reach upper menu bar with Input Voltage Menu selected (see selection previous page). When Voltage Menu selected, press + (Ul) to reach Acquisition Mode Menu (see selection above). When Acquisition Mode Menu is selected, press (1) +4 to change Acquisition Mode. When in upper menu bar, press + (@) + to reach Timebase Menu or Input Voltage Menu. ‘Automatic Triggering. In this mode, Key-Scope tries to find a trigger event automatically, according to the Trigger Level and Trigger Transition Settings. Ifno trigger event is found, Key-Scope switches into free run mode and displays the measured signal ass. Note: AUTO is not available in SINGLE mode Normal Triggering, In this mode, Key-Scope is waiting until an explicit trigger event occurs, according to the Trigger Level and Transition Settings. Press and hold ({) for 2sec to jump to Acquisition Mode Selection at any time (Short-Key function), 8 POWER CONTROL AUTOOFF Automatically switch-offKey-Scope after min, if none ofthe control parameters has changed. Stay always switched-on, until battery is fully discharged. Automatically switch-off before lowest allowed battery voltage level is reached STAY ON Peed Enables the AUXiliary port to serve asa digital output. DISABLED AUXiliary port output disabled, Port serves as input channel for external triggering and more. KHZ ‘TkHz Square wave output signal, with fixed 50% duty cycle. JOKHZ kHz Square wave output signal with fixed 50% duty cycle OOKHZ —_100kHz Square wave output signal with ixed 50% duty cycle CUSTOM Square wave output signal with selectable frequency and duty cycle via PC Application BITPAT Repetitive serial bit pattern output signal (120bit string), with fixed 50% duty cycle Pre-defined via PC Application. Note: Also see PC Application Help fle for more detailed instructions on how to use additional PC enabled functions. v7 SPECIFICATION Real-time Sampling Rate Analog Bandwidth Timebase Settings ‘1 MSa/s 100 kHz 51s, 10s, 20s, 50s, 1001s, 200ps Sms, ims, 2ms,5ms, 10ms, 20ms 50ms, 100ms,200ms, 55 15,25, 55, 10s/div Input Voltage Selection Tomv, Somv,.V,.5V, 1V, V/div Input Impedance 1MOhm Maximum Input Voltage 42Vpp (peak-to-peak) Trigger Settings Level adjust, Transition, Pre/Post Acquisition Modes ‘AUTO, NORMAL, SINGLE, ROLL AUXiliary Port Cable with Clip included + External Trigger Mode input max.3.3V, #Transition + Signal Generator Mode Square Signal, frequency selectable Memory Depth 120 samples Input Coupling Switch AC or DC Display color 15", 130x 130 dots, backlit ON/OFF/AUTO, colors selectable Battery LiPo 3.7V, 200mAb (max. 4h duration) rechargeable via USB (upto 2h) battery indicator 18 vertically until to reach upper menu bar with Input Voltage Menu selected (see selection above). When selected, press (V1) +4 to change Input Voltage. When in upper menu bar, press «(il)» to reach Timebase Menu or Acquisition Mode Menu. Note: Trigger AUTO not available for timebase settings < SOys/dlv. Press (@) vertically until to reach upper menu bar with Input Voltage Menu selected (see selection on top). When Voltage Menu selected, press + (U) > to reach Timebase Menu (see selection above). When Timebase Menu selected, press ®t tochange Timebase (also see Roll Mode). When in upper menu bar, press +- (Vl) to reach Input Voltage ‘Menu or Acquisition Mode Menu. (era Use AC/DC switch to select the input coupling, The respective setting is indicated in the upper menu bar. When AC is selected, the DC portion of the measured signal is cut. A Sia wae 7 MENU OPTIONS aaa RE-/POST-TRIGGER POSITION Press (4) (vertically) repeatedly to reach Pre-/Post-Trigger Positioning (see selection above). When Trigger Positioning is selected, use+ () + to move the trigger position anywhere within the memory depth. Respect to the position of the trigger, the Pre-Trigger and Post-Trigger ratio is selectable individually. ‘TRIGGER LEVEL, + TRANSITION and SOURCE [R%me? Press (() (vertically) repeatedly to reach Trigger i Level (see selection on the left). When Trigger Level is selected, use () ¥4 to adjust the trigger level. Use «(Gj + to set the following options: Triggers when an internal signal is above this level and is rising edge. Triggers when an internal signal is below owi this level and is falling edge. Triggers when an external digital signal applied to AUXiliary port and is rising edge. Triggers when an external digital signal applied to AUXiliary port and is falling edge. 10 Press on (() _ (vertically) repeatedly to reach MENU. When in MENU use_ (@) 44> to move the cursor within this menu Presson ({) (vertically) to exit MENU. Move the Menu Cursor on an individual menu item. Use START/STOPISINGLE] to change an option. All settings are saved and will be retrieved on future sessions. Dee Se Selects the automatic measurement method in main screen to measure either voltages or frequencies automaticaly VOLTAGE Vpp oF Voc is displayed according to the AC/DC coupling selection. In DC coupling, an AC voltage is measured when the peak-to-peak voltage is bigger than half ofa grid division. Otherwise it measures DC voltages. In AC itis always measuring voltages peak-to-peak. FREQ SEC and FREQHZ Sec (us oF ms) or Hz (kHz or Hz) is displayed according to the selected option. Ifthe automatic measurement determines a valid signal transitions, the respective value is displayed automaticaly 15 DISPLAY ME! Selects various operating and display color options. BL (BACKLIGHT OPTIONS) on BLOFF Backlight always switched off 4h BLAUTO Backlight automatic control Backlight switched on high intensity when any control parameter changes. High intensity changes to normal intensity ater 10sec. Backlight switched off after Imin. 2eprex 3h BLON —_Backlightalways on with normal intensity ah BLON2 Backlight always on with high intensity th COLOR OPTIONS Move menu cursor on either SIGNAL (channel color), BACKGND (background color) or GRID (color). Select out of 16 individual colors for any menu color item. DEFAULT (COLORS) Reset all colors to default. 16 Press the [START/STOP/SINGLE] switch to enter SINGLE mode. When in SINGLE mode: Press this switch again to arm the trigger. Then the display is cleared and Key-Scope is waiting for a single trigger event, according to the Trigger Level and Trigger Transition Settings. [UME will appear to indicate this state. When a single trigger event occured, the measured signalis displayed and the indicator changes to ESRC Note: Repeat the proceedure above to re-arm the oscilloscope for further SINGLE SHOT events. Return to RUN MODE Press and hold this switch for 2sec to return to RUN mode. ‘AUTOMATIC MEASUREMENT Automatic measurement is available at all times, There are two options selectable. Either measuring automatically Voltages or Frequencies. Select this option in the MENU window (see MENU chapter) QwittigO. 120 If the timebase is set slower than 100ms/div, Key-Scope automatically switches in roll-mode. The signal acquisition starts at the actual selected tigger position. Press the |[START/STOP/SINGLE | switch to stop signal acquisition in roll-mode at any time. BATTERY GAUGE AND POWER ON/OFF ‘WEAITD) The Battery Gauge indicates the capacity of the battery. There are eight vertical bars representing ‘each a duration of approx. 30min of remaining power. The battery is recharged automatically when attached to a PC via the supplied USB cable. When the absolute minimum battery voltage is reached, the oscilloscope is switched off automatically. Never apply other power sources than USB supply voltages. POWER ON Press and hold the| START/STOP/SINGLE| switch for 3sec to switch ON the scope. POWER OFF Press and hold the [START/STOP/SINGLE switch for 3sec to switch OFF the scope. 2 Press again to continue the signal acquisition Press and hold the [STARTSTOP/SINGLE switch | for 2sec to re-start the signal acquisition at the trigger actual selected trigger position. No he display is cleared when re-started, Note: Internal Trigger is not available in roll-mode. If an external trigger is defined, the roll-mode starts and stops on the respective negative or positive selected signal transition applied to the AUXiliary port. B PC CONNECTION Use the supplied USB cable to connect the unit to a PC. The most updated PC Application is available for free download from our web site at www.wittigit. Also the latest version of the firmware is available there, To make a firmware update, please follow the PC Application’s help instructions. When connected to a PC, the acquisition signal is transmitted immediately and displayed on the PC screen. The grid can be displayed in any individual size. All control parameter are PC selectable. There are many more useful functions when connected toa PC. ‘SET ALL PARAMETER TO DEFAULT. All current parameter settings a saved automatically when switched-off, to become available for the next session. These parameter may be reset to default values following this proceedure: 1). fot switched-offpress and hold the [START/STOP/SINGLE switch for at least 3sec, to switch-off Key-Scope. 2) When switched-off, press and hold the [START/STOP/SINGLE| switch until the start-up screen has been shown and the main screen is displayed. When in main screen, release the button. All parameter are reset to default, then, “4 AUXiliary Port if I or Bl) are used, the AUXiliary Port is defined as digital input port serving the external trigger function according to its settings, If none of both external triggers are defined, this port becomes a digital output port serving as a Square Wave Signal Generator. This state is indicated in the upper menu bar. The square wave frequency can be selected individually (see chapter Menu). Note: This ports digital /0 3.3V-tolerant. Do not apply any other voltage then here specified [)ZERO LINE ADJUSTMENT [Rsimi? — Press (@) (vertically) repeatedly to reach Zero Line (see selection on the left). When Zero Line is selected, use ()) +# to adjust the zero line u

You might also like