You are on page 1of 3

Inspection Report

Date : 18/04/2018

Item Description:

Vandor Name : Applicable Standard : As per Standard ASTM B-117

Manufacturer :

Starting Date of testting : 07.04.2018 Date of Testing : 10.04.2018

Condition Specified in ASTM B-117

1 Sodium Chloride (w/v %) 5 Saturation Air Temp. ( °C )

2 Ph Value 6 Temp. of Chamber ( °C )

3 Compressed Air (KG/CM²) 7 Spray QTY. (ML/80CM²/HR)

ACCEPTANCE CRITERIA

TEST
METH
OD

Inspected By: Signature HOD (QA) :


QAF:QC:10
REV:01
Specified in ASTM B-117

Signature HOD (QA) :


SALT SPRAY TEST REPORT

Item Description : Report No. :CSBD/HWR/SST/18/001


Vandor/Manufacturer: Date :
Applicable Standard : ASTM B-117 Plating : Zinc plated
Item P.O No. : Item Receive Date :
Start date of testing : End date of testing :
Test Parameter Specified Observed Remark
1. Sodium Chloride (w/v %) 4 – 6 5
2. Ph Value 6.5-7.2 7.1
1. Sodium Chloride (w/v %) 1.5 – 2.5 (±0.1) 2.5
4. Saturation Air Temp. ( °C ) 45 (±0.1) 45
5. Temp. of Chamber ( °C ) 35 (±0.1) 35
6. Spray Qty. (ML/80CM²/HR) 1.0 – 2.0 1.5
TEST METHOD
Corrosion Resistance testing Criteria of acceptable
White Rust White Zinc corrosion covering area of 5cm² within 100cm

Red Rust Red Rust covering area of 5cm² within 100cm²


Result Interpretation
Before Testing After 72 hours

Time Corrosion Status Result


UPTO 48 Hrs. WHITE RUST REJECTED
UPTO 72 HOURS WHITE RUST & RED RUST REJECTED

Inspected By: Signature HOD (QA) :