You are on page 1of 1

TEST CERTIFICATE

Report no : SB/20/21/93 T.c no : Ref no B/00093


Week no :
Batch no : 93 PARTY NAME : RAJ ASSOCIATES
Date of Dispatch : 16/05/2021
Test Results of Autoclaved Aerated Concrete Block
Sr no. Testing Criteria IS 2185 PART 3 Specification as as per Is 2185
Grade: II ( part-3) -1984 Grade-1

Length (600mm) 598.8 to 600.4 Max +/- 5

1 Width (200mm) 199.4 to 200.4 Max +/- 3

Height (75mm) 74.2 to 75.3


y
(100mm) √ 99.2 to 100.3

√ 149.5 to 150.5 Max +/- 3
(150mm) ✓
y
y 198.1 to 200.3
(200mm)
224.1 to 225.3
(225mm)

2 Avg. Compressive Strength 4.05 Min 4


(N/mm2 or mpa )
3 Drying Content (%) 0.02 Max 0.05

4 Thermal Conductivity w/m.k 0.24 Max 0.24

5 Block Density (dry kg/m3) 612 551 to 650

6 Moisture content (%) 10.7 8 to 12

Remarks

1. This report refers Only to the specimen ( s ) Submitted for the test at Laboratory . . .
2. The random sample were collected and tested in to the laboratory at Factory Lab in charge