NIHON SPINDLE COOLING TOWERS
JS Series
Nihon Spindle JS Series
Super Low Noise
Our cooling towers are designed in accordance to Japan Cooling
Tower Institute (JCI) standard which has very stringent noise level
criterias. Our continous development on super low noise fan further
reiterated our commitment towards reducing noise level.
Energy Saving
Our power consumption for the fan meets.
‘and guideline, Our built-in drift eliminator
=
thus Conserving precious water resource
savings in terms of operation costs to the building owner.
back to
Space Saving
ur new cooling tower footprint is further reduced from previous
generations.
Our cooling towers are designed for multi-cell construction, thus
offering better flexibility in tower selection and operation.Our Successful History Our Japanese team
Quality Material
With over 50 years of experience in Manufacturing Control, Engineering
the development of cooling towers, Design, Quality Control and R&D led
Nihon Spindle continues to lead the by qualified Japanese team from
Asian market today through R&D and Nihon Spindle Manufacturing Co.,
innovation. it is an ingrained part Ltd., Osaka Japan
of Nihon Spindle's culture to seek
continuous improvement in order to
supersede existing performances and
quantity standards.
CTI Standard Test Facility
Diesel boilers to simulate heat load. ‘OOTR cooling tower CT testing
In order to maintain the highest standards of quality, our products undergo strict
annual testing according to world-renowned CTI standards. A test facility was
designed and built at our manufacturing plantin Penang, Malaysian accordance
to the specifications by a qualified and certified CT! tester. This unique CTI test
facility has a combined floor space of 15,000 sq ft and is capable of up to 1,000
tonnes heat rejection testing. Testing is accomplished to great accuracy by 4
massive diesel-boilers and numerous sensors embedded around the vicinity of
the test platform. In addition, our plant also includes a Static Fan Balancing and
Dynamic Fan Testing facility. Witnessed performance test can be arranged with
additional cost.
04
Nihon Spindle cooling towers are
produced using only the highest
‘quality components and materials, We
use hot-dipped galvanised steel
for the structure and steel parts. These
will ensure longer-lasting product life
tunder exposure to water and heat.
‘Our FRP fan blade is lighter and more
durable, and consumes less power to
run and start up.
Dynamic & Static
Fan Balancing
‘Our cooling towers are manufactured
to JIS 88609 standards. This is a
renowned high performance standard
for cooling towers that is certified by
the Japan Cooling Tower Institute. Our
performance standard incorporates
features such as minimised footprint
for the corresponding capacity
required, super low noise performance
‘and uncompromised energy effienci
Every fan set is subjected to regular
static & dynamic balancing tests
before delivery.NIHON SPINOLE COOLING TOWERS
JS Series
Hot Water Distribution System
ur crossfiow design uses hot water basin as the distribution system which
eliminate the use of nozzle spray heads. This will lower the first cost in the
pumping system and operating cost in the long run due to lower energy
consumption.
High Efficiency Infills
(ur high efficiency infils incorporate a drift eliminators which significantly
reduces drift loss to save precious water. This design is the result from years of
Research & Development, led by Japanese engineers, to continuously improve
the infil performance and efficiency.
Cost-Saving Internal Piping
This item is available as an added option to all JS models and features
an intemal piping design that help to reduce the amount of external piping
works. The unique design helps to reduce further component costs as it only
uses half the number of valves that are usually required. It also allows for a
tidier, less cluttered piping installation. Maintenance us made easier due to the
location of the values are installed on the same side.
Special Internal Walkway
The internal chambers of our Nihon Spindle cooling towers can be easily accessed
through a special internal walkway that runs along the centre of the tower.
This special feature provides better access to internal components and helps to
simplify the maintenance process, thus reducing maintenance cost. It also allows
internal inspections to be done easily and safely.
05JSHN High Performance Design
cu | ompr [OVERALL TOWER DNENSION| Fava MOTOR
oor. | EY | ERLE [wan | cengm | Heat [Diameter] motor ia
‘om | mm | mm |mxay| WW cay se ay
“EAN S067 sso 3570 a7s0[s00x 1] 22x1 | 600 | 1900 Toons?
see SOC iaso_[ ss0| 270 istonip sre] 7 oon
ISHN. Sica ja50_| 3370 3260 [isnt] 37et{ 70 26Ax2|(s0ax1] SOAKt | GOAx1 | —26hx2
eH =Stbet tos0_ | ss70 | 3250" rs0oxt| S51 | 0 aga [150K] BOAT] BORE | SA
sHN-oeT] 2050_| 3470 | 3360 [iss0x1] 8501 | 060 26Ax2|1s0he1] SOAKt | S0Axt | —26he?
SERN LISS 3os0_| S170] S280 [ax] Sse | OO TSAK2| SORT] BOAT | BOAR | PSR?
“HN LieBt 2o50_| 3170 | 3250 [2000x1] 7541 | 060 {2hx2| eta t] Soaxt | s0axt | —25A22
SsHN EBT [lessor [see 200m 751 om, 26a | 200K] ooaKT | eOaR | aA
IGHN- LIEB 8 [asso syr0_| sate | 2000x4] rot | 1.0 {2sax2| at] Boat | BOAT | —AOAE2
TEA LAEBE [Cesso [arm sate 200s tio | 200 26ax2] 200axA| BoA] Goat] AOA?
ISHN: sce & [amo_[ssro_[ 320 [renoea] 3707 | ias0 {26Ax4| 20041] BOA? | OOAxt| —40Ax2
“ean S182 8 [Caro [save [sz [eon] sez Diao “apacd|aooat| Baca e0RKT]ADAK?
ISHN Wg2 [aco [sao [ s3e0_[resoxz] 6502 | 500 26Ax4| 200A 1] BOA? | OOAx1 | —40Ax?
ssuue] , | Tayoo sm sz teoonz| sae 10 iaekut| zeta i[ cone | eoaxt | —aoaaz
GHW Lies? 3 [care0_[ a0 s2s0 [2000x2] 7542 | ‘990 {asaxa[2s0axt] aoa? | B0axt| —d0ax2
HN ZEB § [areca sass | zc0onz| 7522 | tae asad] zeta i[ coax | Boxxt | —aoAaz
ISHN Lies? E [hroo_[orm [sats [20002] 7522 | 2200 {asaxd| asta] conc | ooaxt | —d0ase
[HN LAFBe = [Cameo [aro sate [200x2] 110s | 2500 “2phad | asoAct | Axe | 60a] AOA?
ISHN: Wibas § [etso_ [sero s3s0_[es0x3] 5523 | 2400 {25Ax8| 2004.2] BOAx3 | OAx2| Oana
ISH Lo 3 [prasor [razon [s2s0 | 2o00xs) s523"| 2880 26a] 200nx2] ooAxs [coma] AOA
“SH: Liess_] Toso_[ so 3220 [2000x3| 7543 | 2700 125A | 2008 2 EES
SH LBS oso -srro_| 38 eons] 75x3 | 2600 “asa 20a aa
SHA L983 [ros [a7 [405 [2oms] 1523 | soto 125Ax6] 2A? Woks
HN LaF Toso_[ sro Sis aavoxs| tioas| saa0 saxo] ama aa
TSH Hige 700} sa70| 3380 [18804] sxe | 3250 258] 2008 «7 aOas
SHA Lt Sao | 3170| 3280 |2000xa| S520 | 3800 sax] sta 2] aoaza
SHN- Less] soo 3170 3250 [2000x4] r5xs | 3320 25ax8| 2504 2 aoa
ISH Lest Soo [S170 | S888 2000x4758 | 00 Tsai aA stare
TSH Lest 3400_[ 3170 _| sms [2000%4| 7524 | 4900 T25Ax6] 2022 aoas
SSH Lat saoo[ sro sis Teaooad| tioea| 4600 asa | 25k EITES
* AB Meteo Automate and Manus)
s stauatedn degn cartons curing product eaecton
06
‘Axial ow type fan For JSHN Models
Distribution bax for external piping connection
tohot water basinNIHON SPINDLE COOLING TOWERS
JS Series
JSHL High Performance Design & Low Noise Design
[a ar [ERLE EN FREROTOR [TONER ST | rRNA ir RESTRERENT
wooer | A | O86 [ram] teh | Hon [oiner] nai [oy Topesnl at] Out] Bein] san
es ed eee te ON Uitte ere ree cee
=i se aos ore [sed oar] ra con [oem ome ake sort] — sia
Seat ear_[-oam_[ prefer arate Fama anf a} a
ee mE a
Stat Hier San [-Sea[eaner[-sar [ans aes rtf ans ener f aa
“ISHL = LION - 2980 | 3.770 [3280 [2000x1] 55x10 [900 [2,720 [125Ax2| 150Ax1| SOAxt | SOAx1 | 25Ax2
SSS [beri Ssee [deer scr | roof go faecatmcit ance ance — ans
Sue 3 (Ceca ef eSeees eects gaat some open as
Sr sar germ ae meat aes [tee tee oats afer a
Seite], | Ferment feumest asco um [ee tees [aera a peor ame
ee fem eons ie [aoe [see Tramee| net er weet aes
Sesser 4 [amma [same [2smcat ona | sem [-asa-Tiameel smart oan mexr[ ams
Tete 3 Pb Dee ssa [asoasl soee | eae | com [eeestsomaal ass cones | ame
Sei =tione Pies [ atte p sae [eomiap este amn-[ ta brnt masa sontr/emcz| are
ecu | Het pure oe [ees ese eee | tam [ees aos] ome oes] at
Sete taar—[-3tme—[-tase—|amneal-rase[-aam[-aseo[asnre[ smna[ ware mse} — amt
SS aar—[-atm_[-tane—[asmneal oss | tam[ asm ire[ smara[ war mo| —ae
Stone saat [-s7m_[ waa [auineal sar ‘han iara[ omar o[ ore emt ame
Seo] tear [-t7m_[ sea _(aenee| Past bao _[anre/omaral anse[ eos | amet
Sturn saar_[-s7m_[-Saee[auneal ras ‘baste oaataf ose eo} ame
Stat r_{-s7n—[-tets—fenneal tase{ sae tat aekesf aac ab omer ease {ames
[A seals rate ontop on iil io reovee wer enyover. Ail fow type FPR fan for JSHL Modes
o7JSHS High Performance & Super Low Noise Design
carr [ORAL TONER OMENGION] FANEWOTOR | TONER WEOHT STAARD PP REOURENENT
moon | SRL | OMT Tam] Lena | Height [Siete] wotr | ory onering] et outa | Drain overow [WakoUn AW
imr_| vem” _| ‘mm |mmzay| sweay| ng | ag. lozengy|szexay|su0xay|azesqy| azo say
ISHS 681 “as0_[-saro—[-areo[rswoxt|-aret [rao [ taco ropes [tax | sane [sonst | pean
Seesssios] |, |g [Casto sare [sas0~Prasoxr | ener [ew [a wo anes [eons aon [smc [ee
ISHS. MIDST g 2050 | 3470 | 3480 [rasoxi| ssx1 | sio | 2sro | r2sax2| isoaxt| S0axt | S0Ax1 2OAx2
ISHS Libs! [seo [ armas amar} eset [em are [remacs| reouct | sme [eoar | pean
SHS GEST eT
gH aS 8 [aro [-aam—[ sao [rora| sare | tm fasta [eer apts [ect aos
“es-wosz—] | § [awe [-saro[ sae [iatoxz| so12 | 1700 Taskce [some [sons | ook | — ata
eis ibe § [anec} mee aemsa toes Cis Tasnea | wont | aoncg [eae [aura
ene EEE 4 [lemoc[-ar [ass famons] tere | zon faztta feencrt Leotes emwct [aos
sie woes § [ete [sam | 300 fistoxa] e519 | 200 fasaxe| somr2 | conn | eokxz | —atax
SeascebeeS] |p [aac acca amos [on [oaae Taste [soma aot | emus [aout
ISHS GEE 3 [row [-am—[ seco eorex | 7543 goon Taste [soma [eons | eouxe [aon
SHE Wiost * [gme-[-saro—[ seo [atone] eoee | ao Tesuce|-somra|-eoure | epuxz | aout
SeMESLDEET] saa0[ arm [- arm [ave] eset [a fasts [aera eoue | eons [amu
ISHS ESE San—[ 3770 [ 3800 [awe] 7848 | gore [ 1319 [wae] sens Pemee [eons | aot
“As sipunee deg condos surg pret acta
‘Axial Flow Type FRP Fan for JSHS Models A layer of PVC wire mesh to support the upper layer infil and
to separate it from the bottom ayer.
08NIHON SPINDLE COOLING TOWERS
: : JS Series
JSEN = Energy Saving Design
a |? 2 SSS Se 2 oe
os ee oot
oy sect aeeaeeetee Beare
aeons ick antes aa soceluncolatiael mis
ae Schaal at Ses bees
ENOL 1 [3703 Bae oar Tae ae | Ba | Bea
eee eect rear eearhemaae
oo aise Saal eearlrmaa
aa a Sara
aaa s ae ee
— i — ee
ae ; aa casi eeohee
=a 5 pois ee ae
ae i ae ae
ia : ate cease cole
sa i ahaa aoa
SEN ELS 37 [ 3B ‘boa S | ooAnz | AOA
soa ae sacar
age ject eeer ine ae
soa ich cece
aie vera Sache
aes oa Sacer
SEN “sro as Teoaxe | woe | aaa
ae iaiahe sisi
ETT nate 09JSEL Energy Saving And Low Noise Design
moon, | SS | ORT [am sem] Ro [ Samoa] Heer | [Oswatt Tia] Oot] Ora [ovrtw] io AE
a0 [a0 Maver [test 7e—[ avm[ aes] cant | soko Se
oan monet gist {an —[ 250 [tasnee onc [ sot gue
a [are Somer} s32t [eof sew frates front [eon Sd
foe feanet| tet ane] sau [ran sao at Sa
sa [are Saoerp seer taf aie franes sane aoe “aie
som Sot rest too [soso ame ss Sat
sa [are Sas iost{ tan aan francs ase [aon eas
“a_i fem Test vanaf fae a “ais
“anna ‘pest sree [in-use freer fame Pao a
saa Benes] sree | to [ essence] set toe sa
atop Hanes; arse imo” ean faaer ane Panna “ais
i Gepeat tt tan eae gf er ca
Feta Teste | “ass
} Gewctom acer omnrr aoe ar
3 [ach Tasha fason | won atts
2 Peecpee aise foes aut
; Gees ace omars[ sa ai
eta ante amez Lao ai
eta axe ames Lao a
a_i Tease pours pas ai
“focpuned op coon gp ton
010NIHON SPINDLE COOLING TOWERS
JS Series
JSES Energy Saving Design
vem Towa “SARE ORE REGRET
cou | oner ae B
woo, | EE | ters [lay cage] aoe eer ne
Seer Sree seer st
esc aro ae seart [aa
Sat i sear —aner
east sro sear] anti
Sess aero aste sear] amar
ess sat aoa ear] —eoare
amps sear] —anar
i ‘3ar0_|- 3350 Oar | —atax2
c i are ase seat] ae
Sees 2 | as feast | amas
sua], | § aim [ae sear] ante
aaa 2 mapas sent ama
Seas t oes Buh ee
ses uas i a7 ame soar | ates
Sess aot ; am ast soar | amar
sea ‘ om soar | ana
Sees a : arma our | —atare
essa i maa sone | ama
ese areas wears [nar
ies armas nour | —atare
asc areas wae are
esc Sree Pare [ ae
“oes ae a7 uae sou | ene
acca ae seats] —aatre
Sea] re ase aa
ses cae Srp ase seas ante
esr aoe Das wearer
states design casos ag ede seteton
Tower structures in HDG on Al standoré ‘The motor unit for every models strategically placed away from
JS Sones the discharge air stream. The wedge belts diving the fan units
‘are enclosed inside the FRP belt covers for added protection and
longer service ie
O11Cooling Tower Location
During the selection for the location of Cooling Tower, considerations should be given tothe folowing:
1. The area should provide grounded power supply forthe cooling tower. Wiring should only be installed by qualified personsl
Al elecrical wiring should comply with your regions electrical codes,
2. Cooling Towers are industrial equipments with rotating parts Place them ina secured area where unauthorized access is minimzed
3._ Place the tower ona level surface. Fllure todo so wil esultin tower and fan damage.
‘4. Donot place Cooling Tower near exhaust fans. Tis isto prevent exhaust ai from recirculated into the cooling town therefore
5. Dont place the Cooling Tower near air makeup (ventilation) unit where there is a possibility of the moist Cooling Tower discharge
air mixing withthe ar being drawn into the ar makeup (ventilation) unit,
6. Locate the tower where there is safe access for service.
7. Itis advisable and preferred to have the top of the Cooling Tower above the roofline of any adjacent building. This will limit the
possiblity of the moist discharge air rectulation back to Cooling Tower air intake
8. The height of Cooling Tower must be the same level or higher than perimeter wall to prevent recirculation of discharge hot ait
Figures)
in
Ait To Seoing
overt
osure
(Sona Wt)
_[ITE,)
{
Figure
012Engineering Specification
Cooling Tower
Each cooling tower manufactured to cool
lites per second of water from __*C
(HW) entering water temperature to
——*C (GW) leaving water temperature
at °C (WB) entering wet bulb
temperature.
The cooling towers are guaranteed to
perform in accordance with the conditions
specified without any modifications.
Structure
The cooling tower structure shall be
constructed from HDG Stee. All HDG (Hot
Dipped Galvanized) are carried out in
accordance to ISO 1461:1999, The cooling
‘tower casing shall be constructed from FRP
(Fibreglass Reinforced Polyester)
Cold Water Basin With
Integrated Sump,
‘The basin sump shall be constructed from
FFRP. The basin shall be made of FRP and
equipped with drain outlet for ease of
cleaning
Bolts & Nuts
HDG (Hot Dipped Galvanized)
Boks & Nuts shall be provided. Stainless
Stee! Bolts & Nuts avalable at addtional cost
‘upon request
Infill
Infill shall be of UV ray treated PVC
(Polyvinyl Chloride), The PVC infil shall be
vacuumformed with patented intricate
design to facilitate a good spread of water
lover the surface area of cossfiow induced
draft of air Italso incorporatea bitin drift
eliminator.
Water Distribution
System
‘The hot water distribution shallbe of open
gravity type basin. It shall be constructed
Of HOG Steet designed with multiple array
of turet-punched holes to faciltate even
distribution of stable water sprinkling
fet.
Mechanical Equipment
(Fan Section)
Fansshallbeaxialfow typewithFRP blades.
‘The fans shall be designed to provide
necessary air flow for heat transfer, Fan
blades shall be assembled, balanced and
pitched, The fan shall operate within a FRP
fan cylinder, which provides a streamlined
air entry and minimum tip clearance for
‘maximum fan efficiency
Access
[A FRP inspection door shall be provided
to facilitate entry into the cooling tower
for inspection and maintenance. A HOG
Steel access ladder shal be installed on the
cooling tower,
NIHON SPINDLE COOLING TOWERS
JS Series
Motor
‘The fan motor() shall be to IPSS standard
‘with ClassF insulation, specifically designed
{or cooling tower service, The motor shall
bbe located adjacent tothe fan cylinder for
‘ease of maintenance and increased motor
life expectancy. The motor shall be fully
‘outside of the moist discharge airstream.
Mechanical Support
‘The mechanical support shall be of HOG
‘Steel and bolted to the top of fan cylinder.
HDG Steel fan guard shall be bolted to
‘the top of mechanical support for safety
measure. Extended lubrication lines shall
be provided to the bearings with grease
nippleslocated outside foreaseofschedule
maintenance.
Wedge-Belt Drive
System
‘The wedge-beltshallbefabricimpregnated
type. Belt tensioning adjustment shall be
provided. Entire drive arrangement shall be
protected by a FRP cover,
013Optional Accessories
Vibration Isolators
Pa
—"
Mounted at the feet ofthe cooling tower,
vibration isolators provide an effective way
of isolating ary vibsation from the tower to
the concrete floors
Single-spring and double-spring design
are generally sufficient to meet the
requirements of the range of Nihon
Spindle cooling towers. Selection of the
right sizes depending on rated load and
rated deflection
Vibration Switch
Vibration switch is mounted on the cooling
tower fan deck where f there is any
excessive vibration, it will cut off power
supply to fan motor.
Extended Discharge
Hood (Angle/ Straight)
Wherever the discharge of airis necessary
to be diverted towards a certain direction,
RP extended discharge hood can beeaslly
Installed onto the standard fan cylinder.
014
Aluminium Alloy Blade
‘Aluminium alloy blades are available as an
‘optional tem to our standard FRP blades.
“These blades are recommended for use in
highly corosive enviroments
Handrail & Caged Ladder
Handtall and caged ladder can be supplied
san optional item for added safety when
the fan deck is relatively high above
‘round.
Additional Drift
Eliminators
SS
»
‘Additional deft eliminators can be supplied
‘when very low drift losis to be achieved.
Additional drift eliminators can further
reduce dif loss to as low a5 0.001% of the
circulating water flowrate.
Gear Reducer
As an alternative to wedge belt drive
system, gear reducer option Is avallabl.
The motors located outside the ar steam.
Epoxy Fusion Coating
Wherever extra corrosion protection Is
needed over the standard hot dipped
galvanized stel parts epoxy fusion coating
is available as option,
Hot Water Basin Cover
The hot water basin coverisavalable as an
added protection to the hot water basin
fom gathering dit, foreign particles and
‘objects that can clog the basinNIHON SPINDLE COOLING TOWERS
JS Series
Cooling Tower Water Treatment
Water Quality
The open tecirculating cooling tower concentration which isthe ratio of dissolved solids Inthe circulating water to dissolved
system has the greatest potential for solidsin themake-up water This should be determined and monitored frequently through
problems associated with fouling, water reatment.
Corrosion and microbiological organisms.
Even the highest quality water contains The annexed table Ists the water quality standards for use with refigeration and alt-
some amount of dissolved sols that conditioning equipment. For maximum heat transfer efficiency and maximum equipment
become concentrated over time, posing life these guidelines should be followed,
potential threat to corrosion and fouling,
This is further enhanced by the effects
of air pollution and make-up water
it t wt 68-90
contamination cE ee
‘The degree to which dissolved solids and Retteriens < 250 ppm
ther Impurties bull up in recculaing | oAKA <200 6m
here <120 59m
water may be defined as the cycles of
Water Treatment
‘As a cooling tower manufacturer, we strive to offer a complete solution to condenser
water issues with water treatment program,
‘The water treatment system should minimally consist of chemicalsand dosing equipments.
Chemicals can be dosed in automatically at a predetermined amount and duration Wenow offer
Alternatively, we can offer conductivity control system that has a pre-set range, whereby water treatment
"upon reaching is limit, blowdown will automaticaly take place and stop when its lower solution within
limits reached. Klang Valley area
‘The blowdown conducted isto contol scale build-up and corrosion Alin all, the water
‘treatment program should be able to control or minimise scale, corrosion, algae and
microorganisms including the possible outbreak of Legionnaire Disease.
Last but not least the chemicals must be compatible with the materials of construction of.
all cooling tower parts in contact with the recirculating water.
Fally automatic chemical dosing system with conductivity Overview of the installation at site,
controller and pumps.
O15Giant Hypermarkets in Malaysia 4Jusco Shopping Malls in Malaysia Econsave Hypermarkets in Malaysia
Carrefour Hypermarkets in Malaysia Westin Langkawi, Malaysia Damai Beach Resort, Kuching,
Malaysia
Capital Square Phase 2, Kuala Lumpur, Sunway Giza, Kota Damansara,
Malaysia Malaysia
Surian Tower, Mutiara Damansara Menara UOA Bangsar, Malaysia Yayasan Selangor, Kuala Lumpur,
Malaysia Malaysia|| Unive Teexoeogr Mara
New National Palace, Malaysia Rapid KL LRT Station - Masjid Jamek, _UITM Puncak Alam Campus, Malaysia
Dang Wangi, KLCC, Kampung Baru &
‘Ampang Park, Malaysia
Sony Bangi Factory, Malaysia ASE Electronics, Penang Malaysia
Borneo Convention Centre, Kuching, _Meritus Mandarin Hotel, Singapore Hotel Grand Central, Singapore
Malaysia
Emirate Glass Factory, Oubai
NUS Business School, Singapore ‘National Parks Board Headquarters,
Singaporewww.spindle.com.my
NIHON SPINDLE COOLING TOWERS SDN BHD (782210-p)
Cr aM eee Ren oe SUE)
Head Office: Peed ied
PO ue CUCM ou cea Ee a Ke Une ecu
Peco mcae Ee PIU 3, 47410 Selangor, Malaysia.
DEE Se OEE Ley SEE On Ci Seek eC E erg
ome
=o peeaee eet