You are on page 1of 178

FibeAir® 1500HP/RFU-HP

Installation Guide

Part ID: BM-0111-0


Doc ID: DOC-00015514 Rev D
August 2015

Copyright © 2015 by Ceragon Networks Ltd. All rights reserved.


FibeAir® 1500HP/RFU-HP Installation Guide

Notice
This document contains information that is proprietary to Ceragon Networks Ltd. No part of this
publication may be reproduced, modified, or distributed without prior written authorization of
Ceragon Networks Ltd. This document is provided as is, without warranty of any kind.

Trademarks
Ceragon Networks®, FibeAir® and CeraView® are trademarks of Ceragon Networks Ltd.,
registered in the United States and other countries.
Ceragon® is a trademark of Ceragon Networks Ltd., registered in various countries.
CeraMap™, PolyView™, EncryptAir™, ConfigAir™, CeraMon™, EtherAir™, CeraBuild™, CeraWeb™,
and QuickAir™, are trademarks of Ceragon Networks Ltd.
Other names mentioned in this publication are owned by their respective holders.

Statement of Conditions
The information contained in this document is subject to change without notice. Ceragon
Networks Ltd. shall not be liable for errors contained herein or for incidental or consequential
damage in connection with the furnishing, performance, or use of this document or equipment
supplied with it.

Open Source Statement


The Product may use open source software, among them O/S software released under the GPL or
GPL alike license ("Open Source License"). Inasmuch that such software is being used, it is
released under the Open Source License, accordingly. The complete list of the software being
used in this product including their respective license and the aforementioned public available
changes is accessible at:
Network element site:
ftp://ne-open-source.license-system.com
NMS site:
ftp://nms-open-source.license-system.com/

Information to User
Any changes or modifications of equipment not expressly approved by the manufacturer could
void the user’s authority to operate the equipment and the warranty for such equipment.

Ceragon Proprietary and Confidential Page 2 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

Table of Contents
1. About This Guide.............................................................................................. 7

2. What You Should Know ................................................................................... 7


3. Target Audience ............................................................................................... 7
4. Related Documents .......................................................................................... 7

5. Important Notes ................................................................................................ 8


6. 1500HP/RFU-HP Models and Part Numbers ................................................... 9
7. FibeAir 1500HP/RFU-HP OCBs ...................................................................... 10
7.1.1 OCB Components ........................................................................................................ 11
7.1.2 OCB Part Numbers ...................................................................................................... 12
7.1.3 OCB Part Number Format............................................................................................ 12

8. Split-Mount Installation with the OCB ........................................................... 13


8.1 Required Tools for the OCB Installation ...................................................................... 13
8.2 Special Tools/Materials ................................................................................................ 13
8.3 Pole Mount Preliminary Assembly ............................................................................... 14
8.4 Installing Couplers ........................................................................................................ 15
8.5 Installing S-Bends and the DCB .................................................................................. 16
8.6 Short Installation .......................................................................................................... 17
8.7 Termination Installation ................................................................................................ 18
8.8 Short with Tapped Holes Installation ........................................................................... 19

9. Final Branching Installation ........................................................................... 20


10. Connecting the RFU to the OCB .................................................................... 21
11. Housing Assembly and Lifting Harness ....................................................... 22
12. Pole Installation .............................................................................................. 23
13. Hanging Positions .......................................................................................... 24
14. Outdoor Branching Network (OBM) Housing Hanging Procedure .............. 25
15. Connecting a Flexible Waveguide ................................................................. 26
16. RFU Cable Connections ................................................................................. 27
17. Grounding the 1500HP/RFU-HP ..................................................................... 29
18. Installation Instructions for Specific Configurations ................................... 30
18.1 1+0 ............................................................................................................................... 31
18.2 1+0 SD ......................................................................................................................... 33
18.3 1+1 SD IFC .................................................................................................................. 35

Ceragon Proprietary and Confidential Page 3 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

18.4 1+1 HSB ....................................................................................................................... 39


18.5 2+0 DP ......................................................................................................................... 42
18.6 2+0 SP ......................................................................................................................... 45
18.7 2+0 SD SP ................................................................................................................... 48
18.8 2+0 SD DP ................................................................................................................... 51
18.9 2+2 SD SP ................................................................................................................... 54
18.10 2+2 SD DP (Non-Upgradable) ..................................................................................... 65
18.11 2+2 HSB DP (Ready for Upgrade) ............................................................................... 70
18.12 2+2 HSB DP (Non-Upgradable) ................................................................................... 74
18.13 2+2 HSB SP ................................................................................................................. 78

19. Upgrade Instructions...................................................................................... 84


19.1 Upgrading from 1+1 SD to 2+2 SD SP ........................................................................ 84
19.2 Upgrading from 1+1 HSB SP to 2+2 HSB SP ............................................................. 96
19.3 Upgrading from 2+2 DP to 3+3 DP ............................................................................ 103
19.4 Upgrading from 2+2 SD SP to 3+3 SD SP ................................................................ 107
19.5 Upgrading from 2+2 SD DP to 3+3 SD DP ................................................................ 119
19.6 Upgrading from 2+2 HSB SP to 3+3 HSB SP ........................................................... 123
19.7 Upgrading from 3+3 DP to 4+4 DP ............................................................................ 130
19.8 Upgrading from 3+3 SD DP to 4+4 SD DP ................................................................ 135
19.9 Upgrading from 3+3 SD SP to 4+4 SD SP ................................................................ 140
19.10 Upgrading from 3+3 HSB SP to 4+4 HSB SP ........................................................... 144

20. Split Trunk Configurations........................................................................... 149


20.1 1+1/2+2 HSB Configurations ..................................................................................... 149
20.2 N+0/N+1 Single Pole Configurations (N = 1 to 5) ...................................................... 150
20.3 N+0/N+1 CCDP Configurations (N = 1 to 5) .............................................................. 152
20.4 N+0/N+1 CCDP Configurations (N = 5 to 10) ............................................................ 154

21. All Indoor Horizontal Installation ................................................................. 157


21.1 1+0 Installation ........................................................................................................... 158
21.1.1 Parts Used ................................................................................................................. 158
21.1.2 Assembly .................................................................................................................... 158
21.2 1+0 East-West Installation ......................................................................................... 161
21.2.1 Parts Used ................................................................................................................. 161
21.2.2 Assembly .................................................................................................................... 161
21.3 1+1 HSB (Hot Standby) Installation ........................................................................... 164
21.3.1 Parts Used ................................................................................................................. 164
21.3.2 Assembly .................................................................................................................... 164

Ceragon Proprietary and Confidential Page 4 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

22. Appendix A: Electrical Diagrams................................................................. 167

Safety Precautions & Declared Material


General Equipment Precautions

Use of controls, adjustments, or performing procedures other than those


! specified herein, may result in hazardous radiation exposure.

When working with a FibeAir IDU, note the following risk of electric
shock and energy hazard: Disconnecting one power supply disconnects
! only one power supply module. To isolate the unit completely,
disconnect all power supplies.

Machine noise information order - 3. GPSGV, the highest sound pressure


! level amounts to 70 dB (A) or less, in accordance with ISO EN 7779.
Static electricity may cause body harm, as well as harm to electronic
components inside the device.
Anyone responsible for the installation or maintenance of the FibeAir RFU-C
must use an ESD Wrist Strap.
ESD protection measures must be observed when touching the RFU.
To prevent damage, before touching components inside the device, all
electrostatic must be discharged from both personnel and tools.

! In Norway and Sweden:


Equipment connected to the protective earthing of the building installation
through the mains connection or through other equipment with a connection
to protective earthing – and to a cable distribution system using coaxial cable,
may in some circumstances create a fire hazard. Connection to a cable
distribution system has therefore to be provided through a device providing
electrical isolation below a certain frequency range (galvanic isolator, see EN
60728-11).
Utstyr som er koplet til beskyttelsesjord via nettplugg og/eller via annet
jordtilkoplet utstyr – og er tilkoplet et kabel-TV nett, kan forårsake brannfare.
For å unngå dette skal det ved tilkopling av utstyret til kabel-TV nettet
installeres en galvanisk isolator mellom utstyret og kabel- TV nettet.
Utrustning som är kopplad till skyddsjord via jordat vägguttag och/eller via
annan utrustning och samtidigt är kopplad till kabel-TV nät kan i vissa fall
medfőra risk főr brand. Főr att undvika detta skall vid anslutning av
utrustningen till kabel-TV nät galvanisk isolator finnas mellan utrustningen
och kabel-TV nätet.

Ceragon Proprietary and Confidential Page 5 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

Précautions générales relatives à l'équipement

L’utilisation de commandes ou de réglages ou l'exécution de procédures


! autres que celles spécifiées dans les présentes peut engendrer une
exposition dangereuse aux rayonnements.

L’usage de FibeAir IDU s’accompagne du risque suivant d'électrocution


et de danger électrique : le débranchement d'une alimentation
! électrique ne déconnecte qu'un module d'alimentation électrique. Pour
isoler complètement l'unité, il faut débrancher toutes les alimentations
électriques.

Bruit de machine d’ordre - 3. GPSGV, le plus haut niveau de pression


! sonore s'élève à 70 dB (A) au maximum, dans le respect de la norme ISO
EN 7779.

Allgemeine Vorsichtsmaßnahmen für die Anlage

Wenn andere Steuerelemente verwendet, Einstellungen vorgenommen


! oder Verfahren durchgeführt werden als die hier angegebenen, kann
dies gefährliche Strahlung verursachen.

Beachten Sie beim Arbeiten mit FibeAir IDU das folgende Stromschlag-
und Gefahrenrisiko: Durch Abtrennen einer Stromquelle wird nur ein
! Stromversorgungsmodul abgetrennt. Um die Einheit vollständig zu
isolieren, trennen Sie alle Stromversorgungen ab.

Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste


! Schalldruckpegel beträgt 70 dB(A) oder weniger gemäß EN ISO 7779.

Ceragon Proprietary and Confidential Page 6 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

1. About This Guide


This guide describes the FibeAir 1500HP/RFU-HP installation procedures and
provides additional information concerning system parts and frequency bands.

2. What You Should Know


This guide provides general instructions for assembling the 1500HP/RFU-HP
components, as well as instructions for assembling specific split-mount and
all-indoor configurations.
Important! For the warranty to be honored, install the unit in accordance
with the instructions in this manual.

3. Target Audience
This guide contains technical information about 1500HP/RFU-HP installation, and
is intended for use by qualified Ceragon technical personnel at all levels.

4. Related Documents
 FibeAir IP-20N Installation Guide – DOC-00040492
 FibeAir IP-20A Installation Guide – DOC-00040961
 FibeAir IP-20G Installation Guide – DOC-00041192
 FibeAirIP-10G Installation Guide –DOC-00023199
 FibeAir IP-10E Installation Guide –DOC-00029444
 FibeAir IP-10Q Installation Guide, DOC-00029546

Ceragon Proprietary and Confidential Page 7 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

5. Important Notes
 1500HP/RFU-HP is intended for installation in a Restricted Access
Location.
 1500HP/RFU-HP must be installed and permanently connected to
protective earth by qualified service personnel in accordance with
applicable national electrical codes.
 The FibeAir system is to be installed in Network Telecommunication
Facilities.

The intra-building port(s) of the equipment or subassembly is suitable


for connection to intra-building or exposed wiring or cabling only. The
intra-building port(s) of the equipment or subassembly MUST NOT be
WARNING! metallically connected to interfaces that connect to the OSP or its
wiring. These interfaces are designed for use as intra-building interfaces
only (Type 2 or Type 4 port as described in GR-1089-CORE, Issue 4) and
require isolation from the exposed OSP cabling. The addition of Primary
Protectors is not sufficient protection in order to connect these
interfaces metallically to OSP wiring.

Ceragon Proprietary and Confidential Page 8 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

6. 1500HP/RFU-HP Models and Part Numbers


The RFU-HP can be installed in split-mount and all-indoor configurations.
The 1500HP has a 1 receiver (1RX) and 2 receiver (2RX) options. The 1500HP
2RX can be used for IF Combining (IFC) Space Diversity. However, 1500 HP 56
MHz bandwidth does not support IFC Space Diversity.
The following table lists and describes the available 1500HP/RFU-HP models.
All RFU models are suited to operate in indoor and outdoor environments.

RFU Models – 1RX Units

Marketing Model Description


RFU-HP-1R-6L RFU-HP 6LG 1Rx up to 56M SM / All Indoor
RFU-HP-1R-6H RFU-HP 6HG 1Rx up to 56M SM / All Indoor
RFU-HP-1R-7 RFU-HP 7G 1Rx up to 56M SM / All Indoor
RFU-HP-1R-8 RFU-HP 8G 1Rx up to 56M SM / All Indoor
15HPA-1R-RFU-11 1500HP 11G 1RX SM / All Indoor Up to 30 MHz
15HPA-1R-RFU-11w 1500HP 11G 1RX SM / All Indoor 40 MHz

RFU Models – 2RX Units

Marketing Model Description


15HPA-2R-RFU-6L 1500HP 6LG 2RX SM / All Indoor Up to 30 MHz
15HPA-2R-RFU-6Lw 1500HP 6LG 2RX SM / All Indoor 40 MHz
15HPA-2R-RFU-6H 1500HP 6HG 2RX SM / All Indoor Up to 30 MHz
15HPA-2R-RFU-6Hw 1500HP 6HG 2RX SM / All Indoor 40 MHz
15HPA-2R-RFU-7 1500HP 7G 2RX SM / All Indoor
15HPA-2R-RFU-8 1500HP 8G 2RX SM / All Indoor
15HPA-2R-RFU-11 1500HP 11G 2RX SM / All Indoor Up to 30 MHz
15HPA-2R-RFU-11w 1500HP 11G 2RX SM / All Indoor 40 MHz

Ceragon Proprietary and Confidential Page 9 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

7. FibeAir 1500HP/RFU-HP OCBs


FibeAir 1500HP/RFU-HP supports two types of OCBs:
 Old OCB
 OCB
Both OCBs are compatible with all RFU-HP/1500HP part numbers.
Old OCB OCB

This installation guide describes installations using the newer type OCB. For
installation procedures using the older type OCB, refer to Revision B and older
versions of this Installation Guide.
The OCB is optimized for configurations that do not use IFC Space Diversity.
To support IFC Space Diversity, a diversity block is added.
The OCB has just one type, and can be connected to an antenna via a flexible
waveguide.
The OCB connection is at the rear of the OCB. It includes proprietary
accessories (different than those used for the older OCB).
Each OCB has three waveguide access points: The In/Out port is located at the
rear of the OCB.
The OCB ports include:
 Tx port
 Rx Port
 Diversity port
If the system is not configured for diversity, all the relevant access points on
the OCB must be terminated using waveguide shorts. Unused Rx ports will be
terminated with a WG termination.

Ceragon Proprietary and Confidential Page 10 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

7.1.1 OCB Components


The OCB includes the following components:
DCB (Diversity Circulator Block) Coupler Kit

U-Bend S-Bend Pole-Mount Kit

OCB components include the following:


 RF Filters – RF Filters are used for specific frequency channels and Tx/Rx
separation. The filters are attached to the OCB, and each RFU contains one
Rx and one Tx filter. In a Space Diversity configuration, with IF combining,
each RFU contains two Rx filters (which combine the IF signals) and one
Tx filter. The filters can be replaced without removing the OCB.
 DCB (Diversity Circulator Block) – An external block which is added in
Space Diversity configurations. The DCB is connected to the diversity port
and can chain two OCBs.
 Coupler Kit – The coupler kit is used for 1+1 Hot Standby configurations.
 U Bend – The U Bend connects the chained DCB (Diversity Circulator
Block) in N+1/N+ 0 configurations.
 S Bend – The S Bend connects the chained OCB (Outdoor Circulator Block)
in N+1 /N+ 0 configurations.
 Pole Mount Kit – The Pole Mount Kit can fasten up to five OCBs and the
RFUs to the pole. The kit enables fast and easy installation.

Ceragon Proprietary and Confidential Page 11 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

7.1.2 OCB Part Numbers


The following table presents the various RFU options and the configurations
in which they are used. This table is applicable for all OCB configurations (Split
Mount and Compact All Indoor).

OCB Part Numbers

Band CHBW IFC Adjacent Marketing Model


No No 15OCBf-xxxy-nn-L/H

28/30 No Yes 15OCBf-xxxy-nnA-L/H


MHz Yes No 15OCBf-SD-xxxy-nn-L/H
Yes Yes 15OCBf-SD-xxxy-nnA-L/H
No No 15OCBf-xxxy-40N-nn-L/H
6, 7 and 8 GHz
No Yes 15OCBf-xxxy-40N-nnA-L/H
40 MHz
Yes No 15OCBf-SD-xxxy-40N-nn-L/H
Yes Yes 15OCBf-SD-xxxy-40N-nnA-L/H
No No 15OCBf-xxxy-56N-nn-L/H
56 MHz
No No 15OCBf-xxxy-56N-n-m-L/H

28/30 No No 15OCBf-xxxy-nn-L/H
MHz Yes No 15OCBf-SD-xxxy-nn-L/H
11 GHz
No No 15OCB11w-xxxy-nn-L/H
40 MHz
Yes No 15OCB11w-SD-xxxy-nn-L/H

7.1.3 OCB Part Number Format


Place Holder in Possible Values Description and Remarks
Marketing Model
f 6L,6H,7,8,11
xxx 000-999 [MHz] TRS in MHz
Y A…Z Ceragon TRS block designation
ZZZ Examples: Designation of the channels the
1W3 – “Wide” filters covering OCB is covering
channels 1-3
03 – Only channel 03, 28MHz
channel
3-5 – 56MHz “Narrow” filters
allowing concatenation using OCBs
covering channels 3 and 4.
03A – For Channel 03, 28 and 40
MHz adjacent channels
H/L H or L Designating TX High and TX low

Ceragon Proprietary and Confidential Page 12 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

8. Split-Mount Installation with the OCB


This section provides installation procedures for the OCB.
Note: For installation procedures using the older type OCB, refer
to Revision B and older versions of this Installation Guide.

8.1 Required Tools for the OCB Installation


 Screwdriver Philips/ screw head bits size 2
 Ratchet 11/16''
 Wrench 3/16"
 Hexagon Socket 5mm
 Allen wrench 2.5mm
 Allen wrench 5mm
 Allen wrench 6mm

8.2 Special Tools/Materials


None.

When assembling, make sure the waveguide connector plastic covers


remain intact. Any damage to the covers may result in improper
operation of waveguides and the RFU.
WARNING!

Note: Every screw fastening operation must comply with the


enclosed Torque Table; make sure you apply appropriate
torque every time.
Tightening Torques

Thread Size Tightening Torque (Nm)


8-32 UNC 2.0 ± 0.2
10-32 UNF 3.0 ± 0.3
M8x1.25 16 ± 1.0
M10x1.5 25 ± 1.1

Ceragon Proprietary and Confidential Page 13 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

8.3 Pole Mount Preliminary Assembly


Description Quantity
Nut, Hex, SS, DIN 934-M10-A2-70 4
Washer, Helical spring lock SS, DIN 127-
2
B10-A2-70
Screw, Hex cap, SS, DIN 933-M10x200-
2
A2-70
Hanging Profile 1

1 Insert two screws (3) into the two lower hanging profile (4) holes and
secure them with four nuts (1) and two washers (2) (do not tighten) (Step
I in illustration below).
2 Arrange the OCBs (5) in a straight line and place the hanging profile (4)
(Step II).

Ceragon Proprietary and Confidential Page 14 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

8.4 Installing Couplers


To install a coupler:
1 Place sealing gaskets (supplied in coupler kit) in the coupler flange
grooves.
2 Connect the coupler with the gaskets to the relevant ports.
3 Tighten the built-in screws to the OCB.

Ceragon Proprietary and Confidential Page 15 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

8.5 Installing S-Bends and the DCB


1 Place the sealing gaskets (supplied with the S-Bend/DCB kit) in the flange
grooves.
2 Connect the S-Bend/DCB with the gaskets to the relevant ports.
3 Tighten the built-in screws to the OCB.

Ceragon Proprietary and Confidential Page 16 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

8.6 Short Installation


1 Install the short plate using the flange gasket, screws, and washers
supplied with the short kit as shown below.

Ceragon Proprietary and Confidential Page 17 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

8.7 Termination Installation


1 Install the termination using the flange gasket, screws and washers
supplied with the termination kit as shown below

Ceragon Proprietary and Confidential Page 18 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

8.8 Short with Tapped Holes Installation


1 Install the short plate with tapped holes using the gasket supplied with the
DCB kit and DCB captive screws as shown below.

Ceragon Proprietary and Confidential Page 19 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

9. Final Branching Installation


1 Fasten two screws (1) and spring washers (2) for each installed OCB.
2 Fasten lifting eye to each OCB unit (5) (if not already installed).

Description Quantity Remarks


Screw, Socket hexagon head cap,
2
SS, DIN 912-M8x30-A2-70
The quantities are for one
Washer, Helical spring lock, SS, OCB and may change in
2
DIN 7980-8.1-A2-70 accordance with the
Couplers - installed configuration
(up to five OCBs)
Lifting Collar Eye Bolt M8-1.25
1
steel, Zink plated

Ceragon Proprietary and Confidential Page 20 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

10. Connecting the RFU to the OCB


Make sure the RFUs (2) are inserted correctly; do not force them in!

WARNING!

1 Carefully insert the RFUs (2) into the slots on the OCB units (1).
2 Fasten two screws (3) using the angled Allen wrench. The torque for the
screws should be 12Nm.

Description Quantity Remarks


OCB Assy. 1
The quantities are for one RFU and may
RFU 1 change in accordance with the installed
configuration (up to five RFUs)
Screw (part of RFU Assy) 2

Ceragon Proprietary and Confidential Page 21 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

11. Housing Assembly and Lifting Harness


1 Choose one of four (5) available positions for the pole installation. Refer to
Hanging Positions on page 24.
2 Fasten two screws (3) and spring washers (4) to attach the Pillar Housing
(1) to the Hanging Profile (2).
3 Tie the lifting harness (6) to the lifting ears (7) on all OCB units.
CAUTION!
Before lifting, make sure all OCB units are properly tied to the lifting harness.
4 Carefully lift the assembly for Pole Installation.

Description Quantity
Pillar Housing 1
Hanging Profile 1
Screw, Phillips Pan head, SS, ANSI, #8-
2
32UNCx1/2"
Washer, Helical spring lock, SS, ANSI, #8 2

Ceragon Proprietary and Confidential Page 22 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

12. Pole Installation


1 Insert two screws (in addition to the two screws already inserted (see Pole
Mount Preliminary Assembly on page 14) (4) through the holes in the
Hanging Profile (4).
2 Press the Hanging Profile (4) against the Pillar Housing, while mounting
the Pillar Clamp (3) on the screws (5).
3 Tighten the spring washer (2) and two nuts (1) on each of the four screws,
to fasten the Hanging Profile (6) to the Pole (7).

Description Quantity
Nut, Hex, SS, DIN 934-M10-A2-70 8
Washer, Helical spring lock SS, DIN 127-B10-A2-70 4
Pillar Clamp 1
Hanging Profile 1
Screw, Hex cap, SS, DIN 933-M10x200-A2-70 4

Ceragon Proprietary and Confidential Page 23 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

13. Hanging Positions


You can pole mount the Hanging Profile on any of the four available positions,
as shown in the following illustration.

Ceragon Proprietary and Confidential Page 24 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

14. Outdoor Branching Network (OBM) Housing


Hanging Procedure
Do not lift the OCB using the RFU handle; use the lifting eye only!

WARNING!

1 Lift the OBN OCB Housing (3) using the lifting eye (5).
2 Tilt the OBN OCB Housing (shown below without the RFU) (3) backwards,
and hook it to the Hanging Profile (4) so that the screw holes are aligned.
3 Fasten two screws (1) and spring washers (2).
4 Hang up to five OBN OCB Housing (3) units (in accordance with the
relevant configuration).
5 Install the RFU (6).

Description Quantity Remarks


Screw, Socket hexagon head cap,
2
SS, DIN 912-M8x30-A2-70
The quantities are for one
Washer, Helical spring lock, SS, DIN
2 RFU and may be changed in
7980-8.1-A2-70
accordance with the installed
OBN OCB Housing 1 configuration (up to five
RFUs)
Hanging Profile 4 RFU’s
RFU 1

Ceragon Proprietary and Confidential Page 25 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

15. Connecting a Flexible Waveguide


1 Connect the Flexible Waveguide using the flange gasket, screws, and
washers supplied with the Flexible Waveguide kit as shown below.

Ceragon Proprietary and Confidential Page 26 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

16. RFU Cable Connections


The RFU cable connectors are located on the bottom of the RFU, as shown in
the following photo:

IF Cable

Source
Sharing /
RSL

Ceragon Proprietary and Confidential Page 27 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

Waveguide

Waveguide

Ground

Waveguide

The connections include the following:


 XPIC/RSL – For XPIC functionality and radio signal monitoring.
 IF – Connects the RFU to the IDU.
 Ground – Used for electrical ground.
 Flexible Waveguide – Connects the RFU to the antenna.

Ceragon Proprietary and Confidential Page 28 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

17. Grounding the 1500HP/RFU-HP


 The RFU is suitable for installation in a Common Bonding Network (CBN).
 Only copper wire should be used.
 The coaxial port cables should be shielded and grounded at both ends.
 The wire must be at least 14 AWG or thicker.
 Connector and connection surfaces must be plated. Bare conductors must
be coated with antioxidant before crimp connections are made to the
screws.
 FibeAir provides a ground for each drawer, via a one-hole mounted lug
onto a single-point stud. The stud must be installed using a UL-listed ring
tongue terminal, and two star washers for anti-rotation.
 For antenna ports, lightning protection is used that does not permit
transients of a greater magnitude than the following:
 Open Circuit: 1.2-50us 600V
 Short Circuit: 8-20us 300A
 FibeAir’s battery return terminals are in the configuration of an Isolated
DC return (DC-I) and Common DC Return (DC-C).
The grounding point is assembled as shown in the following illustration.

Single point stud

Tooth Washer
Nut

Terminal

Ceragon Proprietary and Confidential Page 29 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

18. Installation Instructions for Specific


Configurations
This chapter provides detailed instructions for specific FibeAir 1500HP/RFU-
HP configurations.
Note that in this chapter, the following abbreviations are used:
 HSB - Hot Standby
 FD - Frequency Diversity
 SD - Space Diversity
 DP - Dual Pole
 MP - Main Path
 SP - Secondary Path
 MA - Main Antenna
 DA - Diversity Antenna
 N/A - Not Applicable
 WG - Waveguide
 X/Y dB: X refers to 6-8 GHz, Y refers to 11 GHz

Ceragon Proprietary and Confidential Page 30 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

18.1 1+0

List of Items per Terminal

Description Marketing Model Quantity

RFU-HP-1R-f or
RFU 1Rx 1
15HPA-1R-RFU-11
OCB with filters 15OCBfx-xxxY-aa-L/H 1

OCB Pole mount kit OCB-Pole Mount 1


15HP Short for WRccc Kit 15HP-SHORT-ccc 1
1500HP WGWG Termination, WRccc
15HP-TERM-ccc 1
Kit
Flexible WG Kit 3200T Flx WG xFT fGHz 1

Procedure

1 Mount the termination and short flange on the rear side, as described in
Short Installation on page 17 and Termination Installation on page 18.
2 Mount the OCB to the OCB pole mount, as described in Pole Mount
Preliminary Assembly on page 14.
3 Mount the radio to the OCB, as described in Outdoor Branching Network
(OBM) Housing Hanging Procedure on page 25.

Ceragon Proprietary and Confidential Page 31 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

4 Attach the pole mount bracket to the pole, as described in Pole Mount
Preliminary Assembly on page 14.

5 Mount the flexible waveguide and O-ring to the main (upper) port using
the screws and washers supplied with the Flexible Waveguide kit, as
described in Connecting a Flexible Waveguide on page 26.

Ceragon Proprietary and Confidential Page 32 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

18.2 1+0 SD

List of Items per Terminal

Description Marketing Model Quantity

RFU 2Rx 15HPA-2R-RFU-f 1


OCB 2RX with filters 15OCBfx-SD-xxxY-aa-L/H 1
OCB Pole mount kit OCB-Pole Mount 1

15HP Short for WRccc Kit 15HP-SHORT-ccc 1


1500HP WG Termination, WRccc Kit 15HP-TERM-ccc 1
Flexible WG Kit 3200T Flx WG xFT fGHz 2

Procedure

1 Mount the termination and short flange on the rear side, as described in
Short Installation on page 17 and Termination Installation on page 18.
2 Mount the OCB to the OCB pole mount, as described in as described in Pole
Mount Preliminary Assembly on page 14.
3 Mount the radio to the OCB, as described in Outdoor Branching Network
(OBM) Housing Hanging Procedure on page 25.

Ceragon Proprietary and Confidential Page 33 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

4 Attach the pole mount bracket to the pole, as described in Pole Mount
Preliminary Assembly on page 14.

5 Mount both the flexible waveguide and the O-ring to the MAIN port and
the DIV port using the screws and washers supplied in the Flexible
Waveguide kit, as described in Connecting a Flexible Waveguide on
page 26.

Ceragon Proprietary and Confidential Page 34 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

18.3 1+1 SD IFC

List of Items per Terminal

Description Marketing Model Quantity

RFU 2Rx 15HPA-2R-RFU-f 2


OCB 2Rx with filters 15OCBfx-SD-xxxY-aa-L/H 2
OCB Pole mount kit OCB-Pole Mount 1

1500HP WG Termination, WRccc Kit 15HP-TERM-ccc 2


OCB Coupler f GHz OCB-CPLR-f 2

Procedure

1 Mount the termination on the rear side, as described in Termination


Installation on page 18.

Ceragon Proprietary and Confidential Page 35 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

2 Mount the OCB to the OCB pole mount, as described in as described in Pole
Mount Preliminary Assembly on page 14.

3 Mount the radio to the OCB, as described in Outdoor Branching Network


(OBM) Housing Hanging Procedure on page 25.

Ceragon Proprietary and Confidential Page 36 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

4 Attach a coupler to the Main OCB Waveguides and secure it with screws.

5 Attach a coupler to the Div OCB Waveguides and secure it with screws.

Ceragon Proprietary and Confidential Page 37 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

6 Attach the pole mount bracket to the pole, as described in Pole Mount
Preliminary Assembly on page 14.

Ceragon Proprietary and Confidential Page 38 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

18.4 1+1 HSB

List of Items per Terminal

Description Marketing Model Quantity

RFU-HP-1R-f or
RFU 1Rx 2
15HPA-1R-RFU-11
OCB with filters 15OCBfx-xxxY-aa-L/H 2

OCB Pole mount kit OCB-Pole Mount 1


15HP Short for WRccc Kit 15HP-SHORT-ccc 2
1500HP WG Termination, WRccc Kit 15HP-TERM-ccc 2
OCB Coupler f GHz OCB-CPLR-f 1

Procedure

1 Mount the termination and short flange on the rear side, as described in
Short Installation on page 17 and Termination Installation on page 18.

Ceragon Proprietary and Confidential Page 39 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

2 Mount the OCB to the OCB pole mount, as described in Pole Mount
Preliminary Assembly on page 14.

3 Mount the radio to the OCB, as described in Outdoor Branching Network


(OBM) Housing Hanging Procedure on page 25.

Ceragon Proprietary and Confidential Page 40 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

4 Attach a coupler to the OCBs and secure it with screws.

5 Attach the pole mount bracket to the pole, as described in Pole Mount
Preliminary Assembly on page 14.

Ceragon Proprietary and Confidential Page 41 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

18.5 2+0 DP

List of Items per Terminal

Description Marketing Model Quantity

RFU-HP-1R-f or
RFU 1Rx 2
15HPA-1R-RFU-11
OCB with filters 15OCBfx-xxxY-aa-L/H 2

OCB Pole mount kit OCB-Pole Mount 1


15HP Short for WRccc Kit 15HP-SHORT-ccc 2
1500HP WG Termination, WRccc Kit 15HP-TERM-ccc 2
Flexible WG Kit 3200T Flx WG xFT fGHz 2

Procedure

1 Mount the termination and short flange on the rear side, as described in
Short Installation on page 17 and Termination Installation on page 18.
2 Mount the OCB to the pole mount, as described in Pole Mount Preliminary
Assembly on page 14.
3 Mount the radio to the OCB, as described in Outdoor Branching Network
(OBM) Housing Hanging Procedure on page 25.

Ceragon Proprietary and Confidential Page 42 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

4 Attach the pole mount bracket to the pole, as described in Pole Mount
Preliminary Assembly on page 14.

5 Mount the flexible waveguide and O-ring to the MAIN (upper) port using
the screws and washers supplied in the Flexible Waveguide kit, as
described in Connecting a Flexible Waveguide on page 26.

Ceragon Proprietary and Confidential Page 43 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

6 Repeat the procedure for the second polarization.

Ceragon Proprietary and Confidential Page 44 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

18.6 2+0 SP

List of Items per Terminal

Description Marketing Model Quantity

RFU-HP-1R-f or
RFU 1Rx 2
15HPA-1R-RFU-11
OCB with filters 15OCBfx-xxxY-aa-L/H 2

OCB Pole mount kit OCB-Pole Mount 1


OCB-Sbend Kit OCB-SBend-f 1
1500HP WG Termination, WRccc Kit 15HP-TERM-ccc 1
15HP Short for WRccc Kit 15HP-SHORT-ccc 2
Flexible WG Kit 3200T Flx WG xFT fGHz 1

Procedure

1 Mount the OCBs to the OCB pole mount, as described in Pole Mount
Preliminary Assembly on page 14.
2 Slide and tighten both radios to the OCB, as described in Outdoor
Branching Network (OBM) Housing Hanging Procedure on page 25.

Ceragon Proprietary and Confidential Page 45 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

3 On the rear side, mount the termination and short to the OCB flanges, as
shown below and as described in Short Installation on page 17 and
Termination Installation on page 18.

4 Mount the S-Bend between the OCBs, as shown below and as described in
Installing S-Bends and the DCB on page 16.

5 Attach the OCB pole mount bracket to the pole, as described in Pole Mount
Preliminary Assembly on page 14.

Ceragon Proprietary and Confidential Page 46 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

6 Mount the flexible waveguide and O-ring to the MAIN (upper) port using
the screws and washers supplied in the Flexible Waveguide kit, as
described in Connecting a Flexible Waveguide on page 26.

Ceragon Proprietary and Confidential Page 47 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

18.7 2+0 SD SP

List of Items per Terminal

Description Marketing Model Quantity

RFU 2Rx 15HPA-2R-RFU-f 2


OCB 2Rx with filters 15OCBfx-SD-xxxY-aa-L/H 2
OCB Pole mount kit OCB-Pole Mount 1

1500HP WG Termination, WRccc Kit 15HP-TERM-ccc 2


OCB-Sbend Kit OCB-SBend-f 1
DCB Diversity Block fxGHz kit DCBfx 1
Flexible WG Kit 3200T Flx WG xFT fGHz 2

Procedure

1 Mount the OCBs to the OCB pole mount, as described in Pole Mount
Preliminary Assembly on page 14.
2 Slide and tighten both radios to the OCB, as described in Outdoor
Branching Network (OBM) Housing Hanging Procedure on page 25.

Ceragon Proprietary and Confidential Page 48 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

3 On the rear side, mount the termination flange, as shown below and as
described in Termination Installation on page 18.

4 Mount the S-Bend and DCB to the OCBs, as shown below and as described
in Installing S-Bends and the DCB on page 16.

Ceragon Proprietary and Confidential Page 49 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

5 Mount the termination to the DCB, as shown below and described in


Termination Installation on page 18.

6 Attach the OCB pole mount bracket to the pole, as described in Pole Mount
Preliminary Assembly on page 14.
7 Mount the flexible waveguide and O-ring to the MAIN (upper) port using
the screws and washers supplied in the Flexible Waveguide kit, as
described in Connecting a Flexible Waveguide on page 26.

Ceragon Proprietary and Confidential Page 50 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

18.8 2+0 SD DP

List of Items per Terminal

Description Marketing Model Quantity

RFU 2Rx 15HPA-2R-RFU-f 2


OCB 2Rx with filters 15OCBfx-SD-xxxY-aa-L/H 2
OCB Pole mount kit OCB-Pole Mount 1

1500HP WG Termination, WRccc Kit 15HP-TERM-ccc 2


Flexible WG Kit 3200T Flx WG xFT fGHz 4

Procedure

1 Mount the termination and short flange on the rear side, as described in
Short Installation on page 17 and Termination Installation on page 18.
2 Mount the OCB to the OCB pole mount, as described in Pole Mount
Preliminary Assembly on page 14.
3 Mount the radio to the OCB, as described in Outdoor Branching Network
(OBM) Housing Hanging Procedure on page 25.

Ceragon Proprietary and Confidential Page 51 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

4 Attach the pole mount bracket to the pole, as described in Pole Mount
Preliminary Assembly on page 14.

5 Mount the flexible waveguide and O-ring to the MAIN (upper) port using
the screws and washers supplied in the Flexible Waveguide kit, as
described in Connecting a Flexible Waveguide on page 26.

Ceragon Proprietary and Confidential Page 52 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

6 Repeat the procedure for the second polarization.

Ceragon Proprietary and Confidential Page 53 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

18.9 2+2 SD SP

List of Items per Terminal

Description Marketing Model Quantity

RFU 2Rx 15HPA-2R-RFU-f 4


OCB 2Rx with filters 15OCBfx-SD-xxxY-aa-L/H 4
OCB-Sbend OCB-SBend-f 2

DCB Diversity Block fxGHz kit DCBfx 2


OCB Coupler f GHz OCB-CPLR-f 2
1500HP WG Termination, WRccc 15HP-TERM-ccc 4
ADPT WG/COAX CPR-ccc G-FLT F/N-
WRccc ADPT G-FLT to N-TYPE kit 1
TYPE KIT
LDF4-Jumper-15m,Andrew LDF4-JA-15M/ LDF 1

Flex. WG kit WR-ccc, 4 FT WAVEGUIDE-f-4FT 3


OCB-Pole Mount OCB-Pole Mount 1

Procedure

1 Attach the pole mount bracket to the pole, as described in Pole Mount
Preliminary Assembly on page 14
2 Mount the four OCBs to the pole mount bracket, as described in Pole Mount
Preliminary Assembly on page 14.
3 On the rear side, mount termination plates to the RX ports of the second
and fourth radios using the screws and washers supplied in the
termination kit, as described in Termination Installation on page 18.

Ceragon Proprietary and Confidential Page 54 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

4 Mount the four radios to the OCB, as described in Outdoor Branching


Network (OBM) Housing Hanging Procedure on page 25.

Ceragon Proprietary and Confidential Page 55 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

5 Mount two S-Bends; the first S-Bend between the EXT port of radio 1 and
the MAIN port of radio 2, and the second S-Bend between the EXT port of
radio 3 and the MAIN port of radio 4. See Installing S-Bends and the DCB on
page 16.

Ceragon Proprietary and Confidential Page 56 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

6 Mount two DCBs; the first DCB between the DIV ports of radio 1 and radio
2, and the second between the DIV ports of radio 3 and radio 4. See
Installing S-Bends and the DCB on page 16.

Ceragon Proprietary and Confidential Page 57 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

7 Mount two couplers, one to the MAIN port of radio 1 and the other to the
left port of the left DCB, as described in Installing Couplers on page 15.

Ceragon Proprietary and Confidential Page 58 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

8 Mount two terminations to the right ports of both DCBs using the screws
and washers supplied with the termination kit, as described in
Termination Installation on page 18.

Ceragon Proprietary and Confidential Page 59 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

9 Mount a flexible waveguide with O-ring between the MAIN port in radio 3
and the Coupler port on the top coupler using the screws and washers
supplied with the Flexible Waveguide kit, as described in Connecting a
Flexible Waveguide on page 26.

Ceragon Proprietary and Confidential Page 60 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

10 Mount a flexible waveguide with O-ring between the left port in the right
DCB and the Coupler port on the bottom coupler using the screws and
washers supplied with the Flexible Waveguide kit, as described in
Connecting a Flexible Waveguide on page 26.

Ceragon Proprietary and Confidential Page 61 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

11 Mount a flexible waveguide with O-ring between the main antenna and the
Antenna port on the top coupler using the screws and washers supplied
with the Flexible Waveguide kit, as described in Connecting a Flexible
Waveguide on page 26.

Ceragon Proprietary and Confidential Page 62 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

12 If the diversity antenna is connected with a coax cable, connect a


waveguide to coax adapter on the diversity coupler and connect the coax
to the diversity antenna.

Ceragon Proprietary and Confidential Page 63 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

If a waveguide connection is to be used, connect a waveguide directly to


the Coupler port and the diversity antenna.

Ceragon Proprietary and Confidential Page 64 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

18.10 2+2 SD DP (Non-Upgradable)

List of Items per Terminal

Description Marketing Model Quantity

RFU 2Rx 15HPA-2R-RFU-f 4


OCB 2Rx with filters 15OCBfx-SD-xxxY-aa-L/H 4
OCB Pole mount kit OCB-Pole Mount 1

1500HP WG Termination, WRccc Kit 15HP-TERM-ccc 4


OCB Coupler f GHz OCB-CPLR-f 4

Procedure

1 Mount the terminations on the rear side, as described in Termination


Installation on page 18.

Ceragon Proprietary and Confidential Page 65 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

2 Mount the OCB to the OCB pole mount, as described in Pole Mount
Preliminary Assembly on page 14.

3 Mount the radio to the OCB, as described in Outdoor Branching Network


(OBM) Housing Hanging Procedure on page 25.

Ceragon Proprietary and Confidential Page 66 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

4 Attach a coupler to the left two main OCB waveguides and secure it with
screws.

5 Attach a coupler to the left two Div OCB waveguides and secure it with
screws.

Ceragon Proprietary and Confidential Page 67 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

6 Attach a coupler to the right two main OCB waveguides and secure it with
screws.

7 Attach a coupler to the right two Div OCB waveguides and secure it with
screws.

Ceragon Proprietary and Confidential Page 68 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

8 Attach the pole mount bracket to the pole, as described in Pole Mount
Preliminary Assembly on page 14.

Ceragon Proprietary and Confidential Page 69 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

18.11 2+2 HSB DP (Ready for Upgrade)

List of Items per Terminal

Description Marketing Model Quantity

RFU-HP-1R-f or
RFU 1Rx 4
15HPA-1R-RFU-11
OCB with filters 15OCBfx-xxxY-aa-L/H 4

OCB Pole mount kit OCB-Pole Mount 1


1500HP WG Termination, WRccc Kit 15HP-TERM-ccc 4
OCB Coupler f GHz OCB-CPLR-f 2

Procedure

1 Mount the terminations on the rear side, as described in Termination


Installation on page 18.

Ceragon Proprietary and Confidential Page 70 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

2 Mount two of the OCBs to the OCB pole mount bracket, as described in Pole
Mount Preliminary Assembly on page 14.

3 Mount the radios to the OCBs, as described in Outdoor Branching Network


(OBM) Housing Hanging Procedure on page 25.

Ceragon Proprietary and Confidential Page 71 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

4 Attach a coupler to both radios and secure it with screws.

5 Attach the pole mount bracket to the pole, as described in Pole Mount
Preliminary Assembly on page 14.

Ceragon Proprietary and Confidential Page 72 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

6 Repeat steps 1 through 4.

7 Attach the pole mount bracket to the pole mount, as described in Pole
Mount Preliminary Assembly on page 14.

Ceragon Proprietary and Confidential Page 73 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

18.12 2+2 HSB DP (Non-Upgradable)

List of Items per Terminal

Description Marketing Model Quantity

RFU-HP-1R-f or
RFU 1Rx 4
15HPA-1R-RFU-11
OCB with filters 15OCBfx-xxxY-aa-L/H 4

OCB Pole mount kit OCB-Pole Mount 1


1500HP WG Termination, WRccc Kit 15HP-TERM-ccc 4
OCB Coupler f GHz OCB-CPLR-f 2

Procedure

1 Mount the terminations on the rear side, as described in Termination


Installation on page 18.

Ceragon Proprietary and Confidential Page 74 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

2 Mount the OCB to the OCB pole mount bracket, as described in Pole Mount
Preliminary Assembly on page 14.

3 Mount the radios to the OCBs, as described in Outdoor Branching Network


(OBM) Housing Hanging Procedure on page 25.

Ceragon Proprietary and Confidential Page 75 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

4 Attach a coupler to both left radios and secure it with screws.

5 Attach a coupler to both right radios and secure it with screws.

Ceragon Proprietary and Confidential Page 76 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

6 Attach the pole mount bracket to the pole mount, as described in Pole
Mount Preliminary Assembly on page 14.

Ceragon Proprietary and Confidential Page 77 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

18.13 2+2 HSB SP

List of Items per Terminal

Description Marketing Model Quantity

RFU-HP-1R-f or
RFU 1Rx 4
15HPA-1R-RFU-11
OCB with filters 15OCBfx-xxxY-aa-L/H 4

OCB-Sbend OCB-SBend-f 2
1500HP WG Termination, WRccc 15HP-TERM-ccc 2
15HP Short for WRccc 15HP-SHORT-ccc 4
OCB Coupler f GHz OCB-CPLR-f 1

Flex. WG kit WR-ccc, 4 FT WAVEGUIDE-f-4FT 2

OCB-Pole Mount OCB-Pole Mount 1

Procedure

1 Attach the pole mount bracket to the pole, as described in Pole Mount
Preliminary Assembly on page 14.
2 Mount the four OCBs to the pole mount bracket, as described in Pole Mount
Preliminary Assembly on page 14.
3 On the rear side, mount termination plates to the EXT ports of the second
and fourth radios using the screws and washers supplied in the
termination kit, as described in Termination Installation on page 18.
4 On the rear side, mount shorts to the DIV ports of all four radios using the
screws and washers supplied in the short kit, as described in Short
Installation on page 17.

Ceragon Proprietary and Confidential Page 78 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

5 Mount the four radios to the OCB, as described in Outdoor Branching


Network (OBM) Housing Hanging Procedure on page 25.

Ceragon Proprietary and Confidential Page 79 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

6 Mount two S-Bends; the first S-Bend between the EXT port of radio 1 and
the MAIN port of radio 2, and the second S-Bend between the EXT port of
radio 3 and the MAIN port of radio 4. See Installing S-Bends and the DCB on
page 16.

Ceragon Proprietary and Confidential Page 80 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

7 Mount the coupler to the MAIN port of radio 1, as described in Installing


Couplers on page 15.

Ceragon Proprietary and Confidential Page 81 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

8 Mount a flexible waveguide with O-ring between the MAIN port in radio 3
and the Coupler port on the coupler using the screws and washers
supplied with the Flexible Waveguide kit, as described in Connecting a
Flexible Waveguide on page 26.

Ceragon Proprietary and Confidential Page 82 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

9 Mount a flexible waveguide with O-ring between the antenna and the
Antenna port on the coupler, using the screws and washers supplied with
the Flexible Waveguide kit, as described in Connecting a Flexible
Waveguide on page 26.

Ceragon Proprietary and Confidential Page 83 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

19. Upgrade Instructions

19.1 Upgrading from 1+1 SD to 2+2 SD SP

List of Additional Items per Terminal

Description Marketing Model Quantity

RFU 2 Rx 15HPA-2R-RFU-f 2
OCB 2Rx with filters 15OCBfx-SD-xxxY-aa-L/H 2

OCB-Sbend OCB-SBend-f 2
DCB Diversity Block fxGHz kit DCBfx 2
1500HP WG Termination, WRccc 15HP-TERM-ccc 2
Flex. WG kit WR-ccc, 4 FT WAVEGUIDE-f-4FT 2
OCB-Pole Mount OCB-Pole Mount 1

Procedure

1 Start with a 1+1 SD configuration.

2 On the rear side, disassemble the termination from the EXT port on
radio 1.

Ceragon Proprietary and Confidential Page 84 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

3 On the rear side, disassemble both couplers.

4 On the rear side of the new radios, mount the termination to the EXT port
of the fourth radio using the screws and washers supplied in the
termination kit, as described in Termination Installation on page 18.

Ceragon Proprietary and Confidential Page 85 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

5 Mount the two new radios to the OCB, as described in Outdoor Branching
Network (OBM) Housing Hanging Procedure on page 25.

Ceragon Proprietary and Confidential Page 86 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

6 Mount two S-Bends; the first S-Bend between the EXT port of radio 1 and
the MAIN port of radio 2, and the second S-Bend between the EXT port of
radio 3 and the MAIN port of radio 4. See Installing S-Bends and the DCB on
page 16.

Ceragon Proprietary and Confidential Page 87 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

7 Mount two DCBs; the first DCB between the DIV ports of radio 1 and radio
2, and the second between the DIV ports of radio 3 and radio 4. See
Installing S-Bends and the DCB on page 16.

Ceragon Proprietary and Confidential Page 88 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

8 Mount two couplers, one to the MAIN port of radio 1 and the other to the
left port of the left DCB, as described in Installing Couplers on page 15.

Ceragon Proprietary and Confidential Page 89 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

9 Mount two terminations to the right ports of both DCBs using the screws
and washers supplied with the termination kit, as described in
Termination Installation on page 18.

Ceragon Proprietary and Confidential Page 90 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

10 Mount a flexible waveguide with O-ring between the MAIN port in radio 3
and the Coupler port on the top coupler using the screws and washers
supplied with the Flexible Waveguide kit, as described in Connecting a
Flexible Waveguide on page 26.

Ceragon Proprietary and Confidential Page 91 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

11 Mount a flexible waveguide with O-ring between the left port in the right
DCB and the Coupler port on the bottom coupler using the screws and
washers supplied with the Flexible Waveguide kit, as described in
Connecting a Flexible Waveguide on page 26.

Ceragon Proprietary and Confidential Page 92 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

12 Mount the flexible waveguide with O-ring between the main antenna and
the Antenna port on the top coupler using the screws and washers
supplied with the Flexible Waveguide kit, as described in Connecting a
Flexible Waveguide on page 26.

Ceragon Proprietary and Confidential Page 93 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

13 If the diversity antenna is connected with a coax cable, connect a


waveguide to coax adapter on the diversity coupler and connect the coax
to the diversity antenna.

Ceragon Proprietary and Confidential Page 94 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

If a waveguide connection is to be used, connect a waveguide directly to


the coupler port and the diversity antenna.

Ceragon Proprietary and Confidential Page 95 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

19.2 Upgrading from 1+1 HSB SP to 2+2 HSB SP

List of Additional Items per Terminal

Description Marketing Model Quantity

RFU-HP-1R-f or
RFU 1Rx 2
15HPA-1R-RFU-11
OCB with filters 15OCBfx-xxxY-aa-L/H 2

OCB-Sbend OCB-SBend-f 2
1500HP WG Termination, WRccc 15HP-TERM-ccc 2
15HP Short for WRccc 15HP-SHORT-ccc 2
Flex. WG kit WR-ccc, 4 FT WAVEGUIDE-f-4FT 1

Procedure

1 Start with a 1+1 HSB configuration.

2 On the rear side, disassemble the termination from the EXT port on
radio 1.

Ceragon Proprietary and Confidential Page 96 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

3 On the rear side, disassemble the coupler.

4 On the rear side of the two new radios, mount shorts to the DIV ports using
the screws and washers supplied in the short kit, as described in Short
Installation on page 17.
5 On the rear side of the new radios, mount termination plates to the EXT
port of the fourth radio using the screws and washers supplied in the
termination kit, as described in Termination Installation on page 18.

Ceragon Proprietary and Confidential Page 97 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

6 Mount the two new radios to the OCB, as described in Outdoor Branching
Network (OBM) Housing Hanging Procedure on page 25.

Ceragon Proprietary and Confidential Page 98 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

7 Mount two S-Bends; the first S-Bend between the EXT port of radio 1 and
the MAIN port of radio 2, and the second S-Bend between the EXT port of
radio 3 and the MAIN port of radio 4. See Installing S-Bends and the DCB on
page 16.

Ceragon Proprietary and Confidential Page 99 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

8 Mount the coupler to the MAIN port of radio 1, as described in Installing


Couplers on page 15.

Ceragon Proprietary and Confidential Page 100 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

9 Mount a flexible waveguide with O-ring between the MAIN port on radio 3
and the Coupler port on the coupler using the screws and washers
supplied with the Flexible Waveguide kit, as described in Connecting a
Flexible Waveguide on page 26.

Ceragon Proprietary and Confidential Page 101 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

10 Mount a flexible waveguide with O-ring between the antenna and the
Antenna port on the coupler, using the screws and washers supplied with
the Flexible Waveguide kit, as described in Connecting a Flexible
Waveguide on page 26.

Ceragon Proprietary and Confidential Page 102 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

19.3 Upgrading from 2+2 DP to 3+3 DP

List of Additional Items per Terminal

Description Marketing Model Quantity

RFU-HP-1R-f or
RFU 1Rx 2
15HPA-1R-RFU-11
OCB with filters 15OCBfx-xxxY-aa-L/H 2

OCB Pole mount kit OCB-Pole Mount 1


OCB-Sbend Kit OCB-SBend-f 2
15HP Short for WRccc Kit 15HP-SHORT-ccc 2
Flexible WG Kit 3200T Flx WG xFT fGHz 1

Procedure

1 Start with a 2+2 DP configuration.

Ceragon Proprietary and Confidential Page 103 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

2 Disconnect the couplers and the terminations on the first and third OCB.

3 Mount the S-Bend to the OCBs, as shown below and as described in


Installing S-Bends and the DCB on page 16.

Ceragon Proprietary and Confidential Page 104 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

4 Mount the coupler to the OCB, as shown below and as described in


Installing Couplers on page 15.

5 Mount the OCB to the pole mount, as described in Pole Mount Preliminary
Assembly on page 14.
6 Mount a flexible waveguide and O-ring to the MAIN (upper) port of the
OCB and the Coupling port of the coupler using the screws and washers
supplied with the Flexible Waveguide kit, as described in Connecting a
Flexible Waveguide on page 26.

Ceragon Proprietary and Confidential Page 105 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

7 Mount a flexible waveguide and O-ring to the antenna port of the coupler
using the screws and washers supplied with the Flexible Waveguide kit, as
described in Connecting a Flexible Waveguide on page 26.

8 On the second OCB pole mount, perform a mounting similar to a 1+1 HSB
configuration, as described in 1+1 HSB on page 39.

Ceragon Proprietary and Confidential Page 106 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

19.4 Upgrading from 2+2 SD SP to 3+3 SD SP

List of Additional Items per Terminal

Description Marketing Model Quantity

RFU 2Rx 15HPA-2R-RFU-f 3


OCB 2Rx with filters 15OCBfx-SD-xxxY-aa-L/H 3
OCB Pole mount kit OCB-Pole Mount 1

15HP Short for WRccc 15HP-SHORT-ccc 2


OCB-Sbend Kit OCB-SBend-f 2
DCB-UBend Kit DCB-UBend-f 2
DCB Diversity Block fxGHz kit DCBfx 2
ADPT WG/COAX CPR-ccc G-FLT
WRccc ADPT G-FLT to N-TYPE kit 1
F/N-TYPE KIT

Flex. WG kit WR-ccc, 4 FT WAVEGUIDE-f-4FT 3

Ceragon Proprietary and Confidential Page 107 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

Procedure

1 Start with a 2+2 SD SP configuration.

WG #3

WG #1
WG #2

Coax to WG

2 Remove the coax to waveguide and all three flexible waveguides (both
sides).

Ceragon Proprietary and Confidential Page 108 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

3 Remove the S-Bend, four terminations, and marked screws from the DCB.

S-Bend 2

WG #2

Remove 6
screws

WG #3
WG #1
WG #4

4 Remove the marked OCB.

OCB

Ceragon Proprietary and Confidential Page 109 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

5 Attach the S-Bend between the middle OCBs.

6 Mount a termination to the EXT port, as described in Termination


Installation on page 18.

Ceragon Proprietary and Confidential Page 110 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

7 Mount a short plate to the DCB, as described in Short Installation on


page 17.

8 Mount three of the OCBs to the OCB pole mount, as described in Pole
Mount Preliminary Assembly on page 14.

Ceragon Proprietary and Confidential Page 111 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

9 Mount the radios to the OCBs, as described in Outdoor Branching Network


(OBM) Housing Hanging Procedure on page 25.

10 Attach two S-bend to both left OCBs, as described in Installing S-Bends and
the DCB on page 16.

Ceragon Proprietary and Confidential Page 112 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

11 Attach two DCBs to both right OCBs, as described in Installing S-Bends and
the DCB on page 16.

12 Attach the U-Bend between the two DCBs.

Ceragon Proprietary and Confidential Page 113 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

13 Attach the two terminations, as described in Termination Installation on


page 18.

14 Attach short on the DCB, as described in Short Installation on page 17.

Ceragon Proprietary and Confidential Page 114 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

15 Attach the pole mount bracket to the pole mount beneath the 2+2 SD SP
assembly that is already installed, as described in Pole Mount Preliminary
Assembly on page 14.

Already
installed

Upgrade addition

16 Attach flexible waveguide 1 from the Main port of the radio to coupler 1.

Flexible WG #1

Coupler #1

Main Radio

Ceragon Proprietary and Confidential Page 115 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

17 Attach flexible waveguide 2 from the bottom DCB to coupler 2.

Flexible WG #2

Coupler #2

DCB

Ceragon Proprietary and Confidential Page 116 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

18 Mount a flexible waveguide with O-ring between the main antenna and the
Antenna port on the top coupler using the screws and washers supplied
with the Flexible Waveguide kit, as described in Connecting a Flexible
Waveguide on page 26.

Flexible WG to
Main antenna

Ceragon Proprietary and Confidential Page 117 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

19 If the diversity antenna is connected with a coax cable, connect a


waveguide to coax adapter on the diversity coupler and connect the coax
to the diversity antenna.

Coax to WG to
diversity antenna

If a waveguide connection is to be used, connect a waveguide directly to


the Coupler port and the diversity antenna.

Ceragon Proprietary and Confidential Page 118 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

19.5 Upgrading from 2+2 SD DP to 3+3 SD DP

List of Additional Items per Terminal

Description Marketing Model Quantity

RFU 2Rx 15HPA-2R-RFU-f 2


OCB 2Rx with filters 15OCBfx-SD-xxxY-aa-L/H 2
OCB Pole mount kit OCB-Pole Mount 1

OCB-Sbend Kit OCB-SBend-f 2


1500HP WG Termination, WRccc Kit 15HP-TERM-ccc 2
DCB Diversity Block fxGHz kit DCBfx 2
Flexible WG Kit 3200T Flx WG xFT fGHz 2

Procedure

1 Start with a 2+2 SD DP configuration.

Ceragon Proprietary and Confidential Page 119 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

2 Disconnect the couplers and the terminations on the first and third OCB.

3 Mount S-Bends and DCBs to the OCBs, as shown below and as described in
Installing S-Bends and the DCB on page 16.

Ceragon Proprietary and Confidential Page 120 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

4 Mount a termination to each DCB, as shown below and as described in


Termination Installation on page 18.

5 Mount the coupler to the OCB, as shown below and as described in


Installing Couplers on page 15.

6 Mount the OCB to the pole mount, as described in Pole Mount Preliminary
Assembly on page 14.

Ceragon Proprietary and Confidential Page 121 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

7 Mount a flexible waveguide and O-ring between the MAIN (upper) port of
both OCBs and the coupling port of the upper couplers using the screws
and washers supplied with the Flexible Waveguide kit, as described in
Connecting a Flexible Waveguide on page 26.

8 Mount a flexible waveguide and O-ring to the antenna port of each coupler
using the screws and washers supplied with the Flexible Waveguide kit, as
described in Connecting a Flexible Waveguide on page 26.

9 On the second OCB pole mount, perform a mounting similar to a 1+1 HSB
SD configuration, as described in 1+1 HSB on page 39.
Ceragon Proprietary and Confidential Page 122 of 167
FibeAir® 1500HP/RFU-HP Installation Guide

19.6 Upgrading from 2+2 HSB SP to 3+3 HSB SP

List of Additional Items per Terminal

Description Marketing Model Quantity

RFU-HP-1R-f or
RFU 1Rx 2
15HPA-1R-RFU-11
OCB with filters 15OCBfx-xxxY-aa-L/H 2

OCB-Sbend OCB-SBend-f 2
15HP Short for WRccc 15HP-SHORT-ccc 2
OCB-Pole Mount OCB-Pole Mount 1

Procedure

1 Start with a 2+2 HSB SP configuration.

Ceragon Proprietary and Confidential Page 123 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

2 Install an additional pole mount bracket on the pole beneath the existing
pole mount bracket, as described in Pole Mount Preliminary Assembly on
page 14.
3 Disconnect the flexible waveguides from the MAIN port on radio 3.
4 Disconnect the terminations from the EXT port on radio 2 and radio 4.
5 Disassemble OCB 3 with radio 3 and OCB 4 with radio 4 from the old pole
mount bracket.

Ceragon Proprietary and Confidential Page 124 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

6 Mount OCB 3 with radio 3 and OCB 4 with radio 4 on the new pole mount
bracket, as described in Pole Mount Preliminary Assembly on page 14.

7 For the two radios on the rear side, mount a termination plate to the EXT
ports using the screws and washers supplied in the termination kit, as
described in Termination Installation on page 18.

Ceragon Proprietary and Confidential Page 125 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

8 For the two new radios on the rear side, mount a short to the DIV ports
using screws and washers supplied in the short kit, as described in Short
Installation on page 17.
9 Mount one new radio to each pole mount bracket, as described in Outdoor
Branching Network (OBM) Housing Hanging Procedure on page 25.

Ceragon Proprietary and Confidential Page 126 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

10 Mount two S-Bends in the top and bottom assemblies; between the EXT
port of radio 2 and the MAIN port of radio 3, as described in Installing S-
Bends and the DCB on page 16.

Ceragon Proprietary and Confidential Page 127 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

11 Connect the loose side of the flexible waveguide with O-ring to the MAIN
port on radio 1 in the bottom assembly, as described in Connecting a
Flexible Waveguide on page 26.

Ceragon Proprietary and Confidential Page 128 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

Ceragon Proprietary and Confidential Page 129 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

19.7 Upgrading from 3+3 DP to 4+4 DP

List of Additional Items per Terminal

Description Marketing Model Quantity

RFU-HP-1R-f or
RFU 1Rx 2
15HPA-1R-RFU-11
OCB with filters 15OCBfx-xxxY-aa-L/H 2

OCB-Sbend Kit OCB-SBend-f 2


1500HP WG Termination, WRccc Kit 15HP-TERM-ccc 2
15HP Short for WRccc Kit 15HP-SHORT-ccc 2
Flexible WG Kit 3200T Flx WG xFT fGHz 1

Ceragon Proprietary and Confidential Page 130 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

Procedure

1 Start with a 3+3 DP configuration.

2 On the OCB pole with two OCBs, disconnect the coupler, add two OCBs, and
slide in two radios.

Ceragon Proprietary and Confidential Page 131 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

3 Mount the termination on the fourth OCB, as shown below and as


described in Termination Installation on page 18.

4 Mount the S-Bend to the OCBs, as shown below and as described in


Installing S-Bends and the DCB on page 16.

Ceragon Proprietary and Confidential Page 132 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

5 Mount the coupler to the OCBs, as shown below and as described in


Installing Couplers on page 15.

6 Mount the OCB to the pole mount, as described in Pole Mount Preliminary
Assembly on page 14.
7 Mount a flexible waveguide and O-ring between the MAIN (upper) port of
the OCB and the Coupling port of the coupler using the screws and
washers supplied with the Flexible Waveguide kit, as described in
Connecting a Flexible Waveguide on page 26.

Ceragon Proprietary and Confidential Page 133 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

8 Mount a flexible waveguide and O-ring to the antenna port of the coupler
using the screws and washers supplied with the Flexible Waveguide kit, as
described in Connecting a Flexible Waveguide on page 26.

Ceragon Proprietary and Confidential Page 134 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

19.8 Upgrading from 3+3 SD DP to 4+4 SD DP

List of Additional Items per Terminal

Description Marketing Model Quantity

RFU 2Rx 15HPA-2R-RFU-f 2


OCB 2Rx with filters 15OCBfx-SD-xxxY-aa-L/H 2
OCB-Sbend Kit OCB-SBend-f 2

1500HP WG Termination, WRccc Kit 15HP-TERM-ccc 2


DCB Diversity Block fxGHz kit DCBfx 2
Flexible WG Kit 3200T Flx WG xFT fGHz 2

Ceragon Proprietary and Confidential Page 135 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

Procedure

1 Start with a 3+3 SD DP configuration.

Ceragon Proprietary and Confidential Page 136 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

2 On the OCB pole with two OCBs, disconnect both couplers, add two OCBs,
and slide in two radios as shown below.

3 Mount S-Bends and DCBs to the OCBs, as shown below and as described in
Installing S-Bends and the DCB on page 16.

Ceragon Proprietary and Confidential Page 137 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

4 Mount a termination to each DCB, as shown below and as described in


Termination Installation on page 18.

5 Mount the coupler to the OCB, as shown below and as described in


Installing Couplers on page 15.

6 Mount the OCB to the pole mount, as described in Pole Mount Preliminary
Assembly on page 14.

Ceragon Proprietary and Confidential Page 138 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

7 Mount a flexible waveguide and O-ring between the MAIN (upper) port of
both OCBs and the coupling port of the upper couplers using the screws
and washers supplied with the Flexible Waveguide kit, as described in
Connecting a Flexible Waveguide on page 26.

8 Mount a flexible waveguide and O-ring to the antenna port of each coupler
using the screws and washers supplied with the Flexible Waveguide kit, as
described in Connecting a Flexible Waveguide on page 26.

Ceragon Proprietary and Confidential Page 139 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

19.9 Upgrading from 3+3 SD SP to 4+4 SD SP

List of Additional Items per Terminal

Description Marketing Model Quantity

RFU 2Rx 15HPA-2R-RFU-f 1


OCB 2Rx with filters 15OCBfx-SD-xxxY-aa-L/H 1
OCB-Sbend OCB-SBend-f 2

Procedure

1 Start with a 3+3 SD SP configuration.

Ceragon Proprietary and Confidential Page 140 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

2 Remove the two shorts from the DCBs.

3 Mount an OCB on each of the hanging profiles, as described in Pole Mount


Preliminary Assembly on page 14.

Ceragon Proprietary and Confidential Page 141 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

4 Tighten the screws between both DCBs and the assembled OCBs.

5 Mount the radio to the OCBs, as described in Outdoor Branching Network


(OBM) Housing Hanging Procedure on page 25.

Ceragon Proprietary and Confidential Page 142 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

6 Attach an S-bend between the new OCB and the one close to it. Do this for
both pole mounts.

7 Mount two terminations to the new OCBs, as described in Termination


Installation on page 18.

Ceragon Proprietary and Confidential Page 143 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

19.10 Upgrading from 3+3 HSB SP to 4+4 HSB SP

List of Additional Items per Terminal

Description Marketing Model Quantity

RFU-HP-1R-f or
RFU 1Rx 2
15HPA-1R-RFU-11
OCB with filters 15OCBfx-xxxY-aa-L/H 2

OCB-Sbend OCB-SBend-f 2
15HP Short for WRccc 15HP-SHORT-ccc 2

Procedure

1 Start with a 3+3 HSB configuration.

Ceragon Proprietary and Confidential Page 144 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

2 Disconnect the terminations from the EXT port on radio 3 in the bottom
and top assemblies.

3 For the two new radios on the rear side, mount terminations to the EXT
ports using screws and washers supplied in the termination kit, as
described in Termination Installation on page 18.
4 For the two new radios on the rear side, mount shorts to the DIV ports
using screws and washers supplied in short kit, as described in Short
Installation on page 17.

Ceragon Proprietary and Confidential Page 145 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

5 Mount one new radio to each pole mount bracket, as described in Outdoor
Branching Network (OBM) Housing Hanging Procedure on page 25.

Ceragon Proprietary and Confidential Page 146 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

6 Mount two S-Bends in the top and bottom assemblies between the EXT
port of radio 3 and the MAIN port of radio 4, as described in Installing S-
Bends and the DCB on page 16.

Ceragon Proprietary and Confidential Page 147 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

Ceragon Proprietary and Confidential Page 148 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

20. Split Trunk Configurations


Split trunk is when multiple carriers are chained together and are connected
to one antenna. This section describes common configurations for multiple
channels.

20.1 1+1/2+2 HSB Configurations

1+1 HSB 2+2 HSB XPIC

1+1 HSB SD 2+2 HSB XPIC SD

HSB Configurations (1+1/2+2)

Configuration OCB DCB U-bend S-bend Coupler 3dB Coupler Term. Cover/Short Pole Mount
1+1 HSB 2 0 0 0 1 0 2 2 1
1+1 HSB SD 2 0 0 0 2 0 2 0 1
2+2 XPIC HSB 4 0 0 0 2 0 4 4 1
2+2 XPIC HSB SD 4 0 0 0 4 0 4 0 4

Ceragon Proprietary and Confidential Page 149 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

20.2 N+0/N+1 Single Pole Configurations (N = 1 to 5)

1+0 1+1/2+0 2+1/3+0

3+1/4+0 4+1/5+0

1+0 SD 1+1/2+0 SD 2+1/3+0 SD

3+1/4+0 SD 4+1/5+0 SD

Ceragon Proprietary and Confidential Page 150 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

Single Pole Configurations N+0/N+1 (N = 1 to 5)

Configuration OCB DCB U-bend S-bend Term. Cover/Short Pole Mount


1+0 1 0 0 0 1 1 1
1+0 SD 1 0 0 0 1 0 1
1+1/2+0 2 0 0 1 1 2 1
1+1/2+0 SD 2 1 0 1 1 0 1
2+1/3+0 3 0 0 2 1 3 1
2+1/3+0 SD 3 2 1 2 2 1 1
3+1/4+0 4 0 0 3 1 4 1
3+1/4+0 SD 4 2 1 3 2 0 1
4+1/5+0 5 0 0 4 1 5 1
4+1/5+0 SD 5 3 2 4 2 1 1

Ceragon Proprietary and Confidential Page 151 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

20.3 N+0/N+1 CCDP Configurations (N = 1 to 5)

2+0 XPIC 2+1 XPIC 3+1 XPIC

4+1 XPIC

2+0 XPIC SD 2+1 XPIC SD

Ceragon Proprietary and Confidential Page 152 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

3+1 XPIC SD 4+1 XPIC SD

CCDP Configurations N+0/N+1 (N = 1 to 5)

Configuration OCB DCB U-bend S-bend Term. Cover/Short Pole Mount


2+0 XPIC 2 0 0 0 2 2 1
2+0 XPIC SD 2 0 0 0 2 0 1
2+1 XPIC 3 0 0 1 2 3 1
2+1 XPIC SD 3 1 0 1 3 0 1
3+1 XPIC 4 0 0 2 3 4 1
3+1 XPIC SD 4 2 0 2 4 0 1
4+1 XPIC 5 0 0 3 2 5 1
4+1 XPIC SD 5 3 1 3 4 1 1

Ceragon Proprietary and Confidential Page 153 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

20.4 N+0/N+1 CCDP Configurations (N = 5 to 10)

5+1 XPIC 6+1 XPIC 7+1 XPIC

8+1 XPIC 9+1 XPIC

Ceragon Proprietary and Confidential Page 154 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

5+1 XPIC SD 6+1 XPIC SD

7+1 XPIC SD 8+1 XPIC SD

Ceragon Proprietary and Confidential Page 155 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

9+1 XPIC SD

CCDP Configurations N+0/N+1 (N = 5 to 10)

Configuration OCB DCB U-bend S-bend Term. Cover/Short Pole Mount


5+1 XPIC 6 0 0 4 2 6 2
5+1 XPIC SD 6 4 2 4 4 2 2
6+1 XPIC 7 0 0 5 2 7 2
6+1 XPIC SD 7 4 2 5 4 1 2
7+1 XPIC 8 0 0 6 2 8 2
7+1 XPIC SD 8 4 2 6 4 0 2
8+1 XPIC 9 0 0 7 2 9 2
8+1 XPIC SD 9 5 3 7 4 1 2
9+1 XPIC 10 0 0 8 2 10 2
9+1 XPIC SD 10 6 4 8 4 2 2

Ceragon Proprietary and Confidential Page 156 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

21. All Indoor Horizontal Installation


Note: These configurations are only available for North American
installations.
For minimal rack space usage, the OCB can be installed in a 19” rack (open
rack, frame rack) in a horizontal position.
Note that this installation type and configuration does not require a fan tray.
The All-Indoor horizontal placement is available for the following
configurations:
 1+0
 1+0 East/West
 1+1
 1+1 East/West
The IDU can be installed above or below the RFUs as shown in the following
illustrations.
1+1 SD IP-10

1+0 IP-10

Ceragon Proprietary and Confidential Page 157 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

21.1 1+0 Installation

21.1.1 Parts Used


Picture Item Number Description QTY P/N
JC-0061-
1 Washer Flat for M6 8
0
JA-0150-
2 Screw Pan Head M6 x 16 8
0
JC-0062-
3 Washer Helical Spring for M6 8
0
Screw Socket Head #10-32UNC JA-0192-
4 16
x 7/16" 0
JC-0026-
5 Washer Spring #10 16
0

21.1.2 Assembly
1 Insert the termination gaskets in their places on the OCB 19” Rack Adapter
(MK-3230-0), and fasten the Termination Plates to the Adapter using 16
screws (4 in the table above) and 16 washers (3), as shown in the
following illustration.

Ceragon Proprietary and Confidential Page 158 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

2 Fasten the left bracket to the OCB 19” Rack Adapter (MK-3230-0) using 8
screws (number 2 in the table above) 8 washers (3), and another 8
washers (1), as shown in the following illustration.

3 Repeat step 2 above for the right bracket.

Ceragon Proprietary and Confidential Page 159 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

The following illustrations show the New OCB assembled with the 19” Rack
Adapter.

Ceragon Proprietary and Confidential Page 160 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

21.2 1+0 East-West Installation

21.2.1 Parts Used

Picture Item Number Description QTY P/N


JC-0061-
1 Washer Flat for M6 16
0
JA-0150-
2 Screw Pan Head M6 x 16 16
0
JC-0062-
3 Washer Helical Spring for M6 16
0
Screw Socket Head #10-32UNC JA-0192-
4 32
x 7/16" 0
JC-0026-
5 Washer Spring #10 32
0

21.2.2 Assembly
1 Insert the termination gaskets in their places on the OCB 19” Rack Adapter
(MK-3230-0), and fasten the Termination Plates to the Adapter using 24
screws (4 in the table above) and 24 washers (3), as shown in the
following illustration.

2 Fasten the left bracket to the OCB 19” Rack Adapter (MK-3230-0) using 8
screws (number 2 in the table above) 8 washers (3), and another 8
washers (1), as shown in the following illustration.

Ceragon Proprietary and Confidential Page 161 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

3 Repeat step 2 above for the right bracket.

Ceragon Proprietary and Confidential Page 162 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

The following illustrations show the New OCB assembled with the 19” Rack
Adapter.

Ceragon Proprietary and Confidential Page 163 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

21.3 1+1 HSB (Hot Standby) Installation

21.3.1 Parts Used

Picture Item Number Description QTY P/N


JC-0061-
1 Washer Flat for M6 16
0
JA-0150-
2 Screw Pan Head M6 x 16 16
0
JC-0062-
3 Washer Helical Spring for M6 16
0
Screw Socket Head #10-32UNC JA-0192-
4 32
x 7/16" 0
JC-0026-
5 Washer Spring #10 42
0
Screw Socket Head #10-32UNC JA-0123-
6 10
x 1/2" 0

21.3.2 Assembly
1 Insert the termination gaskets in their places on the OCB 19” Rack Adapter
(MK-3230-0), and fasten the Termination Plates to the Adapter using 24
screws (4 in the table above) and 24 washers (3), as shown in the
following illustration.

Ceragon Proprietary and Confidential Page 164 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

2 Fasten the left bracket to the OCB 19” Rack Adapter (MK-3230-0) using 8
screws (number 2 in the table above) 8 washers (3), and another 8
washers (1), as shown in the following illustration.

3 Repeat step 2 above for the right bracket.

Ceragon Proprietary and Confidential Page 165 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

4 Fasten the HSB Coupler to the New OCB 19” Rack Adapter Main Terminals
using 10 screws (number 4 in the table above), and 10 washers (5), as
shown in the following illustration.

The following illustrations show the New OCB assembled with the 19” Rack
Adapter.

Ceragon Proprietary and Confidential Page 166 of 167


FibeAir® 1500HP/RFU-HP Installation Guide

22. Appendix A: Electrical Diagrams

Ceragon Proprietary and Confidential Page 167 of 167


Initial Installations
Following are the Initial Installations configurations:
1. 1+0 SP
1+0 Sp DP
2. 2+0 DP
2+0 SD DP
3. 2+0 SP
20+ SD DP
4. 1+1 HSB SD DP
5. 2+2 SD SP
6. 2+2 HSB SP
1+0 SP
OCB kit
RFU
TX Antenna

Term.
RX

Short
RX

1+0 SD SP
OCB kit
RFU
TX Antenna
Term.

RX

Antenna
RX
Div.
2+0 DP
OCB kit
RFU
Antenna
TX
V

Term.
RX

Short
RX

OCB kit
RFU
Antenna
TX
H

Term.
RX
Short

RX

2+0 SD DP
OCB kit
RFU
Antenna
TX
Main V
Term.

RX

Antenna
RX
Div. V

OCB kit
RFU
Antenna
TX
Main H
Term.

RX

Antenna
RX
Div. H
2+0 SP
OCB kit
RFU
TX Antenna

RX

S-Bend WG
Short
RX

OCB kit
RFU
TX Term.

RX
Short

RX

2+0 SD SP
OCB kit
RFU
Antenna
TX
Main
RX
S-Bend WG

RX

OCB kit
RFU
TX Antenna
Div.
DCB
Term.

RX
Term.

RX
1+1 HSB SP

OCB kit
RFU
TX Antenna
Term.

RX Coupler
Short

RX

OCB kit
RFU
TX
Term.

RX
Short

RX

Duplicate for 2+2 HSB DP


(same set for V & H polarizations)
1+1 HSB SD SP
OCB kit
RFU
TX Antenna

Coupler
Term.

RX

Antenna
RX
Div.

OCB kit
RFU
Coupler

TX
Term.

RX

RX

Duplicate for 2+2 SD DP


(same set for V & H polarizations)
2+2 SD SP
OCB kit
RFU
Antenna
TX
Main
RX

Coupler
S-Bend WG
RX

OCB kit
RFU
TX
Antenna
Div.
Term.

RX
DCB

Term.
RX Coupler

OCB kit
RFU
G
xW
TX Fle

RX
S-Bend WG

RX
Flex WG

OCB kit
RFU
TX
Term.

RX
DCB

Term.
RX
2+2 HSB SP
OCB kit
RFU
TX Antenna

RX

Coupler
S-Bend WG
Short
RX

OCB kit
RFU
TX
Term.

RX
Short

RX
Flex WG

OCB kit
RFU
TX

RX
S-Bend WG
Short

RX

OCB kit
RFU
TX
Term.

RX
Short

RX
Installations Upgrades
Following are the Installations Upgrades configurations:
1. From 1+1 HSB
to
2+2 HSB SP
to
3+3 HSB SP
to
4+4 HSB SP

From 1+1 HSB


to
2+2 HSB DP
to
3+3 HSB DP
to
4+4 HSB DP
2. From 1+1 SD SP
to
2+2 SD SP
to
3+3 SD SP
to
4+4 SD SP

From 1+1 SD SP
to
2+2 SD DP
to
3+3 SD DP
to
4+4 SD DP
1+1 HSB SP 2+2 HSB SP 3+3 HSB SP 4+4 HSB SP

OCB kit OCB kit OCB kit OCB kit


RFU RFU RFU RFU
TX Antenna TX Antenna TX Antenna TX Antenna

RX

Term.
RX RX RX

Reused RFU/ BN

Reused RFU/ BN

Coupler
Coupler
Coupler

S-Bend WG
Coupler
Added Acc.:

S-Bend WG

S-Bend WG

Short
RX

Short
Short
RX

Short
RX RX
2x S-Bend WG
1x Flex WG
OCB kit OCB kit OCB kit
OCB kit RFU

Reused RFU/ BN
Existing Pole Mount
RFU RFU RFU
TX TX
TX TX

RX

Term.
Term.

RX RX RX

Existing Pole Mount


S-Bend WG
Existing Pole Mount

S-Bend WG

Short
RX

Short
RX

Short
Short

RX RX

Flex WG
OCB kit OCB kit OCB kit
RFU

Added RFU/ BN
RFU RFU

Flex WG
TX
TX TX

Flex WG
RX

Term.
RX RX

Added RFU/ BN

S-Bend WG
Short
S-Bend WG
RX

Short
Short
RX RX

OCB kit
OCB kit RFU

Added RFU/ BN
RFU
OCB kit Added Acc.: TX
TX RFU
1x Pole Mount kit
TX 2x S-Bend WG

Term.
RX

Term.
RX

RX

Short
RX

Reused RFU/ BN
Short
RX

S-Bend WG
Short
RX

(requires whenever RFU>5)


Added Acc.:

Additional Pole Mount


OCB kit 2x S-Bend WG
OCB kit RFU
RFU
TX
TX

RX
RX

S-Bend WG
Short
RX

S-Bend WG
Short
RX

OCB kit
RFU

Reused RFU/ BN
OCB kit
RFU

Added RFU/ BN
TX
TX

(requires whenever RFU>5)


RX

Additional Pole Mount


Term.
RX

S-Bend WG
Short
RX

Short
RX

OCB kit
RFU
TX

RX

S-Bend WG
Short
RX

OCB kit
RFU

Added RFU/ BN
TX

Term.
RX

Short
RX

2+2 HSB DP 3+3 HSB DP 4+4 HSB DP


OCB kit OCB kit OCB kit
RFU RFU RFU
Antenna Antenna Antenna
TX TX TX
V V V
Term.

RX RX RX
Coupler

Coupler

Coupler
No Change

Added Acc.:
S-Bend WG

S-Bend WG
Short

RX
Short

Short
RX RX
2x S-Bend WG
1x Flex WG
OCB kit OCB kit OCB kit
RFU RFU RFU
TX TX TX
Reused RFU/ BN
Term.

Term.

Term.
RX RX RX

No Change
Existing Pole Mount

Existing Pole Mount

Existing Pole Mount


Short

Short

Short
RX RX RX
Flex WG

Flex WG
OCB kit
RFU OCB kit OCB kit
Antenna RFU RFU
TX
H TX TX
Term.

RX
RX RX
Added RFU/ BN

Coupler
Short

RX
S-Bend WG

S-Bend WG
Short

Short
RX RX

OCB kit OCB kit OCB kit


RFU RFU RFU
TX
TX TX
Term.

RX
Term.

Term.
RX RX
Short

RX
Short

Short
RX RX

OCB kit OCB kit


RFU RFU
Antenna Antenna
TX TX
V H
(requires whenever RFU>5)
Term.

RX RX
Additional Pole Mount

Reused RFU/ BN
Added RFU/ BN

Coupler
Coupler

S-Bend WG
Short
Short

RX RX

OCB kit OCB kit


RFU RFU
TX TX

Term.
Term.

RX

Existing Pole Mount


RX
Short

RX
Short

RX
Flex WG

OCB kit
RFU
TX

RX
S-Bend WG

Added Acc.:
Short

RX
Added

1x S-Bend WG
1x Flex WG
OCB kit
RFU
TX
Term.

RX
Short

RX
1+1 SD SP 2+2 SD SP 3+3 SD SP 4+4 SD SP
OCB kit OCB kit OCB kit
OCB kit RFU RFU RFU
RFU Antenna Antenna Antenna
Antenna TX TX TX
TX Main Main Main
Main

Coupler
RX RX RX

Term.
RX

Coupler

Coupler
Reused RFUs

Coupler

S-Bend WG

S-Bend WG
S-Bend WG
RX RX RX
Antenna
RX
Div.
OCB kit OCB kit OCB kit
OCB kit RFU RFU RFU

Existing Pole Mount


RFU

Reused RFUs
TX TX

Coupler
TX
Antenna Antenna Antenna

Existing Pole Mount


TX
Div. Div. Div.

Existing Pole Mount


Term.
RX RX

DCB

DCB
RX

DCB
Term.
RX

S-Bend WG

S-Bend WG
Term.
RX RX RX

Coupler

Coupler
Coupler

Reused RFUs
RX

U-Bend WG

U-Bend WG
OCB kit OCB kit OCB kit
RFU RFU RFU
G
xW
Fle
TX TX TX

Term.
RX Added Acc.: RX RX
2x S-Bend WG

S-Bend WG

S-Bend WG
Added RFUs
RX 2x DCB RX RX

Flex WG
1x Coupler

DCB

DCB
1x Flex WG
OCB kit Added Acc.: OCB kit
RFU Short Term.
2x S-Bend WG RFU Term.

TX 2x DCB TX

Added RFU
OCB kit

Gs
RFU 2x U-Bend

W
Term.

x
RX

Term.
DCB

Gs
RX

Fle
TX

Flex W
Term.
RX RX
RX

S-Bend WG
RX
OCB kit
RFU

(requires whenever RFU>5)


OCB kit

Additional Pole Mount


TX
RFU
TX Added Acc.:
RX
2x S-Bend WG

S-Bend WG
RX

DCB
RX

S-Bend WG
RX
OCB kit

Added RFUs
RFU

U-Bend WG
OCB kit TX

Reused RFUs
RFU

Existing Pole Mount


TX RX

DCB
S-Bend WG
Term.
RX RX

RX
OCB kit

U-Bend WG
RFU

DCB
TX
Short Term.

RX

S-Bend WG
RX

DCB
OCB kit
RFU Term.

TX

Added RFU

Term.
RX

RX

2+2 SD DP 3+3 SD DP 4+4 SD DP


OCB kit OCB kit
OCB kit RFU RFU
RFU Antenna Antenna
Antenna TX
Main V
TX
TX Main V
Main V
Coupler

RX RX
Term.

RX

Coupler

Coupler
S-Bend WG

S-Bend WG
Antenna RX RX
NO Change

RX
Div. V
OCB kit OCB kit
OCB kit RFU RFU
RFU
Coupler

TX TX
TX Antenna Antenna

Existing Pole Mount

Existing Pole Mount


Div. V Div. V
Term.

Term.
RX
DCB

RX

DCB
Reused RFU/ BN
Term.

RX

No Change
Term. Term.
RX RX
Existing Pole Mount

Coupler

Coupler
RX

OCB kit OCB kit


RFU RFU
x WG xW
G
RFU
OCB kit TX Fle TX Fle
Antenna
TX RX
Main H RX
Added Acc.:
Coupler

2x S-Bend WG
S-Bend WG

S-Bend WG
Term.

RX RX RX
Flex WG

Flex WG
2x DCB
Added RFU/ BN

Antenna 1x Flex WG
RX
Div. H OCB kit (Non use: 2x Couplers) OCB kit
RFU RFU
OCB kit TX TX
RFU
Coupler

Term.

TX

Term.
RX
DCB

RX

DCB
Term.

Term.
RX RX RX
Term.

RX
OCB kit
OCB kit RFU
RFU Antenna
Antenna TX
Main H
TX
Main H
(requires whenever RFU>5)
Coupler

RX
Additional Pole Mount

Reused RFU/ BN
Term.

RX

Coupler
S-Bend WG
Added RFU/ BN

Antenna RX
RX
Div. H
OCB kit
OCB kit RFU
RFU
Coupler

TX
TX Antenna

Existing Pole Mount


Div. H
Term.

RX

DCB
Term.

RX
Term.
RX

Coupler
RX

OCB kit
RFU
x WG
TX Fle

RX
Added Acc.:
Added RFU/ BN

2x S-Bend WG
S-Bend WG

RX
Flex WG

2x DCB
1x Flex WG
OCB kit (Non use: 2x Couplers)
RFU
TX
Term.

RX
DCB

Term.
RX

You might also like