The ePureHD (Extended Pure Harmonic Detection) technology assists in generation of clearer and
ePureHD
more sensitive Harmonic EchoTM images, making examination and diagnosis faster and easier.
Extended Pure
Examination workflow is simplified by incorporating user-friendly functions including a customizable Harmonic
Detection
operation panel, report function for various examinations and integrated digital data management.
Together, these functions significantly reduce the time and labor required for patient examinations.
D-THE
The ProSound α5 SV is equally beneficial for patients, examiners, doctors and facilities in terms of Definitive Tissue Harmonic Echo
2 3
Preeminent Imaging Performance Technological Details
Contributing to confident diagnosis The system incorporates various imaging performance features for capturing of
more useful information for diagnosis.
HDDF ePureHD TM
elements. In the α5 SV system, this delay time is controlled Minimum step of delay The focus down to the pixel level provides uniform beam characteristics in the entire field.
at an accuracy of about 3 nanoseconds, to improve focus
accuracy and suppress quantized side lobes. The large Quantization
4 5
Abdomen Heart and Vessels
Obtaining good images is not enough. The images must
indicate any abnormalities clearly. The α5 SV eliminates the
signals that are not relevant to imaging to the greatest extent
possible to display images accurately.
Real-Time FAM
Free Angular M-Mode
Hepatic cysts HCC
Arbitrary positioning of the M-mode cursor
Up to three M-mode cursors can be positioned at any place and angle on a B-mode image. Meanwhile, the
Cine Memory allows reconstruction of M-mode images and repositioning of the cursors any number of
C.H.E. times after freezing, for smoother and more accurate M-mode examination.
Contrast Harmonic Echo
In the case of low sound pressure type contrast agent, such
as SonoVue, phase shift of the echoes occurs by resonance
TDI
without collapsing the micro-bubbles. The ePureHD function
Tissue Doppler Imaging
can indicate the contrast agent clearly by synthesizing this
Easier detection of abnormal wall movements
phase shift component and the harmonic components.
Tissue Doppler Imaging, which visualizes the velocity of systolic/diastolic movements of the
myocardium as a color image, clearly shows the form, velocity, direction and other information at the
same time. TDI performs best when observing abnormal wall movements and evaluating asynchrony
as well as systolic/diastolic assessment with PW Doppler.
6 7
A Wide Variety of Optional Probes
Examine carefully, properly treat.
DDD (Dual Dynamic Display) Image of 180 degrees transvaginal probe Uterus
Simultaneous real-time display of Flow and grayscale images
* Courtesy of Dr. Y. Nakamura, Juntendou University, School of Medicine, Juntendou Hospital, Japan
8 9
High Performance Means Ease of Use Compatible with the IT Environment
Intuitive and simple operation Enhanced Report Functions and Digital Data Management