Settling Rate Monitor


The STORM™ is a stand‐alone flocculant and coagulant dosing control system for use in Thickener applica ons. The 
device measures the interface se ling  me of Thickener feed samples withdrawn from the Thickener centrewell. 
Turbidity  monitoring  is  used  to  determine  the  se lement  rate.  The  Se ling  rate  is  used  to  control  flocculant 
addi on. The final supernatant turbidity can be used to control coagulant addi on. 

The STORM™ controls the automa c dosing of both flocculant and coagulant reagents to a Thickener. A sample is 
drawn from the Thickener centrewell into the Se ling Cylinder.  When the Se ling Cylinder is full, the flocculated 
par cles will start to se le, passing a specially posi oned op cal sensor.   
 

Flocculant  pump  dose  rate  is  controlled  by  the  rate  at  which  the  sample  se les.  Should  the  sample  se le  too  
quickly, the flocculant dose rate is reduced. If the sample se les too slowly, the flocculant dose rate is increased. 
 

When  all  the  par cles  have  se led,  the  supernatant  turbidity  is  measured.    This  reading  controls  the  coagulant 
dose pump rate. If  the residual turbidity is too high, then the coagulant  pump speed is increased. If the residual 
turbidity is low, then the coagulant pump speed is decreased. 
FEATURES 
 Rockwell Compact Logix PLC   Designed and made in Australia. 
 Colour Touchscreen HMI   Stand‐alone system for the  
 Acrylic Se ling Cylinder  control of flocculant and  
coagulant dosing to Thickener. 
 Turbidity Sensor and Controller 
 Quick‐fit probe installa on. 
 Burkert & Festo pneuma c components 
 Quick‐fit se ling tube design. 
 Integral systems cleaning unit 
 Angled turbidity probe to  
 Remote monitoring op on  eliminate spillage during  
maintenance. 
 Bright LED back ligh ng for 
se ling inspec on. 
 Simple to install and operate. 
 Parts and service readily  
available. 
 Op mises chemical  
consump on. 
 Increases Thickener throughput 
via improved Thickener stability 
(i.e. reduc on in bed level and 
bed density varia ons). 
 Can be integrated into a Nalco 
360 con nuous monitoring  

 
Nalco will supply the following 
Construc on:   Powder coated stainless steel 316 control cabinet  relevant drawings and data, to 
Electrical:    110‐500 Vac, 50/60 Hz, or 24VDC  Nalco’s standard best prac ces;  
      6 amps maximum   Process & Instrumenta on 
      IP66 control cabinet  Drawings (PID’s), Layout and 
      AS/ANZ 3000:2018  hold‐down drawings 
Water Supply:   20 L/min @ 300 KPa   Electrical drawings, Power & 
      1 L/min (consumed)  Control Cable list for site  
Air Supply:    10 L/min @ 600 kPa  installa on,  I/O lists 

Dimensions:    900 x 600 x 380 (mm) (W x H x D)  Manuals: 


 Supply of one (1) hardcopy 
Weight:    Approx. 80 kg   
and one (1) electronic (pdf) 
Connec ons:   Water  ‐ 10mm push fit  copy of the “Installa on,  
  Air  ‐ 10mm bulk head  Opera on and Maintenance 
  Sample   ‐ 25mm Cam‐Lock  Manual” 
 
Sample Line:   Unit supplied with 6 meters of 25mm sample hose  
FEATURES 
 24/7 Remote Monitoring 
 All STORM data is available to 
 Key Parameter Alarm Func ons  be monitored on enVision. 
 Automated Customized Repor ng    Advanced calcula ons for real‐
 Downloadable Data   me grams per tonne (gpt) 
monitoring. 
 Fully Integrated with STORM and Addi onal Sensors 
 Addi onal sensor are available 
 Remote Troubleshoo ng  
for monitoring other process 
 Satellite Connec on Possible for Remote Loca ons  variables (i.e. pH, overflow tur‐
bidity, bed‐level, underflow 
density/flow etc…) 
 
 Firewall protec on 
 Customer access available 
 