easy to install.
shear, cut does not affect other parts. 5 meters in length can
Technical parameters
Max.Power FPC
Mode LED Q'ty/M Color CCT/Chromaticity Lumen/led(lm) CRI(Ra) Voltage (V DC) Current (A/m)
Consumption(W/m Width/thickness
Green 515-525nm --
Yellow 585-600nm --
Dimension(mm/inch)
12V
24V
+
DC24V
Linking operation
Notes: In order to better achieve product luminous effect, each 5 meters long lamp with power
supply cable (regional), suggest that are connected to the power line
installation
Spectrum 1.0=29.835mW/nm
CIE1931 EVERFINE
1.2 x = 0.4415 y = 0.4108
CCT = 2978K
1.0
0.8
0.6
0.4
0.2
0.0
380 480 580 680 780
Wavelength(nm)
Color Parameters:
Chromaticity Coordinate:x=0.4415 y=0.4108/u'=0.2507 v'=0.5247
CCT=2978K(Duv=0.0020) Dominant WL:Ld =582.2nm Purity=55.8%
Ratio:R=21.5% G=77.1% B=1.4% Peak WL:Lp=598.4nm FWHM=126.8nm
Render Index:Ra=72.1
R1 =69 R2 =80 R3 =89 R4 =70 R5 =67 R6 =71 R7 =81
R8 =50 R9 =-21 R10=53 R11=63 R12=43 R13=71 R14=93 R15=63
Photo Parameters:
Flux = 1491 lm Eff. : 97.38 lm/W Fe = 4.326 W
Electrical parameters:
V = 11.999 V I = 1.276 A P = 15.31 W PF = 1.000
LEVEL:OUT WHITE:ANSI_3000K
Spectrum 1.0=64.975mW/nm
CIE1931 EVERFINE
1.2 x = 0.3181 y = 0.3293
CCT = 6214K
1.0
0.8
0.6
0.4
0.2
0.0
380 480 580 680 780
Wavelength(nm)
Color Parameters:
Chromaticity Coordinate:x=0.3181 y=0.3293/u'=0.2015 v'=0.4693
CCT=6214K(Duv=0.0007) Dominant WL:Ld =488.3nm Purity=5.4%
Ratio:R=12.9% G=82.9% B=4.2% Peak WL:Lp=452.4nm FWHM=27.7nm
Render Index:Ra=74.7
R1 =73 R2 =78 R3 =79 R4 =75 R5 =74 R6 =69 R7 =84
R8 =65 R9 =-12 R10=46 R11=71 R12=45 R13=74 R14=88 R15=71
Photo Parameters:
Flux = 2190 lm Eff. : 89.34 lm/W Fe = 7.006 W
Electrical parameters:
V = 23.344 V I = 1.050 A P = 24.51 W PF = 1.000
LEVEL:OUT WHITE:ANSI_6500K
Safety Information
- The strip itself and all its components may not be mechanically
stressed.
- Assembly must not damage or destroy conducting paths on the
circuit board.
- Installation of LED ribbon (with power supplies) needs to be made
with regard to all applicable electrical and safety standards. Only
qualified personnel should be allowed to perform installations.
- Correct electrical polarity needs to be observed. Wrong polarity
may destroy the strip.
- Parallel connection is highly recommended as safe electrical
operation mode.
- Serial connection is not recommended. Unbalanced voltage
drop can cause hazardous overload and damage the strip.
- Please ensure that the power supply is of adapters power to
operate the total load.
- When mounting on metallic or otherwise conductive surfaces,
there needs to be an electrical isolation points between strip
and the mounting surface.
- Pay attention to standard ESD precautions when installing the strip.
- Damaged by corrosion will not be honored as a materials defect claim.
It is the user’s responsibility to provide suitable protection against
corrosive agents such as moisture and condensation and other
harmful elements.