= TAS ================================================================

= LHS ================================================================
= ROS ================================================================
= File and buffer handlig with the recording functions ===============
= RTS ================================================================
= RCS ================================================================
= MSC ================================================================
= STS ================================================================
= IOG HANDLING =======================================================
= Function Change ====================================================
= RP =================================================================
= APZ diverse ========================================================
= LOAD EXCHANGE DATA =================================================
= PROCESSOR LOAD =====================================================
= Size alteration ====================================================
= SRS ================================================================
= GS =================================================================
= Restart ============================================================
= FORLOPP ============================================================
= FILES and IO =======================================================
= PRINTOUT ROUTING ===================================================
= BTS stuff ==========================================================

======================================================================
= TAS ================================================================
======================================================================

Taking MOs in to OPER


---------------------

MO Definition/Printing
----------------------
RXMOC:MO=RXETG-0,SWVER=BTSG01R05; !SWVER UPSIM!
RXMOC:MO=RXOTG-100,SWVER=BTSG12R03; !SWVER UPSIM!

RXMDP:MO=RXETS-0-0-0&&-7; ! MANAGED OBJECT DEVICE INFO !


RXCDP:MO=RXETS-0-0-0&&-7; ! MANAGED OBJECT CONFIGURATION DATA !

Abis Paths
----------
RXAPP:MO=RXOTG-101;
RXAPE:MO=RXOTG-101,DCP=1&&6;
If Loading fails
----------------
RXMOC:MO=RXOCF-100,SWVER=DEFAULT; !SWVER Default!
RXMOC:MO=RXOTRX-100-0,SWVER=DEFAULT; !SWVER Default!
RXMOC:MO=RXOTRX-100-1,SWVER=DEFAULT; !SWVER Default!

Error Log
---------
RXELP:MO=RXETG-0;
RXELR:MO=RXETG-0;

RXMFP:MO=RXETG-0;
RXMFP:MO=RXETRX-0;

Maintenance Log
---------------
RXMLP:MO=RXETG-0,FORMAT=ISO,HOURS=2,EDATE=971006,ETIME=165300;
RXMLP:MO=RXETG-0,FORMAT=ISO,HOURS=2;
RXMLI; !Initiate the Logging!
RXMLE; !End the Logging!
RXMLR; !Reset the Log!

RXDLC,FUNCID=ALL,DETLEV=2; !Detail Level Change!


!DETLEV 0-4, 0=Nothing logged!
!1=FA, 2=SE, 3=FE, 4=DE!
RXDLP:FUNCID=ALL; !Detail Level Print!

RXMPI; !Print the Log ongoing!

RXMPE; !End printing the Log!

BTS Capabilities
----------------
RXCAP:MO=RXETG-0;

Alarm printouts
---------------
RXALC:MO=RXETG-O;
RXALP:MO=RXETG-O;

Loop test
---------
RXLTI:MO=RXOTS-100-0-1;

Test of managed object command result


-------------------------------------
RXTEI:MO=RXETRX-0-0;

Loading
-------
RXPLI:MO=RXETRX-1-0;
RXPLE:MO=RXETRX-1-0;

Various Commands
----------------
RXHEI;

ALL TAS PRINTOUTS IN CME R7


-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
G12
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------

<RXALP:MO=RXOTG-0; ! ALARM CORDINATION DATA !

RADIO X-CEIVER ADMINISTRATION


ALARM COORDINATION DATA

MO TGCOORD ALCOTIM ALMASK


RXOTG-0 OFF 90

END

-------------------------------------------------------------------------------
<RXAPP:MO=RXOTG-0; ! ABIS PATH STATUS !

RADIO X-CEIVER ADMINISTRATION


ABIS PATH STATUS

MO
RXOTG-0

DEV DCP APUSAGE APSTATE TEI


RBLT-129 1 UNCONC CF AND TRXC SIGNALLING 62 1
RBLT-130 2 MPLEX16 SPEECH/DATA
MPLEX16 SPEECH/DATA
MPLEX32 IDLE
RBLT-131 3 MPLEX16 SPEECH/DATA
MPLEX16 SPEECH/DATA
MPLEX16 SPEECH/DATA
MPLEX16 SPEECH/DATA
RBLT-132 4 MPLEX16 SPEECH/DATA
MPLEX16 SPEECH/DATA
MPLEX16 SPEECH/DATA
MPLEX16 SPEECH/DATA
RBLT-133 5 MPLEX16 SPEECH/DATA
MPLEX16 SPEECH/DATA
MPLEX16 SPEECH/DATA
MPLEX16 SPEECH/DATA
RBLT-134 6 UNCONC TRXC SIGNALLING 0

END

-------------------------------------------------------------------------------

<RXASP:MO=RXOTG-0; ! MANAGED OBJECT ALARM SITUATIONS !

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT ALARM SITUATIONS

MO EMG RSITE ALARM SITUATION


RXOTG-0 ULM261
END

-------------------------------------------------------------------------------

<RXCAP:MO=RXOTG-0,SUBORD; ! MANAGED OBJECT CAPABILITES !

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT CAPABILITY INFORMATION

MO CASCADABLE OMLF1 OMLF2 RSLF1 RSLF2


RXOTG-0 NO 0 FF FF 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0

MO EXTAL TRU
RXOCF-0 0 0 1

MO
RXOIS-0 NO PARAMETERS

MO TEI DCP1 DCP2 OMLF1 OMLF2 RSLF1 RSLF2


RXOTRX-0-0 0 128 129 0 FF F3 0
130 0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0

AA TCFMODE TCHMODE
OFF 0 1 3 4 0 1 2 3
5 6 7 8
10 11

MO TEI DCP1 DCP2 OMLF1 OMLF2 RSLF1 RSLF2


RXOTRX-0-1 1 131 132 0 FF F3 0
133 0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
AA TCFMODE TCHMODE
OFF 0 1 3 4 0 1 2 3
5 6 7 8
10 11

MO TFMODE SYNCSRC
RXOTF-0 SA PCM

MO BAND FHOP PWRMIN PWRMAX PWRINC ARFCNMIN ARFCNMAX


RXOTX-0-0 GSM BB 21 35 2 1 124
SY

RXOTX-0-1 GSM BB 21 35 2 1 124


SY

MO RXD BAND ARFCNMIN ARFCNMAX


RXORX-0-0 AB GSM 1 124

RXORX-0-1 AB GSM 1 124

MO AGBLK OFFSMIN OFFSMAX XRA


RXOTS-0-0-0 0 1 0 1023 OFF
RXOTS-0-0-1 0 1 0 1023 OFF
RXOTS-0-0-2 0 1 0 1023 OFF
RXOTS-0-0-3 0 1 0 1023 OFF
RXOTS-0-0-4 0 1 0 1023 OFF
RXOTS-0-0-5 0 1 0 1023 OFF
RXOTS-0-0-6 0 1 0 1023 OFF
RXOTS-0-0-7 0 1 0 1023 OFF
RXOTS-0-1-0 0 1 0 1023 OFF
RXOTS-0-1-1 0 1 0 1023 OFF
RXOTS-0-1-2 0 1 0 1023 OFF
RXOTS-0-1-3 0 1 0 1023 OFF
RXOTS-0-1-4 0 1 0 1023 OFF
RXOTS-0-1-5 0 1 0 1023 OFF
RXOTS-0-1-6 0 1 0 1023 OFF
RXOTS-0-1-7 0 1 0 1023 OFF

END

-------------------------------------------------------------------------------
<RXCDP:MO=RXOTG-0; ! MANAGED OBJECT CONFIGURATION DATA !

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT CONFIGURATION DATA

MO RESULT ARFCN MISMATCH


RXORX-0-0 CONFIG HOP NONE
RXORX-0-1 CONFIG HOP NONE

MO RESULT ARFCN TXAD TN BPC CHCOMB OFFS XRA ICM


RXOTS-0-0-0 CONFIG 69 0 2 7410 TCH 0 NO ON
RXOTS-0-0-1 CONFIG 69 0 3 7411 TCH 0 NO ON
RXOTS-0-0-2 CONFIG 69 0 4 7412 TCH 0 NO ON
RXOTS-0-0-3 CONFIG 69 0 5 7413 TCH 0 NO ON
RXOTS-0-0-4 CONFIG 69 0 6 7414 TCH 0 NO ON
RXOTS-0-0-5 CONFIG 69 0 7 7415 TCH 0 NO ON
RXOTS-0-0-6 CONFIG 86 1 0 7400 TCH 0 NO ON
RXOTS-0-0-7 CONFIG 86 1 1 7401 TCH 0 NO ON
RXOTS-0-1-0 CONFIG 69 0 0 7408 BCCH 0 NO ON
RXOTS-0-1-1 CONFIG 69 0 1 7409 SDCCH8 0 NO ON
RXOTS-0-1-2 CONFIG 86 1 2 7402 TCH 0 NO ON
RXOTS-0-1-3 CONFIG 86 1 3 7403 TCH 0 NO ON
RXOTS-0-1-4 CONFIG 86 1 4 7404 TCH 0 NO ON
RXOTS-0-1-5 CONFIG 86 1 5 7405 TCH 0 NO ON
RXOTS-0-1-6 CONFIG 86 1 6 7406 TCH 0 NO ON
RXOTS-0-1-7 CONFIG 86 1 7 7407 TCH 0 NO ON

MO RESULT ARFCN TXAD BSPWR C0F MISMATCH


RXOTX-0-0 CONFIG 69 0 33 YES NONE
RXOTX-0-1 CONFIG 86 1 33 NO NONE

END

-------------------------------------------------------------------------------

<RXHDP:MO=RXOTS-0-0-0; ! MANAGED OBJECT HOPPING DATA !

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT HOPPING DATA

MO RESULT HSN MAIO ARFCN TXAD


RXOTS-0-0-0 CONFIG 0 0 69 0

END

-------------------------------------------------------------------------------

<RXHMP; ! HOP FREQ SET EXTENS MEAS PROG DATA !

RADIO X-CEIVER ADMINISTRATION


HOPPING FREQUENCY SET EXTENSION MEASURING PROGRAM DATA

NONE

END

-------------------------------------------------------------------------------

<RXMDP:MO=RXOTS-0-0-0; ! MANAGED OBJECT DEVICE INFORMATION !

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT DEVICE INFORMATION

MO DEVS DEVT
RXOTS-0-0-0 RBLT-133

END

-------------------------------------------------------------------------------

<RXMFP:MO=RXOTG-0; ! MANAGED OBJECT FAULT INFORMATION !

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT FAULT INFORMATION

MO BTSSWVER
RXOTG-0
RU RUREVISION RUSERIALNO
0

RUPOSITION RULOGICALID

STATE BLSTATE INTERCNT CONCNT CONERRCNT L3RESULT L3REASON


OPER 00003

END

-------------------------------------------------------------------------------

<RXMOP:MO=RXOTG-0; ! MANAGED OBJECT DATA !

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT DATA

MO RSITE COMB FHOP MODEL


RXOTG-0 ULM261 HYB BB G12

SWVERREPL SWVERACT CONFMD CONFACT TRACO


B9381R048 NODEL 4 POOL

TGFID
H'0007-0000

END

-------------------------------------------------------------------------------

<RXMOP:MO=RXOCF-0;

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT DATA

MO TEI SWVERREPL SWVERACT SIG


RXOCF-0 62 DEFAULT B9381R048 UNCONC

END

-------------------------------------------------------------------------------

<RXMOP:MO=RXOIS-0;

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT DATA

MO
RXOIS-0 NO PARAMETERS

END

-------------------------------------------------------------------------------

<RXMOP:MO=RXOTF-0;

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT DATA

MO TFMODE SYNCSRC
RXOTF-0 SA DEFAULT

END

-------------------------------------------------------------------------------

<RXMOP:MO=RXOCON-0;

NOT ACCEPTED
UNREASONABLE VALUE
(0)MO=RXOCON-0

-------------------------------------------------------------------------------

<RXMOP:MO=RXODP-0;

NOT ACCEPTED
UNREASONABLE VALUE
(0)MO=RXODP-0

-------------------------------------------------------------------------------

<RXMOP:MO=RXOTRX-0-0;

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT DATA

MO CELL CHGR TEI SIG DCP1


RXOTRX-0-0 ULM261A ALL 0 UNCONC 128

SWVERREPL SWVERACT DCP2


DEFAULT B9381R048 129
130

END

-------------------------------------------------------------------------------

<RXMOP:MO=RXOTX-0-0;

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT DATA

MO CELL CHGR BAND ANT MPWR


RXOTX-0-0 ULM261A ALL GSM 33
END

-------------------------------------------------------------------------------

<RXMOP:MO=RXORX-0-0;

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT DATA

MO RXD BAND ANTA ANTB


RXORX-0-0 AB GSM

END

-------------------------------------------------------------------------------

<RXMOP:MO=RXOTS-0-0-0; ! MANAGED OBJECT DATA !

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT DATA

MO
RXOTS-0-0-0 NO PARAMETERS

END

-------------------------------------------------------------------------------

<RXMSP:MO=RXOTG-0; ! MANAGED OBJECT STATUS !

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT STATUS

MO STATE BLSTATE BLO BLA LMO BTS CONF


RXOTG-0 OPER 0000 0000 STA

END

-------------------------------------------------------------------------------

<RXTCP:MO=RXOTG-0; ! TG TO CHANNEL GROUP !

RADIO X-CEIVER ADMINISTRATION


TG TO CHANNEL GROUP CONNECTION DATA

MO CELL CHGR
RXOTG-0 ULM261A 0

END

-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
G01
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------

<RXALP:MO=RXETG-0; ! ALARM CORDINATION DATA !

RADIO X-CEIVER ADMINISTRATION


ALARM COORDINATION DATA

MO TGCOORD ALCOTIM ALMASK


RXETG-0 OFF 90

END

-------------------------------------------------------------------------------

<RXASP:MO=RXETG-0; ! MANAGED OBJECT ALARM SITUATIONS !


RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT ALARM SITUATIONS

MO EMG RSITE ALARM SITUATION


RXETG-0 ULM201 ULM201

END

-------------------------------------------------------------------------------

<RXCAP:MO=RXETG-0,SUBORD; ! MANAGED OBJECT CAPABILITES !

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT CAPABILITY INFORMATION

MO
RXETG-0 NO PARAMETERS

MO OMLF1 OMLF2 RSLF1 RSLF2


RXETRX-0-0 0 1 FF 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0

AA TCFMODE TCHMODE
0 1 3 4
5 6 7 8
9 10 11

MO OMLF1 OMLF2 RSLF1 RSLF2


RXETRX-0-1

AA TCFMODE TCHMODE

MO TFMODE
RXETF-0 SA

MO BAND FHOP PWRMIN PWRMAX PWRINC ARFCNMIN ARFCNMAX


RXETX-0-0 GSM BB 31 47 2 1 124
RXETX-0-1

MO BAND ARFCNMIN ARFCNMAX


RXERX-0-0 GSM 1 124

RXERX-0-1

MO AGBLK OFFSMIN OFFSMAX XRA


RXETS-0-0-0 0 1 0 1023 ALL
RXETS-0-0-1 0 1 0 1023 ALL
RXETS-0-0-2 0 1 0 1023 ALL
RXETS-0-0-3 0 1 0 1023 ALL
RXETS-0-0-4 0 1 0 1023 ALL
RXETS-0-0-5 0 1 0 1023 ALL
RXETS-0-0-6 0 1 0 1023 ALL
RXETS-0-0-7 0 1 0 1023 ALL
RXETS-0-1-0
RXETS-0-1-1
RXETS-0-1-2
RXETS-0-1-3
RXETS-0-1-4
RXETS-0-1-5
RXETS-0-1-6
RXETS-0-1-7

END

-------------------------------------------------------------------------------

<RXCDP:MO=RXETG-0; ! MANAGED OBJECT CONFIGURATION DATA !

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT CONFIGURATION DATA

MO RESULT ARFCN MISMATCH


RXERX-0-0 CONFIG HOP NONE
RXERX-0-1 BLOCKED NONE

MO RESULT ARFCN TXAD TN BPC CHCOMB OFFS XRA ICM


RXETS-0-0-0 CONFIG 67 0 0 7464 BCCH 0 NO ON
RXETS-0-0-1 CONFIG 67 0 1 7465 SDCCH8 0 NO ON
RXETS-0-0-2 CONFIG 67 0 2 7466 TCH 0 NO ON
RXETS-0-0-3 CONFIG 67 0 3 7467 TCH 0 NO ON
RXETS-0-0-4 CONFIG 67 0 4 7468 TCH 0 NO ON
RXETS-0-0-5 CONFIG 67 0 5 7469 TCH 0 NO ON
RXETS-0-0-6 CONFIG 67 0 6 7470 TCH 0 NO ON
RXETS-0-0-7 CONFIG 67 0 7 7471 TCH 0 NO ON
RXETS-0-1-0 BLOCKED
RXETS-0-1-1 BLOCKED
RXETS-0-1-2 BLOCKED
RXETS-0-1-3 BLOCKED
RXETS-0-1-4 BLOCKED
RXETS-0-1-5 BLOCKED
RXETS-0-1-6 BLOCKED
RXETS-0-1-7 BLOCKED

MO RESULT ARFCN TXAD BSPWR C0F MISMATCH


RXETX-0-0 CONFIG 67 0 37 YES NONE
RXETX-0-1 BLOCKED NONE

INSUFFICIENT TX EQUIPMENT

END

-------------------------------------------------------------------------------

<RXHDP:MO=RXETS-0-0-0; ! MANAGED OBJECT HOPPING DATA !

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT HOPPING DATA

MO RESULT HSN MAIO ARFCN TXAD


RXETS-0-0-0 CONFIG 0 0 67 0

END

-------------------------------------------------------------------------------

<RXHMP; ! HOP FREQ SET EXTENS MEAS PROG DATA !


RADIO X-CEIVER ADMINISTRATION
HOPPING FREQUENCY SET EXTENSION MEASURING PROGRAM DATA

NONE

END

-------------------------------------------------------------------------------

<RXMDP:MO=RXETS-0-0-0; ! MANAGED OBJECT DEVICE INFORMATION !

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT DEVICE INFORMATION

MO DEVS DEVT
RXETS-0-0-0

END

-------------------------------------------------------------------------------

<RXMFP:MO=RXETG-0; ! MANAGED OBJECT FAULT INFORMATION !

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT FAULT INFORMATION

MO BTSSWVER BTSHWREV
RXETG-0

STATE BLSTATE INTERCNT CONCNT CONERRCNT L3RESULT L3REASON


OPER 00000

END

-------------------------------------------------------------------------------
<RXMOP:MO=RXETG-0; ! MANAGED OBJECT DATA !

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT DATA

MO RSITE EMG COMB FHOP MODEL


RXETG-0 ULM201 ULM201 FLT BB G01

SWVERREPL SWVERACT CONFMD CONFACT TRACO


B10041R24 NODEL 4 POOL

TGFID
H'0006-0000

END

-------------------------------------------------------------------------------

<RXMOP:MO=RXETRX-0-0;

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT DATA

MO CELL CHGR TEI CTEI DEV1


RXETRX-0-0 ULM201A ALL 0 58 RBLT-225

SWVERREPL SWVERACT DEV2


B0041R0203 RBLT-226
RBLT-227

END

-------------------------------------------------------------------------------

<RXMOP:MO=RXETF-0;

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT DATA

MO TFMODE
RXETF-0 SA

END

-------------------------------------------------------------------------------

<RXMOP:MO=RXETX-0-0;

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT DATA

MO CELL CHGR BAND ANT MPWR


RXETX-0-0 ULM201A ALL GSM 47

END

-------------------------------------------------------------------------------

<RXMOP:MO=RXERX-0-0;

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT DATA

MO RXD BAND ANTA ANTB


RXERX-0-0 AB GSM

END

-------------------------------------------------------------------------------

<RXMOP:MO=RXETS-0-0-0;
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT DATA

MO
RXETS-0-0-0 NO PARAMETERS

END

-------------------------------------------------------------------------------

<RXMSP:MO=RXETG-0; ! MANAGED OBJECT STATUS !

RADIO X-CEIVER ADMINISTRATION


MANAGED OBJECT STATUS

MO STATE BLSTATE BLO BLA LMO BTS CONF TGC


RXETG-0 OPER 0000 0000 STA

END

-------------------------------------------------------------------------------

<RXTCP:MO=RXETG-0; ! TG TO CHANNEL GROUP !

RADIO X-CEIVER ADMINISTRATION


TG TO CHANNEL GROUP CONNECTION DATA

MO CELL CHGR
RXETG-0 ULM201A 0

END

======================================================================
= LHS ================================================================
======================================================================
RISPI:TSLOT1=RILT-0-1,TSLOT2=RILT-7-0,NAME=RXETG00,PRI=1,REL;
RISPP:EMG=ALL;
RISPP:EMG=0,EMRS=ALL;

======================================================================
= ROS ================================================================
======================================================================

BAR
---
RABII;
RABDC:RID=BARID00,CELL=C1A&C1B,TMBCCHNO=1&&15;

RIR
---
RARII;
RARDC:RID=RIRID00,CELL=C1A&C1B,TMBCCHNO=1&&15;

MRR
---
RAMII;
RAMDC:RID=MRRID00,CELL=C1A&C1B,TMBCCHNO=1&&15;

BTS CONFIGURATION DATA


----------------------
RABCP:OTY=TG;
RABCI:MO=RXETG-0;
RABCI:OTY=TG;
RABCI:CELL=C1A;
RABCI:OTY=CELL;

RABCE;

Cell Traffic recording


----------------------
INMCT:SPG=0;
INFII:FILE=CTRFILE,VOL=EXCHVOLUME,RLENGTH=512,TYPE=SEQ,SIZE=30,EXP=10,FCLASS=CMP
;
END;
INFDI:FILE=CTRFILE,DEST=IOS; ! Define the CTRFILE in the filesystem !
IOIFI:FILE=CTRFILE,NSUB=10; ! Insert a CTRFILE in the filesystem !

RATRI:CELL=C14A,EVENT=CA,DTIME=1,RTYPE=EV&ME,TIMEW=30;
RATRP;
RATRE;

INFDR:FILE=CTRFILE,DEST=IOS; ! INFINITE SEQUENTIAL ACTIVE FILE END !


IOIFR:FILE=CTRFILE; ! INFINITE SEQUENTIAL FILE REMOVAL !
INMCT:SPG=0;
INFIR:FILE=CTRFILE;
END;

IOFAT:FILE=CTRFILE-0001,HEX;

-------------------------------------------------------------------------------
ALL ROS (RA) PRINTOUTS IN CME R7
-------------------------------------------------------------------------------

<RABCP:OTY=ALL; ! BCDC CHANGE LIST !

BTS CONFIGURATION DATA CHANGE LIST

DATE TIME
000102 152953

CELL DEF
ULM261A DEF
ULM201A DEF
ULM211A DEF
ULM211B DEF
ULM211C DEF

EMG DEF
ULM211 DEF
ULM201 DEF

TG DEF DYN HW
RXOTG-0 DEF DYN HW
RXETG-2 DEF DYN HW
RXETG-0 DEF DYN HW

LATEST MAJOR CHANGE


000102 152700

LATEST SYSTEM CLOCK RESET


000102 152700

END

-------------------------------------------------------------------------------

<RABDP:RID=ALL; ! BAR DEFINITION !

ACTIVE BA-LIST RECORDING DEFINITION DATA

RID NCELLTYPE RELSSP RELSSN ABSS NUMFREQ SEGTIME


NONE

END

-------------------------------------------------------------------------------

<RABRP:RID=ALL; ! BAR STATUS !

ACTIVE BA-LIST RECORDING DETAILS

RID RECSTATE DTIME RTIME MRNIC


BARID00 IDLE
BARID01 IDLE
BARID02 IDLE
BARID03 IDLE
BARID04 IDLE
BARID05 IDLE
BARID06 IDLE
BARID07 IDLE
BARID08 IDLE
BARID09 IDLE
BARID10 IDLE
BARID11 IDLE
BARID12 IDLE
BARID13 IDLE
BARID14 IDLE
BARID15 IDLE
BARID16 IDLE
BARID17 IDLE
BARID18 IDLE
BARID19 IDLE
BARID20 IDLE
BARID21 IDLE
BARID22 IDLE
BARID23 IDLE
BARID24 IDLE
BARID25 IDLE
BARID26 IDLE
BARID27 IDLE
BARID28 IDLE
BARID29 IDLE
BARID30 IDLE
BARID31 IDLE
BARID32 IDLE
BARID33 IDLE
BARID34 IDLE
BARID35 IDLE
BARID36 IDLE
BARID37 IDLE
BARID38 IDLE
BARID39 IDLE
BARID40 IDLE
BARID41 IDLE
BARID42 IDLE
BARID43 IDLE
BARID44 IDLE
BARID45 IDLE
BARID46 IDLE
BARID47 IDLE
BARID48 IDLE
BARID49 IDLE
BARID50 IDLE
BARID51 IDLE
BARID52 IDLE
BARID53 IDLE
BARID54 IDLE
BARID55 IDLE
BARID56 IDLE
BARID57 IDLE
BARID58 IDLE
BARID59 IDLE
BARID60 IDLE
BARID61 IDLE
BARID62 IDLE
BARID63 IDLE

END

-------------------------------------------------------------------------------

<RACIP:CIC=1&&100; ! CIRCUIT IDENTITY CODE !

DEVICE AND CIRCUIT IDENTITY CODE DATA

DEV BSC CIC ATERCIC


RALT-1 OWN 1
RALT-2 OWN 2
RALT-3 OWN 3
RALT-4 OWN 4
RALT-5 OWN 5
RALT-6 OWN 6
RALT-7 OWN 7
RALT-8 OWN 8
RALT-9 OWN 9
RALT-10 OWN 10
RALT-11 OWN 11
RALT-12 OWN 12
RALT-13 OWN 13
RALT-14 OWN 14
RALT-15 OWN 15
RALT-16 OWN 16
RALT-17 OWN 17
RALT-18 BSC6C 18
RALT-19 BSC6C 19
RALT-20 BSC6C 20
RALT-21 BSC6C 21
RALT-22 BSC6C 22
RALT-23 BSC6C 23
RALT-24 BSC6C 24
RALT-25 BSC6C 25
RALT-26 BSC6C 26
RALT-27 BSC6C 27
RALT-28 BSC6C 28
RALT-29 BSC6C 29
RALT-30 BSC6C 30
RALT-31 BSC6C 31
FAULT INTERRUPT
FAULT CODE 67
CIC NOT DEFINED
(0)CIC=32
END

-------------------------------------------------------------------------------

<RACIP:DEV=RALT-1;

DEVICE AND CIRCUIT IDENTITY CODE DATA

DEV BSC CIC ATERCIC


RALT-1 OWN 1
END

-------------------------------------------------------------------------------

<RADCP; ! MSC DEST POINT CODE ANSI !

NOT ACCEPTED
FAULT CODE 54
DESTINATION POINT CODE NOT IN ACCORDANCE WITH SIGNALLING TYPE

-------------------------------------------------------------------------------

<RADEP:DEV=RALT-1; ! DEVICE DATA !

DEVICE DATA IN BSC


DEV SNT/DEVP MUP
RALT-1 ETRALT-0 GS-0-1

DEV MISC1 MISC2 MISC3 MISC4 ADMSTATE


EM SNT S CIC
RALT-1 1 C C C C
END

-------------------------------------------------------------------------------

<RADPP; ! MSC DEST POINT CODE CCITT !

CCITT DESTINATION POINT CODE DATA

DPC NEI
5136 2
END

-------------------------------------------------------------------------------

<RADRP:DEV=RALT-1; ! DEVICE RP/EM DATA !

DEVICE RP/EM DATA IN BSC

DEV RP EMG EM ADMSTATE


EM SNT S CIC
RALT-1 64 0 C C C C
END

-------------------------------------------------------------------------------

<RAEPP:ID=ALL; ! EXCHANGE PROPERTY !

BSC EXCHANGE PROPERTY DATA

PROP TYPE
LINKCHECKTIME-4 OPTIONAL
HSCSDUPGTIMER-5 OPTIONAL
ATERFCWINMIN-1 OPTIONAL
ATERFCWINMAX-12 OPTIONAL
ATERFCSTEPUPLMT-40 OPTIONAL
NUMTRALOADS-3 OPTIONAL
PHSTATE-0 OPTIONAL
CHALLOC-0 OPTIONAL
TCHCAPAA-0 OPTIONAL
TCHCAP3-65535 OPTIONAL
TCHCAP2-65535 OPTIONAL
TCHCAP1-65535 OPTIONAL
TCHCAPSEL-1 OPTIONAL
SPEECHVERUSED-1 OPTIONAL
DCAHANDOVER-0 OPTIONAL
DEFAULTSYNCSRC-65535 OPTIONAL
SCLDTIMEINT-100 OPTIONAL
CLSTIMEINTERVAL-100 OPTIONAL
CONCLINKCEASE-60 OPTIONAL
CONCLINKALARM-70 OPTIONAL
CONCBOARDCEASE-60 OPTIONAL
CONCBOARDALARM-70 OPTIONAL
MAXLOAD-80 OPTIONAL
BADQUL-55 OPTIONAL
BADQDL-55 OPTIONAL
LOWSSDL-104 OPTIONAL
LOWSSUL-104 OPTIONAL
FASTASSIGN-0 OPTIONAL
TRXTAUTOTHRSHLD-20 OPTIONAL
TRXTAUTOINITIME-10 OPTIONAL
INITTCH-2 OPTIONAL
HALFRATESUPP-0 OPTIONAL
TIMER3105-6 OPTIONAL
NOOFPHYSINFOMSG-35 OPTIONAL
TRACEMSGTYPE-0 OPTIONAL
CLMRKMSG-0 OPTIONAL
MNCDIGITHAND-0 OPTIONAL
REGPOINTPROCLD-80 OPTIONAL
FCMAXNOPTGLG12-0 OPTIONAL
FCMAXNOPTGLG01-0 OPTIONAL

END

-------------------------------------------------------------------------------
<RAHDP; ! TRH LOAD MONITORING & DISTRIBUTION !

RADIO CONTROL ADMINISTRATION


TRH LOAD MONITORING AND DISTRIBUTION DATA

CAPHYST CAPLIM INTERVAL STIME


5 5 24 0200
END

-------------------------------------------------------------------------------

<RAHEP; ! TRH EVENT LOG !

RADIO CONTROL ADMINISTRATION


TRH EVENT LOG

DATE TIME EVENT SNT1 SNT2 DEV1 DEV2


END

-------------------------------------------------------------------------------

<RAHHP:SNT=ALL; ! TRH LOAD TABLE !

RADIO CONTROL ADMINISTRATION


TRH LOAD TABLE

DATE TIME AVECAP


000000 0000 0

SNT CAP HIGHCAP LOWCAP


RHSNT-0 120 120 0
RHSNT-1 120 120 0
RHSNT-2 120 120 0
RHSNT-3 40 40 0
RHSNT-4 40 40 0
RHSNT-5 40 40 0
RHSNT-6 40 40 0
RHSNT-7 40 40 0
END

-------------------------------------------------------------------------------

<RAHLP; ! TRH LOAD THRESHOLD DATA !

RADIO CONTROL ADMINISTRATION


TRH LOAD THRESHOLD DATA

AVELIM NOTRHLIM TRHLIM


0 50 0
END

-------------------------------------------------------------------------------

<RAHTP:SNT=ALL; ! TRH DEVICE LOAD TABLE !

RADIO CONTROL ADMINISTRATION


TRH DEVICE LOAD TABLE

DATE TIME
000000 0000

SNT DEVICE DEVCAP


RHSNT-0 1 0
2 0
3 0
4 0
5 0
6 0
7 0
8 0
9 0
10 0
11 0
12 0
13 0
14 0
15 0
16 0
17 0
18 0
19 0
20 0
21 0
22 0
23 0
24 0
25 0
26 0
27 0
28 0
29 0
30 0
31 0
RHSNT-1 1 0
2 0
3 0
4 0
5 0
6 0
7 0
8 0
9 0
10 0
11 0
12 0
13 0
14 0
15 0
16 0
17 0
18 0
19 0
20 0
21 0
22 0
23 0
24 0
25 0
26 0
27 0
28 0
29 0
30 0
31 0
RHSNT-2 1 0
2 0
3 0
4 0
5 0
6 0
7 0
8 0
9 0
10 0
11 0
12 0
13 0
14 0
15 0
16 0
17 0
18 0
19 0
20 0
21 0
22 0
23 0
24 0
25 0
26 0
27 0
28 0
29 0
30 0
31 0
RHSNT-3 1 0
2 0
3 0
4 0
5 0
6 0
7 0
RHSNT-4 1 0
2 0
3 0
4 0
5 0
6 0
7 0
RHSNT-5 1 0
2 0
3 0
4 0
5 0
6 0
7 0
RHSNT-6 1 0
2 0
3 0
4 0
5 0
6 0
7 0
RHSNT-7 1 0
2 0
3 0
4 0
5 0
6 0
7 0
END

-------------------------------------------------------------------------------

<RAMDP:RID=ALL; ! MRR DEFINITION !

MEASUREMENT RESULT RECORDING DEFINITION DATA

RID MEASTYPE MEASINT MEASLIM


NONE

END
-------------------------------------------------------------------------------

<RAMRP:RID=ALL; ! MRR STATUS !

MEASUREMENT RESULT RECORDING DETAILS

RID RECSTATE TTIME DTIME RTIME


MRRID00 IDLE
MRRID01 IDLE
MRRID02 IDLE
MRRID03 IDLE
MRRID04 IDLE
MRRID05 IDLE
MRRID06 IDLE
MRRID07 IDLE
MRRID08 IDLE
MRRID09 IDLE

END

-------------------------------------------------------------------------------

<RARDP:RID=ALL; ! RIR DEFINITION !

RADIO INTERFERENCE RECORDING DEFINITION DATA

RID
NONE

END

-------------------------------------------------------------------------------

<RARRP:RID=ALL; ! RIR STATUS !


RADIO INTERFERENCE RECORDING DETAILS

RID RIDSTATE TTIME DTIME RTIME


RIRID00 IDLE
RIRID01 IDLE
RIRID02 IDLE
RIRID03 IDLE
RIRID04 IDLE
RIRID05 IDLE
RIRID06 IDLE
RIRID07 IDLE
RIRID08 IDLE
RIRID09 IDLE

END

-------------------------------------------------------------------------------

<RASAP; ! SEIZURE OF DEVICES ALARM !

SEIZURE SUPERVISION OF DEVICES IN BSC ALARMED DEVICES

NEVER USED DEVICES

DEV STATE
NONE

CONTINUOUSLY BUSY DEVICES

DEV STATE
NONE

END

-------------------------------------------------------------------------------
<RASIP; ! SIGNALLING TYPE !

SIGNALLING TYPE DATA

SIGTYPE
CCITT

END

-------------------------------------------------------------------------------

<RASSP:DETY=RALT; ! SEIZURE OF DEVICES DATA !

NOT ACCEPTED
FAULT CODE 5
SUPERVISION DATA NOT LOADED

<RATPP; ! TRANSCEIVER PERIODIC TEST DATA !

TRANSCEIVER PERIODIC TEST DATA

STATE TIME INTERVAL


PASSIVE

END

-------------------------------------------------------------------------------

<RATRP; ! CTR !

CELL TRAFFIC RECORDING DATA

RECORDING NOT STARTED

END
-------------------------------------------------------------------------------

<RATTP:CELL=ALL; ! TRANCEIVER TEST AND SUPERVISION !

TRANSCEIVER TEST AND SUPERVISION DATA

CELL
NONE

END

======================================================================
= File and buffer handlig with the recording functions ===============
======================================================================

INMCT:SPG=0;

INFIP; ! Print all files !


INFIP:FILE=RIRFIL00; ! Print data about RIRFIL00 !
INFIP:FILE=RIRFIL00-0001; ! Print data about subfil 0001 to RIRFIL00 !

INFIR:FILE=RIRFIL00; ! Remove file, see below for needed action !

INFII:FILE=RIRFIL00..... ! See AI2 for values !

END;

How to check the recording result (not BCDC)


--------------------------------------------

IOFAT:FILE=RIRFIL00-0001,HEX; ! Print RIRFIL00, Hex !

!Use Recconv to decode the HEX file !

cmclean rir1 > rir2


recconv rir2 > rir3 ! A readable file !

How to check the recording result (BCDC)


----------------------------------------
Start TFTtool from the Channel Manager - on X25
Settings :
- Remote -> WS
- Remote File : BCDCFILE (subfile if defined)
- Unixfile : newfile
Transfer.

Open newfile and remove the first row, save as newfile2

ber -d < newfile2 > file3

Remove subfiles from BARFIL00


-----------------------------

INFDR:FILE=BARFIL00,DEST=KA1156;
@E
INFDR:FILE=BARFIL00,DEST=IOS;
@E
IOIFR:FILE=BARFIL00;
@E
INMCT:SPG=0;
INFIR:FILE=BARFIL00-0001;
INFIR:FILE=BARFIL00-0002;
END;
@E
INFDI:FILE=BARFIL00,DEST=IOS;
IOIFI:FILE=BARFIL00,NSUB=10;
INFDI:FILE=BARFIL00,DEST=KA1156,POLL;
INFSI:FILE=BARFIL00-0001;
INFSI:FILE=BARFIL00-0002;

Remove subfiles from RIRFIL00


-----------------------------

INFDR:FILE=RIRFIL00,DEST=KA1156;
@E
INFDR:FILE=RIRFIL00,DEST=IOS;
@E
IOIFR:FILE=RIRFIL00;
@E
INMCT:SPG=0;
INFIR:FILE=RIRFIL00-0001;
INFIR:FILE=RIRFIL00-0002;
END;
@E
INFDI:FILE=RIRFIL00,DEST=IOS;
IOIFI:FILE=RIRFIL00,NSUB=10;
INFDI:FILE=RIRFIL00,DEST=KA1156,POLL;
INFSI:FILE=RIRFIL00-0001;
INFSI:FILE=RIRFIL00-0002;

Remove subfiles from CTRFILE


----------------------------

INFDR:FILE=CTRFILE,DEST=KA1156;
@E
INFDR:FILE=CTRFILE,DEST=IOS;
@E
IOIFR:FILE=CTRFILE;
@E
INMCT:SPG=0;
INFIR:FILE=CTRFILE-0001;
INFIR:FILE=CTRFILE-0002;
END;
@E
INFDI:FILE=CTRFILE,DEST=IOS;
IOIFI:FILE=CTRFILE,NSUB=10;
INFDI:FILE=CTRFILE,DEST=KA1156,POLL;
INFSI:FILE=CTRFILE-0001;
INFSI:FILE=CTRFILE-0002;

Clear BCDCFILE
--------------

INMCT:SPG=0; ! Remove file !


INFIR:FILE=BCDCFILE;
END;
@E
INMCT:SPG=0; ! Create file !
INFII:FILE=BCDCFILE,SIZE=2500,RLENGTH=512,EXP=2500,TYPE=SEQ,FCLASS=SPL,VOL=RELVO
LUMSW;
END;
@E

Buffer handling
---------------

LABUP; ! Check the buffers !


SAAII:SAE=345,NI=10; ! Increase buffer size !
SAAII:SAE=355,NI=10; ! SAE 345 - 355 !

======================================================================
= RTS ================================================================
======================================================================

Pool Handling
-------------

RRTPI:TRAPOOL=pool,CHRATE=FR,SPV=1;
RRTPE:TRAPOOL=pool;

RRTPC:TRAPOOL=pool,RNOTRA=8160,FORCE; !Change pool size!

RRTPP:TRAPOOL=ALL; !Print the Pools!


RRTPP:TRAPOOL=ALL,PRINTDEV;

TRA Handling
------------

STDEP:DEV=RTTRD-0&&-31; ! Print the TRAs !


RRTBI:DEV=RTTRD-2&-7&-12&-17&-22&-27,FORCE; ! Block TRA !
RRTBE:DEV=RTTRD-2&-7&-12&-17&-22&-27; ! Deblock TRA !

ALL RTS (RR) PRINTOUTS IN CME R7


-------------------------------------------------------------------------------

<RRBSP; ! DEF OF BSC IN TRC !

BSC DEFINITION DATA

BSC DPC NEI


BSC6C 5139 2
END

-------------------------------------------------------------------------------

<RRDSP:SNT=ALL; ! DEV SOFTWARE UNIT INFO !

RADIO TRANSMISSION DEVICE SOFTWARE UNIT INFORMATION

SNT
RTTRS-0

BOARD RESULT
TRAB-0 TRAB NOT LOADABLE

SNT
RTTRS-1

BOARD RESULT
TRAB-0 TRAB NOT LOADABLE

SNT
RTTRS-2

BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAH 146 003 R1B

SNT
RTTRS-3

BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAH 146 003 R1B

SNT
RTTRS-4
BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAH 146 003 R1B

SNT
RTTRS-5

BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAH 146 003 R1B

SNT
RTTRS-6

BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAH 146 003 R1B

SNT
RTTRS-7

BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAH 146 003 R1B

SNT
RTTRS-8

BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAH 146 003 R1B

SNT
RTTRS-9
BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAH 146 003 R1B

SNT
RTTF1S-0

BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAW 200 005 R1A

SNT
RTTF1S-1

BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAW 200 005 R1A

SNT
RTTF1S-2

BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAW 200 005 R1A

SNT
RTTF1S-3

BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAW 200 005 R1A

SNT
RTTF1S-4

BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAW 200 005 R1A

SNT
RTTF1S-5

BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAW 200 005 R1A

SNT
RTTF2S-0

BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAW 200 003 R1A

BOARD RESULT
TRAB-1 SUCCESSFUL

SUID
CAAW 200 003 R1A

SNT
RTTF2S-1

BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAW 200 003 R1A

BOARD RESULT
TRAB-1 SUCCESSFUL
SUID
CAAW 200 003 R1A

SNT
RTTH2S-0

BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAW 200 007 R1A

BOARD RESULT
TRAB-1 SUCCESSFUL

SUID
CAAW 200 007 R1A

SNT
RTTH2S-1

BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAW 200 007 R1A

BOARD RESULT
TRAB-1 SUCCESSFUL

SUID
CAAW 200 007 R1A

SNT
RTTH2S-2

BOARD RESULT
TRAB-0 SUCCESSFUL

SUID
CAAW 200 007 R1A

BOARD RESULT
TRAB-1 SUCCESSFUL
SUID
CAAW 200 007 R1A
END

-------------------------------------------------------------------------------

<RRISP:TRAPOOL=ALL; ! TRAPOOL IDLE LEVEL SUPERVISION !

RADIO TRANSMISSION TRANSCODER POOL IDLE LEVEL SUPERVISION DATA

TRAPOOL SUPSTATUS ACL LIM1 LIM2


EFR ON A2 2 1
HR ON A2 2 1
FR ON A2 20 10
END

-------------------------------------------------------------------------------

<RRLLP; ! LINE LEVEL !

RADIO TRANSMISSION LINE SPEECH LEVEL DATA

UPLINK LINE LEVEL ADJUSTMENT


+ 0

DOWNLINK LINE LEVEL ADJUSTMENT


+ 0

END

-------------------------------------------------------------------------------

<RRMAP:TRAPOOL=ALL; ! TRAPOOL MEAN HOLD TIME SUP ALARM !

RADIO TRANSMISSION TRANSCODER POOL MEAN HOLD TIME SUPERVISION ALARM DATA
TRAPOOL
EFR

DEV
NONE

TRAPOOL
HR

DEV
NONE

TRAPOOL
FR

DEV
NONE
END

-------------------------------------------------------------------------------

<RRMSP:TRAPOOL=ALL; ! TRAPOOL MEAN HOLD TIME SUP !

RADIO TRANSMISSION TRANSCODER POOL MEAN HOLD TIME SUPERVISION DATA

TRAPOOL SUPSTATUS ACL MHTLIM


EFR ON A3 10
HR ON A3 10
FR ON A3 10
END

-------------------------------------------------------------------------------

<RRNTP; ! NODE TYPE !

NODE TYPE DATA


NODETYPE DPC NEI
BSCTRC 5139 2
END

-------------------------------------------------------------------------------

<RRTPP:TRAPOOL=ALL; ! TRANSCODER POOL !

RADIO TRANSMISSION TRANSCODER POOL DETAILS

TRAPOOL CHRATE SPV RNOTRA ANOTRA TRAIDLE TRATRAF


EFR FR 2 48 48 47 1
HR HR 1 48 48 48 0
FR FR 1 384 384 384 0
END

======================================================================
= RCS ================================================================
======================================================================

Cell activation
---------------
RXTCP:MO=RXETG-1; !Print connection cell - TG!

RLSTC:CELL=C1A,CHGR=0,STATE=ACTIVE;
RLSTP:CELL=C1B;

RLCRP:CELL=C1B;

RXMDP:MO=RXETS-0-0-0&&-7;
RXCDP:MO=RXETS-0-0-0&&-7;

Lower the power when activating cell with micro 2000


----------------------------------------------------
RLCPP:CELL=C1C; ! Print current values !

RLCPC:CELL=design5,BSPWRB=21,BSPWRT=21,MSTXPWR=21; ! Change values !

RLCPC:CELL=C1C,BSPWRB=37,BSPWRT=35,MSTXPWR=39; ! Restore values !

Faulty UPSIM answers with Xrange cells only


-------------------------------------------
RLCFP:CELL=c1a;
RLDEP:CELL=c1a;
RXCDP:MO=RXETG-0;

RLDEC:CELL=C1A,XRANGE=YES;

RLCDP:CELL=c1a;
RLCDC:CELL=c1a,MC=OFF;
RLCCC:TN=2,CELL=C1A;

ALL RCS PRINTOUTS IN CME R7


-------------------------------------------------------------------------------

<RLACP:CELL=C1B;

CELL ADAPTIVE LOGICAL CHANNEL CONFIGURATION

CELL ACSTATE SLEVEL STIME


C1B OFF 0 20
END

-------------------------------------------------------------------------------

<RLBCP:CELL=C1B;

DYNAMIC BTS POWER CONTROL CELL DATA

CELL DBPSTATE
C1B ACTIVE

SCTYPE SDCCHREG SSDESDL REGINTDL SSLENDL LCOMPDL QDESDL


OFF 105 1 4 20 0

QCOMPDL QLENDL BSPWRMINP BSPWRMINN


60 3 20
END

-------------------------------------------------------------------------------
<RLBDP:CELL=C1B;

CELL CONFIGURATION BPC DATA

CELL
C1B

CHGR NUMREQBPC
SYSDEF
END

-------------------------------------------------------------------------------
<RLCAP;

BSC CIPHERING ALGORITHM DATA

ALG
ALG1

END
-------------------------------------------------------------------------------
<RLCDP:CELL=C1B;

CELL MULTIPLE CHANNEL ALLOCATION DATA

BSCMC
ON

CELL MC
C1B ON
END
-------------------------------------------------------------------------------
<RLCFP:CELL=C1B;

CELL CONFIGURATION FREQUENCY DATA

CELL
C1B

CHGR SCTYPE SDCCH SDCCHAC TN CCHPOS CBCH HSN HOP DCHNO


1 0 1 TN NO 1 OFF 7
END

-------------------------------------------------------------------------------
<RLCPP:CELL=C1B;

CELL CONFIGURATION POWER DATA

CELL TYPE BSPWRB BSPWRT MSTXPWR SCTYPE


C1B INT 35 35 39
END

-------------------------------------------------------------------------------
<RLCRP:CELL=C1B;

CELL RESOURCES

CELL BCCH CBCH SDCCH NOOFTCH


C1B 1 0 8 6- 12

BPC CHANNEL CHRATE SPV STATE ICMBAND


5799 TCH-8154 FR 1,2 IDLE 1
TCH-24469 HR 1 IDLE 1
TCH-24468 HR 1 IDLE 1
5800 TCH-8155 FR 1,2 IDLE 1
TCH-24471 HR 1 IDLE 1
TCH-24470 HR 1 IDLE 1
5801 TCH-8156 FR 1,2 IDLE 1
TCH-24473 HR 1 IDLE 1
TCH-24472 HR 1 IDLE 1
5802 TCH-8157 FR 1,2 IDLE 1
TCH-24475 HR 1 IDLE 1
TCH-24474 HR 1 IDLE 1
5803 TCH-8158 FR 1,2 IDLE 1
TCH-24477 HR 1 IDLE 1
TCH-24476 HR 1 IDLE 1
5804 TCH-8159 FR 1,2 IDLE 1
TCH-24479 HR 1 IDLE 1
TCH-24478 HR 1 IDLE 1
5805 SDCCH-34687 IDLE 1
SDCCH-34686 IDLE 1
SDCCH-34685 IDLE 1
SDCCH-34684 IDLE 1
SDCCH-34683 IDLE 1
SDCCH-34682 IDLE 1
SDCCH-34681 IDLE 1
SDCCH-34680 IDLE 1
5806 BCCH-34689 BUSY
END

-------------------------------------------------------------------------------
<RLCXP:CELL=C1B;
CELL CONFIGURATION DTX DOWNLINK DATA

CELL DTXD
C1B OFF
END

-------------------------------------------------------------------------------
<RLDCP;

BSC DIFFERENTIAL CHANNEL ALLOCATION DATA

STATE EMERGPRL
ON 9
END

-------------------------------------------------------------------------------

<RLDEP:CELL=C1B;

CELL DESCRIPTION DATA

CELL CGI BSIC BCCHNO AGBLK MFRMS


C1B 262-02-106-2 11 7 1 4

TYPE BCCHTYPE FNOFFSET XRANGE CSYSTYPE


INT NCOMB 0 NO GSM
END

-------------------------------------------------------------------------------
<RLDGP:CELL=C1G;

CELL CHANNEL GROUP DATA

CELL CHGR SCTYPE


C1G 0 UL
1 UL
2 OL
END

-------------------------------------------------------------------------------
<RLDTP:CELL=C1G;

CELL TRAINING SEQUENCE CODE DATA


CELL TSC SCTYPE
C1G 1 UL
1 OL
END

-------------------------------------------------------------------------------
<RLHPP:CELL=C1B;

CONNECTION OF CELL TO CHANNEL ALLOCATION PROFILE DATA

CELL CHAP
C1B 0
END

-------------------------------------------------------------------------------
<RLIHP:CELL=C1B;

CELL LOCATING INTRACELL HANDOVER DATA

CELL SCTYPE IHO MAXIHO TMAXIHO TIHO SSOFFSETULP SSOFFSETULN


C1B ON 3 6 10 0

SSOFFSETDLP SSOFFSETDLN QOFFSETULP QOFFSETULN QOFFSETDLP QOFFSETDLN


0 0 0
END

-------------------------------------------------------------------------------
<RLIMP:CELL=C1B;

CELL IDLE CHANNEL MEASUREMENT DATA

CELL ICMSTATE INTAVE LIMIT1 LIMIT2 LIMIT3 LIMIT4


C1B ACTIVE 6 2 6 12 22
END

-------------------------------------------------------------------------------
<RLLAP:LAI=ALL;

LOCATION AREA DATA

LAI
262-02-107

CELL
C7H

LAI
262-02-7

CELL
C7G

LAI
262-02-2

CELL
C1G UC11 UC12

LAI
262-02-3

CELL
ER1A ER1B

LAI
262-02-106

CELL
C1B C1D C1F MC1H

LAI
262-02-6

CELL
C1A C1E D1K
END

-------------------------------------------------------------------------------
<RLLBP;

BSC LOCATING DATA

SYSTYPE
GSM

TAAVELEN TINIT TALLOC TURGEN EVALTYPE THO NHO


4 10 2 2 1 30 3
ASSOC IBHOASS IBHOSICH IHOSICH
ON ON ON ON

SYSTYPE
DCS1800

TAAVELEN TINIT TALLOC TURGEN EVALTYPE THO NHO


4 10 2 2 1 30 3

ASSOC IBHOASS IBHOSICH IHOSICH


ON ON ON ON

SYSTYPE
PCS1900

TAAVELEN TINIT TALLOC TURGEN EVALTYPE THO NHO


4 10 2 2 1 30 3

ASSOC IBHOASS IBHOSICH IHOSICH


ON ON ON ON
END

-------------------------------------------------------------------------------
<RLLCP:CELL=C1B;

CELL LOAD SHARING DATA

CELL CLSSTATE CLSLEVEL CLSACC HOCLSACC RHYST CLSRAMP


C1B INACTIVE 20 40 OFF 75 5
END

-------------------------------------------------------------------------------
<RLLDP:CELL=C1B;

CELL LOCATING DISCONNECT DATA

CELL MAXTA RLINKUP


C1B 62 3
END

-------------------------------------------------------------------------------
<RLLFP:CELL=C1B;

CELL LOCATING FILTER DATA


CELL SSEVALSD QEVALSD SSEVALSI QEVALSI
C1B 6 6 6 6

SSLENSD QLENSD SSLENSI QLENSI SSRAMPSD SSRAMPSI


10 12 10 12 5 2
END

-------------------------------------------------------------------------------
<RLLHP:CELL=C1B;

CELL LOCATING HIERARCHICAL DATA

CELL TYPE LEVEL LEVTHR LEVHYST PSSTEMP PTIMTEMP FASTMSREG


C1B INT 2 75 2 0 0 OFF
END

-------------------------------------------------------------------------------
<RLLLP:CELL=C1B;

SUBCELL LOAD DISTRIBUTION DATA

CELL SCLD SCLDUL SCLDLL


C1B OFF 30 20
END

-------------------------------------------------------------------------------
<RLLOP:CELL=C1B;

CELL LOCATING DATA

CELL BSPWR BSRXMIN BSRXSUFF MSRXMIN MSRXSUFF SCHO MISSNM AW


C1B 35 110 105 102 93 ON 3 OFF

SCTYPE BSTXPWR EXTPEN HYSTSEP


35 90
END

-------------------------------------------------------------------------------
<RLLPP:CELL=C1B;

CELL LOCATING PENALTY DATA

CELL PTIMHF PTIMBQ PTIMTA PSSHF PSSBQ PSSTA


C1B 15 10 30 20 20 20
END

-------------------------------------------------------------------------------
<RLLSP;

BSC LOAD SHARING STATUS

LSSTATE
ACTIVE
END

-------------------------------------------------------------------------------
<RLLUP:CELL=C1B;

CELL LOCATING URGENCY DATA

CELL SCTYPE QLIMUL QLIMDL TALIM CELLQ


C1B 70 70 59 LOW
END

-------------------------------------------------------------------------------
<RLMBP:ID=ALL;

CELL BROADCAST SHORT MESSAGE SERVICE


MESSAGE DATA

NONE
END

-------------------------------------------------------------------------------
<RLMFP:CELL=C1B;

CELL MEASUREMENT FREQUENCIES

CELL
C1B

LISTTYPE
IDLE

MBCCHNO
1 2 4 5 6 10 11
LISTTYPE
ACTIVE

MBCCHNO
1 2 4 5 6 10 11

TEST MEASUREMENT FREQUENCIES

MBCCHNO

END

-------------------------------------------------------------------------------
<RLMTP:CELL=C1B,ID=ALL;

CELL BROADCAST SHORT MESSAGE SERVICE


MESSAGE DISTRIBUTION DATA

CELL CBCHLOAD
C1B 0

NONE
END

-------------------------------------------------------------------------------
<RLNCP:CELL=C1B;

NEIGHBOUR TO CELLS

CELL
C1B

IS NEIGHBOUR TO

UC12 MC1H C1G C1A


END

-------------------------------------------------------------------------------
<RLNRP:CELL=C1B,CELLR=ALL;

NEIGHBOUR RELATION DATA

CELL
C1B

CELLR DIR CAND CS


C3A SINGLE BOTH

KHYST KOFFSETP KOFFSETN LHYST LOFFSETP LOFFSETN


3 0 3 0

TRHYST TROFFSETP TROFFSETN AWOFFSET BQOFFSET


2 0 5 3

HIHYST LOHYST OFFSETP OFFSETN


5 3 0

CELLR DIR CAND CS


C2A SINGLE BOTH

KHYST KOFFSETP KOFFSETN LHYST LOFFSETP LOFFSETN


3 0 3 0

TRHYST TROFFSETP TROFFSETN AWOFFSET BQOFFSET


2 0 5 3

HIHYST LOHYST OFFSETP OFFSETN


5 3 0

CELLR DIR CAND CS


UC12 MUTUAL BOTH NO

KHYST KOFFSETP KOFFSETN LHYST LOFFSETP LOFFSETN


3 0 3 0

TRHYST TROFFSETP TROFFSETN AWOFFSET BQOFFSET


2 0 5 3

HIHYST LOHYST OFFSETP OFFSETN


5 3 0

CELLR DIR CAND CS


MC1H MUTUAL BOTH NO

KHYST KOFFSETP KOFFSETN LHYST LOFFSETP LOFFSETN


3 0 3 0
TRHYST TROFFSETP TROFFSETN AWOFFSET BQOFFSET
2 0 5 3

HIHYST LOHYST OFFSETP OFFSETN


5 3 0

CELLR DIR CAND CS


C1G MUTUAL BOTH NO

KHYST KOFFSETP KOFFSETN LHYST LOFFSETP LOFFSETN


3 0 3 0

TRHYST TROFFSETP TROFFSETN AWOFFSET BQOFFSET


2 0 5 3

HIHYST LOHYST OFFSETP OFFSETN


5 3 0

CELLR DIR CAND CS


C1A MUTUAL BOTH NO

KHYST KOFFSETP KOFFSETN LHYST LOFFSETP LOFFSETN


3 0 3 0

TRHYST TROFFSETP TROFFSETN AWOFFSET BQOFFSET


2 0 5 3

HIHYST LOHYST OFFSETP OFFSETN


5 3 0
END

-------------------------------------------------------------------------------
<rlolp:cell=c1g;

CELL LOCATING OVERLAID SUBCELL DATA

CELL LOL LOLHYST TAOL TAOLHYST


C1G 92 2 8 3
END

-------------------------------------------------------------------------------
<RLOMP;

BSC BAND OPERATION MODE DATA


MODE
MULTI
END

-------------------------------------------------------------------------------
<RLPBP:CELL=C1B;

HANDOVER POWER BOOST DATA

CELL HPBSTATE
C1B INACTIVE
END

-------------------------------------------------------------------------------
<RLPCP:CELL=C1B;

DYNAMIC MS POWER CONTROL CELL DATA

CELL DMPSTATE
C1B INACTIVE

SCTYPE SSDES SSLEN LCOMPUL INIDES PMARG INILEN QDESUL QLEN


85 5 70 70 8 2 20 8

QCOMPUL REGINT DTXFUL


30 5 5
END

-------------------------------------------------------------------------------
<RLPPP:PP=ALL;

BSC DIFFERENTIAL CHANNEL ALLOCATION PRIORITY PROFILE DATA

PP PRL INAC PROBF


NORMAL 1 10 10
2 10 10
3 10 10
4 10 10
5 10 10
6 10 10
7 10 10
8 100 0
9 0 0
10 10 10
11 10 10
12 10 10
13 10 10
14 10 10
15 10 10
16 10 10
DEFAULT 1 0 0
2 0 0
3 0 0
4 0 0
5 0 0
6 0 0
7 0 0
8 0 0
9 0 0
10 0 0
11 0 0
12 0 0
13 0 0
14 0 0
15 0 0
16 0 0
END

-------------------------------------------------------------------------------
<RLPRP:CELL=C1G;

BSC DIFFERENTIAL CHANNEL ALLOCATION


PRIORITY PROFILE RESOURCE TYPE DATA

CELL SCTYPE CHTYPE CHRATE PP


C1G UL SDCCH DEFAULT
UL TCH FR NORMAL
UL TCH HR DEFAULT
OL SDCCH DEFAULT
OL TCH FR DEFAULT
OL TCH HR DEFAULT
END

-------------------------------------------------------------------------------
<RLSBP:CELL=C1B;

CELL SYSTEM INFORMATION BCCH DATA


CELL
C1B

CB MAXRET TX ATT T3212 CBQ CRO TO PT ECSC


NO 7 7 NO 0 LOW 0 0 0 NO

ACC
CLEAR
END

-------------------------------------------------------------------------------
<RLSCP;

BSC DIFFERENTIAL CHANNEL ALLOCATION STATISTICS COLLECTION DATA

STATE STATSINT TIME


OFF
END

-------------------------------------------------------------------------------
<RLSDP:CELL=C1B;
ORDERED

<

CELL DIFFERENTIAL CHANNEL ALLOCATION STATISTICS DATA

CELL
C1B

CHTYPE CHRATE PRL PRLMSESTB PRLNDROP


TCH FR 1 0 0
2 0 0
3 0 0
4 0 0
5 0 0
6 0 0
7 0 0
8 0 0
9 0 0
10 0 0
11 0 0
12 0 0
13 0 0
14 0 0
15 0 0
16 0 0
TCH HR 1 0 0
2 0 0
3 0 0
4 0 0
5 0 0
6 0 0
7 0 0
8 0 0
9 0 0
10 0 0
11 0 0
12 0 0
13 0 0
14 0 0
15 0 0
16 0 0
SDCCH 1 0 0
2 0 0
3 0 0
4 0 0
5 0 0
6 0 0
7 0 0
8 0 0
9 0 0
10 0 0
11 0 0
12 0 0
13 0 0
14 0 0
15 0 0
16 0 0

SCTYPE CHTYPE CHRATE PRL PRLRTCALLS PRLRTCONGS


TCH FR 1 0 0
2 0 0
3 0 0
4 0 0
5 0 0
6 0 0
7 0 0
8 0 0
9 0 0
10 0 0
11 0 0
12 0 0
13 0 0
14 0 0
15 0 0
16 0 0
TCH HR 1 0 0
2 0 0
3 0 0
4 0 0
5 0 0
6 0 0
7 0 0
8 0 0
9 0 0
10 0 0
11 0 0
12 0 0
13 0 0
14 0 0
15 0 0
16 0 0
SDCCH 1 0 0
2 0 0
3 0 0
4 0 0
5 0 0
6 0 0
7 0 0
8 0 0
9 0 0
10 0 0
11 0 0
12 0 0
13 0 0
14 0 0
15 0 0
16 0 0
END
-------------------------------------------------------------------------------
<RLSLP:CELL=C1B;

CELL SUPERVISION OF LOGICAL CHANNEL AVAILABILITY DATA

CELL SCTYPE
C1B

ACTIVE CHTYPE CHRATE SPV LVA ACL NCH


NO BCCH 1 A3 1
SDCCH 0 A3 8
TCH FR 1 0 A3 6
TCH FR 2 0 A3 6
TCH HR 1 0 A3 12
CBCH 0 A3 0
END

-------------------------------------------------------------------------------
<RLSMP:CELL=C1B;

CELL SYSTEM INFORMATION BCCH MESSAGE DISTRIBUTION

CELL SIMSG MSGDIST


C1B 1 ON
7 OFF
8 OFF
END

-------------------------------------------------------------------------------
<RLSSP:CELL=C1B;

CELL SYSTEM INFORMATION SACCH AND BCCH DATA

CELL
C1B

ACCMIN CCHPWR CRH DTXU RLINKT NECI MBCR


100 29 2 2 4 0 0

NCCPERM
1
END
-------------------------------------------------------------------------------
<RLSTP:CELL=C1B;

CELL STATUS

CELL STATE
C1B ACTIVE
END

-------------------------------------------------------------------------------
<RLTYP;

BSC SYSTEM TYPE DATA

GSYSTYPE
MIXED
END

-------------------------------------------------------------------------------
<RLVAP;

CELL SEIZURE SUPERVISION OF LOGICAL CHANNELS ALARMED OBJECTS DATA

NEVER USED CHANNELS

CHANNEL CELL STATE


NONE

CONTINUOUSLY BUSY CHANNELS

CHANNEL CELL STATE


NONE
END

-------------------------------------------------------------------------------
<RLVLP;

CELL SEIZURE SUPERVISION OF LOGICAL CHANNELS DATA

CHANNEL TYPE SUPERVISION DATA

CHTYPE ACL PL STATUS SUPSTATE


TCH A3 72 PASSIVE
SDCCH A3 72 PASSIVE

CELLS INCLUDED IN SUPERVISION

CELL TCH SDCCH


NONE
END

<

======================================================================
= MSC ================================================================
======================================================================

Mobile Traffic recording


------------------------
INMCT:SPG=0;
INFII:FILE=MTRFIL00,VOL=EXCHVOLUME,RLENGTH=512,TYPE=SEQ,SIZE=30,EXP=10,FCLASS=CM
P;
END;
INFDI:FILE=MTRFIL00,DEST=IOS; ! Define the MTRFIL00 in the filesystem !
IOIFI:FILE=MTRFIL00,NSUB=10; ! Insert a MTRFIL00 in the filesystem !

(MSC)
MGBRI:IMSI=460091000000010,RTY=2,RR=0,ACCT=ALL;
MGBRE:IMSI=460091000000010;
MGBRP:IMSI=ALL; ! MT BSC RECORDING INITIATION DATA !

INFDR:FILE=MTRFIL00,DEST=IOS; ! INFINITE SEQUENTIAL ACTIVE FILE END !


IOIFR:FILE=MTRFIL00; ! INFINITE SEQUENTIAL FILE REMOVAL !
INMCT:SPG=0;
INFIR:FILE=MTRFIL00;
END;

IOIFP; ! FILE ATTRIBUTE INFINITE SEQUENTIAL FILE !


INFDP; ! FPU DESTINATION LIST !
IOFAT:FILE=MTRFIL00-0001,HEX;

======================================================================
= STS ================================================================
======================================================================
SDDOP:AREA=oper,OBJTYPE=celeventd&celeventh; ! Print sts data base definition !
SDTDP:rptid=101,int=5; ! Receive sts report !

Decrease number of objects in sts database


------------------------------------------
IMLIT:SPG=0;
SDDOI;
SDDOC:AREA=OPER;OBJTYPE=celeventd,NOBJ=x;
SDDOC:AREA=OPER;OBJTYPE=celeventh,NOBJ=x;
SDDOE:EXEC;
END;

Start collection
----------------
IMLIT:SPG=0;
SDDCI;
END;

======================================================================
= IOG HANDLING =======================================================
======================================================================

Mount and Unmount an IO


-----------------------
INMCT:SGG=0;
INVOL:IO=OD-1,NODE=B;
END;
INMCT:SGG=0;
INVOE:IO=OD-1,NODE=B;
END;

Copy a dump from HD to OD


-------------------------
SYMTP:DIR=OUT,SPG=0,NODE=B,IO2=OD-1,FILE1=RELFSW1,FILE2=NAME;

Copy a dump from OD to HD


-------------------------
SYMTP:DIR=IN,SPG=0,NODE=B,IO2=OD-1,FILE1=RELFSW1,FILE2=NAME;

======================================================================
= Function Change ====================================================
======================================================================
Function change Lower SW VER to Higher SW VER - from Optical Disk
---------------------------------------------------

INMCT:SPG=0; ! Mount the volume - the Optical Disk !


INVOL:SPG=0,IO=OD-1,NODE=B ! Could also be node A !
END;

INMCT:SPG=0; ! Print the data on the OD !


INFIP:FILE=OD0B1;
INFIP:FILE=OD0B1-LO-LADIRECT;
INFIP:FILE=OD0B1-LO-RXOTX;
END;

SYRSI,SPG=0,NODE=B,RANK=RELOAD; ! Restart the IOG, if needed !


SP NODE RESTARTED ! Wait for printout !

RXAPE:MO=mo,DCP=ALL; ! Undefine Abis paths and MOs !


RXMOE:MO=mo;

EXSLP:SPG=0; ! Print SP LINK DATA !


DPWSP; ! Print CP STATE !

FCSLI:SPG=0; ! Separate the link !


CONNECTION INTERRUPTED ! Wait for the one of printouts !
SP LINK SEPARATION EXECUTED

IMLCT:SPG=0; ! Separate an IO terminal !


MCSDC:IO=AT-SB,SEP=YES;
END;

FCSEI; ! Separate the CP (AT-EX) !


CP STATE NOT NORMAL ! Wait for tha alarm !

SYSTEM RESTARTED ! Wait for printout (at AT-SB) !

LASUR:BLOCK=RXCBM&RXCCD&RXCCL&RXCCO&RXCCOR;
! Remove the blocks that are going to !
! be replaced !
LASUL:BLOCK=ALL; ! Load the new blocks !
LOADING RESULT ! Wait for printout !

CACLS:DATE=yymmdd,DAY=day,TIME=hhmm;
! Set date and time !

SYATI; ! Start the application software (AT-SB)!


APPLICATION BLOCKS STARTED ! Wait for printout !

IOEXC:EXCHANGE=" ";
! Change the Exchange Identity (AT-SB) !

FCSWI:CTYPE=NOTR; ! Switch in SB side as EX side (AT-EX) !


SYSTEM RESTARTED ! Wait for printout (at AT-EX) !

DPWSP; ! Make sure that the sideswitch was !


SYRIP:SURVEY; ! successful (AT-EX) !

RXMOI:MO=mo,...; ! Define MOs and Abis paths !


RXAPI:MO=RXOTG-tg,DEV=RBLT-xx&&-yy,DCP=x&&xx;
! Load necessary ECs !

DPPAI; ! Return to parallel in CP (AT-EX) !


CP SB START PASSED ! Wait for printout !

IMLCT:SPG=0; ! Remove the separated link !


MCDSC:IO=AT-SB,SEP=NO;
END;

BLSLE:SPG=0,LINK=link; ! Deblock the separated link !


SP LINK DEBLOCKING EXECUTED ! Wait for printout !

Change CP block !RXETS!


-----------------------
INMCT:SPG=0;
INVOL:IO=OD-1,NODE=B; ! Mounte the OD !
END;

INMCT:SPG=0;
INFIP:FILE=LO; ! Print LO blocks !
INFET:FILE1=LO-RXETS,FILE2=RXETS,NODE2=B,IO2=FD-1;
! Copy the file to the harddisc !
END;
INMCT:SPG=0;
INVOE:IO=OD-1,NODE=B; ! UnMounte the OD !
END;

FCSLI:SPG=0; ! Separate the link !


EXSLP:SPG=0; ! Check the links !

FCSEI; ! Separate the CP !


DPWSP; ! Check the CP state !

MCLOC:USR=SYSTEM,PSW=INIT;
MCDSC:IO=AT-0,SEP=YES; ! Separate your working IO !
EXIT;

MCLOC:USR=SYSTEM,PSW=INIT;
SYSRI:START; ! Order a start, passivate blocks !

LASUR:BLOCK=RXETS; ! Remove old block !


LASUL:BLOCK=RXETS; ! Add new block !

SYATI; ! Start application blocks !

CACLS:DAY=FRI,TIME=0909,DATE=971121;
! Set Time and date !
FCSWI:CTYPE=NOTR; ! Switch this side to executive !

DPPAI; ! Turn to parallell mode (on other IO)!

MCLOC:USR=SYSTEM,PSW=INIT;
MCDSC:IO=AT-5,SEP=NO; ! DeSeparate your working IO !
EXIT;

======================================================================
= RP =================================================================
======================================================================

Diverse
-------
EXRPP:RP=all; ! Print RP DATA, Check RPD1A !

EXRUP:RP=96; ! Print RP SOFTWARE UNIT DATA! !

FCRWS:RP=108,WS=SEP; ! Separate RPs !

BLRPE:RP=108&109; ! Deblock RPs !


BLRPI:RP=108&109; ! Block RPs !

Change of RP software !RHLAPDR!


-------------------------------
LAEIP:SUNAME=ALL; ! Print all RP units !
LAEIP:SUNAME=RHLAPDR; ! Check the current version !
LAEUP:suid="CAA 140 1058 R1A03";! Check the identifications !

INMCT:SPG=0;
INFIP:FILE=EMRP; ! Check file attributes on harddisc !
INFIR:FILE=EMRP-COMP; ! delete the old files on harddisc !
INFIR:FILE=EMRP-RHLAPDR; ! delete the old files on harddisc !
END;

INFET:IO1=OD-1,NODE1=b,FILE1=com,FILE2=emrp-comp;
! Copy file from diskett !
INFET:IO1=OD-1,NODE1=b,FILE1=rhl,FILE2=emrp-rhlapdr;
! Copy file from diskett !

LAEUL:SUNAME=RHLAPDR; ! Load the software from the hd !

FCEPS;
ENTER OLD SU !OLDSUID/OLDSUNAME =! : :oldsuid="CAA 140 1058 R1A03";
ENTER NEW SU !NEWSUID/NEWSUNAME =! : :newsuid="CAA 140 1058 R1A02";
ENTER RP NUMBER !RP =! : :rp=52;! From LAEIP:SUNAME=ALL; !RPD1A! !
ENTER RP NUMBER !RP =! : :rp=53;! From LAEIP:SUNAME=ALL; !RPD1A! !
ENTER RP NUMBER !RP =! : :end;
ENTER HW CHANGE INFORMATION !HW =! YES/NO : :hw=no;
ENTER EM NUMBER !EM =! : :em=0;
ENTER EM NUMBER !EM =! : :end;
ENTER RP NUMBER !RP =! : :end;

FCELI;
FCEPI; ! EM Function Change Prepared !
FCEPC; ! EM Function Change !
EXRUP:RP=52&53; ! Check that the new RP sw is loaded !

======================================================================
= LOAD EXCHANGE DATA =================================================
======================================================================

Load the Ref dump - Initial start


---------------------------------

SYBFP:FILE; ! Check the files !

DPWSP; ! Print CP state !


EXSLP:SPG=0; ! Print IOG links, note RP !

FCSLI:SPG=0; ! Separate the IOG links !


FCSEI; ! Separate CP !
FCCPL:RP=4,FILE=RELFSW1; ! Load into SB side !

! Wait for SYSTEM START or LOAD RESULT printout, may take 30 minutes !

EXIT;

CACLS:DAY=TUE,DATE=980317,TIME=1541;
! Set the correct time !
SYATI; ! Start application blocks !

FCSWI:CTYPE=NOTR; ! Update Standby side to Executive !


! Large restart !

! Byt IO terminal !

MCLOC:USR=SYSTEM,PSW=INIT; ! Go into local mode !


MCDSC:IO=AT-5,SEP=NO; ! unseperate IO terminal !

EXIT;

DPPAI; ! Take into parrallel !

Load exchange data


------------
Make sure to get the correct SUIDs.
LAEIP:SUNAME=REXR;

Change dump name and dump it out.

======================================================================
= PROCESSOR LOAD =====================================================
======================================================================
PLLDP; ! PRINT PROCESSOR LOAD !
MEFBI:TIME=1336,TDMI=5,TDS=1,BLOCK=RXO3OM,IO=OWN;
! More accurate measure of processor load !

======================================================================
= Size Alteration ====================================================
======================================================================

SAAEP:BLOCK=MFM,SAE=812;
SAAEP:BLOCK=MFM,SAE=813;
SAAII:BLOCK=MFM,SAE=812,NI=7;
SAAII:BLOCK=MFM,SAE=813,NI=30;

Size alteration of DS store


---------------------------
SASTP; ! Print STORE UTILIZATION !
DPSES; ! Separate CP !
SASTS:STORE=DS,NRMW=85; ! Change size of DS !
DPPAI; ! Go back to paralell !

======================================================================
= SRS ================================================================
======================================================================

Commands from when the TSs didn't work at pooled TRA


----------------------------------------------------

NTSTP:SNT=SRS-0; ! Check the state ot the SRS !


SAAEP:BLOCK=SRS,SAE=529;
SAAEP:BLOCK=SRSTRAF,SAE=529;
EXRPP:RP=ALL;
DIRRP:RP=50;
BLRPE:RP=50;
EXEMP:RP=50,EM=ALL;
EXEMP:RP=51,EM=ALL;
BLRPE:RP=50;
BLRPI:RP=50;
BLRPE:RP=50;
EXEMP:RP=50,EM=ALL;

======================================================================
= GS =================================================================
======================================================================

GSSTP; ! Group switch state !

======================================================================
= APZ diverse ========================================================
======================================================================

LAFBP:BCM=ALL;
LASIP:BLOCK=RCOMA; !Find Block Number!
LASAL;
LASLP:BLOCK=RCOMA; !Storage Layout!
LASAP:SIGNAL=RCLOADBANDMODE; !GSN!
LAGTP:SIGNAL=RCLOADBANDMODE,BLOCK=RCOMA; !LSN!

PLLDP; !Print Processor Load!

SYBCS; !Change block category for a block!

SYBFP:FILE; !SYSTEM BACKUP FILES, PRINT!


SYBUP:FILE=RELFSW1; !MAKE A SYSTEM BACKUP COPY!

DTSTP:DIP=ALL; !Digital Path Transmission State, Print!


DTSTP:DIP=RILT0;

DPWSP; !Print CP working state!

RECCI; ! Check after repair of CP !


! To get CP's are in parallell !
DPPAI; ! To get CP's are in parallell !

Set time and date


-----------------
CACLS:TIME=1503,DATE=981026,DAY=mon;

IOEXC:EXCHANGE=""; !Change dump name!

SPG - SUPPORT PROCESSOR GROUP


-----------------------------

EXSLP:SPG=0; ! Print SP LINK DATA !


FCSLI:SPG=0; ! Separate link !

BLSLI:SPG=0,LINK=0; ! Block SP LINK !


BLSLE:SPG=0,LINK=0; ! Deblock SP LINK !

BLSNI:SPG=0,NODE=A; ! Block SP NODE !


BLSNE:SPG=0,NODE=A; ! Deblock SP NODE !

======================================================================
= Restart ============================================================
======================================================================

SYREI:RANK=LARGE;
SYRAP; !Printing System recovery actions!
SYRAC; !Change System recovery actions!
SYRIP:LOG; !Print Recovery and error information!
SYRIP:SURVEY;
SYRIP:EVENT=35;

SYRAE; !Reset the alarm system restart - COMMAND!


SYRAE:RECTYPE=APPLERR; !Reset the alarm system restart - APPL ERR!
SYRAE:RECTYPE=SOFTERR; !Reset the alarm system restart - SW ERR!

======================================================================
= FORLOPP ============================================================
======================================================================
SYFSC:FLERROR=ON; !Activate FORLOPP!
SYFSP; !Printout Forlopp status!
SYFSC:FLSTATUS=ACTIVE; !Activate FORLOPP!
SYFAP; !Printing FORLOPP!

SYFIP:FID=H'025E-0001; !Printing individuals connected to a FORLOPP!


SYFRI:FID=H'1BC-0,BLOCK=RXCMOO,FILENUM=1,IND=;
!Manual FORLOPP release!

SYRAC:FORLOPPRES=ACTIVE; ! Forlopp release function is set to active !


! for APZ detective faults !

Turn FORLOPP Off


----------------
SYFSC:FLERROR=OFF; !Passivate FORLOPP!
@e
SYFSC:FLSTATUS=PASSIVE; !Passivate FORLOPP!
SYFSP; !Printout Forlopp status!

Turn FORLOPP On
---------------
SYFSC:FLERROR=ON; !Activate FORLOPP!
@e
SYFSC:FLSTATUS=ACTIVE; !Activate FORLOPP!

Printing the FIR


----------------

PRINT REG 4/H'9F,PRINT REG 4/H'9E,;

This can be combined with any of the standard tracing measures


Eg to see the FIR sent with a signal;

ON IN RXE3EP RXTSPARAM1;
ON IN DO:P SWD,P REG 4/H'9F,P REG 4/H'9E,;
INIT;

======================================================================
= FILES and IO =======================================================
======================================================================

IO Subsystem Functions File Management Functions


------------------------------------------------

INMIT:SPG=0; ! IO subsystems functions file Management !


! Functions Initiate, Transfer !
INMCT:SPG=0; ! Change, Transfer !

SubCommands:
INFIP; ! Check the files !
INFIP:VOL=RELVOLUMSW;

INVOP;
INVOP:VOL=RELVOLUMSW; !Check VOLUME ATTRIBUTES INTERNAL !

END;

IO Maintenance Data Link Functions


----------------------------------

IMLCT:SPG=0;

SubCommands:

MCDVP; !Printout of the status of the IOs!

END;

Change dump - Reload


--------------------
SYBFP:FILE; !Check the files!
INMCT:SPG=0;
INFIC:FILE1=RELFSW0,FILE2=TEMPFIL; !Move file0 to temp!
END;
INMCT:SPG=0;
INFIC:FILE1=RELFSW3,FILE2=RELFSW0; !Move your file to file0!
END;
INMCT:SPG=0;
INFIC:FILE1=TEMPFIL,FILE2=RELFSW3; !Move temp to your old file!
END;
SYREI:RANK=RELOAD; !RELFSW0 is loaded!
DPWSP; !Check the state of the CP!

Dumping to IOG11, Separated side


--------------------------------
! Check the disc space !
SYBFP:FILE; ! Find the file to dump to !
IOEXC:EXCHANGE=" "; !Change dump name!

DPWSP; ! Check CP state, parallell or not !


DPPAI; ! IF not parallell !

EXSLP:SPG=0; ! Check the link STATE !


FCSLI:SPG=0; ! Sep link, (If STATE not SEP) !

FCSEI; ! Sep SB side !

MCLOC:USR=SYSTEM,PSW=INIT;
MCDSC:IO=AT-N,SEP=YES; ! Separera IO !

LASIP:BLOCK=RXOPAC; ! Check blocks started, !


SYATI; ! If blocks not started !

SYBUP:FILE=RELFSWX; ! MAKE SYSTEM BACKUP COPY, !


! Can take upto 1.5 hours !

! Change IO !

MCLOC:USR=SYSTEM,PSW=INIT;
MCDSC:IO=AT-N,SEP=NO; ! DeSeparera IO !

DPPAI;

Fixing a IO device that is not working


--------------------------------------
IOIOP:IO1=ALL; ! PRINT STATE OF IOS !
IOBLE:IO=AT-2; ! DEBLOCK IO DEVICE !
IOIOI:IO=AT-2; ! DEFINE IO DEVICE !
IOIOI:IO=AT-2,COMATT; ! DEFINE ALPHA IO DEVICE !
IOIOR:IO=AT-2; ! EEMOVE IO DEVICE !

IOROI:IO=AT-2;
IOROP:IO=AT-2;
IOROP; ! Print all ATs !

IMLCT:SPG=0;
MCDVP; ! PRINT MCS IO DEV DATA !
ILNPP; ! PRINT DCS PORT DATA !

ILBLI:NP=1-1-1-1; ! BLOCK !
ILBLE:NP=1-1-1-1; ! DEBLOCK !
END;

======================================================================
= PRINTOUT ROUTING ===================================================
======================================================================

IOROL:PRCA=0 && 31, DTYPE=FIRST, IO=AT-2 ;


IOROL:PRCA=0 && 31, DTYPE=STB, IO=AT-5 ;
IOROI:PRCA=0 && 31 ;

IOROL:PRCA=32&& 63, DTYPE=FIRST, IO=AT-2 ;


IOROL:PRCA=32&& 63, DTYPE=STB, IO=AT-5 ;
IOROI:PRCA=32&& 63 ;

IOROL:PRCA=64&& 95, DTYPE=FIRST, IO=AT-2 ;


IOROL:PRCA=64&& 95, DTYPE=STB, IO=AT-5 ;
IOROI:PRCA=64&& 95 ;

IOROL:PRCA=96&& 127,DTYPE=FIRST, IO=AT-2 ;


IOROL:PRCA=96&& 127,DTYPE=STB, IO=AT-5 ;
IOROI:PRCA=96&& 127 ;

======================================================================