Instrument Information

Instrument Name

Serial number

Installation Site contact details


(optional)

Check date

Revision list
Revision Date Description Editor
01 02.09.2020 First Revision Alexandra Scherer

Contents
1. Special tools.............................................................................................................................................. 1
2. Accompanying documents ..................................................................................................................... 1
3. Pre-Installation checklist ......................................................................................................................... 2
4. Closure ...................................................................................................................................................... 5
5. Additional notes....................................................................................................................................... 5

1. Special tools

2. Accompanying documents

Pre-Installation Report

Page 1 of 5
Elisys Uno Pre-Installation Report Revision 01 Page 2 von 5

3. Pre-Installation checklist
System

 Elisys Uno

Analyzer location

Is the installation site the final location of the analyzer?  Yes  No


Remarks:

 Required space provided


Measurements:
Width: __________ cm Depth: __________ cm Hight: __________ cm
WxDxH (System): 102 x 55 x 47 cm
WxDxH (required space): 170 x 80 x 80* cm
* Width and depth are minimum values. Height with door opens (incl. 75 cm workbench height).
Extra space for PC, monitor, mouse, keyboard and printer necessary

 Workbench payload sufficient


Gross weight: 70 kg Net weight: 35 kg

 Workbench height: __________ cm  No direct sunlight

 Environmental preconditions met  A/C provided


Ambient temperature: 18°C to 35°C Air flow and dust according to DIN Lab terms
Temperature variation not to exceed ±2°C Minimum Air flow (25 m³ /hr./m²)
during analysis
Humidity: 10% to 80% relative with no condensation
Altitude: ≤ 2000 m
Altitude: _____ m

 No vibrations via motors (centrifuge, etc.)  A/C not directly above the installation place

 No strong electromagnetic interface  No wet/damp conditions

Pre-Installation Report

Page 2 of 5
Elisys Uno Pre-Installation Report Revision 01 Page 3 von 5

Delivery
WxDxH (Box): 120 x 80 x 93 cm
Weight Box: 70 kg
 Required space for transport provided
Measurements:
Width: __________ cm Hight: __________ cm
 Delivery per hand lift possible
 Delivery to floor __________
 Ramp provided
 Goods hoist or elevator provided

 Packaging material has to be taken away

 Help for installation provided (2 persons necessary)


Contact:

Electrical connection

 AC input: 100 – 240 V 50/60 Hz


 Frequency range:
 Power consumption: 160 VA
 3 separate, grounded sockets DIN (analyser + PC, monitor, printer)
Online UPS min. 800 VA available or ordered for the new analyser  Yes  No
 Separate ground (max. Voltage between ground and neutral: 1 V) provided

Water supply

 Water quality supplied (test report attached)


Requirement: Quality ISO3696, 0.1 to 1.0 µS/cm

Sample tube
(Please note the planned sample tube(s) used on the analyzer)
Sample tube (dimension, model, type):
 Sample cups or primary tubes: Ø 12 – 13 mm, max. 100 mm height
 Calibrator vessel dimensions: Ø 12 – 20 mm, max. 90 mm height
 Reagent vessel dimensions: Ø 17 mm, max. 100 mm height
Ø 25 mm, max. 100 mm height
Ø 27 mm, max. 100 mm height
Ø 40 mm, max. 100 mm height

Pre-Installation Report

Page 3 of 5
Elisys Uno Pre-Installation Report Revision 01 Page 4 von 5

Planned methods used on the analyzer


Ensure that all required reagents, controls & calibrators are available during the installation for all
methods.
Noted: They will be run on the analyzer during the installation.
Assay Yes/No Assay Yes/No
Please add tests which are not listed Please add tests which are not listed

Personal computer

PC available or ordered for the new analyzer:  Yes  No


 Printer, type:

Minimum requirements:
1GHz processor, 1 GB Ram
Windows ™ 7, 8.1 and 10 (32 bit)
USB 2.0 port
CD or DVD rom
Keyboard and mouse
SVGA monitor

Suggested improvements:
2GHz processor, 4 GB Ram
Windows ™ 7, 8.1, and 10 (64 bit)
4 USB 2.0 ports (instrument, mouse, keyboard, printer)
Ethernet or Wi-Fi card
DVD R/W

LIS interface

LIS connection desired:  Yes  No


Assumption of costs:  Yes  No
LIS company name:

Contact person laboratory IT:

Pre-Installation Report

Page 4 of 5
Elisys Uno Pre-Installation Report Revision 01 Page 5 von 5

Briefing, training

Does the customer already use Human equipment especially a comparable analyser:  Yes  No

 Minimum 2 members of staff to attend briefing:


1st name:

2nd name:

3rd name:

(the required briefing time depends on the knowledge of the users)


 Specific parameter/application in briefing:

Fixed dates

Delivery date:

Installation date:

Briefing date:

4. Closure

Customer's contact (name, title and date) + Signature Service contact (name, title and date) + Signature

5. Additional notes
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________

Pre-Installation Report

Page 5 of 5

You might also like