You are on page 1of 5

LCC WP Pills

Fieldwood Energy Ichalkil‐2DEL


07/04/17
LCC WP GRANULAR PILLS FORMULATION
Pill A1: Seal Objective from 40 to 750 microns.

Optiseal IV 65 Kg/m3
Flovis L 16 Lt/m3

SafeCarb 250 40 Kg/m3


SafeCarb 500 30 Kg/m3
Flovis L 16 Lt/m3

Schlumberger-Private
Pill A2: Seal Objective from 40 to 1000 microns.

SafeCarb 250 50 Kg/m3


SafeCarb 500 30 Kg/m3
SafeCarb 750 20 Kg/m3
Flovis L 12 Lt/m3

Pill A3: Seal Objective from 40 to 1500 microns,


extended by fiber.

SafeCarb 250 50 Kg/m3


SafeCarb 500 30 Kg/m3
SafeCarb 750 20 Kg/m3
FyberCarb 40 Kg/m3
Flovis L 8 - 10 Lt/m3
LCC WP CROSSLINK PILLS FORMULATION

Pill B1: Seal Objective from 100 to 1000 MD, differential pressure greater than 2,000 psi.

Safe Vis E or Flovis L 10 Lt/m3


Safe Link 110 527 Kg/m3

SAFE‐LINK* fluid‐loss‐control product comprises a chemically modified, crosslinked cellulose polymer

Schlumberger-Private
used primarily to control loss of clear brine fluid to the formation during completion or workover
operations. SAFE‐LINK additive controls fluid loss by applying a very viscous material across the
formation face, virtually stopping the flow of brine into the formation. SAFE‐LINK fluid‐ loss‐control
additive functions through a crosslinked polymer network that is held in place on the formation face.
The effectiveness of this product is not dependent on bridging solids or on viscous drag within the
formation matrix.
BASE BRINE ADDITIVE

It´s advisable add the following additive in the brine, in order to avoid reservoir damage and pill
degradation:

 Clay Inhibitor 2 %v/v.


 pH Control 0.5 Kg/m3.

Schlumberger-Private
 Biocide 0.3 Lt/m3.
LCC LAB TESTS

SLOT Test: In order to verifying the behavior and efficiency of the pills over fractures simulations.
Houston M-I SWACO Laboratory.

Schlumberger-Private
Blue: Pressure reading at the different
pressure intervals

Red: Volume of fluid passing through the


fracture

Green: Temperature Reading