FABIA 2000 > 1.2/40; 1.2/47 Engine, Fuel Injection
o1
Display group 074 - adaptation of exhaust gas recirculation valve
For engine with engine identification characters AZQ, BME
Fault read-out device in function 04 - basic setting
Ignition switched ON, engine switched off
‘System in besic setting 74> < Readout on display
xx Xx yoxx Text
Vv Vv %
1 2 3 4 |< Display field ‘Speaification Analysis
‘Adaption status ‘ADP OK
(ADP runs, ADP. OK
or ERROR)
Current poti value 0,0...100,0 % =
Max. stop 30..48V =
Zero position 03..15V =
Notes on display group 074:
‘+The adaptation of the exhaust gas recirculation valve occurs with the ignition on
+ The engine control unitis adapted to the exhaust gas recirculation valve by selecting display group 074 under func-
tion 04 Basic setting’. This adaption must always be performed if another EGR valve (or completely different e
gine) or arte eave STOTT TES SSS RT a a SY rere frorunt has been instale
Display group 076 - Exhaust gas recirculation
For engine with engine identification characters AZQ, BME
Engine idling
Fault read-out device in function 04 - basic setting
— Perform 5 short heavy accelerations up to max speed
‘System in besic setting 75> = Read out on display
roux mbar yoo mbar 9% x% Text
1 2 3 4 | Display field Specification Analysis:
Result: Test run’ Test System OK
OFF /Syst. OK. /Syst —
NOK.
EGR opening dimension 15.35% =
Intake manifold pressure difference below 10 mbar =
Intake manifold pressure difference for diagnosis flow O mbar
rate