2007−04
Processes
Multiprocess Welding
Description
File: MULTIPROCESS
Mil_Thank 4/05
TABLE OF CONTENTS
Directives
Low Voltage Directive: 73/23/EEC
Electromagnetic compatibility Directives: 89/336/EEC, 92/31/EEC
Machinery Directives: 98/37EEC, 91/368/EEC, 92/31/EEC, 133/04, 93/68/EEC
Standards
Arc Welding Equipment − Part 10: Electromagnetic Compatibility (EMC) Requirements.
IEC 60974-10 August 2002
Arc Welding Equipment − Part 1: Welding Power Sources. IEC 60974-1 Ed. 2.1
Degrees of Protection Provided By Enclosures (IP Code): IEC 60529 Ed. 2.1
Insulation Coordination For Equipment Within Low-Voltage Systems:
Part 1: Principles, Requirements And Tests. IEC 60664-1 Ed. 1.1
The product technical file is maintained by the responsible Business Unit(s) located at the manufacturing facility.
Additional Standards
Arc Welding Equipment − Part 2: Liquid Cooling Systems. IEC 60974-2 Ed. 1
Arc Welding Equipment − Part 3: Arc Striking And Stabilizing Devices. IEC 60974-3 Ed. 1
Arc Welding Equipment − Part 5: Wire Feeders. IEC 60974-5 Ed. 1
Arc Welding Equipment − Part 7: Torches. IC 60974-7 Ed.1
dec_stat_6/05
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
som _3/05
Y Warning: Protect yourself and others from injury — read and follow these precautions.
Arc rays from the welding process produce intense D Shut off shielding gas supply when not in use.
visible and invisible (ultraviolet and infrared) rays D Always ventilate confined spaces or use
that can burn eyes and skin. Sparks fly off from the approved air-supplied respirator.
weld.
D Wear an approved welding helmet fitted with a proper shade of fil-
ter lenses to protect your face and eyes when welding or watching
(see ANSI Z49.1 and Z87.1 listed in Safety Standards). HOT PARTS can cause severe burns.
D Wear approved safety glasses with side shields under your
helmet. D Do not touch hot parts bare handed.
D Allow cooling period before working on gun or
D Use protective screens or barriers to protect others from flash,
torch.
glare and sparks; warn others not to watch the arc.
D To handle hot parts, use proper tools and/or
D Wear protective clothing made from durable, flame-resistant mate-
wear heavy, insulated welding gloves and
rial (leather, heavy cotton, or wool) and foot protection.
clothing to prevent burns.
OM-2254 Page 2
1-3. Additional Symbols For Installation, Operation, And Maintenance
OVERUSE can cause OVERHEATING D High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
D Allow cooling period; follow rated duty cycle. communications equipment.
D Reduce current or reduce duty cycle before D Have only qualified persons familiar with
starting to weld again. electronic equipment perform this installation.
D Do not block or filter airflow to unit. D The user is responsible for having a qualified electrician prompt-
ly correct any interference problem resulting from the installa-
tion.
D If notified by the FCC about interference, stop using the
STATIC (ESD) can damage PC boards. equipment at once.
D Have the installation regularly checked and maintained.
D Put on grounded wrist strap BEFORE handling D Keep high-frequency source doors and panels tightly shut, keep
boards or parts. spark gaps at correct setting, and use grounding and shielding to
D Use proper static-proof bags and boxes to minimize the possibility of interference.
store, move, or ship PC boards.
OM-2254 Page 4
SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION
som _3/05
Y Avertissement : se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.
Y Indique un message de sécurité particulier Ce groupe de symboles signifie Avertissement ! Attention ! Risques
d’ÉLECTROCUTION, ORGANES MOBILES et PARTIES
CHAUDES. Consulter les symboles et les instructions afférentes
ci-dessous concernant les mesures à prendre pour supprimer
. Signifie NOTE ; n’est pas relatif à la sécurité. les dangers.
OM-2254 Page 6
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance
OM-2254 Page 8
SECTION 3 − DEFINITIONS
1/96
OM-2254 Page 9
1 Warning! Watch Out! There
are possible hazards as
shown by the symbols.
2 Electric shock from wiring can
kill.
3 Disconnect input plug or
1 2 3 4 5 6 power before working on
machine.
4 Hazardous voltage remains
on input capacitors after
power is turned off. Do not
V touch fully charged
V capacitors.
5 Always wait 60 seconds after
> 60 s V S-179 190-A power is turned off before
working on unit, OR
6 Check input capacitor voltage,
and be sure it is near 0 before
touching any parts.
4/96
4/96
S-179 309-A
2 3 4 5
1/96
OM-2254 Page 10
3-2. Rating Label For CE Products
212 946-D
OM-2254 Page 11
3-4. Symbols And Definitions
A Amperage Panel
Alternating
Current (AC) V Voltage
U0 Rated No Load
Voltage (Average) U1 Primary Voltage
U2 Conventional
Load Voltage X Duty Cycle
Hz Hertz IP Degree Of
Protection I2 Rated Welding
Current % Percent
Lift-Arc Trigger
Pulsed Hold Operation Single Phase Three Phase
(GTAW)
Voltage Sensing
Scratch Start TIG
Feeder
OM-2254 Page 12
SECTION 4 − INTRODUCTION
4-1. Specifications
RMS Amps Input at Rated Load
Max. Output, 60 Hz 3-Phase at NEMA
Voltage Amperage Open- Load Voltages and Class I Rating
Input Range in Range in Circuit IP
Power Rated Output CV Mode CC Mode Voltage Rating 230 V 400 V KVA KW
3-Phase 350 A at 34 10−38 V 5−425 A 75 VDC 23 36.1 20.6 14.2 13.6
VDC, 60%
Duty Cycle
*See Section 4-3 for Duty Cycle Rating.
80
70
60
VOLTS
50 SMAW GTAW
MAX MAX
40
30 GTAW
SMAW
80A
MN
20 0% ARC
CONTROL
25%
10 50%
75%
100%
0
0 100 200 300 400 500
AMPERAGE
B. CV Mode
100
90
80
70
60
VOLTS
50
MAX
40
30
20
MIN
10
0
0 100 200 300 400 5 00
AMPERAGE
217 836-A / 217 837-B
OM-2254 Page 13
4-3. Duty Cycle And Overheating
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, output stops, a
Help message is displayed and
cooling fan runs. Wait fifteen min-
utes for unit to cool. Reduce amper-
age or voltage, or duty cycle before
welding.
Y Exceeding duty cycle can
damage unit and void
warranty.
Overheating
0 A or V
15
OR
Minutes Reduce Duty Cycle
Ref. 219 523-A
Notes
OM-2254 Page 14
SECTION 5 − INSTALLATION
24 in
(610 mm)
Dimensions And Weight
94.8 lb (43 kg)
17 in
(432 mm)
12-1/2 in
(318 mm)
Location
4
18 in
(460 mm)
18 in
(460 mm)
OM-2254 Page 15
5-2. Connecting 3-Phase Input Power
Y Installation must meet all National
and Local Codes − have only quali-
fied persons make this installation.
Y Disconnect and lockout/tagout in-
put power before connecting input
3 conductors from unit.
Y Always connect green or green/
yellow conductor to supply
grounding terminal first, and nev-
= GND/PE Earth Ground
er to a line terminal.
4
. The Auto-Line circuitry in this unit au-
tomatically adapts the power source
to the primary voltage being applied.
Check input voltage available at site.
7
This unit can be connected to any in-
put power between 208 and 575 VAC
without removing cover to relink the
power source.
2 For Three-Phase Operation
1 Input Power Cord.
2 Disconnect Device (switch shown in
the OFF position)
3 Green Or Green/Yellow Grounding
Conductor
L1
4 Disconnect Device Grounding
3 L2 5 Terminal
5 Input Conductors (L1, L2 And L3)
6 L3
6 Disconnect Device Line Terminals
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
Connect input conductors L1, L2, and L3
1 to disconnect device line terminals.
7 Overcurrent Protection
Select type and size of overcurrent protec-
tion using Section 5-3 (fused disconnect
switch shown).
Close and secure door on disconnect
1 device. Remove lockout/tagout device,
and place switch in the On position.
Tools Needed:
OM-2254 Page 16
5-3. Electrical Service Guide
Y CAUTION: INCORRECT INPUT POWER can damage this welding power source. Phase to ground
voltage shall not exceed +10% of rated input voltage.
NOTE Actual input voltage should not be 10% less than minimum and/or 10% more than
maximum input voltages listed in table. If actual input voltage is outside this range,
output may not be available.
60 Hz Three Phase
Input Voltage 230 400
Input Amperes At Rated Output 36 20
Max Recommended Standard Fuse Rating In Amperes 1
Time-Delay 2 40 25
Normal Operating 3 50 30
Min Input Conductor Size In AWG 4 10 12
96 175
Max Recommended Input Conductor Length In Feet (Meters)
(29) (53)
Min Grounding Conductor Size In AWG 4 10 12
Notes
OM-2254 Page 17
5-4. Weld Output Terminals And Selecting Cable Sizes
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
Not Exceeding***
150 ft 200 ft 250 ft 300 ft 350 ft 400 ft
100 ft (30 m) or Less
(45 m) (60 m) (70 m) (90 m) (105 m) (120 m)
Weld Output
Terminals
Y Turn off power before 10 − 60% 60 − 100%
connecting to weld out- Welding
Duty Duty 10 − 100% Duty Cycle
put terminals. Amperes
Cycle Cycle
Y Do not use worn, dam-
aged, undersized, or
poorly spliced cables.
100 4 (20) 4 (20) 4 (20) 3 (30) 2 (35) 1 (50) 1/0 (60) 1/0 (60)
150 3 (30) 3 (30) 2 (35) 1 (50) 1/0 (60) 2/0 (70) 3/0 (95) 3/0 (95)
200 3 (30) 2 (35) 1 (50) 1/0 (60) 2/0 (70) 3/0 (95) 4/0 (120) 4/0 (120)
2 ea. 2/0 2 ea. 3/0 2 ea. 4/0 3 ea. 3/0 3 ea. 4/0 3 ea. 4/0
600 3/0 (95) 4/0 (120)
(2x70) (2x95) (2x120) (3x95) (3x120) (3x120)
* This chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
( ) = mm2 for metric use S-0007-F−
***For distances longer than those shown in this guide, call a factory applications representative at 920-735-4505.
OM-2254 Page 18
5-5. Remote 14 Receptacle Information
M CC/CV select
2 3
Ref. 803 879-B
OM-2254 Page 19
‘
OM-2254 Page 20
SECTION 6 − OPERATION
ELECTRODE HOT
ARC CONTROL
6 5 7
OM-2254 Page 21
6-2. Meter Functions
NOTE The meters display the actual weld output values for approximately three seconds
after the arc is broken.
NOTE The Stick and CC modes provide the Adaptive Hot Start™ feature, which
automatically increases the output amperage at the start of a weld should the start
require it. This eliminates electrode sticking at arc start.
V-Sense Feeder MIG (GMAW) With Voltage Sensing Wire Feeder Electrode Hot
OM-2254 Page 22
6-4. Lift-Arc Trigger Hold TIG
1 TIG Electrode
2 Workpiece
. Procedure requires:
control
Start sequence:
1 2
• Touch tungsten electrode to
workpiece at weld start point.
• Momentarily depress output
switch.
• Slowly lift electrode. An arc will
1−2 form when electrode is lifted.
“Touch” Seconds
• To stop welding, momentarily
depress output switch and out-
put will shut off.
Note: If output switch is momen-
tarily depressed and tungsten is
not touching workpiece:
Do not touch tungsten to work.
Output will shut off in 3 seconds.
Start sequence over.
OM-2254 Page 23
SECTION 7 − MAINTENANCE & TROUBLESHOOTING
3 Months
Replace Repair Or
Damaged Or Replace Replace Cracked
Unreadable Cracked Torch Body
Labels Cables
Repair Or Replace
Cracked Cables
And Cords
Clean
And
Tighten Weld
Connections
6 Months
OM-2254 Page 24
7-3. Voltmeter/Ammeter Help Displays
V A V A
1 4
7-4. Troubleshooting
Trouble Remedy
No weld output; unit completely inop- Place line disconnect switch in On position (see Section 5-2).
erative.
Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 5-2).
No weld output; meter display On. Input voltage outside acceptable range of variation (see Sections 5-2, 5-3).
Unit overheated. Allow unit to cool with fan On (see Section 4-3).
Erratic or improper weld output. Use proper size and type of weld cable (see Section 5-4).
No 115 volts ac output at duplex recep- Reset circuit breaker CB1 (see Section 5-6).
tacle or Remote 14 receptacle.
No 24 volts ac output at Remote 14 re- Reset circuit breaker CB2 (see Section 5-6).
ceptacle.
OM-2254 Page 25
SECTION 8 − ELECTRICAL DIAGRAM
OM-2254 Page 26
219 484-C
OM-2254 Page 27
24
14 32 33
30 31
OM-2254 Page 28
77 78 84
25
8 85 29
11 15 28
6 12 16 23
26 35
5
19
13
9 20
4 34
27
17 38 37
10 18
3 39
40 79 36
74
22 82
75
80 83
21 41
58 57
42
43
84 81
63 44 45
64
51
1 56 MOD 2
2 47
50
65 MOD 1
66 52 49 17
62 53
73
54
55
68
70
71
72
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS.
OM-2254 Page 29
Item Dia. Part
No. Mkgs. No. Description Quantity
. . . 37 . . . . . . . . . . . . . . . 182 445 . . Nut, Conduit 1.000 Npt Pld 1.730 Od X .200 Thk . . . . . . . . . . . . . . . . . . . 1
. . . 38 . . . . . . T2 . . . . . . 211 968 . . XFMR, Control Toroidal 665 Vac Pri 1536 Va 60 Hz . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . 212 947 . . . . Plate, Mtg Toroid XFMR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 39 . . . . . . L2 . . . . . . 218 018 . . Inductor, Pre-Regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 40 . . . . . . . . . . . . . . . 218 566 . . Gasket, Inductor Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 41 . . . . . CT1 . . . . . 196 231 . . XMFR, Current Sensing 200/1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 42 . . . . . C15 . . . . . 196 143 . . Capacitor, Polyp Met Film 16. Uf 400 Vac 10% . . . . . . . . . . . . . . . . . . . . . 1
. . . 43 . . . . . . . . . . . . . . . 219 472 . . Bracket, Mtg Capacitor Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 44 . . . . . RT2 . . . . . 199 798 . . Thermistor, Ntc 30k Ohm @ 25 Deg C 18in Lead . . . . . . . . . . . . . . . . . . . 1
. . . 45 . . . . . PC2 . . . . . 225 442 . . Circuit Card Assy, Interconnect W/Label & Clips (Includes) . . . . . . . . . . 1
. . . 46 . . . . . . . . . . . . . . . 219 335 . . . . Label, Warning Electric Shock Can Kill Ce Wordless . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . 223 343 . . . . Clip, Wire Stdf .40−.50 Bndl .156Hole .031−.078thk . . . . . . . . . . . . . . 2
. . . . . . . . . . PLG13 . . . . 130 203 . . Housing Plug+Pins (Service Kit) RC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG14 . . . . 201 665 . . Housing Plug+Pins (Service Kit) RC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG15 . . . . 115 092 . . Housing Plug+Pins (Service Kit) RC3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG20 . . . . 115 093 . . Housing Plug+Pins (Service Kit) RC6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 47 . . . . . . . . . . . . . . . 153 403 . . Bushing, Snap-In Nyl .750 Id X 1.000 Mtg Hole Cent . . . . . . . . . . . . . . . . 3
. . . 48 . . . . . RM1 . . . . . 205 751 . . Module, Power Resistor W/Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 49 . . . . . . . . . . . . . . . 217 625 . . Kit, Input/Pre-Regulator And Inverter Module (Includes) . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MOD 1, SKiip 83 HEC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MOD 2, SKiip 83 EC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 50 . . . . . . . . . . . . . . . 212 206 . . Windtunnel, Rh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 51 . . . . . . . . . . . . . . . 196 330 . . Heat Sink, Power Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 52 . . . . . . . . . . . . . . +175 132 . . Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 53 . . . . . . . . . . . . . . . 229 325 . . Foot, Mtg Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . 54 . . . . . . . . . . . . . . . 176 736 . . Screw, Mtg Foot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . 55 . . . . . . . . . . . . . . . 212 073 . . Label, Warning Exploding Parts Can CE Wordless . . . . . . . . . . . . . . . . . . 1
. . . 56 . . . . . . . . . . . . . . . 212 074 . . Bus Bar, Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 57 . . . . . HD1 . . . . . 182 918 . . Transducer, Current 400a Module Supply V +/− 15V . . . . . . . . . . . . . . . . 1
. . . 58 . . . . . PC3 . . . . . 219 524 . . Circuit Card Assy, Front Panel & Display W/Program . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG18 . . . . 131 204 . . Housing Plug+Pins (Service Kit) RC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . RC50 . . . . 210 233 . . Rcpt, W/Pins (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG21 . . . . 212 088 . . Plug, W/Leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . RC21 . . . . 167 640 . . Housing Plug+Pins (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 59 . . . . . . S1 . . . . . 128 756 . . Switch, Tgl 3pst 40a 600vac Scr Term Wide Tgl . . . . . . . . . . . . . . . . . . . . 1
. . . 60 . . . . . . . . . . . . . . . 176 226 . . Insulator, Switch Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 61 . . . . . FM1 . . . . . 196 313 . . Fan, Muffin 115v 50/60hz 3000 Rpm 6.378 Mtg Holes . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG16 . . . . 131 054 . . Housing Plug+Pins (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . RC16 . . . . 135 635 . . Housing Plug+Pins (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 62 . . . . . . . . . . . . . . . 208 967 . . Rcpt Assy, Tw Lk Insul Fem (Dinse Type) 50/70 Series (Includes) . . . . 2
. . . . . . . . . . . . . . . . . . . . . 208 968 . . . . Rcpt, Tw Lk Insul W/O-Ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . 185 712 . . . . Insulator, Bulkhead Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . 185 713 . . . . Insulator, Bulkhead Rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . 185 714 . . . . Washer, Tooth 22mmid X 31.5mmod 1.310-1mmt Intern . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . 185 717 . . . . Nut, M20-1.5 1.00Hex .19h Brs Locking . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . 185 718 . . . . O-Ring, 0.989 Id X 0.070 H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . 186 228 . . . . O-Ring, 0.739 Id X 0.070 H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 63 . . . . . . . . . . . . . . . 212 070 . . Panel, Front Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 64 . . . . C5,6,7 . . . . 233 668 . . Capacitor Assy, W/Plug & Leads (Voltage Feedback) . . . . . . . . . . . . . . . 1
. . . 65 . . . . . . . . . . . . . . . 216 112 . . Fastener, Panel Receptacle Quick Access . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 66 . . . . . . . . . . . . . . . 219 341 . . Nameplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 67 . . . . . . . . . . . . . . . 212 948 . . Nameplate, Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 68 . . . . . . . . . . . . . . . 219 342 . . Nameplate, Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 69 . . . . . . . . . . . . . . . 174 991 . . Knob, Pointer 1.250 Dia X .250 Id W/Spring Clip−.21 . . . . . . . . . . . . . . . 2
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS.
OM-2254 Page 30
Item Dia. Part
No. Mkgs. No. Description Quantity
... 70 . . . . . . . . . . . . . . . 174 992 . . Knob, Pointer .840 Dia X .250 Id W/Spring Clip−.21 . . . . . . . . . . . . . . . . 1
... 71 . . . . . . . . . . . . . . . 218 041 . . Door, W/Quick Access Ball Fasteners . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
... 72 . . . . . . . . . . . . . . . 175 138 . . Box, Louver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
... 73 . . . . . . . . . . . . . . . . . . . . . . . . . . Label (Order by Model and Serial Number) . . . . . . . . . . . . . . . . . . . . . . . . 1
... 74 . . . . . . . . . . . . . . +212 207 . . Windtunnel, Lh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
... 75 . . . . . . . . . . . . . . . 211 503 . . Insulator, Heat Sink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
... 76 . . . . . . . . . . . . . . . Deleted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
... 77 . . . . . C8 . . . . . 219 191 . . Capacitor, Polyp Film .001 Uf 2000v W/Terms . . . . . . . . . . . . . . . . . . . . . 1
... 78 . . . . . . L6 . . . . . . 131 447 . . Core, Toroidal 1.332 Id X 1.932 Od X .625 Thk . . . . . . . . . . . . . . . . . . . . . 1
... 79 . . . . L5,L7 . . . . 199 122 . . Core, Toroidal .750 Id X 1.450 Od X .544 Thk . . . . . . . . . . . . . . . . . . . . . . 2
... 80 . . . . . . . . . . . . . . . 083 147 . . Grommet, Scr No 8/10 Panel Hole .312 Sq .500 High . . . . . . . . . . . . . . . 2
... 81 . . . . . . . . . . . . . . . 219 471 . . Bracket, Mtg Filter Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
... 82 . . . . . . . . . . . . . . . 219 473 . . Bracket, Mtg CE Filter Ground Plane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
... 83 . . . . . PC4 . . . . . 219 377 . . Circuit Card Assy, Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
... 84 . . . . . . . . . . . . . . . 207 152 . . Nut, 010−32 U−Nut Multi−Thread . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
... 85 . . . . . . . . . . . . . . . 227 746 . . Gasket, Inductor Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS.
OM-2254 Page 31
Notes
Start Your Professional 400 Trade Square East, Troy, Ohio 45373
Over 80,000 trained
Welding Career Now! 1-800-332-9448 www.welding.org since 1930!
Effective January 1, 2007
(Equipment with a serial number preface of “LH” or newer)
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
Warranty Questions? guarantees or warranties expressed or implied.
LIMITED WARRANTY − Subject to the terms and conditions * Induction Heating Coils and Blankets, Cables, and
Call below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants to Non-Electronic Controls
1-800-4-A-MILLER its original retail purchaser that new Miller equipment sold after
the effective date of this limited warranty is free of defects in
* APT & SAF Model Plasma Cutting Torches
for your local material and workmanship at the time it is shipped by Miller. THIS * Remote Controls
Miller distributor. WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE
* Accessory (Kits)
WARRANTIES OF MERCHANTABILITY AND FITNESS. * Replacement Parts (No labor)
Within the warranty periods listed below, Miller will repair or * Spoolmate Spoolguns
Your distributor also gives replace any warranted parts or components that fail due to such * Canvas Covers
you ... defects in material or workmanship. Miller must be notified in
writing within thirty (30) days of such defect or failure, at which Miller’s True Blue® Limited Warranty shall not apply to:
Service time Miller will provide instructions on the warranty claim 1. Consumable components; such as contact tips,
You always get the fast, procedures to be followed. cutting nozzles, contactors, brushes, slip rings, relays
reliable response you Miller shall honor warranty claims on warranted equipment listed or parts that fail due to normal wear. (Exception:
need. Most replacement below in the event of such a failure within the warranty time brushes, slip rings, and relays are covered on Bobcat,
parts can be in your periods. All warranty time periods start on the delivery date of the Trailblazer, and Legend models.)
hands in 24 hours. equipment to the original end-user purchaser, and not to exceed 2. Items furnished by Miller, but manufactured by others, such
one year after the equipment is shipped to a North American as engines or trade accessories. These items are covered
Support distributor or eighteen months after the equipment is shipped to by the manufacturer’s warranty, if any.
Need fast answers to the an International distributor.
tough welding questions? 3. Equipment that has been modified by any party other than
1. 5 Years Parts — 3 Years Labor Miller, or equipment that has been improperly installed,
Contact your distributor.
The expertise of the * Original main power rectifiers improperly operated or misused based upon industry
standards, or equipment which has not had reasonable and
distributor and Miller is 2. 3 Years — Parts and Labor
necessary maintenance, or equipment which has been
there to help you, every * Transformer/Rectifier Power Sources used for operation outside of the specifications for the
step of the way. * Plasma Arc Cutting Power Sources equipment.
* Process Controllers MILLER PRODUCTS ARE INTENDED FOR PURCHASE AND
* Semi-Automatic and Automatic Wire Feeders USE BY COMMERCIAL/INDUSTRIAL USERS AND PERSONS
TRAINED AND EXPERIENCED IN THE USE AND
* Inverter Power Sources (Unless Otherwise Stated) MAINTENANCE OF WELDING EQUIPMENT.
* Water Coolant Systems (Integrated)
In the event of a warranty claim covered by this warranty, the
* Intellitig exclusive remedies shall be, at Miller’s option: (1) repair; or (2)
* Engine Driven Welding Generators replacement; or, where authorized in writing by Miller in
(NOTE: Engines are warranted separately by the appropriate cases, (3) the reasonable cost of repair or
engine manufacturer.) replacement at an authorized Miller service station; or (4)
payment of or credit for the purchase price (less reasonable
3. 1 Year — Parts and Labor Unless Specified depreciation based upon actual use) upon return of the goods at
* Motor Driven Guns (w/exception of Spoolmate customer’s risk and expense. Miller’s option of repair or
Spoolguns) replacement will be F.O.B., Factory at Appleton, Wisconsin, or
F.O.B. at a Miller authorized service facility as determined by
* Positioners and Controllers Miller. Therefore no compensation or reimbursement for
* Automatic Motion Devices transportation costs of any kind will be allowed.
* RFCS Foot Controls TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
* Induction Heating Power Sources, Coolers, and PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
Electronic REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR
Controls/Recorders DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF
* Water Coolant Systems (Non-Integrated)
PROFIT), WHETHER BASED ON CONTRACT, TORT OR ANY
* Flowgauge and Flowmeter Regulators (No Labor) OTHER LEGAL THEORY.
* HF Units ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND
* Grids ANY IMPLIED WARRANTY, GUARANTY OR
* Spot Welders REPRESENTATION AS TO PERFORMANCE, AND ANY
REMEDY FOR BREACH OF CONTRACT TORT OR ANY
* Load Banks OTHER LEGAL THEORY WHICH, BUT FOR THIS
* Arc Stud Power Sources & Arc Stud Guns PROVISION, MIGHT ARISE BY IMPLICATION, OPERATION
* Racks OF LAW, CUSTOM OF TRADE OR COURSE OF DEALING,
INCLUDING ANY IMPLIED WARRANTY OF
* Running Gear/Trailers MERCHANTABILITY OR FITNESS FOR PARTICULAR
* Plasma Cutting Torches (except APT & SAF PURPOSE, WITH RESPECT TO ANY AND ALL EQUIPMENT
Models) FURNISHED BY MILLER IS EXCLUDED AND DISCLAIMED
* Field Options BY MILLER.
(NOTE: Field options are covered under True Blue® Some states in the U.S.A. do not allow limitations of how long an
for the remaining warranty period of the product they implied warranty lasts, or the exclusion of incidental, indirect,
are installed in, or for a minimum of one year — special or consequential damages, so the above limitation or
whichever is greater.) exclusion may not apply to you. This warranty provides specific
* Bernard-Branded Mig Guns (No Labor) legal rights, and other rights may be available, but may vary from
state to state.
* Weldcraft-Branded TIG Torches (No Labor)
In Canada, legislation in some provinces provides for certain
* Subarc Wire Drive Assemblies
additional warranties or remedies other than as stated herein,
4. 6 Months — Batteries and to the extent that they may not be waived, the limitations and
exclusions set out above may not apply. This Limited Warranty
5. 90 Days — Parts provides specific legal rights, and other rights may be available,
* MIG Guns/TIG Torches and Subarc (SAW) Guns but may vary from province to province.
miller_warr 2007−01
Owner’s Record
Please complete and retain with your personal records.
Distributor
Address
City
State Zip
For Service
Contact a DISTRIBUTOR or SERVICE AGENCY near you.
Contact the Delivering Carrier to: File a claim for loss or damage during
shipment.
For assistance in filing or settling claims, contact
your distributor and/or equipment manufacturer’s
Transportation Department.