You are on page 1of 2

BRAVIAR DE CALCUL HIDRAULIC ---- INSTALATIE DE SPRINKLE

1 2 3 4 5 6 7
Tronson Nr. SK Qsk L De H lin L x H lin
l/s m tol Pa/m Pa
1.1 1 1.33 3 1'' 4000 12000
1.2 2 2.66 1.5 11/4'' 3500 5250
a-b 4 5.32 3 11/2'' 7000 21000
b-c 8 10.64 3 2'' 7000 21000
c-d 12 15.96 3 21/2'' 5000 15000
d-e 16 21.28 3 3'' 3750 11250
e-f 20 26.6 3 4'' 1300 3900
f-g 24 31.92 3 4'' 1800 5400
g-h 28 37.24 3 4'' 2750 8250
h-GP 30 39.9 37.5 4'' 3000 112500
ACS

Hnec total pompare = Hnec + Hgeo = 658660 + 4000 = 662660 Pa = 6,70bar

Qnec total pompare = 39,90 l/s = 144mc/h


LIC ---- INSTALATIE DE SPRINKLERE

8 9 10 11
H tot = 1,2 x (L x H lin) S(L x H lin) Hu H nec
Pa Pa Pa Pa
14400 14400 100000 114400
6300 20700 100000 120700
25200 45900 100000 145900
25200 71100 100000 171100
18000 89100 100000 189100
13500 102600 100000 202600
4680 107280 100000 207280
6480 113760 100000 213760
9900 123660 100000 223660
135000 258660 100000 358660
300000 558660 100000 658660

= 662660 Pa = 6,70bar