Professional Documents
Culture Documents
Asme b31g Calculation Eml 4
Asme b31g Calculation Eml 4
Evaluation: UNACCEPTABLE
A= 2.0391
Pd (kPa) = 7530.52 Design Pressure
F= 0.72 Class Factor
T= 1 Temperature Factor
P (kPa) = 7530.52 The greater of the established MAOP or Pd
P'B31G (kPa) = 7391.01 The safe maximum pressure for the corroded area.
Factor of Safety = 0.98
Evaluation: ACCEPTABLE
2.0 Calculation of the Remaining Strength of Corroded Pipe
2.1 Case 2 - Modified B31G Criterion - 0.85dL Area
Evaluation: ACCEPTABLE