You are on page 1of 7

Residential

Heat Recovery
Units
ENERGY CLASS

Meets Energy class A+ in a cold


climate (Nordic region). When
configured for on-demand control,
the unit meets energy class A in a
temperate climate. Ecodesign
Directive 1253/2014.

AIR TREATMENT
MiniMASTER » HEAT RECOVERY UNIT (RDKS)

MINIMASTER

PRODUCT DATA FLEXIBLE, ENERGY EFFICIENT AND


• Thermal efficiency up to 83 %.
• Supply and extract air flow
EASY TO SERVICE VENTILATION UNIT
20–65 l/s
The MiniMASTER (RDKS) heat recovery unit is used as part of a system located in a kitchen or utility
• Recommended for residential room in residential buildings or small business premises. It is easy to install and very easy to service.
floor spaces up to 130 m2 The unit that has a supply air and extract air flow of between 20 and 65 l/s can serve residential
• Filter up to Class F7 floor spaces of up to about 130 m2.
• High-efficiency EC motors
The MiniMASTER has an integrated control unit and can also be equipped with automatic moisture
• Individually adjustable fans control and/or the potential for control via CO2 sensors. The ISYteq Touch 3.5 control panel is a real
• No drainage required benefit to your comfort. When located in a kitchen the unit is combined with a cooker hood. The unit
• Easy to install is equipped with a rotary heat exchanger with a very high thermal efficiency and speed control which
results in low energy consumption and accurate control of heating.
• Easy to service
• In the summer the rotor is The MiniMASTER has efficient filters and can be provided with an electric reheater. It can
automatically exercised T OF also be supplemented with an electric preheater in cold areas. In the summer the rotor
MiniMASTER IS PAR

HomeEDITION
every 48 hours. motor in the MiniMASTER is automatically exercised every 48 hours.

by FLÄKTGROUP
PRODUCT CODES
FLOW DIAGRAM FOR the MiniMASTER
MiniMASTER RDKS-a-b-c-d-e-f-g
Heat recovery unit
65 with rotary heat exchanger
a Connection
0 20 40 60 80 100 120 140 l/s
380 1 = outdoor air right, supply air right
32 2 = outdoor air left, supply air left
3 = outdoor air right, supply air right, white RAL 9003
4 = outdoor air left, supply air left, white RAL 9003
Connection (female) A B C D b Electric heater
Diameter 125 100 100 125 0 = without
600
Supply air Extract air1) Outdoor air1) Exhaust air 1 = only postheater
2 = postheater and preheater
1)
Enlarged to Ø 125 as soon as space permits.
c Moisture control
0 = without
380 1 = with
380
32 d Filter Supply air/Extract air
32
595 2 = (M5) ISO Coarse 85% bag filter/
(M5) ISO Coarse 85% bag filter
240 203 e Air quality control
115 70
0 = without
600 6 = CO2
83
78

600
183

188
B A
f Ethernet connection
265
285

D C 0 = without
5 = with
595 g Generation
Weight 40 kg
1
RDKR-1
595 Uteluft höger, tilluft höger
595
ACCESSORIES
240 203
240 203
203 240 Front cover RDKZ-15-b-0-ddd-1
115 70
115 70 70 115 (For installation between upper cabinets)
b Material
83
78
183

188
83

B A
78
83
78

3 = white
265

188

183
183

188

B A A
285

B
265
265

285
285

D C 4 = stainless steel
D C C D
5 = black
595 d Height in mm
595 595
060 = 600
RDKR-1
RDKS-1RDKR-1 RDKS-2 RDKR-2
Uteluft höger, tilluft höger 070 = 700
Uteluft
Outdoor höger,
air right, tilluftair
supply höger
right OutdoorUteluft
air left,vänster,
supplytilluft vänster
air left 080 = 800
203 240 090 = 900
203 240
70 115 100 = 1000
70 115
Installation kit for front cover RDKZ-18-1
83

78
188

183
83

A B
78

ACCESSORIES
265
188

183

A (For mounting of front cover in front of unit)


285

B
265
285

C D
C D
Suspension hooks for front cover RDKZ-16-1
ISYteq Touch 3.5 control panel................................................................................RDKZ-41-3
595
(For mounting of front cover directly on unit)
595
ISYteq Basic control panel..........................................................................................RDKZ-41-1 Extension unit towards ceiling (kit) RDKZ-17-b-c-d
RDKR-2
Filter (G3) ISO Coarse flat filter.............................................................................RDKG-99-14
RDKR-2 Uteluft vänster, tilluft vänster (Can only be used with RDKZ-16 suspension hooks)
Uteluft vänster, tilluft vänster
Filter (M5) ISO Coarse 85% bag filter................................................................ RDKG-99-15 b Material
Filter (F7) ISO ePM1 50% bag filter..................................................................... RDKG-99-16 3 = white
Electric heater for retrofitting.............................................................................. RDKR-99-03 4 = stainless steel
(can operate both as a preheater and a postheater) 5 = black
c Height in mm
Cooker hood for RDKS-1-b-c-d-e-f-1...........................................................CPDJ-b-cc-d-1-f
3 = 300
Cooker hood for RDKS-2-b-c-d-e-f-1.................................................................CPDJ-b-cc-d-2-f 4 = 400
FG_DC_9738GB_MiniMaster_SL_20190208_R2 © Copyright 2019 FläktGroup

Cooker hood for RDKS-1-b-c-d-e-f-1..........................................................CPTJ-a-bb-c-1-e d Generation


Cooker hood for RDKS-2-b-c-d-e-f-1................................................................ CPTJ-a-bb-c-2-e 1
Combi hood.............................................................................................................. RDKZ-26-000 Extension cable for control panel RDKZ-43-b-cc-d
Air inlet........................................................................................................................BSDB-20-012 b Variant
Ventilation hood......................................................................................................... CBAE-12-111 1 = 6-pole flat cable
Duct insulation ø 100............................................................................................. RDKZ-45-010 cc Length
Duct insulation ø 125..............................................................................................RDKZ-45-012 02 = 2 m
10 = 10 m
Silencer..............................................................................................................BDER-70-012-100
25 = 25 m
Moisture control............................................................................................................. RDKZ-51-1 d Generation
Ethernet connection....................................................................................................RDKZ-53-5 1

Distributors
You can find your nearest FläktGroup distributor at www.flaktgroup.com
ENERGY CLASS

Meets Energy class A+ in a cold


climate (Nordic region). When
configured for on-demand control,
the unit meets energy class A in a
temperate climate. Ecodesign
Directive 1253/2014.

AIR TREATMENT
VillaMASTER » HEAT RECOVERY UNIT (RDAF)

VILLAMASTER

PRODUCT DATA VENTILATION UNIT IN THREE SIZES


• Thermal efficiency up to 86%
• Supply and extract air flow
FOR ATTIC INSTALLATION
15–250 l/s
The VillaMASTER heat recovery unit is available in three sizes. The unit range is designed to be
• High-efficiency EC motors energy-efficient, with low SFPv values and the potential for preheating and reheating. In the summer
• Individually adjustable fans the rotor motor in the VillaMASTER is automatically exercised every 48 hours. The units are primarily
intended for detached houses and small business premises, and for installation in cold spaces such
• No drainage required
as attics. The three sizes have the following capacities:
• Easy to install
• Easy to service Mini 15–100 l/s for spaces up to 200 m2
• In the summer the rotor is Midi 20–125 l/s for spaces up to 270 m2
automatically exercised Maxi 40–250 l/s for spaces up to 500 m2
every 48 hours.
The unit has a rotary heat exchanger with stepless speed control, which results in very
precise temperature control. There is an add-on function available to limit moisture
VillaMASTER IS PAR
T OF recovery. The VillaMASTER units are fitted with the FläktGroup ISYteq Mini control
HomeEDITION system, complemented by the ISYteq Touch 3.5 control panel.
by FLÄKTGROUP
PRODUCT CODES
FLOW DIAGRAM FOR THE VillaMASTER
Heat recovery unit
Mini 100
VillaMASTER (RDAF) -a-b-c-d-e-f-g
Midi 125 with rotary heat exchanger
a Size
Maxi 250
1 = Mini
0 20 40 60 80 100 120 140 160 180 200 220 240 260 l/s 2 = Midi
3 = Maxi
b Electric heater
0 = without
1 = electric reheater
2 = electric preheater and reheater
Mini = 1000 W + 1000 W
Midi = 1000 W + 1000 W
Maxi = 2100 W + 1000 W
c Moisture control
0 = without
1 = with
d Supply air/extract air filters
2 = F7 compact/M5 compact
e Air quality control
0 = without
6 = CO2
f Ethernet connection
0 = without
5 = with
g Generation
2
Weight MINI 57 kg MIDI 67 kg MAXI 109 kg

Dimensions L B H H1 A C ØD E F G J
Mini 950 540 475 442 150 240 160 190 100 38 10
Cable to the control panel
Midi 1000 580 510 480 155 270 200 207 100 37 10
Maxi 1200 750 685 652 198 355 250 247 195 43 10 RDKZ-43-b-cc-d
b Variant
1 = 6-pin flat cable
ACCESSORIES cc Length
02 = 2 m
Control panel ISYteq Touch 3.5 (required to calibrate the fans).................... RDKZ-41-3 10 = 10 m
Filter set Mini F7/M5 (1 + 1).....................................................................................RDAZ-21-1 25 = 25 m
FG_DC_9740GB_VillaMaster_SL_20180925_R1 © Copyright 2018 FläktGroup

Filter set Midi F7/M5 (1 + 1).........................................................................................RDAZ-12 d Generation


Filter set Maxi F7/M5 (1 + 1)..................................................................................RDAZ-21-3
1
Combi hood Mini.........................................................................................................RDAZ-22-1
Combi hood Midi..........................................................................................................ABRZ-01-1
Combi hood Maxi........................................................................................................ABRZ-01-2
Silencer Mini................................................................................................ BDER-30-016-090
Silencer Mini................................................................................................BDER-30-020-090
Silencer Mini................................................................................................BDER-30-025-090
Moisture control (for retrofitting)..............................................................................RDKZ-51-1
Ethernet connection (for retrofitting)..................................................................... RDKZ-53-5

Distributors
You can find your nearest FläktGroup distributor at www.flaktgroup.com
ENERGY CLASS

Meets Energy class A+ in a cold


climate (Nordic region). When
configured for on-demand control,
the unit meets energy class B in a
temperate climate. Ecodesign
Directive 1253/2014.

AIR TREATMENT
HouseMASTER » HEAT RECOVERY UNIT (RDAS)

HOUSEMASTER

PRODUCT DATA ENERGY EFFICIENT VENTILATION UNIT


• Thermal efficiency up to 83 %.
• Supply and extract air flow
FOR COLD AND WARM SPACES
25–135 l/s
The HouseMASTER unit is primarily intended for domestic use and small premises and can be
• Recommended for residential installed in warm and cold spaces. All of its connections are upward and it can be wall-mounted,
floor spaces up to 280 m2 floor standing or laid horizontally on the floor with the cover upwards. The HouseMASTER has an
• High-efficiency EC motors air flow range of 25–135 l/s for floor spaces of up to 280 m2.
• Individually adjustable fans
The unit is equipped with high efficiency EC motors and has a rotary heat exchanger with a
• No drainage required continuously variable speed control, which results in very precise temperature control. There is an
• Easy to install add-on function available to limit moisture recovery. The HouseMASTER is fitted with the FläktGroup
• Easy to service ISYteq Mini control system complemented by the ISYteq Touch 3.5 control panel.

• In the summer the rotor is In the summer the rotor motor in the HouseMASTER is automatically exercised every
automatically exercised 48 hours. The unit is easy to install and very easy to service.
every 48 hours.
PART OF
HouseMASTER IS

HomeEDITION
by FLÄKTGROUP
PRODUCT CODES
FLOW DIAGRAM FOR the HouseMASTER
Heat recovery unit
HouseMASTER (RDAS) -a-b-c-d-e-f-g
135 with rotary heat exchanger
0 20 40 60 80 100 120 140 l/s a Dimensions
1
b Battery
0 = without
Connection A B C D
Diameter 200 1601) 200 1601)
1 = electric reheater, 1000 W

Supply air Extract air Outdoor air Exhaust air 2 = electric reheater + electric preheater
(2 x 1000 W)
1)
Enlarged to Ø 200 as soon as space permits
c Moisture control
0 = without
550
20+30+30 (Ø8) 1 = with
d Supply air/extract air filters
45 50
2 = supply air M5 compact/extract air
G4 compact
e Air quality control
0 = without
950
6 = CO2
f Ethernet connection
0 = without
5 = with
13 g Generation
424 424
13 1
506 580

140 55 55
190
Weight 68 kg Cable to the control panel
125 140
RDKZ-43-b-cc-d
235 235 b Variant
1 = 6-pin flat cable
cc Length
02 = 2 m
10 = 10 m
15 = 25 m
ACCESSORIES FG_DC_9739GB_HouseMaster_SL_20180925_R1 © Copyright 2018 FläktGroup

d Generation
Control panel ISYteq Touch 3.5 (required to calibrate the fans).................... RDKZ-41-3 1
Filter set M5/G4 (2 + 2)................................................................................................ RDAZ-10
Combi hood...................................................................................................................ABRZ-01-1
Silencer......................................................................................................... BDER-30-020-090
Moisture control (for retrofitting)..............................................................................RDKZ-51-1
Ethernet connection (for retrofitting)..................................................................... RDKZ-53-5

Distributors
You can find your nearest FläktGroup distributor at www.flaktgroup.com

You might also like