Professional Documents
Culture Documents
Brosura Recuperatoare de Caldura Rezidentiale
Brosura Recuperatoare de Caldura Rezidentiale
Heat Recovery
Units
ENERGY CLASS
AIR TREATMENT
MiniMASTER » HEAT RECOVERY UNIT (RDKS)
MINIMASTER
HomeEDITION
every 48 hours. motor in the MiniMASTER is automatically exercised every 48 hours.
by FLÄKTGROUP
PRODUCT CODES
FLOW DIAGRAM FOR the MiniMASTER
MiniMASTER RDKS-a-b-c-d-e-f-g
Heat recovery unit
65 with rotary heat exchanger
a Connection
0 20 40 60 80 100 120 140 l/s
380 1 = outdoor air right, supply air right
32 2 = outdoor air left, supply air left
3 = outdoor air right, supply air right, white RAL 9003
4 = outdoor air left, supply air left, white RAL 9003
Connection (female) A B C D b Electric heater
Diameter 125 100 100 125 0 = without
600
Supply air Extract air1) Outdoor air1) Exhaust air 1 = only postheater
2 = postheater and preheater
1)
Enlarged to Ø 125 as soon as space permits.
c Moisture control
0 = without
380 1 = with
380
32 d Filter Supply air/Extract air
32
595 2 = (M5) ISO Coarse 85% bag filter/
(M5) ISO Coarse 85% bag filter
240 203 e Air quality control
115 70
0 = without
600 6 = CO2
83
78
600
183
188
B A
f Ethernet connection
265
285
D C 0 = without
5 = with
595 g Generation
Weight 40 kg
1
RDKR-1
595 Uteluft höger, tilluft höger
595
ACCESSORIES
240 203
240 203
203 240 Front cover RDKZ-15-b-0-ddd-1
115 70
115 70 70 115 (For installation between upper cabinets)
b Material
83
78
183
188
83
B A
78
83
78
3 = white
265
188
183
183
188
B A A
285
B
265
265
285
285
D C 4 = stainless steel
D C C D
5 = black
595 d Height in mm
595 595
060 = 600
RDKR-1
RDKS-1RDKR-1 RDKS-2 RDKR-2
Uteluft höger, tilluft höger 070 = 700
Uteluft
Outdoor höger,
air right, tilluftair
supply höger
right OutdoorUteluft
air left,vänster,
supplytilluft vänster
air left 080 = 800
203 240 090 = 900
203 240
70 115 100 = 1000
70 115
Installation kit for front cover RDKZ-18-1
83
78
188
183
83
A B
78
ACCESSORIES
265
188
183
B
265
285
C D
C D
Suspension hooks for front cover RDKZ-16-1
ISYteq Touch 3.5 control panel................................................................................RDKZ-41-3
595
(For mounting of front cover directly on unit)
595
ISYteq Basic control panel..........................................................................................RDKZ-41-1 Extension unit towards ceiling (kit) RDKZ-17-b-c-d
RDKR-2
Filter (G3) ISO Coarse flat filter.............................................................................RDKG-99-14
RDKR-2 Uteluft vänster, tilluft vänster (Can only be used with RDKZ-16 suspension hooks)
Uteluft vänster, tilluft vänster
Filter (M5) ISO Coarse 85% bag filter................................................................ RDKG-99-15 b Material
Filter (F7) ISO ePM1 50% bag filter..................................................................... RDKG-99-16 3 = white
Electric heater for retrofitting.............................................................................. RDKR-99-03 4 = stainless steel
(can operate both as a preheater and a postheater) 5 = black
c Height in mm
Cooker hood for RDKS-1-b-c-d-e-f-1...........................................................CPDJ-b-cc-d-1-f
3 = 300
Cooker hood for RDKS-2-b-c-d-e-f-1.................................................................CPDJ-b-cc-d-2-f 4 = 400
FG_DC_9738GB_MiniMaster_SL_20190208_R2 © Copyright 2019 FläktGroup
Distributors
You can find your nearest FläktGroup distributor at www.flaktgroup.com
ENERGY CLASS
AIR TREATMENT
VillaMASTER » HEAT RECOVERY UNIT (RDAF)
VILLAMASTER
Dimensions L B H H1 A C ØD E F G J
Mini 950 540 475 442 150 240 160 190 100 38 10
Cable to the control panel
Midi 1000 580 510 480 155 270 200 207 100 37 10
Maxi 1200 750 685 652 198 355 250 247 195 43 10 RDKZ-43-b-cc-d
b Variant
1 = 6-pin flat cable
ACCESSORIES cc Length
02 = 2 m
Control panel ISYteq Touch 3.5 (required to calibrate the fans).................... RDKZ-41-3 10 = 10 m
Filter set Mini F7/M5 (1 + 1).....................................................................................RDAZ-21-1 25 = 25 m
FG_DC_9740GB_VillaMaster_SL_20180925_R1 © Copyright 2018 FläktGroup
Distributors
You can find your nearest FläktGroup distributor at www.flaktgroup.com
ENERGY CLASS
AIR TREATMENT
HouseMASTER » HEAT RECOVERY UNIT (RDAS)
HOUSEMASTER
• In the summer the rotor is In the summer the rotor motor in the HouseMASTER is automatically exercised every
automatically exercised 48 hours. The unit is easy to install and very easy to service.
every 48 hours.
PART OF
HouseMASTER IS
HomeEDITION
by FLÄKTGROUP
PRODUCT CODES
FLOW DIAGRAM FOR the HouseMASTER
Heat recovery unit
HouseMASTER (RDAS) -a-b-c-d-e-f-g
135 with rotary heat exchanger
0 20 40 60 80 100 120 140 l/s a Dimensions
1
b Battery
0 = without
Connection A B C D
Diameter 200 1601) 200 1601)
1 = electric reheater, 1000 W
Supply air Extract air Outdoor air Exhaust air 2 = electric reheater + electric preheater
(2 x 1000 W)
1)
Enlarged to Ø 200 as soon as space permits
c Moisture control
0 = without
550
20+30+30 (Ø8) 1 = with
d Supply air/extract air filters
45 50
2 = supply air M5 compact/extract air
G4 compact
e Air quality control
0 = without
950
6 = CO2
f Ethernet connection
0 = without
5 = with
13 g Generation
424 424
13 1
506 580
140 55 55
190
Weight 68 kg Cable to the control panel
125 140
RDKZ-43-b-cc-d
235 235 b Variant
1 = 6-pin flat cable
cc Length
02 = 2 m
10 = 10 m
15 = 25 m
ACCESSORIES FG_DC_9739GB_HouseMaster_SL_20180925_R1 © Copyright 2018 FläktGroup
d Generation
Control panel ISYteq Touch 3.5 (required to calibrate the fans).................... RDKZ-41-3 1
Filter set M5/G4 (2 + 2)................................................................................................ RDAZ-10
Combi hood...................................................................................................................ABRZ-01-1
Silencer......................................................................................................... BDER-30-020-090
Moisture control (for retrofitting)..............................................................................RDKZ-51-1
Ethernet connection (for retrofitting)..................................................................... RDKZ-53-5
Distributors
You can find your nearest FläktGroup distributor at www.flaktgroup.com