You are on page 1of 45
Me lnstaliation & Operation anual Portalie and inground 110 & 2200 Spas and Gas Packs | 2 CALIFORNIA ACRYLIC INDUSTRIES INC 1462 Bh Ses Pom Carin 1756 4) S237 INDEX GENERAL INFORMATION PAGE Safety Instructions rte — 12 Safety Rules oe CLINE va Glossary of Terms nn 45 Set Up and Delivery Guidlines nnn cceaesernen(a) OPERATING INSTRUCTIONS. Basic Information 7 Genera Pre-Opeaing insions & Bp Pring 8 Filler Maintenance ... SL 9 ‘Time Ciock 10 Winterizing & Draining Spa i Spa Light 2 Rotary Switch Coniol Panis. 13 Supra Operation aes 14 California Classic Operation ee 18 INSTALLATIONS, Pre-Pianning Stops for Inground Installation sso 18 Gas Pak and Add-a-Pak Installations a... ar Plumbing = 18419 Inground Spa Light 20 Inground instalation and Bock Reauiremens 21 Installation Techniques .. 2 QUICK CONTROL PANEL GUIDE Econo Spa and Eliminator Series Panes .. smi 23 Supra Panels 24 Gal Classic Pancis 25 “Tropical Waterfall Panels 28 Swim Spa and Bullet Spa Pancis 27 ELECTRICAL SCHEMATICS Electical Schematics .. 28-38 TROUBLE SHOOTING Trouble Shooting 30.01 IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be ‘allowed, Including the following 1, READ AND FOLLOW” ALL INSTRUCTIONS. 2. DANGER — To reduce the Hck of Ijury, do not permit Guudion to use ia proguc nise hey are das superset 2. MARI SK old, owing, Eagan muse Serco to povnt wsauhotsad aces by enon. To ave [teionteenure hat ehigran cannot use @ spa or het UD tales oy ave spared ata nes. 4, Uni aachmant cord: A leila cord of wator resistant ala wih grounding enauctr end an atachment pa. {To ond shat enon eens 0b naar than 18 16, (For cord end plan canned units) Do not bury co 6. (Forcrd and plug connate unts) WARNING — To adice thet ola shock rplee damaged co rede. 1. (ora nis) DANGER — To Radyo atk of inary 1 Ferson, ont remove sucion fing. To rei the ex oF Bi AA wala iv apa or hot ib sou never exca0d 40°O ow) Water Temperatures betoen 36° (10°F) and 07S {iow} av consaored sn holy oss. Laver wal {tnpatares ae tconsrended fr enered use (ceeding 5 mins efor young enon TO ADJUSY WATER FEMPERATURE, ROTATE MIDDLE DIAL ON TOP SIDE CONTROL. PANEL FOLLOWING TEMPERATURES ihocaTons. B._Snee excessive wae omparatues havea tiph potent {sua el eamage dang tn eaty meta of rea Frog or posisy pepo women sou pe orl Wb Mater tenparetres 6 S80 (007 Blo ering asp et tb, he fa war vi should moose mperaue ah an acer theron ance the tengeratrerelaling Gevies may vay 3 1, The use of seo pa orhat tub use mey feed fo unconscious possi fering Porson aullaing tom obey or wah ara stony of hat daeaze low of igh ood pressure, creltory sytem Protome, or doles should cout a pylon belore using Sain “rowstse whe enor medieston ma act he rosa, end cel 6. Prong MMERSION in hot walor may induce hyperthermia. lng exposure may reat in nausen, Sazinec or Tanng ‘Gteave'aearonate tr i ava spa the shower, cok ‘tnan, yous, tur or ancthor bia ay 8. (reo end plug connected wns on A pressure wre constr is prow on ha srtaco tho carol box ise te ‘a fe ot ho oper connestone of banding wa btwean thi point and eny metal equipment, metal anctosures ct ‘eto edlperent, meal waa lp of cond win va fet timo spa (er net tu) ae noaded to comply with loc ‘oqurenenta The bondng wie must be a east a No. 8 ANG fel copper ie 9. (For permanent ead ute on) A goen eo teint (or me eonnector mated “GF, or Sromding Ie provisos ‘Wihin'tha contol tox. To reduce the fk of sacral shock, “nnd hs tema er connector to tha round trina 9 our eecfel sonics o supiy pana wits conus geen ‘sted coppar wre connaorequvlos sto tho Seat ‘conductors coping ie equip, tut no emer than No.12 ‘AWG (dm In aden, 6 second wo connotes provided fer boning tical ground pats, T raueo Mo fk of wectre ‘Shook tha connoctr shor bo bondod wth a No.6 (Be) oppor wo ta any matt Laddre, aor pips, of oer Maal ‘ain oot (82) ot ta 40, (For cord and plug connact ype ony Tis equipment provided wen aground fault eat etorpia (a lect), Bitore eth use of your ep frat ub ft ho pug eared tothe power, pus the tel buten, Aad ght shoud appr. ‘Push the rose buton Tho rod fight should dsappeas tthe roe 9 round este shook copia unt th source of He bresidown Has boon Wotiod ana cect, 11, (For floor recessed hot tubs and epas), Install to pert bees or senting rm above oF bw fot. 12. (For unt) sal to prove caine of comparment for etc compenais 1, (For assemblies witha lowers) nstal in accordance with the dag oheep tn water ou of lst aucreant (Tab {companad win Sgram and ifamatn fr meurng Pelt foun farsa, and uso of mises chock vos), 44, For sgseblas), Intal wih nonmetal pba connections {old and at lonet § foot (1'82m) from metal enclosure of ‘ese osc wal of us 18. (For all epas) DANGER — RISK OF ELECTRIC SHOCK, Iria aout eat (tse) from al ma sistas (Apa be ineiaied win oat of taal aufacas rv aosoroanes tho Nationa Elecical Code, ANGINFPA 70-1088, and each neta surface te permanoniy connected by a No. 8 ANG (Gam) copper eansuctratahod the wre certo onthe {ermal bx ats provided forbs rp) 16. (For unite with gas eaters thet aro Intonded en fr ‘uidgor use) WARNING = Do nt Ital ndars, This uit mpl ager Neaer that requies proper veniaion eng is Ira fo cut doo usa oly. 17, DANGER — RISK OF ELECTRICAL SHOCK. Do not permit ‘ay ec! appinees such a8 ft, lopone, rad, ot {sivilon within fet of tho spa ht i 1. SAVE THESE INSTRUCTIONS IMPORTANT SAFI ETY INSTRUCTIONS (continued) When instaing and using this electrical equipment, basi safety precautions should always be followed, Including the following 48, A ovrdtault-droutinteruptor must bo proved is (Rds ftson to contd an underwter ging ture. The vcs von the load sido of the groundstauit-orult- FaRtUpter sha not accupy condu, Boxes, oF enclosures rey cher conduetors urlese fe adonsl ndctors Sieg Ptected bya round tautoret-nteruper. 49, Tho electica supply for this product must node a ‘Ghat rated sich or Grcul breaker to open alungownded siren conductors to eomply wih Section 422-20 ofthe Higlohat Electrical Code, ANSIINFPA 70-1987. 7 i eEcrnting moans must bo ready accessible 1 tho apart but nada fast 5 feet (1.5m) fom tub water », SAVE THESE INSTRUCTIONS THERAPEUTIC POOLS (SPAS) SAFETY RULES “Therapeutic pools or *spas" are usualy piped and controlled so that very warn water or hot water often wih rere Re forced at igh velocty tao & eantned area of @ swimming poo or to a small separate pool Be econ fy of te war andthe heal furnish crtan hydrodherapeutc benefits, These pools aro excellent aot ne rer Boel conditioning and for ats and rheumatic problems, but ean be hazardous to the user Each parsons body and cicuatlon system has lerent tolerances and responds aiferenty to warmhot Fach ere orF amount of time that safe, therapeutic uso of spas or hot tubs wil vary, Most people in dood Immersion. THe a omporalure about 102°F Wo be salstying and itn in water at this temperature to 20- health tao Jen of slccnelic beverages and certain medications may afect the way your body/s system reacts Ao in weterfmot water inersion. Consull your piysiclan for recommendations, “The Consutner Product Safety Commission has recommended the fllow/ing "Safety Fuules for Hot Tubs": |A. Spa or hot tub water temperature should never exceed 104°F (40°C). A temperature of 102°F (99°C) is ore red sate fora healtiy adul, Special caulon is suggested for young children. 1B. Drinking of alcoholic boverages betore or during spa or hot tub use can cause drowsiness which cou lead to unconsciousness and subsequenlly result in downing. ‘©. Pregnant women beware! Scoking ln water above 102°F (99°0) can cause fatal damage during the fst Poet or pregency (resuting in the birth ofa brain damaged or deformed child), Pregnant women should stick tothe T00°F (38°C) maximum rue, 1B. Before entering the spa or hot tub, users should check the water temperature with an accurate Thasmsomotor, some spa or ot tub thetmastats may be of in regulation water temperatures by as much 25 AF 22°C) IE. Persons with medical histories of heart disease, circulatory problems should obtain their physician's advice before using the spas or hot tubs. , Persons taking medications which induce drowsiness such tranquilizers, antihistamine or eniicoagulant, ‘Should not use spas or hot tubs. {@. Never touch or comin contact with any electrical accessory when in your spa of when your body is wet Hi Prior 10 performing any service to the Spa Pack, turn off ALL power to the aystem af the main power source breaker. 1. Never turn equipment pack on unless spa i filed with water to the centr ofthe skimmer. Read all instructions very caretully and completely before instalation ofthe spa may votd the warranty, I you Paes Say questions thet are not explained inthis manuel, consult your spa dealer, Consult your local buldng epaniment for any questions that may need, Ie. plumbing, electrical, ete. Some areas may require & ‘swimming pool or building permit WARNING Do Not Exceed 104° is Warranty AIR BLOWER, AIR LOOP AIR VENTURI BLEEDER VALVE CHECK VALVE CONTROL PANEL GLOSSARY OF TERMS -The Ait blower supplies arto the air channel caps Inthe lower portion ofthe sre eating the hydro massage action. The blower works Independently off the pump, iter, and healer. ‘A back-up system forthe check valve. Mounted genecally on the lip of the spa and regulated the functions ofthe iets. Located at the 1p of the'fiter, Used for releasing air out of iter. “To prevent water back low to blower. tounted generally on the fp ofthe spa and controls the functions of the spa. DOOR INTERLOCK — Mounted in the doors ofthe spa skirting FILTER ‘The fiter cleans the spa by passing the water through a fitering syster The tours and impurities are removed, Top loading means the fier i Pete ee on the top of the spa, generally by skimmer, in-ine fiters ar ‘under the eabinet near the equipment GATE VALVES -Thandled valves located at the inlets and outlets of the equipment. Use Coc ad the fiter, the gate valve blocks or opens the water line by th ‘equipment HEATER “The thermostatically controled heater ralses the tempereture of the water the desired degree. HOSE BIB Used in the draining of the spailooks like an outdoor faucet and fits standard garden hose. Jers: ‘A-HYDRO Cal Max-Flow Jets" produces a siaight, yet adjustable flow fora therapet massage. B-SwinL Cal Mavi-Suil Jets" provides a moving, cular therapeutic massage. @-WHIRLPOOL Provides on overall swing therapy slay, to what doctors and hosel Fsommead for treatment of sre or damaged muscles. D-AIR INJECTORS The muliple, smaller 9 holo “butane” Ino the ar channel which oe {inging, bubbling sensation type of therapy. E-VERTSSAGE The lage slotted Jot yhich offers a vertically moving massage uP and os ‘your back while you sit & enjoy. F=NECK BLASTER The dual[et, above water neck massage system with acjustable Power G- BULLET (Our smallest hydrotherapy jt GLOSSARY OF TERMS MAIN DRAIN During the operation of the equipment, the main drain works in ‘conjunction withthe skimmer to return wator tothe fiter along withthe, surface and bottom debris, keeping the spa sparking clean. NO FREEZE PROTECTION — Used for continuous heating of spa or in colder months to prevent pipes from freezing. Also maintains proper filrtion when spa is not being used, VALVE KNOB" Use to dver alr or water to various channels. | skimmer “This is the rectangular outlet at the water level. The skimmer moves surfaces debris to te filer. The water lovel inthe spa should be kept atthe center ofthe skimmer for optimum operation TIMER OPERATION ‘Allows you to set the fitering and heating tine ofthe sp. USE NO ACID, ( ‘Tri-Chlor or Algecide Solutions ~ They Ruin Acrylic Spas. SET-UP AND DELIVERY GUIDELINES [AND SET-UP OF YOUR NEW SPA ELECTRICAL REGUIREMENTS--ALL SELF-CONTAINED .SpAS-—110 VOLT OR 220 VOLT ELECTRIC HEATERS. ies an isolated (7 other appliances oi [GETTING READY FOR DELIVERY 4 Your 110 vot spa rea jghts on this cult t any time) 110 vol, 20 ‘amp circuit breaker. 1p circuit breaker 2: Depending one model your 220 vl spa wien 84, £9 8 60 amy ‘a Extension cords are not to be used in coruncon wih operation of the spa. Low volage damage could Faas which fs idk covered by warranty ‘a ryou have any doubls, have your elactical syst checked by'a qualiied electrician. SURFACE AND PAD REQUIREMENTS: “4. Your new portable spa must be paced on a ue Wn and level concrete pad. (we recommend yr ro aleatedacting methods require approval 2: your spas tobe placed near where sprinkers may Ni adjust or cap them to prevent rom fitting on ‘shit or spa equipment AEQUIREMENTS FOR DECKING, GATES AND BALCONIES: 4. Decking mut be constructed to Suppo 150 pounds pr Ae foot. ‘2. Gates must be seltlosing and setttocking (Calforia requirements). 1 Dalconig rust be constucad to cuenta andlor codes {epa toad requirements are 160 pounds ‘square foo), WARNING Do Not Exceed 104° Excessive ‘Temperature ‘Voids Warranty BASIC INFORMATION INTRODUCTION: ‘Congratulations onthe purchase of your new Cal Spa, Our purpose sto provide you witha warm and relaxing bath which ‘hoorporaes a soothing wator massage. In order to maximize the pleasure of your spa, you wl need fo understand how it works. ‘A spas workin the same general ashon, high-powered pump pushes water through th ots which can be very relaxing to soro muscles, Spas today have control ha lon te apa owner lo ranipulate the water ad ar ow. Al spas wi vary inegard tothe amount of contol, the 822 ofthe spa and the amount of options purchased wih Do nat be etal to push buttons and turn knobs. Your now Cal spa is bul wih quality mattis. and craftsmanship. tis ‘very har to han anyting by experimenting wih th conrls. In fat, iis he best way 1o gett knaw your sp “The following operating’ and mainlnance instructions are vory Important, and must be followed caretuly. th he proper care and maintenance, you Cal spa wll provide you wih years of satisfaction and performance ith a misimum of fo. ‘A. The pump and heater should be operated minimum of we hours per day for cleaning and heating (Refer to page 10 {or more Information on programming he time coc). 1B, The length ofime required to heat your spat the desited tomporature wil vary depending onthe heater size, season, ‘wale lempeature, wind velo, ee. Tetafera this Is something each owner must adjust to tel ting, We highly Teeommend using solar blanket andor vinyl hard cover to miirize heat loss and to protect your spa when nat in tse, Covers are avaliable rom your local Gal Spas dealer, ‘©. Operating the air blower should be lied to when the spa isin use. Continuous operation increases heat loss and i. AF Stars cosecea sohuam gaatusah tt " G. Screw, grounding 10-26 x 12° 20 INGROUND INSTALLATION ‘Water test spa above ground prior to placing in ground. Aso instal no decking around spa. ntl spa has operated for an ‘adequate amount of time o assure al partios that thee aa no leaks. "Mound 8" of wet sand in bottom of excavation for gpa to rest en Belor lowaring spa ino excavation, be sure that he frshed rim elevation Is estabshed in relation to ground level Crotty lower spa ino excavation centering on the mound of sand. With a downward force and slighty rotating back and | rt, work pa into measured level. Pack sand around main drain and under bottom of spa leaving na old, | __Set2x4 on imo spa ath lave then rotate 2 x 4 checking evel nal decons. Make sur that sand ising al voids | under botiom, ror obackfitng the reminder fil the foctwol area ofthe spa wih water to assis In even, During the backing, fi 1} ids under bottom. Bact n one foot incremens. After each lve, use a war hose o swt water n and around backl being caret nolo {od the excavation. This proces wil ensure that ll the sand Is formed around the sides ofthe gpa leaving no voids ator | | the water as eine though. Do not back sand round jet punting of he spa ut spa has been completly hooked || tothe enupment and nun to check for passbl es. | Beco se unoen ur Brox cmos 10 INGROUND SPA DECK REQUIREMENTS ‘A. Dockmust go under ip of spa uniformly for proper ip support. Lip snot to bear any welght frm spa, Dack Is only to stop lip rom flexing wen stepped or sat on 'B. Deck must nat be poured up against spa, since cement expands and contracts as temperatwe changes, Leave a gap ‘of 2 from shel or proper sbucture protection. Tr ‘e-owcemen 7 ll INSTALLATION TECHNIQUES LEFT: Excavation for partially above-ground spa wil RIGHT: Above ground spa require @ tench undor wall pend on how deep you want fo set In this example, footings for plumbing. Walls car be brick, conerte lock texeavaton i requlod forthe foctwel area ofthe gpa and or poured concate. fox concrtefoatngs for otainer wal Ona stoop hillside, retanor walls aro used on both the uphill and downhil sides ofthe spa ‘excavation. In some situations, this method may be easier than tying to love alge area ‘around the spa, Hilsde tub must havea retaining wall on up ‘do only. This insalaton roquies a minimum ‘of docking, Deck should have salty alin. Bld concreta form of 2x4 and 1x2 stakes as shown, Excavate 2 inches below bottom of forms an fl with clean sand. Lay a toot square ri of 1/2 inch reinforcing rods over leveled sand bed. Tie rods together with baling wire, Mix concrete and pou itn the form. Spread concrete evenly wih a sturdy steel rake, vel concrete witha sored bul form 1 x 4's as shown, Pull tho seread toward you wih a sideopsde zigzag motion ‘When concrete is leveled, smooth out with a large masons oat, Alow concrete to cure atleast one week before seting ub, 22 i QUICK CONTROL PANEL GUIDE " cal spas introduces the Econo-Line and Eliminator Series portable epas, where nury meets with affordable prices, These unit, ke all ther Cal Spa contol panals, hava been designod for the consumer's ease of ‘operation, These few basic steps wil guide you. ECONO-LINE wien toa te ‘tua the Spaion ELIMINATOR SERIES exes ed ‘ase comec, ALE nt wit gaat ERS "en oles, gE, Elk ae fae ee es Spakah “ ojuvenator Seat vitae coe ie 23 QUICK CONTROL PANEL GUIDE SUPRA SERIES ‘The Supra Spa control panel shown below is used on aur electic equipment packs only. These fow basic ‘explanations will guide you to complete contol, ‘Tis particular control pane! has three (9) large knobs. The left knab controls your ar functions. The center knob controls your temperature and the right knob controls your water functions. Spa ots ae Supetchagediaben Aelvats the Al Bower, | Thevaheietn ter Warn ror” Contols Diss Powerto the ‘hspostion Fail” water Temperatre Top'So Gort Paral | manors sin sale Semmes, Sct at sain ; oman OR iets i ‘The Supra control panel shown below is used on our gas equipment packs only, These few basie explanations will guide you. This particular control panel has three (8) large knobs. The loft knob controls your alr functions, The center knob controls your air ventul and the right knob controls your water functions, erase mec ‘woe ans Si sets wot aia ‘A-Channel oo a ‘Ni Vor forthe Totaatedinthe — sevstad wan vk inorbge “is poiion ‘wpe Jt Fiejovopier Seat “ls ngispostion RewonatorGeat Jae peta Aatateatno Acton Autos Aaivated ne jt in “rasiporhaged when Ar Blowor —‘AWarmar we Spaligs —‘thedete sho javensir Sat ‘vols in te poaton (cuts ar vlume'e 12) ‘whan aos in Wis pion 2a SALIFORNIA CLASSIC “The Classic Spa contol panel shown below is used on our elactic equipment packs only. These few basic explanations will guide you to complote contro ‘This particular control pane! has three (3) large knobs, The lat knob controls your air functions. The center knob controls your temperature and the right knob controls your water functions. | S QUICK CONTROL PANEL GUIDE | Spa ets ara ‘Supetchagoduhen Actes the Ae Blower, ip! Jt Rrmvaivo sin ener Warn cor Gents ‘shina when valve AeChame th gular Ay Water Temparatee ieintis postion Fjivonator sda Jets Achatsethe Avalos _ vets Pere ‘Actas hoot aesipachargodwhen Spalight” tedots Top Sde Conta Pare tho Raivnator Soa mn Tieton ue te pin {wih Water Cont Dete Vase to ‘ee th hil Jt ortho. Fojuvnaior Sat ‘The Classi¢ Spa control panel shown below Is used on our gas equipment packs only, These few basic | explanations wit ue youte complete contol || This particular control panel has two (2) large knobs, The left knob contrals your air functions. The right knob ‘controls your water functions, Spa Jats 0 _supeanagea nen ‘echo han valve ievane isin poston | Toma i Rejovnat’ oat ots ets pete Acta to tn i sparharged when AeBower ‘ede tho Revonater Seat postion va wav in tis peslon ‘Aelvates Supercharger ‘Aetvalesthe The Hest Pung avalos te wale, "hreugh a Jo petit” few gSng throug he heat goes | or tenor Sot tothe Water Conta Deter Vaveto i + Nee the Wniisol str the QUICK CONTROL PANEL GUIDE TROPICAL WATERFALL SPA 8'x10' ‘This Waterfall conto! pane! is used on our electric equipment packs only. These few basic explanations will put you in complote control | | petistea the ‘Therapy and Ste Wipal Jt is Reidvonatr Saat " scared whan vate Pobanatr Conta Sh” gchar ea isin his postion Water Femperaire —"hispasion Tnerton whom vo in hi poston ctiatos —_atvatde tho cos om Ar viarer * ‘whan vive sine postion a au Rejuvenate Soot dts ™ ett ste spercarged when ‘hee val shpetion TROPICAL WATERFALL SPA 12'x18' conta TpPoaton” Shaped Reant egret Sic eat Set ate coir Scag Brera TopPostonRojuentr Set was ‘Aicvenan Valve Edam Popten “Spats Esha fos ‘ows in io ‘wag tedeee © Ai Chane! cr aerator oat inecton QUICK CONTROL PANEL GUIDE SWIM SPA “The control panel.shown bolow.is used withthe Incredible Swim Spa, These few basic explanations will put you in complete control. 2 Wiay Valve ~ controls he power of 2 Way Valve ~ contols the power of ertets the power of ho Zann 2 speud mate pump, ino Zo fx St po on uporased = At ‘op actnalas te Rojuvenstof Sos, Model), poed” water pump. Chanel midd-ghsupereharges the Ielemecsteshetner Swi ies” Topas alfa ting to sk evn Sot too serps Blase, bttom activates Upper Swim Je Aetvats fespaed fojtsor Turon ods Tus on Sof Tumtan& of ‘o'Rejvenator Set iguppar undewalerSpatigts "Wepocdio Heated Arta srheaped wer Sn‘ ReGosnest "Air Channal BULLET SERIES SPA “The control panel shown below is for our new Bullet Series Spas, These few basic explanations wil put you in complete contro tens ne oe ‘Wea St iste Rejyvonatr Saat ‘emis raat ete ‘apo et poston aa Agelion johnei ae : gates = 27 220 VOLT ECONO U.R. PNEUMATIC SWITCH ELECTRIC/ SCHEMATIC OILVINSHOS TWOidLO313 HO.LUAS OLLWINN Nd "HN HAINHd LOA OFF so mae 220 VOLT PREMIER U.R. PNEUMATIC SWITCH ELECTRICAL SCHEMATIC OLLWWSHOS WWOIWLOATS "HN WHANS HOVd SVD s=== Agu ---- ame N33 (300 [G00—0990) at VUANS LION OF $229.10 \VednS INOA O22 122-9 usck 5 5 z 4 onanae tt | tt foo [ry wR (Hance Dear (355 * > amos * * SUPRA TOP SIDE CONTROL PANEL ELECTRICA) SCHEMATIC OLLVIWSHOS TWOIHLOST3 HOLIMS SILVINANd “8°N WANS 110A 027 PS3 DELUXE ELITE 220 VOLT ROTARY SWITCHES ~ LOW CONTROL VOLTAGE SSVIIOA TOHLNOD MOT SSHOLIMS ANVLOY LOA 022 SLITS VHdNS Sd CAL CLASSIC ELITE 220 VOLT ELECTRICAL SCHEMATIC OLLVINSHOS WOlwLOAT3S ——_§_|_<§_ ama LIOA 022 LATING DISSV19 TVD Tae | a7 CTC-221 110 Volt GAS PACKS UL. CTC-221 220 Volt UL. ig ne ba 4 JO creat i0v LINE: 2-110 Volt 60 HZ 20 Amp Circuits LOAD: 2-110 volt 6OHZ 16 Amp Circus § 66633654 450 ‘erc-221 220 LINE: 2 each 220 Volt 21 PH 4 Wire 20 Amp Circuit LOAD: 2 each 220 Volt ‘60 Hz 1 PH Ea 4 Wire 15 Amp Ciroult i I PROBABLE CAUSE #1 RECOMMENDED ACTION: PROBABLE CAUSE #2: RECOMMENDED ACTION: PROBABLE CAUSE #8: RECOMMENDED ACTION: PROBABLE CAUSE #6 RECOMMENDED ACTION: PROBABLE CAUSE #5: RECOMMENDED ACTION: PROBABLE CAUSE 46: TROUBLESHOOTING GUIDE ) NO HEAT OR HEAT TOO Low Breaker at house of. Roset breaker at house, Breaker can appear to be on & one pole can be ol. “Thermastat not on Max. Temp, ‘Turn thermostat all the way up. Thermostat (depending on model) will either be located on the control box or on the control panel. It you have a top mounted thermostat cable flow the cable from the top, dawn to the Control box, loosen the set screw, turn thermostat knob clockwise unth it ‘slops, then reconnect. This wil ensure both are set on maximum seting, Heater not plugged in Check heater plug, making sure its pushed all the way in receptacle, Inadequate water flow du to diy fier, Clean fier catridge(s). (See page 9) ‘Hightimit ‘popped out. eset Red Button on contol box. Pump not primed, RECOMMENDED ACTION: Refer to pump priming. (See page 8). PROBABLE CAUSE #7: Improper line voltage, RECOMMENDED ACTION: Have Licensed Electrician chock the ine voltage. PROBABLE CAUSE #8 Spa cover lt of RECOMMENDED ACTION: Heat spa vith cover on, NO HEAT OR HEAT TOO LOW~ GAS UNITS PROBABLE CAUSE #1: Temperature knab set too low. RECOMMENDED ACTION: Loosen set screw at temperature Knob ang increase as desire, relignien set sorew ‘SPA LIGHT WON'T COME ON PROBABLE CAUSE #1: Light bulb burnt out RECOMMENDED ACTION: Replace bulb. (See page 12). PROBABLE CAUSE #2: Dirty connection RECOMMENDED ACTION: Chock to sea I there Is anything covering the connection on the housing ‘that holds the ght bub PROBABLE CAUSE #3: Light plug natin al the way. RECOMMENDED ACTION: Check plug, making sure i's pushed in all the way into receptacle 39 TROUBLESHOOTING GUIDE IETS WON'T COME ON PROBABLE CAUSE #1: Oporation of spa with doors open. RECOMMENDED ACTION: Doors must be closed all the way because ofthe door interlock safety system PROBABLE CAUSE #2: Pump plug notin all the way. RECOMMENDED ACTION: Check pump plug, making sure ifs pushed in all he vay in receptacle, PROBABLE CAUSE #3: Pump not primed, RECOMMENDED ACTION: Reter to purnp priming, (Soe page 8) PROBABLE CAUSE #4: Air tubing disconnected, RECOMMENDED ACTION: Check airline tubing to $00 If disconnected at ether ond ofthe tubes. PROBABLE CAUSES: Gato Valves closed. RECOMMENDED ACTION: Check to see i both Gate Valves are inthe up positions. (See page 14 or 1). LOW WATER FLOW PROBABLE CAUSE #1: Dirty filter. RECOMMENDED ACTION: Remove fiter cartridge and clean, PROBABLE CAUSE #2: Closed valvos or blocked lines. RECOMMENDED ACTION: Open all valves (2) in system. PROBABLE CAUSE #3: Low voltage or incorrect voltage. RECOMMENDED ACTION: Wiring to be corrected by licensed electrician, ‘PROBABLE CAUSE #1: Loose connection. RECOMMENDED ACTION: Hand tighten all quick disconnects and ftings. Check gaskets and O-rings. PROBABLE CAUSE #1: No power to motor RECOMMENDED ACTION: Chock power ovitchoo & creuit broakors. Chock motor wiring et torminale PROBABLE CAUSE #2: Pump not plugged in. RECOMMENDED ACTION: Check plug, making sure it's plugged in all the way into receptacle. PROBABLE CAUSE #9: Pump jammed from foreign matter in impeller. RECOMMENDED ACTION: Call Cal Spas for recommended action PROBABLE CAUSE #4: Purnp ran dy. RECOMMENDED ACTION: Call Cal Spas for recommended action, MOTOR RUNS HOT ‘PROBABLE CAUSE #1: Poor ventilation RECOMMENDED ACTION: Do not tightly cover oF enclose pump motor. PROBABLE CAUSE #2: Restricted suction line. RECOMMENDED ACTION: Make sure all valves are open. NOTE: These motors wil feo! hot to the touch. Ths‘ normal. The internal overioad protector il turn the ‘motor off if there isan overload or high temperature problem, Sooty | TROUBLESHOOTING GUIDE WILL NOT. PROBABLE CAUSE #1: No water in pump. RECOMMENDED ACTION: Mako sure walter level in spa is midway in skimmer mouth. PROBABLE CAUSE #2: Airlock, RECOMMENDED ACTION: Bleed off ar at Ar Relief Valve. PROBABLE CAUSE #2: Closed valves or blocked lines, RECOMMENDED ACTION: Open al valves (2) n systom, BLOW! ‘PROBABLE CAUSE #1; Blower plug not plugged in RECOMMENDED ACTION: Check plug, making sue IIs plugged all the way into recoptacto. PROBABLE CAUSE #2: Air tubing disconnect. RECOMMENDED ACTION: Check ale tubing at lthor ond to soo its disconnectd. 1ES ON WHE! I PROBABLE CAUSE #1: Linos crossed. RECOMMENDED ACTION: Reverse airlines atthe control box. AIR BLOWER WILL NOT OPERATE PROBABLE CAUSE #1: Improper seting of air button control switches. RECOMMENDED ACTION: Air button sequencer ison air postion, PROBABLE CAUSE #2: Blower not plugged in, RECOMMENDED ACTION: Piug blower in PROBABLE CAUSE #3: Air bing disconnected. RECOMMENDED ACTION: Check ar line tubing o See fit is disconnected FHOBABLE CAUSE #1: Pressure bullds up in the alr tines. RECOMMENDED ACTION: Pressure builds up in the alr lines and you need to install a small air relict hole in the air tubing. Simply puncture ale lines with a hot safety pin in the air lines coming out of control box. ME ELVES PROBABLE CAUSE #1; Pressure builds up inthe airlines. RECOMMENDED ACTION: Pressure bulls up in the airlines and you need to install a smaller rliet hole in the air tubing. Simply puncture airlines with a hot safety pin in the air lines coming out of control Box. NOTE: Air lines require small relief holes to keep (AZ conraor sox jrossure from building in ai nes which could cause “ipment to stay on or come on by ise To corect nis, puncture ai ines with hot safely pin where : noted in diagram, Simple soutons to smal problams ann peur ad 2 this can and should be learned by owner, as this wil be considered a maintenance eal, and not @ Yarrany eal A tip charge could rest i the service = ‘epartment scaled out on this acount. ToAMBuTToN a Equipment Warranty Limited Warranty (OAL SPAS st), marrarts each ecole pups hos alos, a bowers are Colcol box again calc in ater and workmanship a prod ol one year on pats and 80 day on bor Ho Gate of xignal purchase. any component fas fo pr Wy normal uve ng tho wavtanly period the ar that prove be delete wl ier be rpaed x eplacad at Seller's epan Th if reared by the Sele to replace the whole produ si feed. Tha Sefer ws waa te epaceron or rep fot oti be vnespied porn ofthe orginal warrenty. Should eps como necessary crng the warany Dario retun he component, postage or Kah. prepa, oie Ses alr, EXCLUSIONS. Tis contrat doos not cover sonces rade nocascary 26a rei fra, tha vandal, acs of God, tceiontl damage, abuse, neglect (ait o lack of ouline recommended rainlsnance). Unauthorized ateratins, oF ary oer cause rgnaingeusio tho produ) covered, inuding fakes or nadaquacios in cuss war, gas, o elect’ supply. Alto elie tom coverage aa al pie texan theequpment pak nud bu not ted the lambing. IMPORTANT. CAL SPAS warantes is products agains dolactve mato and workrarcip, not against azure deo improper inealaon techniques, tte esponbly othe puchasero assure ha those Instaing hs equipment ar wel ned in coret an proper ian ocho, SERVICE ANDIOR REPAIR. Should your oqupment requ soroe folowing the waranty pei or ‘shou i eqite sence ardor repair frnan-warany fs, feta to hw lal, ight preps n \arlingseao te problem you ae expeincing wih your camponor. A reasonable charge wl be mad forlaber and atl, any ‘ALL LIABILITY FOR ANY INOIDENTAL OR CONSEQUENTIAL DAMAGES, TIME CHARGES OR ANY (CTHER LOSSES INCURRED IN CONNECTION WIIH THE PURCHASE, NSTALLATION, REPLACEMENT ‘OF FEPAIR OF THE SELLER'S PRODUCT IS DISCLAMED AND EXCLUDED HEREFROM ASSIGNMENT. This cones psonlo anothesle Deel o th egal purchase athe gna te purchase ana oxcopt ih be ooearinwitng a ala Aeye sete, he. sot spr Soma states dono alow tttons on how ong an ged waranty lasts, the exclusion orton of incidental er consaquental damages eo Ihe above lntaton or exclusion may not apply to you. Tn warranty gies you speci legal his, ard you may also have othe his whieh vary om tats a tae, HOMEOWNER-COMPLETE AND RETAIN FOR YOUR RECORDS FQUIPMENT MODEL # _ SERIAL # DATE OF PURCHASE BUILDERDEALER, HOMEOWNER'S NAME, ADDRESS __ omy _ STATE 20. TELEPHONE (=) DATE OF START UP _ The World's Largest ‘Spa Manufacturer = California Acrylic Industries, Inc. 1462 E. Ninth St., Pomona, CA 91766 Aemoneroutonn Jvc ess (714) 623-8781 a “fia a mn en Tk as LUMITED WARRANTY {hss sary wan to eof lt alr a vats tom dl of eva, TO THE OMUGIAL PURCHASER AND THE DhiGhi PURCHASER ONLY AT THE ORGNALST="OF DELVE WE (6) YEARG: Tha GPA SHELL and ha apa sol ni wri ail lcs in malate wkmanship win be eit prod fr eal 1 Clara est Fe pune cl es tt, lal apace wpa oat hal nan a al en i ha at © Hehe thon saat pasty torte sama sar inn ch match fn na abl reagent Pl ‘Sk. tama rsp Adlon, forte pono cl expe enn tate ape a apse excl salah yo het ‘Sane nom need scans on re punting tos tear Marcus ere eh apa ropa open, Sn ‘uch repaconert rrp shal eatumo a warty pry ei ie rt is ery the el prea. (NE (YEAR: th INTERIOR FHS se ped WB Spa Shy exp aon ele acy ned scooter an peu. Sal oqupan e waranted era dees rao re wokmanip iinet pao eat elector op cs. The Tory ea ‘cena and psoas Be evga eco an eer avin hep, uy naras shou aint at ae ‘Sm nah sant be pare to eaanytnsan sce he apace ste fs lene te epee to spas Hele ‘hen aha datamined ns dad shove Maule eaten Be io ec er epa aopen, any auch apesa ep ‘alsesume a waranty pa en orem Uno udetia wray fbe oaposie | Perigo ay al acne, cen, ime uta ings, Haake, a abtrg a0 ward ora pio ONE) | WoobotercproouoTs GAZEHOS wegen a be rch ey enon rman hd nr nm ao ery uo oar is rot sng wih a sy fs rig anon, Cal psn any ue 9 ay aay 0 ‘oan rath purchase gat. SHEA GIVES ABSOLUTELY NO ENTITLEMENT TO THe REPLACEMENT OF AY OTHER ITEM, UGH AG ACGESSOMIES, FINISH, OP EQUIPMENT NOR GOES Ie REPAIR OF THE SPa Fes, EXCEPT UNDER THE CRCAMSTANCES NHEE TH SPA FRISH 18 UNACPAIRABLE, IN WBC [BEM A ePUACEHENT SHELL SHALL ALSO BS PROVIDED AT THE REDUCED COST AS SPECIFIED ABOVE QUAN Calta Aco sts, re. ees waar oa fect nro workman ONE 0) yao fn 9 ye ‘Se IMPROPER VOLTAGE SUPPLY OR USE DF AV EXTENSION CORD Wi VOID WARAUWITY. REFER TO OANEH MANUAL OM ELECTRGAL {Ts WARRANTY DOES NOT APPLY ay dla ous apace mse, sods ree andl Expl of te caren oegigenc neh wi ine is warty re () tune adsl peas mei spa NO ACO ON ACO PROBUCTS WAY BE UGE ‘ui SPA aot etna pote yous tom octane intempo, eon Get seo naval ait ou ie | fame ara eopr ttt by Buyers we unr a pooray orange tan eal eon A= SPECIMED I YOUR OHNE MANUAL ‘yes Son JB Be NGTALLED ON A LEVEL SUNEAGE, Ie ROMTABLE, ON ADEQUATELY EACKELED WH SAND Ir INSTALLED NQROIND, Fo Slotor tse npc etn acne cross path etn ac, | aan e above epstiee pees, CALFOMIA ACRYLIC NOUSTINES, INC, sf pao eee ary Epeted poprovng dtc in ‘Scvanes wi above Waray pve; prea hwo, ha ste pacha be pate by Buje un tha poison te eve Strano, mance sa not one opr tw toque ep et acne a aya eh Cage by Buyer. yee Wsed ‘Sra diy be Dar fem who nee sh ha prac espa who sang mara ares EV THE EVENT THE GUYER SHOULD CE {iiBLe, FOR Ay REASON, To ExTHER OBTAIN SUCH SERVICE OR OBTAW SATISFACTORY SERVICE , Me OM GHE Ig eTAUCTED TO [CONTACT HIRUFACIURER SERVICE GEREN, CUSTOMER SERVICE DEPRRIMENT, LOCATED AT 1401 ENN SY, POMONA, A 61708, ‘TREPHONE: (14ers, (72 SPA6, WHICH WIL MMEOITELY TARE STEPS TO PROMOE ALL SERGE TO WHVGH BUYER MAY BE EXILED UNDER THs WARRANTY, A rponte oa osc e rpang tfc sper ep nh sab azure by te marter sito ros Pts) me Ga wp onsen non fle el neon et ‘Sng vaca, oe rata tt oud ited aon Srwmaueae who ach sect tro a ached or reed 3 ‘Ratan. wate er inproers ened by Bajo ae cil pine ror wre atl acer ob a eaton ha bo mecled {Stier oia dobar (pe was dave marta apn eet pe oun atasr case ba mec. [BUYER MUST NOTIFY marta cle, malrton, arco ppl apn een Naan by Buyer oot slg Ds ‘nett is egdvret Win TWENTY) dae soe ghng nice ood Dar Orleans aed igety prs many ae “ten erBvyes aed sot manchse opted haintora Manteca asa or autos my Dasa oath arn a Fran oss fr ny le ty conan ih ths ot Signa be be specie roasts artes tesa ght mae ange orEngrvenans nou peste wren hh inno peace aay purchase, Aver oti edn Cllr as hat tone hi acs sro eae he many poo The waranty pel oar et Ihemumbortr wot dasa he pate has bem ot a he tyes oes fe ware repre a cee ent ne waranty Soa fe wey ‘tree rl tects be nd The manly peel sie sent weal ropes or ben gerd Gon tae ead 1) ercastrcstoyrd te cnt he Sue, ot wary tepals ot ody hfe ane Bajr net to man dao ol he lho cl terete wine 6 aay ake twy te corpses sara ears rer ae, a aan bo ae, Bye may ean I occ ra ropes rnd ete, eet cn, auton semana care for wag. Tite earn ot ee {1_NARRANTY GIVES YOU SPECIFIC LEGAL FIGHTS, AND YOU MAY HAVE OTHEA FIGHTS VIG VARY FROM STATE TO STATE he Buse ash ie big any ston awe ogy teal apn enon os tc terse Ns warn [CAUFORN ACAYLIG NOUSTFES, NC. 1482 Nh Sol, Peron, CABY7EG(716) 52078

You might also like