You are on page 1of 1

ABB Automation Products

Maintenance Note DOCMNACS80009


Fan / ACS800-x1/x4/104, R2 and R2i, IP21
ABB Oy, Product Support 2410ML-05W-B60-EQ5
Department Date Author Checked / Approved Revision Page

TLC 09.12.2008 Kimmo Hirvonen Kari Rusanen A 1 (1)

6 Years Preventive Maintenance

FUNCTIONAL DESCRIPTION:
The AC drive is equipped with the cooling fan. Cooling air enters the drive through the
air inlets in the door. The direction of the airflow is upwards. The dissipation power of
the switchboard is about 2% of the rated power of the switchboard.
REASONS FOR THE CHANGE:
The manufacturers estimation for the operational time of the cooling fan (2410ML-
05W-B60-EQ5) is about 70 000 hours @ 40 degrees Celsius. The major problems are
caused by the failure of the bearings.

Figure 1: : An example of the cooling fan versus ambient temperature

THE RESULTING EFFECT:


Ageing of the electronic cards, the components and the connections results in:
1. Increased vibration due to the imbalance of the cooling fan (can last for several
months)
2. Increased temperature due to the stopped cooling fan (overheating in about 15
minutes).

WHERE USED:
ACS800-x1/x4 IP 21, R2 and R2i
ACS800-x1/x4-0001-2 to -0005-2 ACS800-x1/x4/104-0003-3 to ACS800-x1/x4/104-0004-5 to
-0009-3 -0011-5