Stepper Calibration

Insure that All Movement Commands are sent in Millimet


X Axis Calibration
G Code Command

Test Distance to Move 250.000 G0 X=250 (G Zero not the lett


Actual Distance Traveled 250.000
Discrepancy Multiplier 1.000 1.000 indicates no Discrepancy
Current Steps/MM 40.000
New Steps/MM 40.000 $100=40 Round to 3 decimal

Y Axis Calibration
G Code Command
Test Distance to Move 250.000 G0 X=250 (G "Zero" not the lett
Actual Distance Traveled 250.000
Discrepancy Multiplier 1.000 1.000 indicates no Discrepancy
Current Steps/MM 40.000
New Steps/MM 40.000 $101=40 Round to 3 decimal

Z Axis Calibration
G Code Command
Test Distance to Move 30.000 G0 X=30 (G "Zero" not the lett
Actual Distance Traveled 10.000
Discrepancy Multiplier 3.000 1.000 indicates no Discrepancy
Current Steps/MM 40.000
New Steps/MM 120.000 $102=120 Round to 3 decimal
tion
ds are sent in Millimeters
Unit Conversion Calculator
(G Zero not the letter O) Inches
Millimeters
000 indicates no Discrepancy
Millimeters
Round to 3 decimal places Inches

(G "Zero" not the letter "O")

000 indicates no Discrepancy

Round to 3 decimal places

(G "Zero" not the letter "O")

000 indicates no Discrepancy

Round to 3 decimal places


nversion Calculator
1
25.4

12.7
0.5