Product range ETR4 timing relays
Function Multi-functional
On-delayed
Off-delayed
Fleeting contact on energization
Fleeting contact on de-energization
Flashing, pulse initiating
On- and Off-delayed
Pulse forming
Pulse generating
AC-14
300 V Ie A 3
AC-15
300 V Ie A 3
Width mm 22.5
Technical data
General
Standards Standard IEC/EN 61812
VDE 0435
Lifespan, mechanical
AC operated Operations x 10
6 30
Ambient temperature
Enclosed °C - 25 - + 45
Half-sinusoidal shock, 20 ms g
Make contact g 4
Degree of protection
Terminals IP20
Weight kg 0.1
Terminal capacities mm
2
Solid mm
2 1 x (0.5 - 2.5)
2 x (0.5 - 1.5)
Making capacity
Breaking capacity
AC-14 Ie
AC--14
440 V Ie A 3
AC-15
DC-11
L/R max. 15 ms A
24 V Ie A 1.5
Pick-up AC VA 2
Sealing AC VA 2
Pick-up DC W 1.8
Sealing DC W 1.8
AC ms 50
DC ms 30
Air discharge kV 8
Contact discharge kV 6
10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat Meets the product standard's requirements.
and fire due to internal electric effects
10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements.
10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard's requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility.
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will
provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be
observed.
10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be
observed.
10.13 Mechanical function The device meets the requirements, provided the information in the instruction
leaflet (IL) is observed.
Electric engineering, automation, process control engineering / Low-voltage switch technology / Relay and socket / Timed relay (ecl@ss10.0.1-27-37-16-05 [AKF092013])
Function star-delta No
Nominal current A 3
Width mm 23
Height mm 83
Approvals
Product Standards IEC/EN 61812-1; IEC/EN 60947-5-1; UL 508; CSA-22.2 No. 14; CE marking
Characteristics
Flow diagram for timing functions
LED legend
11 On-delayed
12 Off-delayed
82 Pulse shaping
On-Off function