You are on page 1of 1

Lc

BEAM HEIGHT
L1 L2
B A D

LIST OF DRAWINGS

d
h
SHEET NO. SHEET TITLE

G F H
S-00 COVER SHEET

S-01 GENERAL NOTES


ZONE A ZONE B ZONE C ZONE B ZONE A

S-02 FLOOR FRAMING PLANS


NOTES:
1. SEE BEAM SCHEDULE FOR STIRRUP TYPE AND SPACING.
S-03 CONCRETE COLUMN SCHEDULE 2. ZONE A LENGTH SHALL BE TWICE THE BEAM HEIGHT, h.
3. THE FIRST STIRRUP IN ZONE A SHALL BE LOCATED 50.8mm MAXIMUM FROM THE FACE OF THE SUPPORT.
S-04 CONCRETE BEAM SCHEDULE (SEISMIC) (1 OF 2) 4. LAP SPLICES SHALL NOT BE LOCATED WITHIN THE BEAM/COLUMN JOINT, NOR WITHIN A DISTANCE OF 2H.
5. LAP SPLICES SHALL BE ENCLOSED BY HOOP STIRRUPS AT A MAXIMUM SPACING OF D/4 OR 101.6mm, WHICHEVER IS SMALLER.

S-05 CONCRETE BEAM SCHEDULE (SEISMIC) (2 OF 2)


Typical Concrete Beam Elevation 1S
S-06 CONCRETE COLUMN LAYOUT

Lc1 Lc2

BEAM HEIGHT BEAM HEIGHT


L1 L2 L1 L2
B A D C A B
d

d
h

h
G F H F F G
TYPICAL LAP TYPICAL LAP
(SEE NOTE 5) (SEE NOTE 5)

ZONE A ZONE B ZONE C ZONE B ZONE A ZONE A ZONE B ZONE C ZONE B ZONE A

NOTES:
1. SEE BEAM SCHEDULE FOR STIRRUP TYPE AND SPACING.
2. ZONE A LENGTH SHALL BE TWICE THE BEAM HEIGHT, h.
3. THE FIRST STIRRUP IN ZONE A SHALL BE LOCATED 50.8mm MAXIMUM FROM THE FACE OF THE SUPPORT.
4. LAP SPLICES SHALL NOT BE LOCATED WITHIN THE BEAM/COLUMN JOINT, NOR WITHIN A DISTANCE OF 2H.
5. LAP SPLICES SHALL BE ENCLOSED BY HOOP STIRRUPS AT A MAXIMUM SPACING OF D/4 OR 101.6mm, WHICHEVER IS SMALLER.

Typical Concrete Beam Elevation 2S

Lc1 Lc2 LcN

BEAM HEIGHT BEAM HEIGHT BEAM HEIGHT


L1 L2 L1 L2 L1 L2
B A D C D C A B

NO DESCRIPTION DATE
d

d
h

h
0 NEW DRAWING GENERATED 09-05-2021

Width Width
G F F H F F H F F G
TYPICAL LAP TYPICAL LAP TYPICAL LAP
(SEE NOTE 5) (SEE NOTE 5) (SEE NOTE 5)

ZONE A ZONE B ZONE C ZONE B ZONE A ZONE A ZONE B ZONE C ZONE B ZONE A ZONE A ZONE B ZONE C ZONE B ZONE A

Depth

Depth
NOTES:
1. SEE BEAM SCHEDULE FOR STIRRUP TYPE AND SPACING.
2. ZONE A LENGTH SHALL BE TWICE THE BEAM HEIGHT, h.
3. THE FIRST STIRRUP IN ZONE A SHALL BE LOCATED 50.8mm MAXIMUM FROM THE FACE OF THE SUPPORT.
4. LAP SPLICES SHALL NOT BE LOCATED WITHIN THE BEAM/COLUMN JOINT, NOR WITHIN A DISTANCE OF 2H.
5. LAP SPLICES SHALL BE ENCLOSED BY HOOP STIRRUPS AT A MAXIMUM SPACING OF D/4 OR 101.6mm, WHICHEVER IS SMALLER.

Typical Concrete Beam Elevation 3S


Beam Section-A Beam Section-B

DRAWING

Width

GENERAL NOTES - 1
Depth

STRUCTURE

ASSIGN 3
Beam Section-C

PROJECT

CLIENT

CONSULTANT

HEWLETT-PACKARD

PROJECT NUMBER

DATE

DESIGNED BY

CHECKED BY

S-01
SCALE