ON DIP

ON DIP
Press “enter” key more than
3 seconds into setup mode
WorkMode WorkMode
Configuration Basic Parameter
Press “enter” key more
Press “down” key than 1 seconds to make sure
to the next item
WorkMode
BackUp
Auto Loop Display WorkMode Button operation display
Input&Output Para

WorkMode Battery information WorkMode


(Lead acid)Vb:xx.xV BAT Charge_Etoday energy
(Lithium)Vb/Cb:xx.xVxxx%
Ec_d:xxxx.x KWh WorkMode
WorkMode
Battery power WorkMode Priority
BAT Charge_Etotal energy
Offline Pbat: (+/-)XXXX W Online Ec_a:xxxx.x KWh

WorkMode WorkMode WorkMode


EPS-R information GridR information BAT Discharge_Etoday energy
EPS_R:xxxV/xxHz Grid_R:xxxV/xxHz Ed_d:xxxx.x KWh

WorkMode
WorkMode
WorkMode WorkMode BAT Discharge_Etotal energy
EPS-S information GridS information Ed_a:xxxx.x KWh
EPS_S:xxxV/xxHz Grid_S:xxxV/xxHz Mode Change
Press up key
WorkMode WorkMode GridT WorkMode
EPS-T information AC output_Etoday energy
EPS_T:xxxV/xxHz Grid_T:xxxV/xxHz information Eac_d:xxxx.x KWh

Output AC Power
WorkMode WorkMode WorkMode
AC output_Etotal energy
EPS_R: xx.xkW
EPS-R output power
Po: xx.xkW Cycle Eac_a:xxxx.x KWh WorkMode
display 2
WorkMode WorkMode
times in 6 WorkMode
ExportLimit
EPS-S output power seconds System Time
EPS_S: xx.xkW Po: xx.xkVA 20XX/XX/XX/XX:XX

EPS-T output power WorkMode


WorkMode WorkMode Serial number
Load ratio SerNo:xxxxxxxxxx
EPS_T: xx.xkW Per_Load: %

Power to grid or to user


WorkMode
WorkMode WorkMode
To grid is - Machine model
Pm: (+/-)XXXXW Model:xxxxxxxxxx Default Set
To user is +

WorkMode
Firmware version
FW Version:xxxx

WorkMode
Auto Test
Press “enter” key more Press “enter” key more Press “down” If you need to enable AC charging
than 1 seconds to make sure than 1 seconds to make sure key to the next item If battery first is choosen
Choose “OK” to function, you need key password
WorkMode WorkMode WorkMode WorkMode WorkMode WorkMode the next item WorkMode WorkMode
Priority Opt: Load First Bat First: OK SC : _ _ _ _ AC CHG: Enable
Basic Parameter Language English
Bat First NO Disable
Press “down” Italian Grid First
key to the next item German WorkMode WorkMode
Time 00:00 – 00:00
WorkMode WorkMode Range from 100 to 550V,
Lead-acid LV 160V
100V and the accuracy is 1V WorkMode Range from 5% to 100%,
Stop SOC: 100% and the accuracy is 1%

WorkMode Range from 5% to 100%,


Only display when WorkMode WorkMode Range from 0 to 25A, and Power Rate: 100 % and the accuracy is 1%
battery type is lead-acid Lead-acid CC 20 A
25 the accuracy is 1A
WorkMode
Save :OK
NO
If Grid first is choosen Choose “OK” to
WorkMode WorkMode Range from 100 to 550V, the next item
WorkMode WorkMode WorkMode
Lead-acid CV 550V and the accuracy is 1V Grid First: OK 00:00 – 00:00
Time
NO
WorkMode Range from 5% to 100%,
Stop SOC: 5% and the accuracy is 1%
Press “down”
WorkMode WorkMode key to the next item
WorkMode Range from 5% to 100%,
System time xxD/xxM/xxxxY XX:XX and the accuracy is 1%
Power Rate: 100 %

WorkMode
Save :OK
NO

Press “enter” key more Press “enter” key more


than 1 seconds to make sure than 1 seconds to make sure
WorkMode WorkMode
BackUp Backup: Enable
Press “down” Disable
key to the next item
EPS setup
WorkMode
ACVolt: 230 V
240 Press “enter” key to Press “down” Press “enter” key to
208 make sure key to the next item make sure
WorkMode WorkMode WorkMode
WorkMode
Mode Change Battery Type Lithium
AC Freq: 50 Hz
Lead-acid
60
Press “enter” key more Press “enter” key to
than 1 seconds to make sure make sure
WorkMode WorkMode
ExportLimit ExportLimit: OFF
Press “down” ON
key to the next item

WorkMode Range from 00.0% to 100.0%,


PowerRate: 00.0% and the accuracy is 0.1%

WorkMode
Fail Safe: ON
OFF

Press “enter” key to Press “enter” key more


make sure than 3 seconds to make sure
WorkMode WorkMode
Default Set YES
WorkMode WorkMode 59.S2 Limit 59.S1 Limit
Auto Test YES ? Waiting to start 253.0V 3000ms
Press “enter”more than 3
seconds to enter
59.S2 Limit 59.S1 Testing
264.5 V 200ms 230.4 - xxxxV

59.S2 Testing 59.S1 Pass


230.8 V - xxx V 254.7V 3000ms

59.S2 Pass 27.S2 Limit


264.7 V 180ms 92.0V 200ms

27.S1 Limit 27.S2 Testing


195.5 V 400ms 230.4- xxxxV

59.S2 Testing 27.S2 Pass


230.8 V - xxx V 90.8V 180ms

59.S2 Pass 81>S1 Limit


194.7 V 380ms 50.5Hz 100ms

81>S2 Limit 81>S1 Testing


51.5Hz 100ms 50.01- xxxxHZ

81>S2 Testing 81>S1 Pass


50.01-xxxxHz 50.05Hz 80ms

81>S2 Pass 81<S1 Limit


51.52Hz 80ms 49.5Hz 100ms

81<S2 Limit 81<S1 Testing


47.50Hz 100ms 50.01- xxxxHZ

81<S2 Testing 81<S1 Pass


50.01-xxxxHz 49.5Hz 80ms

81<S2 Pass Auto Testing


47.49Hz 80ms Auto Test Passed