You are on page 1of 4

Phone: 316-744-7151

Kice Industries, Inc.


Fax: 316-744-7355
5500 Mill Heights Dr

Wichita, KS 67219
USA

Quote Number: 122254 Quote Page: 1 of 4

Quote To:
Date: 7/7/2021
Yan Bustamante
Induamerica
Carretera Panamericana Norte Km 775
Chiclayo LAMBAYEQUE
Peru

Phone: +51 074265476 x 121 Sales Person: Alex Kice


Fax: +51 074 26 52 66 Phone: 316-744-7151
Email: ybustamante@induamerica.com.pe Fax: 316-744-7355
alexkice@kice.com

Bellavista - New Project - Rice husk conveyor

07/07/2021-R6 updated per 07/07/2021 email. Please note: I am having to substitute a new model of blower for APU
due to available inventory.

DELIVERY= 9 weeks from receipt of order/down payment.

06/17/2021-R5 update per 06/15/2021 email and line schematic

Thank you for your recent inquiry requesting a quote for a Kice Positive Pressure Conveying System. We appreciate
your interest and offer the following system designed to convey 4.5 MTPH (165 lbs./min.) of rough rice husks 132
meters (427') horizontal, 12 meters (40') vertical, with 4 ea. 90 degree sand-t ells in a 6"OD line. Material to be dry, free
flowing, with a bulk density of 6 lbs./cu.ft.

The following tubing system, elbows and couplings are priced individually or by the foot, for estimating purposes and are
subject to final layout. We have estimated what may be required; additions and subtractions should be made to our
estimates

05/26/2021-R4 Update per specifications and InduAmerica supplied CAD drawing

05/13/2021-R3 Update per specifications + spare parts

03/03/2021-R2 Update per specifications.

10/08/2020-R1 67Q diverters to be 220v single phase and freight quote to Callao Port

09/28/2020
Ref. InduAmerica supplied CAD drawing
Dollars
Line Quantity Part Description
1 1 Air Power Unit M-D 5514 Air Power Unit
- M-D 5514 blower.
- IFS inlet filter/silencer.
- Chambered type outlet silencer.
- Check plate assembly with outlet to 6" OD.
- Pressure gauge.
- Pressure relief valve.
- Sanitary structural steel base and motor rails.
- 30 HP, 1750 RPM, 286T frame, class TEFC, 230/460/3/60 NEMA Premium efficient motor.
- NOTE: Standard TEFC motor with no environmental marking/T Code.
- V-belt drive with 1.5 to 2.0 service factor.

Print Date:7/7/2021 03:06 PM


Phone: 316-744-7151
Kice Industries, Inc.
Fax: 316-744-7355
5500 Mill Heights Dr

Wichita, KS 67219
USA

Quote Number: 122254 Quote Page: 2 of 4

- Totally enclosed sanitary belt guard.


- Product contact zones unpainted, all other surfaces painted Kice white; guards painted safety orange. Please specify
otherwise.

- Start-Up Lubrication Kit: Including Kice recommended food grade synthetic lubrication and accessories. Re-order part#
Blower Lube Kit 4.

For more information visit http://www.kice.com/Products.


Quantity Unit Price Net Price
1 EA 24,739.00 24,739.00 USD

Line Quantity Part Description


2 1 SHP20x15-II Type II Airlock Surge Hopper, 38" Dia.
- Stock inlet to customer specifications. __
- Stock outlet to mate 20x15x15 airlock.
- Sight Glass in hopper.
- Suction vent fitting to 4" OD with free air inlet and damper.
- Product contact zones unpainted, all other surfaces painted Kice white.
Quantity Unit Price Net Price
1 EA 2,208.00 2,208.00 USD

Line Quantity Part Description


3 1 AIRLOCK VJX 20x15x15 Airlock
- 15" square inlet and outlet with a displacement of 2.3 CFR at 100% full.
- Cast gray iron housing and endplates with plow type inlet.
- Patented replaceable outboard bearing cartridge - integrated bearing and PTFE shaft seal .
- Cast ductile iron eight-vaned, "open end" rotor.
- Driven by SM-CycloModel CNHM-6125-Y, 59:1 (30 RPM) ratio, gearmotor w/ integral 2 HP, 1725 RPM, TEFC, 230/460/3/60
premium efficient motor.
- NOTE: Standard TEFC motor with no environmental marking/T Code.
- Chain drive to 15 RPM.
- Fixed motor mount with adjustable idler sprocket.
- Fully enclosed sanitary guards.
- Meets NFPA 69 as passive isolation device.
- Support feet.
- Bolt-on rotor tips of A.R. steel.
- Fully machined clearances of 0.005" to 0.007".
- Bolt on trough type pan to 6" OD 11 ga. tubing.
- Chrome plated body and endplates all internal surfaces.
- Inlet shunt required per DWG.3-5743.
- Product contact zones unpainted, all other surfaces painted Kice white; guards painted safety orange. Please specify
otherwise.

For more information visit http://www.kice.com/Products


Quantity Unit Price Net Price
1 EA 16,448.00 16,448.00 USD

Print Date:7/7/2021 03:06 PM


Phone: 316-744-7151
Kice Industries, Inc.
Fax: 316-744-7355
5500 Mill Heights Dr

Wichita, KS 67219
USA

Quote Number: 122254 Quote Page: 3 of 4

Line Quantity Part Description


5 500 TUBERD11X6X20CSP Painted Round Tubing 11ga, 6"OD, Carbon Steel 7.536lbs/ft
Customer should expect dirt and oil on the interior of this part. Customer will need to inspect the interior and possibly clean
the interior prior to installation. If this is unacceptable, please advise.
Quantity Unit Price Net Price
500 FT 28.00 14,000.00 USD

Line Quantity Part Description


6 4 SANDELL6 6" Kice Sand Elbow with Ends to OD Tube
Quantity Unit Price Net Price
4 EA 569.00 2,276.00 USD

Line Quantity Part Description


7 35 82M6-4CW Compression Coupling with White Gasket and SS Ground Strip, 6"
OD tube, 4 bolt, Galvanized Construction
Quantity Unit Price Net Price
35 EA 35.00 1,225.00 USD

Line Quantity Part Description


8 1 FREIGHT Insurance and freight to Callao Port, PERU
Quantity Unit Price Net Price
1 EA 8,787.00 8,787.00 USD

Line Quantity Part Description


10 6 1-1156-04 Filter Insert, #3 FMG 5 & 6, 12 x 12
Quantity Unit Price Net Price
6 EA 69.00 414.00 USD

Grand Total $ $70,097.00

Print Date:7/7/2021 03:06 PM


Phone: 316-744-7151
Kice Industries, Inc.
Fax: 316-744-7355
5500 Mill Heights Dr

Wichita, KS 67219
USA

Quote Number: 122254 Quote Page: 4 of 4

General Terms And Conditions


This is a part of our agreement to you for all products and /or services to be furnished by Kice Industries. Its terms and conditions, including warranty, unless
amended and agreed to by an authorized Kice representative in writing, constitute our formal terms and conditions contained in any form supplied by you.

1. Prices and Acceptance: All quotations are valid for twenty-four (24) hours from date of quotation unless otherwise agreed upon in writing. Sale of goods
is not considered complete until the order is accepted at the Kice corporate office by an officer who is authorized to accept orders. All prices are net and do
not include local, state, or federal sales, use, or excise taxes or other similar taxes, whether now in force or to be enforced later. In the event the transaction is
subject to any such taxes, Kice Industries, Inc. will invoice you accordingly.
The above price DOES NOT include Crating or Freight fees. These will be added to the customer’s invoice.
2. Terms of Payment: Payment terms will be based on order value, subject to credit approval. (Effective on Orders Placed on or after 02/01/16)
Domestic Orders (US and Canada)
$0 - $49K Net 30
$50 - $100K 30% upon placement of PO, 70% net 30
$100 - $250K 30% upon placement of PO, 40% prior to shipment, 30% net 30
Over $250K TBD
International orders
$0 - $49K 100% Prior to Shipment
Over $50K 30% upon placement of PO, 70% prior to shipment.
Price does not include CE or ATEX compliance.
3. Customer Responsibility:
A. The customer is responsible for establishing and enforcing electrical safety program and procedures for anyone operating, maintaining, or interfacing
with the system.
B. The customer is responsible for providing safety training for anyone operating, maintaining, or interfacing with the system.
C. The customer is responsible for implementing and enforcing an OSHA approved Lockout-Tagout program.
D. While Kice Industries makes every effort to clean our finished products prior to shipment, it is the customer's responsibility (especially food production
customers) to inspect and, if necessary clean each item they receive from Kice Industries prior to installing it.
4. Promise of Delivery: The estimated delivery dates represent our best estimate of the time required to complete the work and ship the product from our
plant. Estimated delivery dates are based on prompt receipt of all details pertaining to the order. Kice shall not be liable for any losses or damages (including
consequential or incidental damages) which result from delay or failure to deliver any or all of the products ordered on or before the estimated delivery date.
5. Cancellation: Orders may not be cancelled after acceptance by Kice except in writing and upon terms that will indemnify Kice against any damages or
losses resulting from the cancellation.
6. Returned Goods: No products may be returned and accepted for credit unless such return is first authorized in writing by Kice, prepaid and in good
condition upon receipt.
7. Indemnification: Kice will defend any suit or proceeding brought based upon alleged infringement of a U .S. patent by an product which Kice has designed;
provided, however, that Kice is to be notified in writing immediately by you, and given full information and immediate authority (where necessary) to assist in
the preparation of the defense of such action. Kice is to have full discretion in the handling of such action or proceeding and shall have authority to litigate,
settle and/or modify the product furnished in Kice's discretion. If you have supplied the design of the product furnished hereunder, you shall hold Kice
harmless of all claims of infringement, and indemnify and defend Kice against such claims.
8. Limited Warranty and Limitations of Warranty: Kice warrants the products manufactured by Kice to be free of defects in material and workmanship for a
period of one (1) year from the date of shipment. Kice agrees to repair or replace, at its discretion, any part found defective in the opinion of Kice. Kice is not
liable for any cost in connection with the removal, shipment or reinstallation of said parts. This warranty does not apply to abrasion, corrosion, erosion, abuse
or misuse of the product. Assistance by Kice in system layout or selecting equipment does not imply Kice's responsibility. Buyer agrees to look solely to the
warranty, if any, of the manufacturer or supplier of products manufactured by others and supplied by Kice for any alleged defects in such products and for any
damages or injuries caused thereby or as a result thereof. Where work is made to measurements or specifications furnished by the Buyer, Kice does not
assume any responsibility for the accuracy of the Buyer ’s specifications. Kice will not assume responsibility for alteration or repairs unless the same are made
with the written consent and approval of Kice. Buyer shall be responsible for compliance with electrical manufacturer's recommendations,
underwriter's code, and all safety precautions. Kice extends no other warranty for any of its products other than the above expressed warranty and
there are no other warranties, express or implied, including warranties of merchantability, fitness for a particular purpose or otherwise which
extend beyond the above limited expressed warranty. Kice and its dealers shall not in any event be liable for consequential or incidental damages and the
terms and conditions stated herein provide Buyer's sole and exclusive remedy. Any action for breach of agreement or warranty must be commenced within
one year after cause of action has accrued.
9. Governing Law: All agreement with Kice will be governed by and construed according to the laws of the state of Kansas.
10. Explosion Containment and Isolation Requirements: Explosion venting or suppression requirements are to be determined by customer, based on local
regulations or NFPA standards. Per NFPA 68, the customer is responsible for providing Kice Industries with current and accurate Kst and Pmax values for the
material being handled. For purposes of quoting, we have either not quoted explosion vents or estimated the number of vents required based on industry
published data. If ordered, explosion vent quantity and sizing is to be verified by Kice Engineering, based on customer supplied data, and our quote may be
subject to change to meet current NFPA standards. Kice Industries can help facilitate determination of the needed values by working through one of our
suppliers. Explosion suppression and isolation is related to explosion venting, but is not being considered on this quote, unless specifically addressed within
the quote. If ducting is to be attached to the explosion vents, see NFPA 68 for vent size regulations and specify at time of order. Cross sectional area varies
according to product and filter size.

Print Date:7/7/2021 03:06 PM