* If you upgrade to ver. 2.80 or higher, please be sure to uninstall the currently using GTWIN (ver.
below 2.80) first, as ver. 2.8 or higher only supports Windows 2000, XP, Vista and 7. Follow the
screen prompts displayed.
* If you upgrade to ver.2.71 or higher, please be sure to uninstall the currently using GTWIN (ver.
below 2.70) first, as a destination folder for installing ver. 2.71 or higher is changed. Follow the
screen prompts displayed.
* If you downgrade to ver 2.C11 or lower, please be sure to uninstall the currently using GTWIN first.
Follow the screen prompts displayed.
Version-up Information
Ver.2.E1 to Ver.2.E11
Ver.2.E01 to Ver.2.E1
Ver.2.D0 to Ver.2.E01
Ver.2.C2 to Ver.2.D0
Ver.2.C11 to Ver.2.C2
Ver.2.C1 to Ver.2.C11
Corrected the error that the setting of GT Configuration in which "RS/CS control" is set to "Off"
cannot be transferred when using general-purpose serial communication with GT32 (E type).
Corrected the error that the upgrade version cannot be installed on a PC in which GTWIN
Ver2.0 or Ver2.1 has been installed.
Ver.2.C0 to Ver.2.C1
Ver.2.B2 to Ver.2.C0
Ver.2.B1 to Ver.2.B2
[GT01(Ver.1.39)/GT11(Ver.1.29)/GT21(Ver.1.19) firmware]
Corrected the error that the screen may flicker when the backlight is set to a value other than
the maximum value.
[GT02(Ver.1.11)/GT02L(Ver.1.01)/GT05(Ver.1.71)/GT12(Ver.1.41)/GT32(Ver.1.81) firmware]
Ver.2.A2 to Ver.2.B0
[GT02(Ver1.10)/GT05(Ver1.70)/GT12(Ver1.40)/GT32(Ver1.80) firmware]
Added the "True Type(GTWIN)" and "Windows(R)" font display function for the Data parts,
Clock parts and the numerical display of Bar graph parts.
Modified the first communication time-out period to be shortened in order to connect to the
PLC quickly.
Corrected the error that the clock does not work punctually even if Clock Type is set to PLC
Clock with GT02 (without SD card).
Corrected the error that GT freezes when the condition of Reverse/Blink setting becomes true
while the conditions of a lot of parts are true.
Corrected the error that GT may freeze on the "Screen No Error" screen when the GT Link
function is used.
Corrected the error that the previous character string is displayed momentarily when inputting
the data parts the data format of which is "Character String" on Keyboard screen.
Corrected the error that the screen changes to "SD->GT" screen when there is no screen data
and the "SD File Delete" button in the system menu is touched.
Ver.2.A1 to Ver.2.A2
[GT02(Ver.1.03) firmware]
Corrected the error that the backlight color changes or the backlight is not turned on once a
communication error has occurred when using Keyence PLC.
[GT05(Ver1.63)/GT32(Ver1.73) firmware]
Corrected the error that the flow display may not be displayed. (Color models only)
Ver.2.A0 to Ver.2.A1
[GT02(Ver.1.02)/GT05(Ver.1.62)/GT12(Ver.1.32)/GT32(Ver.1.72) firmware]
Corrected the error that another screen may be displayed right after changing the screen.
Corrected the error that the format error may occur when writing SD recipe data into a SD
card.
Corrected the error that GT freezes if attempting to display keyboard screen when the forced
display flag is on.
Ver.2.993 to Ver.2.A0
[GT05(Ver.1.61)/GT12(Ver.1.31)/GT32(Ver.1.71) firmware]
Added the SD recipe function.
Added the alarm history data save in SD memory card.
Added the "Skip Communication Error Station" function for using the PLC multiple connection
function.
Added multiplication and division to the write device function.
Added four arithmetic operations between devices to the write device function.
Added the operation not to create a POW file for the data logging function.
Corrected the error that "**00FF" is displayed when the communication with a PLC was
disconnected momentarily and reconnected quickly.
Corrected the error that GT does not start when the data parts the data type of which is
Character String and the GT link function is used simultaneously.
Corrected the error that the data logged with difference values may not be correctly displayed
when it is displayed with line graph parts.
Corrected the error that a disturbance in screen display occurs when executing reading a
recipe while the keyboard screen is displayed.
Corrected the error that GT freezes when the recipe file that exceeds the maximum capacity is
transferred from GTWIN.
Corrected the error that a communication error may occur when jumping to the keyboard
screen when connecting multiple PLCs.
Corrected the error that GT may freeze when executing reading a recipe while the data
logging has been set.
Ver.2.99 to Ver.2.993
[GT05(Ver.1.51)/GT12(Ver.1.21)/GT32(Ver.1.61) firmware]
Corrected the error for the data parts the data type of which is Float that a minus sign is not
displayed even though the number is a negative number when a carry is produced as a result
of rounding.
Corrected the error that POW files of data logging with the same content are created any
number of times when the power turns on.
Corrected the error that GT may stop when jumping to the administrator's management
screen for the operation security function.
Corrected the error that the difference values logged by the data logging function may not be
stored correctly.
Corrected the error in the graph display of log data that the graph is displayed on a one-tenth
scale when the number after the decimal point is 0.
Corrected the error that a point in the screen closest to the touched point is considered that
was touched when touching the point located out of the screen.
Corrected the error that data logged in ASCII data format cannot be saved for the specified
number of digits when PLC type is "General-purpose serial".
Corrected the error in the data logging function that the on/off state of Output during write to
SD card may not be recognized when it has been set in the internal device.
Corrected the error that GT may freeze when the "GT>SD" button is touched inserting a SD
card while using the GT link function.
Corrected the error that the value of GDT0034 is rewritten when log data is saved in a SD
card with the data logging function.
Corrected the error that values in BCD format are output in DEC format when outputting the
maximum values of line graph parts.
Corrected the error in the line graph parts the reference data of which has been set in a SD
card (logging data) that the value of 256,512,768 is not graphically displayed in the correct
position.
Corrected the error in the line graph parts the reference data of which has been set in a SD
card (logging data) that the specification error of Term setting device is not deleted even the
status has been recovered after the occurrence of the error.
Corrected the error that the GT may hang when more than 70 log files of the data logging
function are saved in one folder.
Ver.2.983 to Ver.2.99
[GT05(Ver.1.50)/GT12(Ver.1.20)/GT32(Ver.1.60) firmware]
Supports the displays in simplified Chinese / traditional Chinese / Korean for data parts.
Added the graph display function for log data.
Supports the bar graph display for line graph parts.
Ver.2.981 to Ver.2.983
[GT05(Ver.1.42)/GT12(Ver.1.12)/GT32(Ver.1.52) firmware]
Modified the phenomenon that GT does not start up when the firmware has been downgraded.
Ver.2.97 to Ver.2.981
[GT05(Ver.1.41)/GT12(Ver.1.11)/GT32(Ver.1.51) firmware]
Ver.2.96 to Ver.2.97
[GT32(Ver1.40)/GT05(Ver1.30) firmware]
Added "Multi function" function that enables multiple operation settings for one function
switch/custom switch part. (GT05,GT12,GT32)
More than one Panasonic FP-series PLC can be connected.(GT05,GT12,GT32)
Modified the phenomenon that the switch cannot be turned off if the screen has been changed
while the momentary switch is being continuously pressed.
Modified the phenomenon that the parts are not inverted or flash when transparent lamp parts
have been pasted.
Ver.2.95 to Ver.2.96
[GT01(Ver.1.35)/GT11(Ver.1.25)/GT21(Ver.1.15) firmware]
[GT32(Ver.1.30)/GT05(Ver.1.20) firmware]
Added the buzzer enabled flag in the basic communication area (bit area).
Modified the phenomenon that aother part overlapped with a transparent custom switch part
cannot be seen.
Modified the phenomenon that the part of another part overlapped with a blinking part is not
drawn.
Modified the phenomenon that the drawing of bar graph part with the width of 16 dots or less
is missing.
Modified the phenomenon that the custom parts that "Change Attributes for Every
Appearance" has been specified are not replaced.
Modified the phenomenon that the clock loses more than 180 seconds per month on the
monochrome type GT32.
Modified the phenomenon that the parts drawings are disturbed when the number of
bitmapped parts on 1 base screen is the maximum limit.
Modified the phenomenon that a message is displayed at the bottom of the screen when
specifying a name for the login screen.
Modified the phenomenon that the guidance is not displayed for alarm list parts.
Ver.2.94 to Ver.2.95
Modified the phenomenon that the verify error occurs when verifying data including a
operation security password file.
Modified the phenomenon that the conversion error occurs when performing the GT model
conversion between GT01/GT10/GT11/GT21/GT30 and GT05/GT32.
Ver.2.93 to Ver.2.94
[GT32(Ver.1.20)/GT05(Ver.1.10) firmware]
Ver.2.92 to Ver.2.93
[GT32(Ver.1.15)/GT05(Ver.1.03) firmware]
Modified the problem that GT can't communicate with a external device when using the
general-purpose serial.
Modified the problem that "Transmission Delay" is not available when using the through
function.
Modified the problem that GT freezes when Basic Communication Area address of GT
configuration is bigger than the following address.
- Device of Hold Device Value
- Device of Recipe Control Device
- Monitoring start device of Alarm part /Device of Alarm History Control
- Sampling Start Device of Line Graph part/Device of Line Graph control
- Reference Device of Sound function
- Reference PLC Device of Muluti-Language Exchange function
- Output Device of Clock transfer outside
Modified the problem that GT05C and GT32T don't work properly when screen data stored in
the internal flash memory is allocated in a certain location in rare cases.
Ver.2.91 to Ver.2.92
Modified the problem that the model name, GT05 was incorrectly displayed as GT30 on the
GTWIN in German.
Modified the problem that the screen data of VT30 did not open.
Modified the problem that the HELP doesn't appear even if F1 key is pushed while the setting
dialog about sound is displayed.
Modified the problem that as for Flow Display setting the address in condition on Message
screen is not correctly displayed in case of selecting Omron PLC.
Modified the problem that as for Flow Display setting "0" in the starting address can't be input.
Equipped with Ver1.20 of Keyence KV1000 driver on GT32 and GT05.
- Modified the problem that color-type GT05 did not operate correctly.
Equipped with Ver1.20 of Keyence KV700 driver on GT32 and GT05.
- Modified the problem that color-type GT05 did not operate correctly.
Equipped with Ver1.10 of Keyence KV10/16/24/40 driver on GT32 and GT05.
- Modified the problem that color-type GT05 did not operate correctly.
Equipped with Ver1.10 of Siemens S7-200 driver on GT32 and GT05.
- Modified the problem that the error "ER000A" is displayed when writing more 8 words occurs.
Equipped with the firmware of GT05 Ver.1.02.
Equipped with the firmware of GT32 Ver.1.14.
Improved the start-up time after turning on the power supply, and added the display "Now
Booting up" on the screen during power up.
Changed the screen switching method to display various parts after displaying the base.
Modified the problem that as for the alarm history parts, even if the bit turns on, the alarm
cannot be displayed if all the "Triggered", "Recovered" and "Acknowledged" boxes are not
checked.
Modified the problem that as for custom lamp or custom message parts, if those parts are
highlighted without display data, they cannot be hidden while they are highlighted.
Modified the problem that if recipe data larger than 32638 bytes are set, the unit does not
operate properly.
Modified the problem that when selecting the Siemens PLC model, the recipe, alarm list, line
graphs, sound, flow display, device hold, clock device and data part (ASCII format) functions
does not activate correctly.
Modified the problem that if the setting for the device hold function exceeds 8 words, data
cannot be written correctly.
Modified the problem that on the Ver.1.12, the copy function for screen data with the SD does
not activate properly when communication with PLC is not available.
Modified the problem that if the backlight forced flag is used, the backlight auto-off function
does not work properly.
Ver.2.82 to Ver.2.91
Supports the following models and the following phenomena was modified.
- Data cannot be written when data writing was performed to many devices with the recipe
function
- When using the copy function between GT and GT in case that the destination GT has a
password, the source GT may be broken.
- Supports both KV1000 (directly connected to CPU) and KV-L20R.
Ver.2.81 to Ver.2.82
The following points have been upgraded.
Ver.2.80 to Ver.2.81
Ver.2.71 to Ver.2.80
Supports GT32.
Added Simplified Chinese, German, Italian and Spanish in Menu.
Added text importing/exporting in language switching function.
240 dots size characters selectable.
Supports Keyence PLC (KV-10 and KV-40)
Upgraded the firmware of GT01 (Ver.1.31), GT11 (Ver.1.21) and GT21 (Ver1.11).
Ver.2.70 to Ver.2.71
Ver.2.63 to Ver.2.70
Supports GT21.
Upgraded the firmware of GT01 (Ver.1.23) and GT11 (Ver.1.04).
Ver.2.62 to Ver.2.63
Ver.2.61 to Ver.2.62
Ver.2.60 to Ver.2.61
Ver.2.5 to Ver.2.6
Added GT01 drivers for other company's PLC.[Mitsubishi Electric A Series (Computer Link)/
Yokogawa Electric FA-M3 Series/ Allen-Bradly/ LG MASTER-K Series(C-net)]
Ver.2.45 to Ver.2.5
Ver.2.44 to Ver.2.45
Ver.2.43 to Ver.2.44
Ver.2.41 to Ver.2.42
Ver.2.4 to Ver.2.41
Added GT01 drivers for other company's PLC [OMRON SYSMAC-C Series].
Ver.2.3 to Ver.2.4
Ver.2.22 to Ver.2.3
Supports GT01.
Ver.2.21 to Ver.2.22
Added GT01 drivers for other company's PLC [Yokogawa Electric FA-M3 Series].
Ver.2.2 to Ver.2.21
Ver.2.11 to Ver.2.2
The following points have been upgraded.
Ver.2.1 to Ver.2.11
Ver.2.0 to Ver.2.1
Added compression function of GT30 screen data (ver.1.10 or higher GT30 firmware required).
Supports 2-point pressing of GT30 touch switch.
With Windows OS 2000, Japanese, English, Simplified Chinese, Traditional Chinese, and
Korean supported.