DSE8610 MKII
SPECIFICATIONS
DC SUPPLY
CONTINUOUS VOLTAGE RATING
CRANKING DROPOUTS
AUTO START CONTROL MODULE Able to survive 0 V for 100 mS, providing
supply was at least 10 V before dropout
and supply recovers to 5 V. This is
achieved without the need for internal
batteries. LEDs and backlight will not be
maintained during cranking.
EXPANSION DEVICES
• DSE124 CAN/MSC Extender MAXIMUM OPERATING CURRENT
• DSE2130 Input Expansion 530 mA at 12 V, 280 mA at 24 V
Deep Sea Electronics Ltd maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457 055-204/06/20 (3)
DSEGenset®
DSE8610 MKII
ENVIRONMENTAL TESTING STANDARDS
SYNCHRONISING & LOAD SHARING EMC Generic Immunity Standard for the
Industrial Environment
ELECTRICAL SAFETY
The DSE8610 MKII is a market- features are included. KEY LOAD SHARE FEATURES: BS EN 60950
Safety of Information Technology Equipment,
leading Synchronising Auto Start Designed to offer increased built • Peak lopping/sharing (with including Electrical Business Equipment
Control Module suitable for use in a in support for active sensors for appropriate DSE mains controller)
multi-generator loadshare system, 0 V to 10 V & 4 mA to 20 mA. • Sequential set start TEMPERATURE
BS EN 60068-2-1
designed to synchronise up to 32 Comprehensive communication • Manual voltage/frequency Ab/Ae Cold Test -30 oC
generators including electronic and and system expansion options are adjustment BS EN 60068-2-2
non-electronic engines. available. • R.O.C.O.F. and vector shift Bb/Be Dry Heat +70 oC
protection
VIBRATION
The DSE8610 MKII monitors the Using the DSE PC Configuration Suite • Generator load demand BS EN 60068-2-6
generator and indicates operational Software allows easy alteration of the • Automatic hours run balancing Ten sweeps in each of three major axes
status and fault conditions, operational sequences, timers and • Mains (Utility) decoupling 5 Hz to 8 Hz at +/-7.5 mm, 8 Hz to 500 Hz
at 2 gn
automatically starting or stopping alarms. With all communication ports • Mains (Utility) decoupling
the engine on load demand or fault capable of being active at the same test mode HUMIDITY
conditions. time, the DSE8610 MKII is ideal for a • Dead bus sensing BS EN 60068-2-30
wide variety of demanding load share • Bus failure detection Db Damp Heat Cyclic 20/55 oC at 95% RH
48 Hours
System alarms are annunciated on applications. • Direct governor and AVR control BS EN 60068-2-78
the LCD screen (multiple language • Volts and frequency matching Cab Damp Heat Static 40 oC at 93% RH
options available), illuminated LED The Advanced PLC tool within • kW and kvar load sharing 48 Hours
and audible sounder. Configuration Suite provides • Dead bus synchronising SHOCK
users with an extremely powerful BS EN 60068-2-27
The event log records 250 events to configuration tool for the most Three shocks in each of three major axes
15 gn in 11 mS
facilitate easy maintenance, and an demanding applications.
extensive number of fixed and flexible DEGREES OF PROTECTION
monitoring, metering and protection PROVIDED BY ENCLOSURES
BS EN 60529
IP65 - Front of module when installed into the
control panel with the supplied sealing gasket.
DSENET® RS232 AND USB USB CONFIGURABLE DC OUTPUTS ANALOGUE EMERGENCY DC POWER
EXPANSION RS485 PORT HOST INPUTS SENDERS STOP SUPPLY 8-35V
+
ETHERNET
DEUTZ DETROIT
BUS VOLT FREE GENERATOR SENSING FUEL & START CHARGE ELECTRONIC MAGNETIC
SENSING OUTPUTS OUTPUTS ALTERNATOR ENGINES PICK-UP
CURRENT VOLTS D+
+ W/ L
ISSUE 3