Date: February 19, 2020

RELIABILITY ENGINEERING
MTTF and FIT Calculation Report

Part Number Family


: 1N4148 / 1N4448 / 1N914B Test : HTRB
Series

Enter the Test Variables:


No. of failures = 0 units
No. of devices = 120 units
No. of hours = 168 hours
Total no. of device hours = 20,160 hours
Accelerated Temp (Ta) = 150 °C
Operating Temp (Tu) = 50 °C
Activation Energy (Ea) = 1.0 eV
Confidence Level = 80 %
Boltzman's Constant (k) = 8.617E-05 eV / °K
Calculations:
Chi squared value = 3.218875825 @ 80% Confidence Level

(Chi squared value)


Failure Rate (@Ta) =
2(No of devices)(No of hours)
= 79833.23 FIT

Acceleration Factor = e(Ea/k)(1/Tu - 1/Ta)


= 4884.294739

Failure Rate (@Tu) = (Failure Rate (@Ta)) / (Acceleration Factor)

= 16.34 FIT

MTTF = 61,181,224.31 hours

= 6,984.2 years