Pulling Direction On The Bullwheel
Pulling Direction On The Bullwheel
Pulling Direction On The Bullwheel
A ‘Large Diameter’ component must never be used to pull a ‘Smaller Diameter’ component under
Tension over the Bullwheel of a Puller or a Tensioner – refer to Fig 1.
The reason for this is that the difference between the two diameters generates an increased
stress at the joining of the two components - which will most likely result in a catastrophic failure
of the smaller diameter component.
The above criteria must still be implemented in all cases even if the difference in diameter of the
two components is minimal – refer to the example below.
Pulling a Smaller Diameter Pulling a Larger Diameter
with a Larger Diameter with a Smaller Diameter
Fig.1 X Fig.2 V
10/12/2010 Tesmec Presentation-SE-AS-Instruction, warnings, use and maintenance - GB - Rev02 15/102