Test Report issued under the responsibility of:

TEST REPORT
IEC 60335-2-9
Safety of household and similar electrical appliances
Part 2: Particular requirements for grills, toasters and similar cooking
appliances

Report Number...................................: CQCSCL0116-0178


Date of issue....................................... : 2017.03.10
Total number of pages...................... 375 pages

Name of Testing Laboratory China Quality Certification Centre South China Laboratory
preparing the Report........................ :
Applicant’s name...............................: Zhongshan Haotong Electrical Appliances Co., Ltd.
Address................................................: No.3 Sanjiao Section of Panzhong Highway, Sanjiao Town,
Zhongshan, Guangdong, P.R. China
Test specification:
Standard.............................................. : IEC 60335-2-9:2008 (Sixth edition) +A1: 2012 in conjunction with
IEC 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr.
2:2011 + A1:2013
Test procedure................................... : CB Scheme
Non-standard test method.............. : N/A
Test Report Form No........................ : IEC60335_2_9M
Test Report Form(s) Originator..... : LCIE
Master TRF.......................................... : Dated 2015-10
Copyright © 2015 IEC System of Conformity Assessment Schemes for Electrotechnical
Equipment and Components (IECEE System). All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting
from the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the
CB Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory
and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
General disclaimer:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing
Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB,
responsible for this Test Report.
Page 2 of 375 Report No. CQCSCL0116-0178

Test item description.......................... : Electric oven


Trade Mark............................................. : N/A
Manufacturer......................................... : Zhongshan Haotong Electrical Appliances Co., Ltd.
Model/Type reference......................... : HK-P55,HK-P55R,HK-P55C,HK-P55L,HK-P55RL,HK-P55CL,HK-
P55RC,HK-P55RCL,55L 3000W; HK-12002,HK-12002R,HK-
12002C,HK-12002L,HK-12002RL,HK-12002CL,HK-12002RC,HK-
12002RCL 120L 2800W;HK-120,HK-120R,HK-120C,HK-120L,HK-
120RL,HK-120CL,HK-120RC,HK-120RCL 120L 2800W;HK-
10002,HK-10002R,HK-10002C,HK-10002L,HK-10002RL,HK-
10002CL,HK-10002RC,HK-10002RCL 100L 2800W;HK-100,HK-
100R,HK-100C,HK-100L,HK-100RL,HK-100CL,HK-100RC,HK-
100RCL 100L 2800W;HK-P75,HK-P75R,HK-P75C,HK-P75L,HK-
P75RL,HK-P75CL,HK-P75RC,HK-P75RCL 75L 2800W;HK-75,HK-
75R,HK-75C,HK-75L,HK-75RL,HK-75CL,HK-75RC,HK-75RCL 75L
2200W;HK-95,HK-95R,HK-95C,HK-95L,HK-95RL,HK-95CL,HK-
95RC,HK-95RCL 95L 2400W;HK-85,HK-85R,HK-85C,HK-85L,HK-
85RL,HK-85CL,HK-85RC,HK-85RCL 85L 2400W;HK-8002,HK-
8002R,HK-8002C,HK-8002L,HK-8002RL,HK-8002CL,HK-
8002RC,HK-8002RCL 80L 2400W;HK-8001,HK-8001R,HK-
8001C,HK-8001L,HK-8001RL,HK-8001CL,HK-8001RC,HK-
8001RCL 80L 2400W;HK-80,HK-80R,HK-80C,HK-80L,HK-
80RL,HK-80CL,HK-80RC,HK-80RCL 80L 2400W;HK-7002,HK-
7002R,HK-7002C,HK-7002L,HK-7002RL,HK-7002CL,HK-
7002RC,HK-7002RCL 70L 2400W;HK-7001,HK-7001R,HK-
7001C,HK-7001L,HK-7001RL,HK-7001CL,HK-7001RC,HK-
7001RCL 70L 2400W;HK-70,HK-70R,HK-70C,HK-70L,HK-
70RL,HK-70CL,HK-70RC,HK-70RCL 70L 2400W;HK-7501,HK-
7501R,HK-7501C,HK-7501L,HK-7501RL,HK-7501CL,HK-
7501RC,HK-7501RCL 75L 2200W;HK-6008,HK-6008R,HK-
6008C,HK-6008L,HK-6008RL,HK-6008CL,HK-6008RC,HK-
6008RCL 60L 2200W;HK-6006,HK-6006R,HK-6006C,HK-
6006L,HK-6006RL,HK-6006CL,HK-6006RC,HK-6006RCL 60L
2200W;HK-6005,HK-6005R,HK-6005C,HK-6005L,HK-6005RL,HK-
6005CL,HK-6005RC,HK-6005RCL 60L 2200W;HK-6004,HK-
6004R,HK-6004C,HK-6004L,HK-6004RL,HK-6004CL,HK-
6004RC,HK-6004RCL 60L 2200W;HK-6003,HK-6003R,HK-
6003C,HK-6003L,HK-6003RL,HK-6003CL,HK-6003RC,HK-
6003RCL 60L 2200W;HK-6002,HK-6002R,HK-6002C,HK-
6002L,HK-6002RL,HK-6002CL,HK-6002RC,HK-6002RCL 60L
2200W;HK-60,HK-60R,HK-60C,HK-60L,HK-60RL,HK-60CL,HK-
60RC,HK-60RCL 60L 2200W;HK-6009,HK-6009R,HK-6009C,HK-
6009L,HK-6009RL,HK-6009CL,HK-6009RC,HK-6009RCL 60L
2000W;HK-56,HK-56R,HK-56C,HK-56L,HK-56RL,HK-56CL,HK-
56RC,HK-56RCL 56L 2000W;HK-55,HK-55R,HK-55C,HK-55L,HK-
55RL,HK-55CL,HK-55RC,HK-55RCL 55L 2000W;HK-5501,HK-
5501R,HK-5501C,HK-5501L,HK-5501RL,HK-5501CL,HK-
5501RC,HK-5501RCL 55L 2000W;HK-53,HK-53R,HK-53C,HK-
53L,HK-53RL,HK-53CL,HK-53RC,HK-53RCL 53L 2000W;HK-
5202,HK-5202R,HK-5202C,HK-5202L,HK-5202RL,HK-5202CL,HK-
5202RC,HK-5202RCL 52L 2000W;HK-P50,HK-P50R,HK-P50C,HK-
P50L,HK-P50RL,HK-P50CL,HK-P50RC,HK-P50RCL 50L
2000W;HK-5002,HK-5002R,HK-5002C,HK-5002L,HK-5002RL,HK-
5002CL,HK-5002RC,HK-5002RCL 50L 2000W;HK-5001,HK-
5001R,HK-5001C,HK-5001L,HK-5001RL,HK-5001CL,HK-
5001RC,HK-5001RCL 50L 2000W;HK-50B,HK-50BR,HK-50BC,HK-

TRF No. IEC60335_2_9M


Page 3 of 375 Report No. CQCSCL0116-0178

50BL,HK-50BRL,HK-50BCL,HK-50BRC,HK-50BRCL 50L
2000W;HK-5004,HK-5004R,HK-5004C,HK-5004L,HK-5004RL,HK-
5004CL,HK-5004RC,HK-5004RCL 50L 2000W;HK-5005,HK-
5005R,HK-5005C,HK-5005L,HK-5005RL,HK-5005CL,HK-
5005RC,HK-5005RCL 50L 2000W;HK-5006,HK-5006R,HK-
5006C,HK-5006L,HK-5006RL,HK-5006CL,HK-5006RC,HK-
5006RCL 50L 2000W;HK-5008,HK-5008R,HK-5008C,HK-
5008L,HK-5008RL,HK-5008CL,HK-5008RC,HK-5008RCL 50L
1800W;HK-5007,HK-5007R,HK-5007C,HK-5007L,HK-5007RL,HK-
5007CL,HK-5007RC,HK-5007RCL 50L 1800W;HK-4802,HK-
4802R,HK-4802C,HK-4802L,HK-4802RL,HK-4802CL,HK-
4802RC,HK-4802RCL 48L 1800W;HK-4803,HK-4803R,HK-
4803C,HK-4803L,HK-4803RL,HK-4803CL,HK-4803RC,HK-
4803RCL 48L 1600W;HK-46,HK-46R,HK-46C,HK-46L,HK-
46RL,HK-46CL,HK-46RC,HK-46RCL 46L 2000W;HK-4501,HK-
4501R,HK-4501C,HK-4501L,HK-4501RL,HK-4501CL,HK-
4501RC,HK-4501RCL 45L 2000W;HK-45,HK-45R,HK-45C,HK-
45L,HK-45RL,HK-45CL,HK-45RC,HK-45RCL 45L 2000W;HK-
4504,HK-4504R,HK-4504C,HK-4504L,HK-4504RL,HK-4504CL,HK-
4504RC,HK-4504RCL 45L 2000W;HK-4505,HK-4505R,HK-
4505C,HK-4505L,HK-4505RL,HK-4505CL,HK-4505RC,HK-
4505RCL 45L 2000W;HK-B44,HK-B44R,HK-B44C,HK-B44L,HK-
B44RL,HK-B44CL,HK-B44RC,HK-B44RCL 44L 1800W;HK-43,HK-
43R,HK-43C,HK-43L,HK-43RL,HK-43CL,HK-43RC,HK-43RCL 43L
1800W;HK-4303,HK-4303R,HK-4303C,HK-4303L,HK-4303RL,HK-
4303CL,HK-4303RC,HK-4303RCL 43L 2000W;HK-4302,HK-
4302R,HK-4302C,HK-4302L,HK-4302RL,HK-4302CL,HK-
4302RC,HK-4302RCL 43L 1800W;HK-4305,HK-4305R,HK-
4305C,HK-4305L,HK-4305RL,HK-4305CL,HK-4305RC,HK-
4305RCL 43L 1800W;HK-4307,HK-4307R,HK-4307C,HK-
4307L,HK-4307RL,HK-4307CL,HK-4307RC,HK-4307RCL 43L
1600W;HK-42,HK-42R,HK-42C,HK-42L,HK-42RL,HK-42CL,HK-
42RC,HK-42RCL 42L 2000W;HK-4202,HK-4202R,HK-4202C,HK-
4202L,HK-4202RL,HK-4202CL,HK-4202RC,HK-4202RCL 42L
1600W;HK-4203,HK-4203R,HK-4203C,HK-4203L,HK-4203RL,HK-
4203CL,HK-4203RC,HK-4203RCL 42L 1600W;HK-4204,HK-
4204R,HK-4204C,HK-4204L,HK-4204RL,HK-4204CL,HK-
4204RC,HK-4204RCL 42L 1600W;HK-40,HK-40R,HK-40C,HK-
40L,HK-40RL,HK-40CL,HK-40RC,HK-40RCL 40L 1800W;HK-
4001,HK-4001R,HK-4001C,HK-4001L,HK-4001RL,HK-4001CL,HK-
4001RC,HK-4001RCL 40L 1800W;HK-4002,HK-4002R,HK-
4002C,HK-4002L,HK-4002RL,HK-4002CL,HK-4002RC,HK-
4002RCL 40L 1800W;HK-4003,HK-4003R,HK-4003C,HK-
4003L,HK-4003RL,HK-4003CL,HK-4003RC,HK-4003RCL 40L
1600W;HK-3803,HK-3803R,HK-3803C,HK-3803L,HK-3803RL,HK-
3803CL,HK-3803RC,HK-3803RCL 38L 1600W;HK-3807,HK-
3807R,HK-3807C,HK-3807L,HK-3807RL,HK-3807CL,HK-
3807RC,HK-3807RCL 38L 1600W;HK-3804,HK-3804R,HK-
3804C,HK-3804L,HK-3804RL,HK-3804CL,HK-3804RC,HK-
3804RCL 38L 1600W;HK-38,HK-38R,HK-38C,HK-38L,HK-
38RL,HK-38CL,HK-38RC,HK-38RCL 38L 1600W;HK-3806,HK-
3806R,HK-3806C,HK-3806L,HK-3806RL,HK-3806CL,HK-
3806RC,HK-3806RCL 38L 1600W;HK-36,HK-36R,HK-36C,HK-
36L,HK-36RL,HK-36CL,HK-36RC,HK-36RCL 36L 1600W;HK-
3602,HK-3602R,HK-3602C,HK-3602L,HK-3602RL,HK-3602CL,HK-
3602RC,HK-3602RCL 36L 1600W;HK-3603,HK-3603R,HK-

TRF No. IEC60335_2_9M


Page 4 of 375 Report No. CQCSCL0116-0178

3603C,HK-3603L,HK-3603RL,HK-3603CL,HK-3603RC,HK-
3603RCL 36L 1600W;HK-35,HK-35R,HK-35C,HK-35L,HK-
35RL,HK-35CL,HK-35RC,HK-35RCL 35L 1600W;HK-3504,HK-
3504R,HK-3504C,HK-3504L,HK-3504RL,HK-3504CL,HK-
3504RC,HK-3504RCL 35L 1600W;HK-3505,HK-3505R,HK-
3505C,HK-3505L,HK-3505RL,HK-3505CL,HK-3505RC,HK-
3505RCL 35L 1600W;HK-3506,HK-3506R,HK-3506C,HK-
3506L,HK-3506RL,HK-3506CL,HK-3506RC,HK-3506RCL 35
1500W;HK-3507,HK-3507R,HK-3507C,HK-3507L,HK-3507RL,HK-
3507CL,HK-3507RC,HK-3507RCL 35L 1500W;HK-3502,HK-
3502R,HK-3502C,HK-3502L,HK-3502RL,HK-3502CL,HK-
3502RC,HK-3502RCL 35L 1600W;HK-P34,HK-P34R,HK-P34C,HK-
P34L,HK-P34RL,HK-P34CL,HK-P34RC,HK-P34RCL 34L
2400W;HK-3403,HK-3403R,HK-3403C,HK-3403L,HK-3403RL,HK-
3403CL,HK-3403RC,HK-3403RCL 34L 1600W;HK-34,HK-34R,HK-
34C,HK-34L,HK-34RL,HK-34CL,HK-34RC,HK-34RCL 34L
1600W;HK-3404,HK-3404R,HK-3404C,HK-3404L,HK-3404RL,HK-
3404CL,HK-3404RC,HK-3404RCL 34L 1600W;HK-3406,HK-
3406R,HK-3406C,HK-3406L,HK-3406RL,HK-3406CL,HK-
3406RC,HK-3406RCL 34L 1500W;HK-33B,HK-33BR,HK-33BC,HK-
33BL,HK-33BRL,HK-33BCL,HK-33BRC,HK-33BRCL 33L
1600W;HK-3301,HK-3301R,HK-3301C,HK-3301L,HK-3301RL,HK-
3301CL,HK-3301RC,HK-3301RCL 33L 1500W;HK-32,HK-32R,HK-
32C,HK-32L,HK-32RL,HK-32CL,HK-32RC,HK-32RCL 32L
1600W;HK-3201,HK-3201R,HK-3201C,HK-3201L,HK-3201RL,HK-
3201CL,HK-3201RC,HK-3201RCL 32L 1500W;HK-3202,HK-
3202R,HK-3202C,HK-3202L,HK-3202RL,HK-3202CL,HK-
3202RC,HK-3202RCL 32L 1500W;HK-30,HK-30R,HK-30C,HK-
30L,HK-30RL,HK-30CL,HK-30RC,HK-30RCL 30L 1600W;HK-
P30,HK-P30R,HK-P30C,HK-P30L,HK-P30RL,HK-P30CL,HK-
P30RC,HK-P30RCL 30L 1600W;HK-3001,HK-3001R,HK-
3001C,HK-3001L,HK-3001RL,HK-3001CL,HK-3001RC,HK-
3001RCL 30L 1600W;HK-2808,HK-2808R,HK-2808C,HK-
2808L,HK-2808RL,HK-2808CL,HK-2808RC,HK-2808RCL 28L
1500W;HK-28,HK-28R,HK-28C,HK-28L,HK-28RL,HK-28CL,HK-
28RC,HK-28RCL 28L 1500W;HK-2805,HK-2805R,HK-2805C,HK-
2805L,HK-2805RL,HK-2805CL,HK-2805RC,HK-2805RCL 28L
1500W;HK-2806,HK-2806R,HK-2806C,HK-2806L,HK-2806RL,HK-
2806CL,HK-2806RC,HK-2806RCL 28L 1500W;HK-2801,HK-
2801R,HK-2801C,HK-2801L,HK-2801RL,HK-2801CL,HK-
2801RC,HK-2801RCL 28L 1380W;HK-2802,HK-2802R,HK-
2802C,HK-2802L,HK-2802RL,HK-2802CL,HK-2802RC,HK-
2802RCL 28L 1380W;HK-2803,HK-2803R,HK-2803C,HK-
2803L,HK-2803RL,HK-2803CL,HK-2803RC,HK-2803RCL 28L
1380W;HK-2804,HK-2804R,HK-2804C,HK-2804L,HK-2804RL,HK-
2804CL,HK-2804RC,HK-2804RCL 28L 1600W;HK-2809,HK-
2809R,HK-2809C,HK-2809L,HK-2809RL,HK-2809CL,HK-
2809RC,HK-2809RCL 28L 1500W;HK-P28,HK-P28R,HK-P28C,HK-
P28L,HK-P28RL,HK-P28CL,HK-P28RC,HK-P28RCL 28L
2400W;HK-26,HK-26R,HK-26C,HK-26L,HK-26RL,HK-26CL,HK-
26RC,HK-26RCL 26L 1500W;HK-2602,HK-2602R,HK-2602C,HK-
2602L,HK-2602RL,HK-2602CL,HK-2602RC,HK-2602RCL 26L
1500W;HK-2606,HK-2606R,HK-2606C,HK-2606L,HK-2606RL,HK-
2606CL,HK-2606RC,HK-2606RCL 26L 1500W;HK-2603,HK-
2603R,HK-2603C,HK-2603L,HK-2603RL,HK-2603CL,HK-
2603RC,HK-2603RCL 26L 1500W;HK-2605,HK-2605R,HK-

TRF No. IEC60335_2_9M


Page 5 of 375 Report No. CQCSCL0116-0178

2605C,HK-2605L,HK-2605RL,HK-2605CL,HK-2605RC,HK-
2605RCL 26L 1500W;HK-25,HK-25R,HK-25C,HK-25L,HK-
25RL,HK-25CL,HK-25RC,HK-25RCL 25L 1500W;HK-2501,HK-
2501R,HK-2501C,HK-2501L,HK-2501RL,HK-2501CL,HK-
2501RC,HK-2501RCL 25L 1500W;HK-2502,HK-2502R,HK-
2502C,HK-2502L,HK-2502RL,HK-2502CL,HK-2502RC,HK-
2502RCL 25L 1500W;HK-2504,HK-2504R,HK-2504C,HK-
2504L,HK-2504RL,HK-2504CL,HK-2504RC,HK-2504RCL 25L
1500W;HK-2505,HK-2505R,HK-2505C,HK-2505L,HK-2505RL,HK-
2505CL,HK-2505RC,HK-2505RCL 25L 1500W;HK-2506,HK-
2506R,HK-2506C,HK-2506L,HK-2506RL,HK-2506CL,HK-
2506RC,HK-2506RCL 25L 1500W;HK-P24,HK-P24R,HK-P24C,HK-
P24L,HK-P24RL,HK-P24CL,HK-P24RC,HK-P24RCL 24L
2300W;HK-2401,HK-2401R,HK-2401C,HK-2401L,HK-2401RL,HK-
2401CL,HK-2401RC,HK-2401RCL 24L 1500W;HK-2402,HK-
2402R,HK-2402C,HK-2402L,HK-2402RL,HK-2402CL,HK-
2402RC,HK-2402RCL 24L 1500W;HK-23,HK-23R,HK-23C,HK-
23L,HK-23RL,HK-23CL,HK-23RC,HK-23RCL 23L 1500W;HK-
2301,HK-2301R,HK-2301C,HK-2301L,HK-2301RL,HK-2301CL,HK-
2301RC,HK-2301RCL 23L 1500W;HK-2302,HK-2302R,HK-
2302C,HK-2302L,HK-2302RL,HK-2302CL,HK-2302RC,HK-
2302RCL 23L 1500W;HK-22,HK-22R,HK-22C,HK-22L,HK-
22RL,HK-22CL,HK-22RC,HK-22RCL 22L 1500W;HK-2201,HK-
2201R,HK-2201C,HK-2201L,HK-2201RL,HK-2201CL,HK-
2201RC,HK-2201RCL 22L 1500W;HK-20,HK-20R,HK-20C,HK-
20L,HK-20RL,HK-20CL,HK-20RC,HK-20RCL 20L 1500W;HK-
2001,HK-2001R,HK-2001C,HK-2001L,HK-2001RL,HK-2001CL,HK-
2001RC,HK-2001RCL 20L 1500W;HK-2003,HK-2003R,HK-
2003C,HK-2003L,HK-2003RL,HK-2003CL,HK-2003RC,HK-
2003RCL 20L 1500W;HK-2004,HK-2004R,HK-2004C,HK-
2004L,HK-2004RL,HK-2004CL,HK-2004RC,HK-2004RCL 20L
1500W;HK-19,HK-19R,HK-19C,HK-19L,HK-19RL,HK-19CL,HK-
19RC,HK-19RCL 19L 1380W;HK-1802,HK-1802R,HK-1802C,HK-
1802L,HK-1802RL,HK-1802CL,HK-1802RC,HK-1802RCL 18L
1380W; HK-1801,HK-1801R,HK-1801C,HK-1801RC 18L
1380W;HK-2304,HK-2304R,HK-2304C,HK-2304RC 23L
1380W;HK-65C,HK-65CL,HK-65RC,HK-65RCL 65L 2500W;HK-
1803,HK-1803R,HK-1803C,HK-1803RC 18L 1380W;HK-1601,HK-
1601R,HK-1601C,HK-1601RC 16L 1380W;HK-16,HK-16R,HK-
16C,HK-16RC,HK-16T,HK-16RT,HK-16CT 16L 1380W;HK-15,HK-
15R,HK-15C 15L 1200W,HK-14 14L 1200W;HK-1201 12L
1000W;HK-0906A3T 9L 800W;HK-0905A3 9L 800W;HK-09 9L
800W;HK-09T 9L 800W;HK-0902 9L 800W;HK-0904 9L 800W;HK-
0905 9L 800W;HK-0906 9L 800W;HK-P12 12L 800W;HK-XZ100
100L 2800W;HK-XZ100T 100L 2800W;HK-0908,HK-09M,HK-
09TM,HK-0902M,HK-0904M 9L 800W;
Ratings....................................................: 220-240V~ 50Hz/60Hz

TRF No. IEC60335_2_9M


Page 6 of 375 Report No. CQCSCL0116-0178

Responsible Testing Laboratory (as applicable), testing procedure and testing location(s):

CB Testing Laboratory: China Quality Certification Centre South China Laboratory


Testing location/ address................................ : No.11 South of Shenghui Road, Nantou, Zhongshan,
Guangdong, China
Associated CB Testing Laboratory: N/A
Testing location/ address................................ : N/A
Tested by (name, function, signature)......... : Ruan Zhimin
(Engineer)
Approved by (name, function, signature)... : Hu Xuhu (Reviewer)

Testing procedure: CTF Stage 1: N/A


Testing location/ address................................ :
N/A
Tested by (name, function, signature)......... : N/A
Approved by (name, function, signature)... : N/A

Testing procedure: CTF Stage 2: N/A


Testing location/ address................................ :
N/A
Tested by (name + signature).........................: N/A
Witnessed by (name, function, signature).. : N/A
Approved by (name, function, signature)... : N/A

Testing procedure: CTF Stage 3: N/A


Testing procedure: CTF Stage 4: N/A
Testing location/ address................................ :
N/A
Tested by (name, function, signature)......... : N/A
Witnessed by (name, function, signature).. : N/A
Approved by (name, function, signature)... : N/A
Supervised by (name, function, signature) : N/A

TRF No. IEC60335_2_9M


Page 7 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

List of Attachments (including a total number of pages in each attachment):


Attachment 1: 128 pages of photo documentation( page 248 - 375).

Summary of testing: The submitted appliances were tested and found to the compliances with the
requirements of IEC 60335-2-9:2008 (Sixth edition) +A1: 2012 in conjunction with IEC 60335-1:2010
(Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013.
Tests performed (name of test and test clause): Testing location:
Model HK-P55RCL was selected as the CB Testing Laboratory:
representative model for full tests. China Quality Certification Centre South China
Tests of Cl.7, Cl.8,Cl.22, Cl.24, Cl.29 were carried Laboratory
out on other models. Testing location/ address:
Tests of Cl.10 was carried out on models HK- No.11 South of Shenghui Road, Nantou,
12002,HK-P34RCL,HK-7501RCL,HK-6009RCL,HK- Zhongshan,Guangdong, China
5008RCL,HK-4803RCL,HK-3406,HK-2802RCL,HK-
15,HK-1201,HK-0906A3T,HK-09TM.
Tests of Cl.11, Cl.19 was carried out on models HX-
P55,HX-P55R,HK-P55C.
Tests of Cl.11 was carried out on models HK-09TM.

Summary of compliance with National Differences


List of countries addressed:
N/A

The product fulfils the requirements of _________ (insert standard number and edition and
delete the text in parenthesis, leave it blank or delete the whole sentence if not applicable)

TRF No. IEC60335_2_9M


Page 8 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Copy of marking plate:


The artwork below may be only a draft. The use of certification marks on a product must be
authorized by the respective NCBs that own these marks.

TRF No. IEC60335_2_9M


Page 9 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 10 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 11 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 12 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 13 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 14 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 15 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 16 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 17 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 18 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 19 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 20 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 21 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 22 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 23 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 24 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 25 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 26 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 27 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 28 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 29 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 30 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 31 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 32 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 33 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 34 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 35 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 36 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 37 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 38 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 39 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 40 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 41 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 42 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 43 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 44 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 45 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 46 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 47 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 48 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 49 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 50 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 51 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 52 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 53 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 54 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 55 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 56 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 57 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 58 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 59 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 60 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 61 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 62 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 63 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 64 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 65 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 66 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 67 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 68 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 69 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 70 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 71 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 72 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 73 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 74 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 75 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 76 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 77 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 78 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 79 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 80 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 81 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 82 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 83 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 84 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 85 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 86 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 87 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Test item particulars..................................................... :


Classification of installation and use........................: Portable appliance
Supply Connection........................................................ : Supply cord with plug,type Y attachment
............................................................................................:
Possible test case verdicts:
- test case does not apply to the test object............ : N/A
- test object does meet the requirement................... : P (Pass)
- test object does not meet the requirement............: F (Fail)
Testing.............................................................................. :
Date of receipt of test item........................................... : 2016.11.18
Date (s) of performance of tests................................. : 2016.11.18-2017.03.10

General remarks:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.

Throughout this report a comma / point is used as the decimal separator.

Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:


The application for obtaining a CB Test Certificate Yes
includes more than one factory location and a Not applicable
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided....................................................................:

When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies)............................ : Name of factory :Zhongshan Haotong Electrical
Appliances Co., Ltd.
Address of factory:No.3 Sanjiao Section of
Panzhong Highway, Sanjiao Town, Zhongshan,
Guangdong, P.R. China

General product information:


The electric constructions of these models are basically identical. There is no other difference except the
following:

TRF No. IEC60335_2_9M


Page 88 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 89 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 90 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 91 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 92 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 93 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 94 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 95 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 96 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 97 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 98 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 99 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 100 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 101 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 102 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 103 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 104 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 105 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 106 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 107 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 108 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 109 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 110 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 111 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 112 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 113 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 114 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 115 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 116 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 117 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 118 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 119 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 120 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 121 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 122 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 123 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 124 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 125 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 126 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 127 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 128 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 129 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_2_9M


Page 130 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

5 GENERAL CONDITIONS FOR THE TESTS P


Tests performed according to clause 5, e.g. P
nature of supply, sequence of testing, etc.
5.2 See Note (IEC 60335-2-9) N/A
5.3 If it is evident from the construction of the P
appliance that the test of one function will
produce more favourable results than another,
this function is not tested. (IEC 60335-2-9)
5.6 If two or more cooking functions can be P
performed simultaneously, they are tested at
the same time. (IEC 60335-2-9)
5.101 Induction hotplates are operated as specified P
for motor-operated appliances. Other
appliances are tested as specified for heating
appliances, even if they incorporate motors
(IEC 60335-2-9)
In appliances that incorporate induction P
hotplates in addition to other heating elements,
the induction hotplates are operated
simultaneously and supplied separately
(IEC 60335-2-9)
6 CLASSIFICATION P
6.1 Protection against electric shock: Class I P
Class 0, 0I, I, II, III......................................................:
6.2 Protection against harmful ingress of water IPX0 P
Appliances intended for outdoor use shall be at N/A
least IPX4 (IEC 60335-2-9)
7 MARKING AND INSTRUCTIONS P
7.1 Rated voltage or voltage range (V)......................: 220-240V P
Symbol for nature of supply, or................ ...........: ~ P
Rated frequency (Hz)................................... ...........: 50Hz/60Hz P
Rated power input (W), or......................................: 3000W P
Rated current (A) .....................................................: N/A
Manufacturer's or responsible vendor's name, Zhongshan Haotong Electrical P
trademark or identification mark.............. ...........: Appliances Co., Ltd.
Model or type reference.............................. ...........: HK-P55RCL P
Symbol IEC 60417-5172, for class II appliances N/A
IP number, other than IPX0........................ ...........: IPX0 N/A
Symbol IEC 60417-5180, for class III N/A
appliances, unless

TRF No. IEC60335_2_9M


Page 131 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

the appliance is operated by batteries only N/A


Symbol IEC 60417-5018, for class II and class III N/A
appliances incorporating a functional earth
The rated power input or rated current of N/A
induction hotplates shall also be marked.
............................................................ (IEC 60335-2-9)
Appliances intended to be partially immersed N/A
in water for cleaning shall be marked with the
maximum level of immersion and the
substance of the following:
Do not immerse beyond this level
............................................................ (IEC 60335-2-9)
If cookers, portable ovens and rotary grills N/A
have accessible metal surfaces, other than
working surfaces, that have a temperature rise
exceeding 90 K during the test of Clause 11,
they shall be marked with symbol IEC 60417-
5041(2002-10), the rules of ISO 3864-1 applying
except for the specified colours, or with the
substance of the following:
Hot surface...................................... (IEC 60335-2-9)
Symbol IEC 60417-5036, for the enclosure of N/A
electrically-operated water valves in external
hose-sets for connection of an appliance to the
water mains, if the working voltage exceeds
extra-low voltage
7.2 Warning for stationary appliances for multiple N/A
supply
Warning placed in vicinity of terminal cover N/A
7.3 Range of rated values marked with the lower 220-240V P
and upper limits separated by a hyphen
Different rated values marked with the values 50Hz/60Hz P
separated by an oblique stroke
7.4 Appliances adjustable for different rated P
voltages or rated frequencies, the voltage or
the frequencies setting is clearly discernible
Requirement met if frequent changes are not N/A
required and the rated voltage to which the
appliance is to be adjusted is determined from
a wiring diagram
7.5 Appliances with more than one rated voltage or N/A
one or more rated voltage ranges, marked with
rated input or rated current for each rated
voltage or range, unless

TRF No. IEC60335_2_9M


Page 132 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

the power input is related to the arithmetic P


mean value of the rated voltage range
Relation between marking for upper and lower N/A
limits of rated power input or rated current and
voltage is clear
7.6 Correct symbols used P
Symbol for nature of supply placed next to P
rated voltage
Symbol for class II appliances placed unlikely N/A
to be confused with other marking
Units of physical quantities and their symbols P
according to international standardized system
7.7 Connection diagram fixed to appliances to be N/A
connected to more than two supply conductors
and appliances for multiple supply, unless
correct mode of connection is obvious N/A
7.8 Except for type Z attachment, terminals for connection to the supply mains P
indicated as follows:
- marking of terminals exclusively for the N/A
neutral conductor (letter N)
- marking of protective earthing terminals P
(symbol IEC 60417-5019)
- marking of functional earthing terminals N/A
(symbol IEC 60417-5018)
- marking not placed on removable parts P
7.9 Marking or placing of switches which may P
cause a hazard
7.10 Indications of switches on stationary Letters and Indicator P
appliances and controls on all appliances by
use of figures, letters or other visual means.... :
This applies also to switches which are part of P
a control
If figures are used, the off position indicated by N/A
the figure 0
The figure 0 indicates only OFF position, N/A
unless no confusion with the OFF position
7.11 Indication for direction of adjustment of P
controls
7.12 Instructions for safe use provided P

TRF No. IEC60335_2_9M


Page 133 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Details concerning precautions during user P


maintenance
The instructions state that: P
- the appliance is not to be used by persons P
(including children) with reduced physical,
sensory or mental capabilities, or lack of
experience and knowledge, unless they have
been given supervision or instruction
- children being supervised not to play with the P
appliance
For a part of class III construction supplied N/A
from a detachable power supply unit, the
instructions state that the appliance is only to
be used with the unit provided
Instructions for class III appliances state that it N/A
must only be supplied at SELV, unless
it is a battery-operated appliance, the battery N/A
being charged outside the appliance
For appliances for altitudes exceeding 2000 m, N/A
the maximum altitude is stated................. ...........:
The instructions for appliances incorporating a N/A
functional earth states that the appliance
incorporates an earth connection for functional
purposes only
Appliance with inlet and intended to be immersed for cleaning, instruction N/A
sheet including in substance: .............................................................(IEC 60335-2-9)
- remove connector before cleaning N/A
- dry appliance inlet before re-use N/A
The instructions for use for appliances N/A
intended to be used with a connector
incorporating a thermostat shall state that only
the appropriate connector must be used
(IEC 60335-2-9)
Instructions for appliances for outdoor use (IEC 60335-2-9): N/A
-The appliance is suitable for outdoor use N/A
-The supply cord should be regularly examined N/A
for signs of damage, and if the cord is
damages, the appliance must not be used
-The appliance must be supplied through a N/A
residual current device (RDC) having a rated
residual operating current not exceeding 30mA

TRF No. IEC60335_2_9M


Page 134 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

-The appliance is to be connected to a socket- N/A


outlet having an earthing contact (class I)
N/A
If symbol IEC 60417-5041 (2002-10) is marked
on appliances, its meaning shall be explained
(IEC 60335-2-9)
The instructions shall state that the appliances P
are not intended to be operated by means of an
external timer or separate remote-control
system (IEC 60335-2-9)
Instructions for use P
For oven: The temperature of the door or the P
outer surface may be high when the appliance
is operating ................................... (IEC 60335-2-9)
For toaster: Bread may burn. Therefore N/A
toasters must not be used near or below
curtains and other combustible materials. They
must be watched.......................................................
........................................................... (IEC 60335-2-9)
For barbecue: WARNING: Charcoal or similar N/A
combustible fuels must not be used with this
appliance........................................ (IEC 60335-2-9)
For barbecue: Maximum quantity of water to be N/A
poured into the appliance...........(IEC 60335-2-9)
If top surface of a hotplate is of glass-ceramic N/A
or similar material and protects live parts,
warning : If the surface is cracked, switch off
the appliance to avoid the possibility of
electric shock
(IEC 60335-2-9)
For induction hotplates: Metallic objects such N/A
as knives, forks, spoons and lids not be placed
on the hotplate since they can get hot(IEC
60335-2-9).
For breadmakers: maximum quantities of flour N/A
and raising agent that may be used(IEC 60335-
2-9)
The instructions for candy floss appliances N/A
shall state the maximum quantities of sugar
and other ingredients that may be used.(IEC
60335-2-9)
The instructions shall include the substance of the following: (IEC 60335-2-9) P

TRF No. IEC60335_2_9M


Page 135 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

This appliances is intended to be used in Only used in household P


household and similar applications such as:
-staff kitchen areas in shops, offices and
others working environments;
-farm houses;
-by clients in hotels, motels and other
residential type environments;
-bed and breakfast type environments.
Note 101: If the manufacturer wants to limit the N/A
use of the appliance to less than above, this
must be clearly stated in the instructions. (IEC
60335-2-9)
7.12.1 Sufficient details for installation supplied N/A
For an appliance intended to be permanently N/A
connected to the water mains and not
connected by a hose-set, this is stated
7.12.2 Stationary appliances not fitted with means for N/A
disconnection from the supply mains having a
contact separation in all poles that provide full
disconnection under overvoltage category III,
the instructions state that means for
disconnection must be incorporated in the
fixed wiring in accordance with the wiring rules
7.12.3 Insulation of the fixed wiring in contact with N/A
parts exceeding 50 K during clause 11;
instructions state that the fixed wiring must be
protected
7.12.4 Instructions for built-in appliances: N/A
- dimensions of space N/A
- dimensions and position of supporting and N/A
fixing
- minimum distances between parts and N/A
surrounding structure
- minimum dimensions of ventilating openings N/A
and arrangement
- connection to supply mains and N/A
interconnection of separate components
- allow disconnection of the appliance after N/A
installation, by accessible plug or a switch in
the fixed wiring, unless
a switch complying with 24.3 N/A
7.12.5 Replacement cord instructions, type X N/A
attachment with a specially prepared cord

TRF No. IEC60335_2_9M


Page 136 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Replacement cord instructions, type Y P


attachment
Replacement cord instructions, type Z N/A
attachment
7.12.6 Caution in the instructions for appliances N/A
incorporating a non-self-resetting thermal cut-
out that is reset by disconnection of the
supply mains, if this cut-out is required to
comply with the standard
7.12.7 Instructions for fixed appliances stating how N/A
the appliance is to be fixed
7.12.8 Instructions for appliances connected to the water mains: N/A
- max. inlet water pressure (Pa)................ ...........: N/A
- min. inlet water pressure, if necessary (Pa)... : N/A
Instructions concerning new and old hose-sets N/A
for appliances connected to the water mains by
detachable hose-sets
7.13 Instructions and other texts in an official English P
language
7.14 Marking clearly legible and durable, rubbing P
test as specified
The height of the triangle used with symbol IEC P
60417-5041(DB:2002-10) shall be at least 12 20
mm (IEC 60335-2-9)
7.15 Markings on a main part P
Marking clearly discernible from the outside, if P
necessary after removal of a cover
For portable appliances, cover can be removed N/A
or opened without a tool
For stationary appliances, name, trademark or N/A
identification mark and model or type reference
visible after installation
For fixed appliances, name, trademark or N/A
identification mark and model or type reference
visible after installation according to the
instructions
Indications for switches and controls placed on P
or near the components. Marking not on parts
which can be positioned or repositioned in
such a way that the marking is misleading
The symbol IEC 60417-5018 placed next to the N/A
symbol IEC 60417-5172 or IEC 60417-5180

TRF No. IEC60335_2_9M


Page 137 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

The marking specified for hot surfaces shall be P


visible when the appliance is operated as in normal
used including when actuating any switch,
adjusting any control or opening a lid or door. It
shall not be placed on a hot functional surface
(IEC 60335-2-9)
7.16 Marking of a possible replaceable thermal link N/A
or fuse link clearly visible with regard to
replacing the link
8 PROTECTION AGAINST ACCESS TO LIVE PARTS P
8.1 Adequate protection against accidental contact P
with live parts
8.1.1 Requirement applies for all positions, P
detachable parts removed
Lamps behind a detachable cover not removed, P
if conditions met
Insertion or removal of lamps, protection P
against contact with live parts of the lamp cap
Use of test probe B of IEC 61032, with a force P
not exceeding 1 N: no contact with live parts
Use of test probe B of IEC 61032 through P
openings, with a force of 20N: no contact with
live parts
For toasters having a crumb tray : use of test N/A
probe 41 of IEC 61032 : no contact through
crumb tray with live parts that are disconnected
by double pole switch using (IEC 60335-2-9)
8.1.2 Use of test probe 13 of IEC 61032, with a force P
not exceeding 1 N, through openings in class 0
appliances and class II
appliances/constructions: no contact with live
parts
Test probe 13 also applied through openings in P
earthed metal enclosures having a non-
conductive coating: no contact with live parts
8.1.3 For appliances other than class II, use of test N/A
probe 41 of IEC 61032, with a force not
exceeding 1 N: no contact with live parts of
visible glowing heating elements
8.1.4 Accessible part not considered live if: N/A
- safety extra-low a.c. voltage: peak value not N/A
exceeding 42.4 V

TRF No. IEC60335_2_9M


Page 138 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

- safety extra-low d.c. voltage: not exceeding N/A


42.4 V
- or separated from live parts by protective N/A
impedance
If protective impedance: d.c. current not N/A
exceeding 2 mA, and
a.c. peak value not exceeding 0.7 mA N/A
- for peak values over 42.4 V up to and N/A
including 450 V, capacitance not exceeding
0,1 F
- for peak values over 450 V up to and N/A
including 15 kV, discharge not exceeding 45 C
- for peak values over 15kV, the energy in the N/A
discharge not exceeding 350 mJ
8.1.5 Live parts protected at least by basic insulation before installation or N/A
assembly:
- built-in appliances N/A
- fixed appliances N/A
- appliances delivered in separate units N/A
8.2 Class II appliances and constructions P
constructed so that there is adequate
protection against accidental contact with
basic insulation and metal parts separated
from live parts by basic insulation only
Only possible to touch parts separated from P
live parts by double or reinforced insulation
9 STARTING OF MOTOR-OPERATED APPLIANCES N/A
Requirements and tests are specified in part 2 N/A
when necessary
10 POWER INPUT AND CURRENT P
10.1 Power input at normal operating temperature, (see appended table) P
rated voltage and normal operation not
deviating from rated power input by more than
shown in table 1........................................................:
If the power input varies throughout the operating N/A
cycle and the maximum value of the power input
exceeds, by a factor greater than two, the
arithmetic mean value of the power input occurring
during a representative period, the power input is
the maximum value that is exceeded for more than
10 % of the representative period

TRF No. IEC60335_2_9M


Page 139 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Otherwise the power input is the arithmetic N/A


mean value
Test carried out at upper and lower limits of the N/A
ranges for appliances with one or more rated
voltage ranges, unless
the rated power input is related to the P
arithmetic mean value
Power input of induction hotplates measured N/A
separately and the tolerances for motor-
operated appliances apply. (IEC 60335-2-9)
10.2 Current at normal operating temperature, rated (see appended table) N/A
voltage and normal operation not deviating
from rated current by more than shown in table
2.....................................................................................:
If the current varies throughout the operating cycle N/A
and the maximum value of the current exceeds, by
a factor greater than two, the arithmetic mean
value of the current occurring during a
representative period, the current is the maximum
value that is exceeded for more than 10 % of the
representative period
Otherwise the current is the arithmetic mean N/A
value
Test carried out at upper and lower limits of the N/A
ranges for appliances with one or more rated
voltage ranges, unless
the rated current is related to the arithmetic N/A
mean value of the range
Current input of induction hotplates measured N/A
separately and the tolerances for motor-
operated appliances apply (IEC 60335-2-9)
11 HEATING P
11.1 No excessive temperatures in normal use P
Compliance for toasters is also checked by the N/A
test of 11. 101 (IEC 60335-2-
9)
Compliance for ovens, rotary grills and P
cookers is also checked by the test of 11.102.
(IEC 60335-2-9)
Compliance for contact grills, waffle irons, N/A
radiant grills, raclette grills, barbecues, candy
floss appliances and hot plates, is also
checked by the test of 11.103. (IEC 60335-2-9)

TRF No. IEC60335_2_9M


Page 140 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Compliance for breadmakers, pop-corn N/A


makers, and food dehydrators is also checked
by the test of 11.104. (IEC 60335-2-9)
Compliance for roasters is also checked by the N/A
test of 11.105. (IEC 60335-2-9)
11.2 The appliance is held, placed or fixed in P
position as described..............................................:
Radiant grills and raclette grills that are loaded Back near one of the walls of P
from the front, rotary grills, ovens, breadmakers, the test corner and away from
cookers and hotplates are placed with their backs the other wall
as near as possible to one of the walls of the test
corner and away from the other wall (IEC 60335-2-
9)
11.3 Temperature rises, other than of windings, P
determined by thermocouples
Temperature rises of windings determined by N/A
resistance method, unless
the windings are non-uniform or it is difficult to N/A
make the necessary connections
For flat surfaces, temperature rises are measured N/A
using the probe of Figure 105. The probe is
applied with a force of 4 N ± 1 N to the surface in
such a way that the best possible contact between
the probe and the surface is ensured. (IEC
60335-2-9)
11.4 Heating appliances operated under normal 262,3W 3756,5W P
operation at 1.15 times rated power input (W) :
If the temperature rise limits are exceeded in N/A
appliances incorporating motors, transformers or
electronic circuits, and if the power input is lower
than the rated power input, the test is repeated
with the appliance supplied at 1,06 times rated
voltage ............................................ (IEC 60335-2-9)
Breadmakers are operated as specified for N/A
combined appliances. ................. (IEC 60335-2-9)
11.5 Motor- operated appliances operated under N/A
normal operation at most unfavourable voltage
between 0.94 and 1.06 times rated voltage (V).:
11.6 Combined appliances operated under normal N/A
operation at most unfavourable voltage
between 0.94 and 1.06 times rated voltage (V).:
11.7 Tests carried out in compliance with the N/A
paragraphs N° 1 to 11 (IEC 60335-2-9)
11.8 Temperature rises monitored continuously and (see appended table) P
not exceeding the values in table 3 ....................:

TRF No. IEC60335_2_9M


Page 141 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

If the temperature rise of a motor winding N/A


exceeds the value of table 3, or
if there is doubt with regard to classification of N/A
insulation,
tests of Annex C are carried out N/A
Sealing compound does not flow out P
Protective devices do not operate, except P
components in protective electronic circuits N/A
tested for the number of cycles specified in
24.1.4
For radiant grills, rotary grills, raclette grills, N/A
hotplates and cookers, instead of 65 K, the
temperature rise of the wall of the test corner
shall not exceed 75 K. (IEC 60335-2-9)
When an appliance connector incorporates a N/A
thermostat, the temperature rise limit for the
pins of the inlet does not apply (IEC 60335-2-9)
The temperature rise limits of motors, N/A
transformers, components of electronic circuit
and parts directly influenced by them may be
exceeded when the appliance is operated at
1,15 times rated power input (IEC 60335-2-9)
Cheese used in sandwich toasting attachments N/A
doesn’t flow into places where it can give rise
to a hazard, such as reducing clearances or
creepage distances below the values specified
in Clause 29 (IEC 60335-2-9).
The temperature rise limits for touch controls P
also include all surfaces within 5 mm of the
touch controls, regardless of their shape.
(IEC 60335-2-9)

TRF No. IEC60335_2_9M


Page 142 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

11.101 N/A
Toasters are placed as specified in 11.2 and are
operated for three cycles at rated power under
normal operation (IEC 60335-2-9).
During the test, the temperature rise of N/A
surfaces shall not exceed the values specified
in Table 102 (IEC 60335-2-9).
11.102 Ovens, rotary grills and cookers are placed as P
specified in 11.2 and are supplied at rated
power input and operated under normal
operation (IEC 60335-2-9)
Appliances are operated until steady P
conditions are established or for 60 min,
whichever is shorter.
During the test, the temperature rise of
surfaces shall not exceed the values specified
in Table 102.
Ovens having settings higher than 240 °C are P
also operated at the maximum setting until
steady conditions are established or for 60
min, whichever is shorter. The temperature rise
limits of Table 102 for top surfaces and door
surfaces are increased by 10 K.
11.103 Contact grills, waffle irons, radiant grills, N/A
raclette grills, barbecues, candy floss
appliances and hot plates are placed as
specified in 11.2 and are supplied at rated
power input and operated under normal
operation. (IEC 60335-2-9)
During the test, the temperature rise of
surfaces shall not exceed the values specified
in Table 102.
11.104 Breadmakers, pop-corn makers and food N/A
dehydrators are placed as specified in 11.2 and
are supplied at rated power input and operated
under normal operation. (IEC 60335-2-9)
During the test, the temperature rise of
surfaces shall not exceed the values specified
in Table 102.
11.105 Roasters are placed as specified in 11.2 and N/A
are supplied at rated power input and operated
under normal operation. (IEC 60335-2-9)
During the test, the temperature rise of
surfaces shall not exceed the values specified
in Table 102.
13 LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING P
TEMPERATURE
13.1 Leakage current not excessive and electric P
strength adequate

TRF No. IEC60335_2_9M


Page 143 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Heating appliances operated at 1.15 times the 3756,5W P


rated power input (W)..............................................:
Motor- operated appliances and combined N/A
appliances supplied at 1.06 times the rated
voltage (V).................................................................. :
Protective impedance and radio interference N/A
filters disconnected before carrying out the
tests
grill incorporated in oven, oven or grill N/A
operated most unfavourable (IEC 60335-2-9).
Induction wok hotplates are operated with the N/A
wok pan that is supplied by the manufacturer
with the induction wok hotplate at the point of
sale. (IEC 60335-2-9).
13.2 For class 0, class II and class III appliances and P
class II constructions, leakage current
measured by means of the circuit described in
figure 4 of IEC 60990
For class 0I and class I appliances, a low P
impedance ammeter may be used
Leakage current measurements...........................: (see appended table) P
If earthed metal between live parts and surface N/A
of glass-ceramic (or similar) of hotplate,
leakage current between live parts and each of
vessels in turn connected to earthed metal not
exceeding 0,75 mA (IEC 60335-2-9)
If no earthed metal between live parts and N/A
surface of glass-ceramic (or similar) of
hotplate, leakage current between live parts
and each of vessels in turn not exceeding 0,25
mA (IEC 60335-2-
9)
13.3 The appliance is disconnected from the supply P
Electric strength tests according to table 4...... : (see appended table) P
test voltage of 1000V if earthed metal between N/A
live parts and surface of glass-ceramic (or
similar) of hotplate (IEC 60335-2-9).
test voltage of 3000 V if no earthed metal N/A
between live parts and surface of glass-
ceramic (or similar) of hotplate (IEC 60335-2-
9).
No breakdown during the tests P
14 TRANSIENT OVERVOLTAGES N/A

TRF No. IEC60335_2_9M


Page 144 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Appliances withstand the transient over- N/A


voltages to which they may be subjected
Clearances having a value less than specified (see appended table) N/A
in table 16 subjected to an impulse voltage
test, the test voltage specified in table 6........... :
No flashover during the test, unless N/A
of functional insulation if the appliance N/A
complies with clause 19 with the clearance
short-circuited
15 MOISTURE RESISTANCE P
15.1 Enclosure provides the degree of moisture IPX0 N/A
protection according to classification of the
appliance
Compliance checked as specified in 15.1.1, N/A
taking into account 15.1.2, followed by the
electric strength test of 16.3
No trace of water on insulation which can N/A
result in a reduction of clearances or creepage
distances below values specified in clause 29
15.1.1 Appliances, other than IPX0, subjected to tests N/A
as specified in IEC 60529....................................... :
Water valves containing live parts in external N/A
hoses for connection of an appliance to the
water mains tested as specified for IPX7
appliances
15.1.2 Hand-held appliance turned continuously N/A
through the most unfavourable positions
during the test
Built-in appliances installed according to the N/A
instructions
Appliances placed or used on the floor or table N/A
placed on a horizontal unperforated support
Appliances normally fixed to a wall and N/A
appliances with pins for insertion into socket-
outlets are mounted on a wooden board
For IPX3 appliances, the base of wall mounted N/A
appliances is placed at the same level as the
pivot axis of the oscillating tube
For IPX4 appliances, the horizontal centre line N/A
of the appliance is aligned with the pivot axis
of the oscillating tube, and

TRF No. IEC60335_2_9M


Page 145 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

for appliances normally used on the floor or N/A


table, the movement is limited to two times 90
for a period of 5 min, the support being placed
at the level of the pivot axis of the oscillating
tube
Wall-mounted appliances, take into account the N/A
distance to the floor stated in the instructions
Appliances normally fixed to a ceiling are N/A
mounted underneath a horizontal unperforated
support, the pivot axis of the oscillating tube
located at the level of the underside of the
support, and
for IPX4 appliances, the movement of the tube N/A
is limited to two times 90 from the vertical for
a period of 5 min
Appliances with type X attachment fitted with a N/A
flexible cord as described
Detachable parts subjected to the relevant N/A
treatment with the main part
However, if a part has to be removed for user N/A
maintenance and a tool is needed, this part is
not removed
15.2 Spillage of liquid does not affect the electrical P
insulation
Spillage solution comprising water containing P
approximately 1 % NaCl and 0,6 % rinsing
agent
Appliances with type X attachment fitted with a N/A
flexible cord as described
Appliances incorporating an appliance inlet N/A
tested with or without an connector, whichever
is most unfavourable
Detachable parts are removed N/A
Overfilling test with additional amount of the N/A
solution, over a period of 1 min (l)
Overfilling test; quantity : as specified in IEC P
60335-2-9
Ovens: 0.5l (IEC 60335-2-9) P
Hotplates and cookers : 0.5l ,15s N/A
(IEC 60335-2-9)

TRF No. IEC60335_2_9M


Page 146 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

For induction wok hotplates, the test is N/A


performed using the wok pan that is supplied
by the manufacturer with the induction wok
hotplate at the point of sale. (IEC 60335-2-9)
Hotplates incorporate a thermal control : 0.02l N/A
(IEC 60335-2-9)
Hotplates having ventilating opening : 0.2l N/A
(IEC 60335-2-9)
Other appliances : 0.1l/100cm² 1min N/A
(IEC 60335-2-9)
The appliance withstands the electric strength P
test of 16.3
No trace of water on insulation that can result P
in a reduction of clearances or creepage
distances below values specified in clause 29
15.3 Appliances proof against humid conditions P
Checked by test Cab: Damp heat steady state P
in IEC 60068-2-78
Detachable parts removed and subjected, if P
necessary, to the humidity test with the main
part
Humidity test for 48 h in a humidity cabinet P
Reassembly of those parts that may have been P
removed
The appliance withstands the tests of clause 16 P
15.101 Appliances to be immersed in water for cleaning N/A
sufficiently protected against effects of
immersion (IEC 60335-2-9)
Testing conditions and scheduling as specified N/A
No trace of water on insulation which can result N/A
in reduction of creepage distances and
clearance below values specified in 29
16 LEAKAGE CURRENT AND ELECTRIC STRENGTH P
16.1 Leakage current not excessive and electric P
strength adequate
Protective impedance disconnected from live N/A
parts before carrying out the tests
Tests carried out at room temperature and not P
connected to the supply

TRF No. IEC60335_2_9M


Page 147 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

For hotplates, the tests are carried out with a P


vessel as specified for normal operation placed
on each cooking zone (IEC 60335-2-9).
Induction wok hotplates are operated with the N/A
wok pan that is supplied by the manufacturer
with the induction wok hotplate at the point of
sale. (IEC 60335-2-9).
16.2 Single-phase appliances: test voltage 1.06 254,4V P
times rated voltage (V)............................................ :
Three-phase appliances: test voltage 1.06 N/A
times rated voltage divided by 3 (V)..................:
Leakage current measurements...........................: (see appended table) P
Limit values doubled if: N/A
- all controls have an off position in all poles, N/A
or
- the appliance has no control other than a N/A
thermal cut-out, or
- all thermostats, temperature limiters and N/A
energy regulators do not have an off position,
or
- the appliance has radio interference filters N/A
With the radio interference filters (see appended table) N/A
disconnected, the leakage current do not
exceed limits specified........................................... :
If earthed metal between live parts and surface N/A
of glass-ceramic (or similar) of hotplate,
leakage current between live parts and each of
vessels in turn connected to earthed metal not
exceeding 0,75 mA (IEC 60335-2-9)
If no earthed metal between live parts and N/A
surface of glass-ceramic (or similar) of
hotplate, leakage current between live parts
and each of vessels in turn not exceeding 0,25
mA (IEC 60335-2-9)
16.3 Electric strength tests according to table 7...... : (see appended table) P
Test voltage applied between the supply cord (see appended table) P
and inlet bushing and cord guard and cord
anchorage as specified...........................................:
test voltage of 1250 V if earthed metal between N/A
live parts and surface of glass-ceramic (or
similar) of hotplate. (IEC 60335-2-9)

TRF No. IEC60335_2_9M


Page 148 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

test voltage of 3000 V if no earthed metal N/A


between live parts and surface of glass-
ceramic (or similar) of hotplate. (IEC 60335-2-9)
No breakdown during the tests P
17 OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED N/A
CIRCUITS
No excessive temperatures in transformer or (see appended table) N/A
associated circuits in event of short- circuits
likely to occur in normal use.................................:
Appliance supplied with 1.06 or 0.94 times N/A
rated voltage under the most unfavourable
short-circuit or overload likely to occur in
normal use (V)........................................................... :
Basic insulation is not short-circuited N/A
Temperature rise of insulation of the N/A
conductors of safety extra-low voltage circuits
not exceeding the relevant value specified in
table 3 by more than 15 K
Temperature of the winding not exceeding the P
value specified in table 8
However, limits do not apply to fail-safe N/A
transformers complying with sub-clause 15.5
of IEC 61558-1
18 ENDURANCE N/A
Requirements and tests are specified in part 2 N/A
when necessary
19 ABNORMAL OPERATION P
19.1 The risk of fire, mechanical damage or electric P
shock under abnormal or careless operation
obviated
Electronic circuits so designed and applied N/A
that a fault will not render the appliance unsafe
.......................................................................................:
Appliances incorporating heating elements P
subjected to the tests of 19.2 and 19.3, and
if the appliance also has a control that limit the P
temperature during clause 11 it is subjected to
the test of 19.4, and
if applicable, to the test of 19.5 P
Appliances incorporating PTC heating N/A
elements are also subjected to the test of 19.6

TRF No. IEC60335_2_9M


Page 149 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Appliances incorporating motors subjected to P


the tests of 19.7 to 19.10, as applicable
Appliances incorporating electronic circuits N/A
subjected to the tests of 19.11 and 19.12, as
applicable
Appliances incorporating contactors or relays N/A
subjected to the test of 19.14, being carried out
before the tests of 19.11
Appliances incorporating voltage selector N/A
switches subjected to the test of 19.15
Unless otherwise specified, the tests are P
continued until a non-self-resetting thermal
cut-out operates, or
until steady conditions are established P
If a heating element or intentionally weak part N/A
becomes open-circuited, the relevant test is
repeated on a second sample
Tests of 19.4 and 19.5 are only applicable to: P
-breadmakers, contact grills, food dehydrators
- ovens, roasters, hotplates, cookers, rotary
grills if they incorporate a timer or if their
instructions indicate a cooking operation
longer than 1h
(IEC 60335-2-9)
Toasters are subjected to the tests 19.101 and N/A
19.102 (IEC 60335-2-9)
However, induction wok hotplates are not N/A
subjected to the test of 19.104. (IEC 60335-2-9)
Induction hotplates are subjected to the tests N/A
19.103 and 19.104 (IEC 60335-2-9)
19.2 Test of appliances with heating elements with 206,7V 2333,0W P
restricted heat dissipation; test voltage (V),
power input of 0.85 times rated power input (W)
.......................................................................................:
Radiant grills, raclette grills that are loaded P
from the front , rotary grills, ovens, hotplates
and cookers are placed as near as possible to
the walls of the test corner..........(IEC 60335-2-9)
They are tested empty with lids open or closed P
whichever is the more unfavourable
............................................................ (IEC 60335-2-9)

TRF No. IEC60335_2_9M


Page 150 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Hotplates are operated without a vessel and N/A


with the controls adjusted to the highest setting
(IEC 60335-2-9)
Induction hotplates are operated under N/A
conditions of clause 11 but with empty vessels,
controls adjusted to the highest setting(IEC
60335-2-9)
Cookers are only tested with the heating unit N/A
that results in the most unfavourable
conditions, their controls adjusted to the
highest setting. However ovens are operated if
they do not have an indicating lamp to show
when they are switched on, controls adjusted to
the highest setting (IEC 60335-2-9)
Induction wok hotplates are operated with an N/A
empty wok pan that is supplied by the
manufacturer with the induction wok hotplate
at the point of sale. (IEC 60335-2-9)
19.3 Test of 19.2 repeated; test voltage (V), power 267,4V 4050,5W P
input of 1.24 times rated power input (W)......... :
19.4 Test conditions as in clause 11, any control 262,3W 3756,5W P
limiting the temperature during tests of
clause 11 short- circuited
Air-circulating fans of food dehydrators N/A
disconnected (IEC 60335-2-9)
19.5 Test of 19.4 repeated on Class 0I and I P
appliances with tubular sheathed or embedded
heating elements. No short-circuiting, but one
end of the element connected to the sheath
The test repeated with reversed polarity and P
the other end of the heating element connected
to the sheath
The test is not carried out on appliances N/A
intended to be permanently connected to fixed
wiring and on appliances where an all-pole
disconnection occurs during the test of 19.4
19.6 Appliances with PTC heating elements tested N/A
at rated voltage, establishing steady conditions
The working voltage of the PTC heating N/A
element is increased by 5% and the appliance
is operated until steady conditions are re-
established. The voltage is then increased in
similar steps until 1.5 times working voltage or
until the PTC heating element ruptures (V).......:

TRF No. IEC60335_2_9M


Page 151 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

19.7 Stalling test by locking the rotor if the locked P


rotor torque is smaller than the full load torque,
or
locking moving parts of other appliances P
Locked rotor, capacitors open-circuited one at P
a time
Test repeated with capacitors short-circuited P
one at a time, unless
capacitor is of class P2 of IEC 60252-1 N/A
Appliances with timer or programmer supplied N/A
with rated voltage for each of the tests, for a
period equal to the maximum period allowed.. :
An electronic timer or programmer that P
operates to ensure compliance with the test
before the maximum period under the
conditions of Clause 11 is reached, is a
protective electronic circuit
Other appliances supplied with rated voltage N/A
for a period as specified.........................................:
Winding temperatures not exceeding values (see appended table) P
specified in table 8................................................... :
19.8 Multi- phase motors operated at rated voltage N/A
with one phase disconnected
19.9 Running overload test on appliances N/A
incorporating motors intended to be remotely
or automatically controlled or liable to be
operated continuously
Motor-operated and combined appliances for N/A
which 30.2.3 is applicable and that use
overload protective devices relying on
electronic circuits to protect the motor
windings, are also subjected to the test
Winding temperatures not exceeding values as N/A
specified..................................................................... :
19.10 Series motor operated at 1.3 times rated N/A
voltage for 1 min (V)................................................ :
During the test, parts not being ejected from N/A
the appliance
19.11 Electronic circuits, compliance checked by N/A
evaluation of the fault conditions specified in
19.11.2 for all circuits or parts of circuits,
unless

TRF No. IEC60335_2_9M


Page 152 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

they comply with the conditions specified in N/A


19.11.1
Appliances incorporating an electronic circuit N/A
that relies upon a programmable component to
function correctly, subjected to the test of
19.11.4.8, unless
restarting does not result in a hazard N/A
Appliances having a device with an off position N/A
obtained by electronic disconnection, or a
device placing the appliance in a stand-by
mode, subjected to the tests of 19.11.4
If the safety of the appliance under any of the N/A
fault conditions depends on the operation of a
miniature fuse-link complying with IEC 60127,
the test of 19.12 is carried out
During and after each test the following is checked: N/A
- the temperature of the windings do not N/A
exceed the values specified in table 8
- the appliance complies with the conditions N/A
specified in 19.13
- any current flowing through protective N/A
impedance not exceeding the limits specified
in 8.1.4
If a conductor of a printed board becomes open-circuited, the appliance is N/A
considered to have withstood the particular test, provided both of the
following conditions are met:
- the base material of the printed circuit board N/A
withstands the test of Annex E
- any loosened conductor does not reduce N/A
clearance or creepage distances between live
parts and accessible metal parts below the
values specified in clause 29
19.11.1 Fault conditions a) to g) in 19.11.2 are not applied to circuits or parts of N/A
circuits meeting both of the following conditions:
- the electronic circuit is a low-power circuit, N/A
that is, the maximum power at low-power
points does not exceed 15 W according to the
tests specified
- the protection against electric shock, fire N/A
hazard, mechanical hazard or dangerous
malfunction of other parts of the appliance
does not rely on the correct functioning of the
electronic circuit

TRF No. IEC60335_2_9M


Page 153 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

19.11.2 Fault conditions applied one at a time, the appliance operating under N/A
conditions specified in clause 11, but supplied at rated voltage, duration of
the tests as specified:
a) short circuit of functional insulation if N/A
clearances or creepage distances are less than
the values specified in clause 29
b) open circuit at the terminals of any N/A
component
c) short circuit of capacitors, unless N/A
they comply with IEC 60384-14 N/A
d) short circuit of any two terminals of an N/A
electronic component, other than integrated
circuits
This fault condition is not applied between the N/A
two circuits of an optocoupler
e) failure of triacs in the diode mode N/A
f) failure of microprocessors and integrated N/A
circuits
g) failure of an electronic power switching N/A
device
Each low power circuit is short-circuited by N/A
connecting the low-power point to the pole of
the supply source from which the
measurements were made
19.11.3 If the appliance incorporates a protective N/A
electronic circuit which operates to ensure
compliance with clause 19, the relevant test is
repeated with a single fault simulated, as
indicated in a) to g) of 19.11.2
19.11.4 Appliances having a device with an off position N/A
obtained by electronic disconnection, or
a device that can be placed in the stand-by N/A
mode,
subjected to the tests of 19.11.4.1 to 19.11.4.7, N/A
the device being set in the off position or in the
stand-by mode
Appliances incorporating a protective N/A
electronic circuit subjected to the tests of
19.11.4.1 to 19.11.4.7, the tests being carried
out after the protective electronic circuit has
operated, except that

TRF No. IEC60335_2_9M


Page 154 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

appliances operated for 30 s or 5 min during N/A


the test of 19.7 are not subjected to the tests
for electromagnetic phenomena.
Surge protective devices disconnected, unless N/A
They incorporate spark gaps N/A
19.11.4.1 The appliance is subjected to electrostatic N/A
discharges in accordance with IEC 61000-4-2,
test level 4
19.11.4.2 The appliance is subjected to radiated fields in N/A
accordance with IEC 61000-4-3, test level 3
19.11.4.3 The appliance is subjected to fast transient N/A
bursts in accordance with IEC 61000-4-4, test
level 3 or 4 as specified
19.11.4.4 The power supply terminals of the appliance N/A
subjected to voltage surges in accordance with
IEC 61000-4-5, test level 3 or 4 as specified
An open circuit test voltage of 2 kV is N/A
applicable for the line-to-line coupling mode
An open circuit test voltage of 4 kV is N/A
applicable for the line-to-earth coupling
Earthed heating elements in class I appliances N/A
disconnected
19.11.4.5 The appliance is subjected to injected currents N/A
in accordance with IEC 61000-4-6, test level 3
19.11.4.6 Appliances having a rated current not N/A
exceeding 16 A are subjected to the Class 3
voltage dips and interruptions in accordance
with IEC 61000-4-11
Appliances having a rated current exceeding N/A
16 A are subjected to the Class 3 voltage dips
and interruptions in accordance with IEC
61000-4-34
19.11.4.7 The appliance is subjected to mains signals in N/A
accordance with IEC 61000-4-13, test level
class 2
19.11.4.8 The appliance is supplied at rated voltage and N/A
operated under normal operation. After 60s the
power supply is reduced to a level such that
the appliance ceases to respond or parts
controlled by the programmable component
cease to operate
The appliance continues to operate normally, N/A
or

TRF No. IEC60335_2_9M


Page 155 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

requires a manual operation to restart N/A


19.12 If the safety of the appliance for any of the fault N/A
conditions specified in 19.11.2 depends on the
operation of a miniature fuse-link complying
with IEC 60127, the test is repeated, measuring
the current flowing through the fuse-link;
measured current (A); rated current of the fuse-
link (A)......................................................................... :
19.13 During the tests the appliance does not emit P
flames, molten metal, poisonous or ignitable
gas in hazardous amounts
Temperature rises not exceeding the values (see appended table) P
shown in table 9........................................................:
Compliance with clause 8 not impaired P
If the appliance can still be operated it N/A
complies with 20.2
Insulation, other than of class III appliances or class III constructions that do P
not contain live parts, withstands the electric strength test of 16.3, the test
voltage as specified in table 4:
- basic insulation (V)................................................: 1000V P
- supplementary insulation (V)............................. : 1750V P
- reinforced insulation (V)...................................... : 3000V P
After operation or interruption of a control, N/A
clearances and creepage distances across the
functional insulation withstand the electric
strength test of 16.3, the test voltage being
twice the working voltage
The appliance does not undergo a dangerous P
malfunction, and
no failure of protective electronic circuits, if the P
appliance is still operable
Appliances tested with an electronic switch in the off position, or in the stand- N/A
by mode:
- do not become operational, or P
- if they become operational, do not result in a N/A
dangerous malfunction during or after the tests
of 19.11.4
If the appliance contains lids or doors that are controlled by one or more N/A
interlocks, one of the interlocks may be released provided that:
- the lid or door does not move automatically to N/A
an open position when the interlock is
released, and

TRF No. IEC60335_2_9M


Page 156 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

- the appliance does not start after the cycle in N/A


which the interlock was released
During the test of 19.102 any flame or smoke N/A
from the bread are ignored (IEC 60335-2-9)
Temperature rise of the windings of induction N/A
hotplates not exceeding the values specified in
19.7 (IEC 60335-2-9)
19.14 Appliances operated under the conditions of N/A
clause 11, any contactor or relay contact
operating under the conditions of clause 11
being short-circuited
For a relay or contactor with more than one N/A
contact, all contacts are short-circuited at the
same time
A relay or contactor operating only to ensure N/A
the appliance is energized for normal use is not
short-circuited
If more than one relay or contactor operates in N/A
clause 11, they are short-circuited in turn
19.15 For appliances with a mains voltage selector N/A
switch, the switch is set to the lowest rated
voltage position and the highest value of rated
voltage is applied
19.101 Toasters operated at rated power input and N/A
under normal operation, but without bread, for
six cycles of operation, test repeated 500 times

(IEC 60335-2-9)
The mechanism operates satisfactorily and no N/A
sustained arcing occurs. (IEC 60335-2-9)
19.102 Toasters: test with the ejector mechanism N/A
locked (IEC 60335-2-9)
19.103 Toasters, loaded with the bread specified for N/A
normal operation, are operated at rated power
input for 2 cycles with the control at maximum
setting. The bread is not replaced.
(IEC 60335-2-9)
19.104 Induction hotplates are supplied at rated N/A
voltage and operated with a steel disk
placed on the centre of the cooking zone. The
disk has a thickness of 6 mm and the smallest
diameter, rounded up to the nearest
centimetre, which allows the appliance to
operate.
(IEC 60335-2-9).

TRF No. IEC60335_2_9M


Page 157 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

19.105 Induction hotplates operated with thermal N/A


controls short-circuited or rendered
inoperative in turn: The temperature rise of the
oil shall not exceed 270 K (IEC 60335-2-9).
19.106 Pop-corn makers: operated under conditions N/A
of clause 11 for a period of 5 min but with the
popcorn outlet blocked by means of a grid with
a mesh size small enough to keep the popcorn
from being ejected from the appliance
(IEC 60335-2-9)
20 STABILITY AND MECHANICAL HAZARDS P
20.1 Appliances having adequate stability P
Tilting test through an angle of 10, appliance P
placed on an inclined plane/horizontal support,
not connected to the supply mains; appliance
does not overturn
Tilting test repeated on appliances with heating P
elements, angle of inclination increased to 15
Possible heating test in overturned position; N/A
temperature rise does not exceed values
shown in table 9
20.2 Moving parts adequately arranged or enclosed P
as to provide protection against personal injury
Protective enclosures, guards and similar parts P
are non-detachable, and
have adequate mechanical strength P
Enclosures that can be opened by overriding N/A
an interlock are considered to be detachable
parts
Self- resetting thermal cut- outs and N/A
overcurrent protective devices not causing a
hazard by unexpected closure
Not possible to touch dangerous moving parts N/A
with the test probe described
20.101 Oven with horizontal hinged door: successful P
tilting test in conditions as specified, if relevant
(weight of 3,5 kg) (IEC 60335-2-9).
21 MECHANICAL STRENGTH P
21.1 Appliance has adequate mechanical strength P
and is constructed as to withstand rough
handling

TRF No. IEC60335_2_9M


Page 158 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Checked by applying 3 blows to every point of (see appended table) P


the enclosure like to be weak, in accordance
with test Ehb of IEC 60068-2-75, spring hammer
test, with an impact energy of 0,5 J
The appliance shows no damage impairing P
compliance with this standard, and
compliance with 8.1, 15.1 and clause 29 not P
impaired
If doubt, supplementary or reinforced N/A
insulation subjected to the electric strength
test of 16.3
If necessary, repetition of groups of three N/A
blows on a new sample
For appliances intended for outdoor use, the N/A
impact energy is 0.7J (IEC 60335-2-9)
Appliances incorporates visibly glowing N/A
heating elements located at the top of the oven
and accessible to the test probe 41 of IEC
61032 (IEC 60335-2-9)
For hotplates with surfaces of glass-ceramic or N/A
similar, three blows applied to parts surfaces
not exposed to the test of 21.101, impact
energy 0,70J ± 0,05 J. (IEC 60335-2-9).
21.2 Accessible parts of solid insulation having P
strength to prevent penetration by sharp
implements
Test not applicable if the thickness of P
supplementary insulation is at least 1 mm and
reinforced insulation at least 2 mm
The insulation is tested as specified, and does N/A
withstand the electric strength test of 16.3

TRF No. IEC60335_2_9M


Page 159 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

21.101 Surfaces of hotplates of glass-ceramic or N/A


similar material withstand the stresses liable to
occur in normal use, under test conditions as
specified (IEC 60335-2-9).
Induction wok hotplates are tested with a wok N/A
pan that is supplied by the manufacturer with
the induction wok hotplate at the point of sale.
The wok pan is filled with sand or shot so that
the total mass, including the mass of the wok
pan, is equal to 1,8 kg ± 0,01 kg. (IEC
60335-2-9)
After the tests, surface of hotplate not broken). P
Withstand dielectric strength test of 16.3 P
22 CONSTRUCTION P
22.1 Appliance marked with the first numeral of the IPX0 N/A
IP system, relevant requirements of IEC 60529
are fulfilled
22.2 Stationary appliance: means to ensure all-pole disconnection from the supply N/A
being provided:
- a supply cord fitted with a plug, or N/A
- a switch complying with 24.3, or N/A
- a statement in the instruction sheet that a N/A
disconnection incorporated in the fixed wiring
is to be provided, or
- an appliance inlet N/A
Singe-pole switches and single-pole protective N/A
devices for the disconnection of heating
elements in single-phase, permanently
connected class 01 and class I appliances,
connected to the phase conductor
22.3 Appliance provided with pins: no undue strain N/A
on socket-outlets
Applied torque not exceeding 0.25 Nm N/A
Pull force of 50N to each pin after the appliance N/A
has being placed in the heating cabinet; when
cooled to room temperature the pins are not
displaced by more than 1mm
Each pin subjected to a torque of 0.4Nm; the N/A
pins are not rotating, unless
rotating does not impair compliance with this N/A
standard

TRF No. IEC60335_2_9M


Page 160 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

22.4 Appliance for heating liquids and appliance N/A


causing undue vibration not provided with pins
for insertion into socket-outlets
22.5 No risk of electric shock when touching the P
pins of the plug, for appliances having a
capacitor with rated capacitance exceeding
equal to or greater than 0,1F, the appliance
being disconnected from the supply at the
instant of voltage peak
If compliance relies on the operation of an N/A
electronic circuit, the electromagnetic
phenomena tests of 19.11.4.3 and 19.11.4.4 are
applied
The discharge test is then repeated three N/A
times, voltage not exceeding 34 V (V)................ :
Voltage not exceeding 34 V (V).............................: →0V P
22.6 Electrical insulation not affected by N/A
condensing water or leaking liquid
Electrical insulation of Class II appliances not N/A
affected if a hose ruptures or seal leaks
In case of doubt, test as described N/A
22.7 Adequate safeguards against the risk of N/A
excessive pressure in appliances containing
liquid or gases or having steam-producing
devices
22.8 Electrical connections not subject to pulling N/A
during cleaning of compartments to which
access can be gained without the aid of a tool,
and that are likely to be cleaned in normal use
22.9 Insulation, internal wiring, windings, P
commutators and slip rings not exposed to oil,
grease or similar substances, unless
the substance has adequate insulating N/A
properties
22.10 Not possible to reset voltage-maintained non- N/A
self-resetting thermal cut-outs by the operation
of an automatic switching device incorporated
within the appliance, if:
- a non-self-resetting thermal cut-out is N/A
required by the standard, and
- a voltage maintained non-self-resetting N/A
thermal cut-out is used to meet it

TRF No. IEC60335_2_9M


Page 161 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Non-self-resetting thermal motor protectors N/A


have a trip-free action, unless
they are voltage maintained N/A
Reset buttons of non-self-resetting controls so N/A
located or protected that accidental resetting is
unlikely
22.11 Reliable fixing of non-detachable parts that P
provide the necessary degree of protection
against electric shock, moisture or contact with
moving parts
Obvious locked position of snap-in devices P
used for fixing such parts
No deterioration of the fixing properties of P
snap-in devices used in parts that are likely to
be removed during installation or servicing
Tests as described P
22.12 Handles, knobs etc. fixed in a reliable manner P
Fixing in wrong position of handles, knobs etc. P
indicating position of switches or similar
components not possible
Axial force 15 N applied to parts, the shape N/A
being so that an axial pull is unlikely to be
applied
Axial force 30 N applied to parts, the shape P
being so that an axial pull is likely to be applied
22.13 Unlikely that handles, when gripped as in P
normal use, make the operator’s hand touch
parts having a temperature rise exceeding the
value specified for handles which are held for
short periods only
22.14 No ragged or sharp edges creating a hazard for P
the user in normal use, or during user
maintenance
No exposed pointed ends of self-tapping P
screws or other fasteners, likely to be touched
by the user in normal use or during user
maintenance
22.15 Storage hooks and the like for flexible cords N/A
smooth and well rounded
22.16 Automatic cord reels cause no undue abrasion N/A
or damage to the sheath of the flexible cord, no
breakage of conductors strands and no undue
wear of contacts

TRF No. IEC60335_2_9M


Page 162 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Cord reel tested with 6000 operations, as N/A


specified
Electric strength test of 16.3, voltage of 1000 V N/A
applied
22.17 Spacers not removable from the outside by N/A
hand or by means of a screwdriver or a
spanner
22.18 Current-carrying parts and other metal parts P
resistant to corrosion
22.19 Driving belts not relied upon to provide the N/A
required level of insulation, unless
constructed to prevent inappropriate N/A
replacement
22.20 Direct contact between live parts and thermal P
insulation effectively prevented, unless
material used is non-corrosive, non- P
hygroscopic and non-combustible
22.21 Wood, cotton, silk, ordinary paper and fibrous P
or hygroscopic material not used as insulation,
unless
impregnated N/A
This requirement does not apply to magnesium N/A
oxide and mineral ceramic fibres used for the
electrical insulation of heating elements
22.22 Appliances not containing asbestos P
22.23 Oils containing polychlorinated biphenyl (PCB) P
not used
22.24 Bare heating elements, except in class III P
appliances or class III constructions that do
not contain live parts, adequately supported
Heating elements constructed or supported so P
they are unlikely to become displaced in
normal use. (IEC 60335-2-9)
In case of rupture, the heating conductor is P
unlikely to come in contact with accessible
metal parts
22.25 Sagging heating conductors, except in class III N/A
appliances or class III constructions that do
not contain live parts, cannot come into
contact with accessible metal parts

TRF No. IEC60335_2_9M


Page 163 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

22.26 For class III constructions the insulation N/A


between parts operating at safety extra-low
voltage and other live parts complies with the
requirements for double or reinforced
insulation
22.27 Parts connected by protective impedance N/A
separated by double or reinforced insulation
22.28 Metal parts of Class II appliances conductively N/A
connected to gas pipes or in contact with
water, separated from live parts by double or
reinforced insulation
22.29 Class II appliances permanently connected to N/A
fixed wiring so constructed that the required
degree of access to live parts is maintained
after installation
22.30 Parts serving as supplementary or reinforced P
insulation fixed so that they cannot be
removed without being seriously damaged, or
so constructed that they cannot be replaced in P
an incorrect position, and so that if they are
omitted, the appliance is rendered inoperable
or manifestly incomplete
22.31 Neither clearances nor creepage distances P
over supplementary and reinforced insulation
reduced below values specified in clause 29 as
a result of wear
Neither clearances nor creepage distances P
between live parts and accessible parts
reduced below values for supplementary
insulation if wires, screws etc. become loose
22.32 Supplementary and reinforced insulation P
constructed or protected against pollution so
that clearances or creepage distances are not
reduced below the values in clause 29
Supplementary insulation of natural or N/A
synthetic rubber resistant to ageing, or
arranged and dimensioned so that creepage
distances are not reduced below values
specified in 29.2
Ceramic material not tightly sintered, similar N/A
materials or beads alone not used as
supplementary or reinforced insulation
Insulating Ceramic and similar porous material in N/A
which heating conductors are embedded is
considered to be basic insulation, not
reinforced insulation

TRF No. IEC60335_2_9M


Page 164 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Oxygen bomb test at 70 C for 96 h and 16 h at N/A


room temperature
22.33 Conductive liquids that are or may become N/A
accessible in normal use and conductive
liquids that are in contact with unearthed
accessible metal parts are not in direct contact
with live parts, or
unearthed metal parts separated from live parts N/A
by basic insulation only
Electrodes not used for heating liquids N/A
For class II constructions, conductive liquids N/A
that are or may become accessible in normal
use and conductive liquids that are in contact
with unearthed accessible metal parts, not in
direct contact with basic or reinforced
insulation, unless
the reinforced insulation consists of at least 3 N/A
layers
For class II constructions, conductive liquids N/A
which are in contact with live parts, not in
direct contact with reinforced insulation,
unless
the reinforced insulation consists of at least 3 N/A
layers
An air layer not used as basic or N/A
supplementary insulation in a double
insulation system if likely to be bridged by
leaking liquid
22.34 Shafts of operating knobs, handles, levers etc. P
not live, unless
the shaft is not accessible when the part is N/A
removed
22.35 For other than class III constructions, handles, P
levers and knobs, held or actuated in normal
use, not becoming live in the event of a failure
of basic insulation
Such parts being of metal, and their shafts or N/A
fixings are likely to become live in the event of
a failure of basic insulation, are either
adequately covered by insulation material or
their accessible parts are separated from their
shafts or fixings by supplementary insulation

TRF No. IEC60335_2_9M


Page 165 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

This requirement does not apply to handles, N/A


levers and knobs on stationary appliances and
cordless appliances, other than those of
electrical components, provided they are
reliably connected to an earthing terminal or
earthing contact, or separated from live parts
by earthed metal
Insulating material covering metal handles, N/A
levers and knobs withstand the electric
strength test of 16.3 for supplementary
insulation
22.36 For appliances other than class III, handles N/A
continuously held in the hand in normal use so
constructed that when gripped as in normal
use, the operators hand is not likely to touch
metal parts, unless
they are separated from live parts by double or N/A
reinforced insulation
22.37 Capacitors in Class II appliances not N/A
connected to accessible metal parts and their
casings, if of metal, separated from accessible
metal parts by supplementary insulation,
unless
the capacitors comply with 22.42 N/A
22.38 Capacitors not connected between the N/A
contacts of a thermal cut-out
22.39 Lamp holders used only for the connection of N/A
lamps
22.40 Motor-operated appliances and combined N/A
appliances intended to be moved while in
operation, or having accessible moving parts,
fitted with a switch to control the motor. The
actuating member of the switch being easily
visible and accessible
If the appliance cannot operate continuously, N/A
automatically or remotely without giving rise to
a hazard, appliances for remote operation
being fitted with a switch for stopping the
operation. The actuating member of the switch
being easily visible and accessible
22.41 No components, other than lamps, containing P
mercury
22.42 Protective impedance consisting of at least two N/A
separate components

TRF No. IEC60335_2_9M


Page 166 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Values specified in 8.1.4 not exceeded if any N/A


one of the components are short-circuited or
open-circuited
Resistors checked by the test of 14.1 a) in IEC N/A
60065
Capacitors checked by the tests for class Y N/A
capacitors in IEC 60384-14
22.43 Appliances adjustable for different voltages, N/A
accidental changing of the setting of the
voltage unlikely to occur
22.44 Appliances not having an enclosure that is P
shaped or decorated like a toy
22.45 When air is used as reinforced insulation, P
clearances not reduced below the values
specified in 29.1.3 due to deformation as a
result of an external force applied to the
enclosure
22.46 For programmable protective electronic N/A
circuits used to ensure compliance with the
standard, the software contains measures to
control the fault/error conditions in table R.1
Software that contains measures to control the N/A
fault/error conditions specified in table R.2 is to
be specified in parts 2 for particular
constructions or to address specific hazards
These requirements are not applicable to N/A
software used for functional purpose or
compliance with clause 11
22.47 Appliances connected to the water mains N/A
withstand the water pressure expected in
normal use
No leakage from any part, including any inlet N/A
water hose
22.48 Appliances connected to the water mains N/A
constructed to prevent backsiphonage of non-
potable water
22.49 For remote operation, the duration of operation N/A
is to be set before the appliance can be started,
unless
the appliance switches off automatically or can N/A
operate continuously without hazard
22.50 Controls incorporated in the appliance take N/A
priority over controls actuated by remote
operation

TRF No. IEC60335_2_9M


Page 167 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

22.51 There is a control on the appliance manually N/A


adjusted to the setting for remote operation
before the appliance can be operated in this
mode
There is a visual indication showing that the N/A
appliance is adjusted for remote operation
These requirements not necessary on appliances that can operate as follows, N/A
without giving rise to a hazard:
- continuously, or N/A
- automatically, or N/A
- remotely N/A
22.52 Socket-outlets on appliances accessible to the N/A
user in accordance with the socket-outlet
system used in the country in which the
appliance is sold
22.53 Class II appliances and class III appliances that N/A
incorporate functionally earthed parts have at
least double insulation or reinforced insulation
between live parts and the functionally earthed
parts
22.54 Button cells and batteries designated R1 not N/A
accessible without the aid of a tool, unless
the cover of their compartment can only be N/A
opened after at least two independent
movements have been applied simultaneously

TRF No. IEC60335_2_9M


Page 168 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

22.101 Radiant grills: no timer that is intended to delay N/A


the operation of a heating element,
(IEC 60335-2-9)
Unless having a thermostat and being N/A
incorporated in an oven or other compartment,
(IEC 60335-2-9)
Hotplates shall not incorporate a timer that is N/A
intended to delay the operation of a heating
element. (IEC 60335-2-9)
22.102 Barbecue shall not be provided with bare N/A
heating elements (IEC 60335-2-9)
Oven: heating elements with bare conductors N/A
at the top only (IEC 60335-2-9)
22.103 Oven vents constructed so that moisture or P
grease cannot reduce the clearances and
creepage distances. (IEC 60335-2-9)
22.104 Ovens constructed so that shelves can easily P
slide in the supports and do not fall out of
position when the sides are displaced as much
as possible. (IEC 60335-2-9)
22.105 Appliances have not openings on the P
underside that would allow small items to
penetrate and touch live parts. (IEC 60335-2-9)
Distance measured between the supporting P
surface and live parts through openings
(IEC 60335-2-9)
Distance requested as specified:(IEC 60335-2- P
9)

TRF No. IEC60335_2_9M


Page 169 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

22.106 Grills and barbecues constructed so that their N/A


heating elements are fixed in position or
prevented from operating when they are not in
their normal position of use. (IEC 60335-2-9)
22.107 Hotplate constructed so that heating elements N/A
are prevented from rotating about a vertical
axis and are adequately supported in all
positions of adjustment of their supports.
(IEC 60335-2-9)
22.108 Hotplate constructed so that inadvertent N/A
operation of touch controls is unlikely if this
could give rise to a hazardous situation due to
spillage of liquids or damp cloth placed on the
control panel, and complies with test as
specified........................................ (IEC 60335-2-9)
22.109 Hotplate incorporating touch controls N/A
constructed so that at least two manual
operations are requested to switch on a
heating element but only one to switch it off.
......................................................... (IEC 60335-2-9)
22.110 Induction hotplates constructed so that they N/A
can only be operated with a suitable vessel
placed on the cooking zone.... (IEC 60335-2-9)
Temperature rise of iron not exceeding 35K.... N/A
......................................................... (IEC 60335-2-9)
22.111 Heating element in breadmakers located so N/A
they are not exposed to dough that they may
rise over the edge of the dough container
during normal use of the appliance....................
......................................................... (IEC 60335-2-9)
22.112 Reconnection of the power supply to a N/A
breadmaker after an interruption shall not
result in a fire due to an extended heating
period............................................. (IEC 60335-2-9)
All batteries are removed and the breadmaker N/A
is supplied at rated voltage and operated in
heating mode without load.......(IEC 60335-2-9)
The appliance shall eventually require a N/A
manual operation to restart it.. (IEC 60335-2-9)
22.113 Toasters having an ejector mechanism shall be N/A
constructed so that they switch off
automatically after the normal toasting time
even if the ejector mechanism is blocked by
the bread. (IEC 60335-2-9)

TRF No. IEC60335_2_9M


Page 170 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

22.114 Heating elements in candy floss appliances N/A


shall be located so that they are not exposed to
sugar during normal use of the appliance.
(IEC 60335-2-9)
22.115 For appliances incorporating a hotplate with at N/A
least one heating unit controlled by an
electronic circuit, safety shall not be impaired
in the event of a fault in the electronic circuit.
(IEC 60335-2-9)
23 INTERNAL WIRING P
23.1 Wireways smooth and free from sharp edges P
Wires protected against contact with burrs, P
cooling fins etc.
Wire holes in metal well-rounded or provided P
with bushings
Wiring effectively prevented from coming into P
contact with moving parts
23.2 Beads etc. on live wires cannot change their N/A
position, and are not resting on sharp edges
Beads inside flexible metal conduits contained N/A
within an insulating sleeve
23.3 Electrical connections and internal conductors N/A
movable relatively to each other not exposed to
undue stress
Flexible metallic tubes not causing damage to N/A
insulation of conductors
Open-coil springs not used N/A
Adequate insulating lining provided inside a N/A
coiled spring, the turns of which touch one
another
No damage after 10 000 flexings for conductors N/A
flexed during normal use, or
100 flexings for conductors flexed during user N/A
maintenance
Electric strength test of 16.3, 1000 V between N/A
live parts and accessible metal parts
Not more than 10% of the strands of any N/A
conductor broken, and
not more than 30% for wiring supplying circuits N/A
that consume no more than 15W

TRF No. IEC60335_2_9M


Page 171 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Appliance with 2 stop positions: 10000 flexings N/A


made with moving part fully opened
(IEC 60335-2-9)
23.4 Bare internal wiring sufficiently rigid and fixed N/A
23.5 The insulation of internal wiring subjected to P
the supply mains voltage withstanding the
electrical stress likely to occur in normal use
Basic insulation electrically equivalent to the P
basic insulation of cords complying with IEC
60227 or IEC 60245, or
no breakdown when a voltage of 2000 V is P
applied for 15 min between the conductor and
metal foil wrapped around the insulation
For class II construction, the requirements for P
supplementary insulation and reinforced
insulation apply,
except that the sheath of a cord complying with P
IEC 60227 or IEC 60245 may provide
supplementary insulation.
A single layer of internal wiring insulation does P
not provide reinforced insulation
23.6 Sleeving used as supplementary insulation on P
internal wiring retained in position by clamping
at both ends, or
be such that it can only be removed by N/A
breaking or cutting
23.7 The colour combination green/yellow only used P
for earthing conductors
23.8 Aluminium wires not used for internal wiring No such material P
23.9 Stranded conductors not consolidated by P
soldering where they are subjected to contact
pressure, unless
the contact pressure is provided by spring N/A
terminals
23.10 The insulation and sheath of internal wiring, N/A
incorporated in external hoses for the
connection of an appliance to the water mains,
at least equivalent to that of light polyvinyl
chloride sheathed flexible cord (60227 IEC 52)
24 COMPONENTS P
24.1 Components comply with safety requirements P
in relevant IEC standards

TRF No. IEC60335_2_9M


Page 172 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

List of components.................................................. : (see appended table) P


Motors not required to comply with IEC 60034- N/A
1, they are tested as part of the appliance
Relays tested as part of the appliance, or N/A
alternatively acc. to IEC 60730-1, and meeting N/A
the additional requirements in IEC 60335-1
The requirements of Clause 29 apply between P
live parts of components and accessible parts
of the appliance
Components can comply with the requirements P
for clearances and creepage distances for
functional insulation in the relevant component
standard
30.2 of this standard apply to parts of non- P
metallic material in components including
parts of non-metallic material supporting
current-carrying connections
Components that have not been previously P
tested to comply with the IEC standard for the
relevant component are tested according to the
requirements of 30.2
Components that have been previously tested P
to comply with the resistance to fire
requirements in the IEC standard for the
relevant component need not be retested
provided the specified conditions are met
If these conditions are not satisfied, the P
component is tested as part of the appliance.
Power electronic converter circuits not N/A
required to comply with IEC 62477-1, they are
tested as part of the appliance
If components have not been tested and found P
to comply with relevant IEC standard for the
number of cycles specified, they are tested in
accordance with 24.1.1 to 24.1.9
For components mentioned in 24.1.1 to 24.1.9 P
no additional tests specified in the relevant
component standard are necessary other than
those specified in 24.1.1 to 24.1.9
Components not tested and found to comply P
with relevant IEC standard and components
not marked or not used in accordance with its
marking, tested under the conditions occurring
in the appliance

TRF No. IEC60335_2_9M


Page 173 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Lampholders and starterholders that have not N/A


being tested and found to comply with the
relevant IEC standard, tested as a part of the
appliance and additionally according to the
gauging and interchangeability requirements of
the relevant IEC standard
No additional tests specified for nationally N/A
standardized plugs such as those detailed in
IEC/TR 60083 or connectors complying with the
standard sheets of IEC 60320-1 and IEC 60309
24.1.1 Capacitors likely to be permanently subjected N/A
to the supply voltage and used for radio
interference suppression or for voltage
dividing, complying with IEC 60384-14
If the capacitors have to be tested, they are N/A
tested according to Annex F
24.1.2 Transformers in associated switch mode power N/A
supplies comply with Annex BB of IEC 61558-2-
16
Safety isolating transformers complying with N/A
IEC 61558-2-6
If they have to be tested, they are tested N/A
according to Annex G
24.1.3 Switches complying with IEC 61058-1, the N/A
number of cycles of operation being at least 10
000
If they have to be tested, they are tested N/A
according to Annex H
If the switch operates a relay or contactor, the N/A
complete switching system is subjected to the
test
If the switch only operates a motor staring N/A
relay complying with IEC 60730-2-10 with the
number of cycles of a least 10 000 as specified,
the complete switching system need not be
tested
Switches controlling heating elements of N/A
hotplates subjected to 30 000 cycles of
operation (IEC 60335-2-9)
Switches controlling heating elements of N/A
toaster subjected to 50000 cycles of operation
(IEC 60335-2-9)
24.1.4 Automatic controls complying with IEC 60730-1 with the relevant part 2. The P
number of cycles of operation being at least:

TRF No. IEC60335_2_9M


Page 174 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

- thermostats: 10 000 P
- temperature limiters: 1 000 N/A
- self-resetting thermal cut-outs: 300 N/A
- voltage maintained non-self-resetting 1 000 N/A
thermal cut-outs:
- other non-self-resetting thermal cut- 30 N/A
outs:
- timers: 3 000 N/A
- energy regulators for automatic 100 000 N/A
action (IEC 60335-2-9):
- energy regulators for manual action 10 000 N/A
(IEC 60335-2-9):
Self-resetting thermal cut-outs for N/A
heating elements of glass-ceramic 100 000
hotplates (IEC 60335-2-9)
Self-resetting thermal cut-outs for 10 000 N/A
other hotplates (IEC 60335-2-9)
The number of cycles for controls operating N/A
during clause 11 need not be declared, if the
appliance meets the requirements of this
standard when they are short-circuited
Thermal motor protectors are tested in N/A
combination with their motor under the
conditions specified in Annex D
For water valves containing live parts and that N/A
are incorporated in external hoses for
connection of an appliance to the water mains,
the degree of protection declared for subclause
6.5.2 of IEC 60730-2-8 is IPX7
Thermal cut-outs of the capillary type comply N/A
with the requirements for type 2.K controls in
IEC 60730-2-9
24.1.5 Appliance couplers complying with IEC 60320- N/A
1
However, for class II appliances classified N/A
higher than IPX0, the appliance couplers
complying with IEC 60320-2-3
Interconnection couplers complying with IEC N/A
60320-2-2

TRF No. IEC60335_2_9M


Page 175 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Appliance couplers incorporating thermostats, N/A


thermal cut-outs or fuses comply with IEC
60320-1, with exceptions specified in IEC 60335-
9 (IEC 60335-2-9)
Not applicable to conditions as specified N/A
(IEC 60335-2-9)
24.1.6 Small lamp holders similar to E10 lampholders P
complying with IEC 60238, the requirements for
E10 lampholders being applicable
24.1.7 For remote operation of the appliance via a N/A
telecommunication network, the relevant
standard for the telecommunication interface
circuitry in the appliance is IEC 62151
24.1.8 The relevant standard for thermal links is IEC P
60691
Thermal links not complying with IEC 60691 are N/A
considered to be an intentionally weak part for
the purposes of Clause 19
24.1.9 Contactors and relays, other than motor N/A
starting relays, tested as part of the appliance
They are also tested in accordance with Clause N/A
17 of IEC 60730-1, the number of cycles of
operations in 24.1.4 selected according to the
contactor or relay function in the appliance.....:
24.2 Appliances not fitted with: P
- switches or automatic controls in flexible P
cords
- devices causing the protective device in the P
fixed wiring to operate in the event of a fault in
the appliance
- thermal cut-outs that can be reset by P
soldering, unless
the solder has a melding point of at least 230 N/A
˚C
24.3 Switches intended for all-pole disconnection of N/A
stationary appliances are directly connected to
the supply terminals and have a contact
separation in all poles, providing full
disconnection under overvoltage category III
conditions

TRF No. IEC60335_2_9M


Page 176 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

24.4 Plugs and socket-outlets for extra-low voltage N/A


circuits and heating elements, not
interchangeable with plugs and socket-outlets
listed in IEC/TR 60083 or IEC 60906-1 or with
connectors and appliance inlets complying
with the standard sheets of IEC 60320-1
24.5 Capacitors in auxiliary windings of motors N/A
marked with their rated voltage and
capacitance, and used accordingly
Voltage across capacitors in series with a N/A
motor winding does not exceed 1,1 times rated
voltage, when the appliance is supplied at
1,1 times rated voltage under minimum load
24.6 Working voltage of motors connected to the N/A
supply mains and having basic insulation that
is inadequate for the rated voltage of the
appliance, not exceeding 42 V
In addition, the motors comply with the N/A
requirements of Annex I
24.7 Detachable hose-sets for connection of N/A
appliances to the water mains comply with IEC
61770
They are supplied with the appliance N/A
Appliances intended to be permanently N/A
connected to the water mains not connected by
a detachable hose-set
24.8 Motor running capacitors in appliances for N/A
which 30.2.3 is applicable and that are
permanently connected in series with a motor
winding, not causing a hazard in event of a
failure
One or more of the following conditions are to be met: N/A
- the capacitors are of class P2 according to N/A
IEC 60252-1
- the capacitors are housed within a metallic or N/A
ceramic enclosure
- the distance of separation of the outer surface N/A
to adjacent non-metallic parts exceeds 50 mm
- adjacent non-metallic parts within 50 mm N/A
withstand the needle-flame test of Annex E
- adjacent non-metallic parts within 50 mm N/A
classified as at least V-1 according to IEC
60695-11-10

TRF No. IEC60335_2_9M


Page 177 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

24.101 Thermostats and energy regulators P


incorporating an off position: off position
maintained under test conditions
(IEC 60335-2-9)
Thermostats and energy regulators P
incorporating an off position : no breakdown
after application of 500V across the contacts
not switch on as a result of variations in
ambient temperature (IEC 60335-2-9)
24.102 Thermal cut-outs incorporated in food N/A
dehydrators in order to comply with 19.4 are
non-self-resetting (IEC 60335-2-9)
25 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS P
25.1 Appliance not intended for permanent connection to fixed wiring, means for P
connection to the supply:
- supply cord fitted with a plug, the current P
rating and voltage rating of the plug being not
less than the corresponding ratings of its
associated appliance
- an appliance inlet having at least the same N/A
degree of protection against moisture as
required for the appliance, or
- pins for insertion into socket-outlets N/A
Appliances incorporating an appliance inlet N/A
other than those standardized in IEC 60320-
1,shall be supplied with a cord set
(IEC 60335-2-9)
25.2 Appliance not provided with more than one P
means of connection to the supply mains
Stationary appliance for multiple supply may N/A
be provided with more than one means of
connection, provided electric strength test of
1250 V for 1 min between each means of
connection causes no breakdown
25.3 Appliance intended to be permanently connected to fixed wiring provided N/A
with one of the following means for connection to the supply mains:
- a set of terminals allowing the connection of a N/A
flexible cord
- a fitted supply cord N/A
- a set of supply leads accommodated in a N/A
suitable compartment

TRF No. IEC60335_2_9M


Page 178 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

- a set of terminals for the connection of cables N/A


of fixed wiring, cross-sectional areas specified
in 26.6, and the appliance allows the
connection of the supply conductors after the
appliance has been fixed to its support
- a set of terminals and cable entries, conduit N/A
entries, knock-outs or glands, allowing
connection of appropriate types of cable or
conduit, and the appliance allows the
connection of the supply conductors after the
appliance has been fixed to its support
For a fixed appliance constructed so that parts N/A
can be removed to facilitate easy installation,
this requirement is met if it is possible to
connect the fixed wiring without difficulty after
a part of the appliance has been fixed to its
support
25.4 Cable and conduit entries, rated current of N/A
appliance not exceeding 16 A, dimension
according to table 10 (mm).................................... :
Introduction of conduit or cable does not N/A
reduce clearances or creepage distances
below values specified in clause 29
25.5 Method for assembling the supply cord to the appliance: P
- type X attachment N/A
- type Y attachment P
- type Z attachment, if allowed in relevant part 2 N/A
Type X attachment, other than those with a N/A
specially prepared cord, not used for flat twin
tinsel cords
For multi-phase appliances supplied with a N/A
supply cord and that are intended to be
permanently connected to fixed wiring, the
supply cord is assembled to the appliance by
type Y attachment
25.6 Plugs fitted with only one flexible cord P
25.7 Supply cords, other than for class III appliances, being one of the following P
types:
- rubber sheathed (at least 60245 IEC 53) H05RR-F P
- polychloroprene sheathed (at least 60245 IEC N/A
57)
- polyvinyl chloride sheathed. Not used if they are likely to touch metal parts P
having a temperature rise exceeding 75 K during the test of clause 11

TRF No. IEC60335_2_9M


Page 179 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

 light polyvinyl chloride sheathed cord N/A


(60227 IEC 52), for appliances not
exceeding 3 kg
 ordinary polyvinyl chloride sheathed N/A
cord (60227 IEC 53), for other
appliances
- heat resistant polyvinyl chloride sheathed. Not used for type X attachment N/A
other than specially prepared cords
 heat-resistant light polyvinyl chloride N/A
sheathed cord (60227 IEC 56), for
appliances not exceeding 3 kg
 heat-resistant polyvinyl chloride N/A
sheathed cord (60227 IEC 57), for other
appliances
Supply cords for class III appliances N/A
adequately insulated
Test with 500 V for 2 min for supply cords of N/A
class III appliances that contain live parts
-supply cord of appliances intended for outdoor N/A
use shall be polychloroprene sheathed
(IEC 60335-2-9)
25.8 Nominal cross-sectional area of supply cords 13,6A 1,0mm2 P
not less than table 11; rated current (A); cross- supply cords :<2m
sectional area (mm²)................................................ :
25.9 Supply cords not in contact with sharp points P
or edges
25.10 Supply cord of class I appliances have a P
green/yellow core for earthing
In multi-phase appliances, the colour of the N/A
neutral conductor of the supply cord is blue.
25.11 Conductors of supply cords not consolidated P
by soldering where they are subject to contact
pressure, unless
the contact pressure is provided by spring N/A
terminals
25.12 Insulation of the supply cord not damaged N/A
when moulding the cord to part of the
enclosure
25.13 Inlet openings so constructed as to prevent P
damage to the supply cord

TRF No. IEC60335_2_9M


Page 180 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

If the enclosure at the inlet opening is not of P


insulating material, If it is not evident that the
supply cord can be introduced without risk of
damage, a non-detachable lining or bushing
complying with 29.3 for supplementary
insulation provided
If unsheathed supply cord, a similar additional N/A
bushing or lining is required, unless the
appliance is
class 0, or N/A
a class III appliance not containing live parts N/A
25.14 Supply cords moved while in operation N/A
adequately protected against excessive flexing
Flexing test, as described: N/A
- applied force (N).....................................................: N/A
- number of flexings.................................................: N/A
The test does not result in: N/A
- short-circuit between the conductors, such N/A
that the current exceeds a value of twice the
rated current
- breakage of more than 10% of the strands of N/A
any conductor
- separation of the conductor from its terminal N/A
- loosening of any cord guard N/A
- damage to the cord or the cord guard N/A
- broken strands piercing the insulation and N/A
becoming accessible
25.15 For appliances with supply cord and P
appliances to be permanently connected to
fixed wiring by a flexible cord, conductors of
the supply cord relieved from strain, twisting
and abrasion by use of cord anchorage
The cord cannot be pushed into the appliance P
to such an extent that the cord or internal parts
of the appliance can be damaged
Pull and torque test of supply cord: P
- fixed appliances: pull 100 N; torque (not on N/A
automatic cord reel) (Nm)...................................... :
- other appliances: values shown in table 12: P
mass (kg); pull (N); torque (not on automatic
cord reel) (Nm).......................................................... :

TRF No. IEC60335_2_9M


Page 181 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Pull and torque test of supply cord, values 100N 0,35Nm P


shown in table 12: mass (kg); pull (N); torque
(not on automatic cord reel) (Nm)........................:
Cord not damaged and max. 2 mm P
displacement of the cord
25.16 Cord anchorages for type X attachments constructed and located so that: N/A
- replacement of the cord is easily possible N/A
- it is clear how the relief from strain and the N/A
prevention of twisting are obtained
- they are suitable for different types of supply N/A
cord
- cord cannot touch the clamping screws of N/A
cord anchorage if these screws are accessible,
unless
they are separated from accessible metal parts N/A
by supplementary insulation
- the cord is not clamped by a metal screw N/A
which bears directly on the cord
- at least one part of the cord anchorage N/A
securely fixed to the appliance, unless
it is part of a specially prepared cord N/A
- screws which have to be operated when N/A
replacing the cord do not fix any other
component, unless
the appliance becomes inoperative or N/A
incomplete or the parts cannot be removed
without a tool
- if labyrinths can be bypassed the test of 25.15 N/A
is nevertheless withstood
- for class 0, 0I and I appliances they are of N/A
insulating material or are provided with an
insulating lining, unless
failure of the insulation of the cord does not N/A
make accessible metal parts live
- for class II appliances they are of insulating N/A
material, or
if of metal, they are insulated from accessible N/A
metal parts by supplementary insulation
After the test of 25.15, under the conditions N/A
specified, the conductors have not moved by
more than 1 mm in the terminals

TRF No. IEC60335_2_9M


Page 182 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

25.17 Adequate cord anchorages for type Y and Z P


attachment, test with the cord supplied with the
appliance
25.18 Cord anchorages only accessible with the aid N/A
of a tool, or
Constructed so that the cord can only be fitted N/A
with the aid of a tool
25.19 Type X attachment, glands not used as cord N/A
anchorage in portable appliances
Tying the cord into a knot or tying the cord N/A
with string not used
25.20 The insulated conductors of the supply cord P
for type Y and Z attachment additionally
insulated from accessible metal parts
25.21 Space for supply cord for type X attachment or for connection of fixed wiring N/A
constructed:
- to permit checking of conductors with respect N/A
to correct positioning and connection before
fitting any cover
- so there is no risk of damage to the N/A
conductors or their insulation when fitting the
cover
- for portable appliances, so that the N/A
uninsulated end of a conductor, if it becomes
free from the terminal, prevented from contact
with accessible metal parts
2 N test to the conductor for portable N/A
appliances; no contact with accessible metal
parts
25.22 Appliance inlets: N/A
- live parts not accessible during insertion or N/A
removal
Requirement not applicable to appliance inlets N/A
complying with IEC 60320-1
- connector can be inserted without difficulty N/A
- the appliance is not supported by the N/A
connector
- not for cold conditions if temp. rise of N/A
external metal parts exceeds 75 K during
clause 11, unless
the supply cord is unlikely to touch such metal N/A
parts

TRF No. IEC60335_2_9M


Page 183 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

25.23 Interconnection cords comply with the N/A


requirements for the supply cord, except that:
- the cross-sectional area of the conductors is N/A
determined on the basis of the maximum
current during clause 11
- the thickness of the insulation may be N/A
reduced
If necessary, electric strength test of 16.3 N/A
25.24 Interconnection cords not detachable without N/A
the aid of a tool if compliance with this
standard is impaired when they are
disconnected
25.25 Dimensions of pins that are inserted into N/A
socket-outlets compatible with the dimensions
of the relevant socket-outlet.
Dimensions of pins and engagement face in N/A
accordance with the dimensions of the relevant
plug in IEC/TR 60083
26 TERMINALS FOR EXTERNAL CONDUCTORS P
26.1 Appliances provided with terminals or equally P
effective devices for connection of external
conductors
Terminals only accessible after removal of a P
non-detachable cover, except
for class III appliances that do not contain live N/A
parts
Earthing terminals may be accessible if a tool N/A
is required to make the connections and means
are provided to clamp the wire independently
from its connection
26.2 Appliances with type X attachment and N/A
appliances for the connection of cables to fixed
wiring provided with terminals in which
connections are made by means of screws,
nuts or similar devices, unless
the connections are soldered N/A
Screws and nuts not used to fix any other N/A
component, except
internal conductors, if so arranged that they N/A
are unlikely to be displaced when fitting the
supply conductors

TRF No. IEC60335_2_9M


Page 184 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

If soldered connections used, the conductor so N/A


positioned or fixed that reliance is not placed
on soldering alone, unless
barriers provided so that neither clearances N/A
nor creepage distances between live parts and
other metal parts reduced below the values for
supplementary insulation if the conductor
becomes free at the soldered joint
26.3 Terminals for type X attachment and for N/A
connection of cables of fixed wiring so
constructed that the conductor is clamped
between metal surfaces with sufficient contact
pressure but without damaging the conductor
Terminals fixed so that when the clamping means is tightened or loosened: N/A
- the terminal does not become loose N/A
- internal wiring is not subjected to stress N/A
- neither clearances nor creepage distances are N/A
reduced below the values in clause 29
Compliance checked by inspection and by the N/A
test of subclause 9.6 of IEC 60999-1, the torque
applied being equal to two-thirds of the torque
specified (Nm)........................................................... :
No deep or sharp indentations of the N/A
conductors
26.4 Terminals for type X attachment, except those N/A
having a specially prepared cord and those for
the connection of cables of fixed wiring, no
special preparation of conductors such as by
soldering, use of cable lugs, eyelets or similar,
and
so constructed or placed that conductors N/A
prevented from slipping out when clamping
screws or nuts are tightened
26.5 Terminals for type X attachment so located or N/A
shielded that if a wire of a stranded conductor
escapes, no risk of accidental connection to
other parts that result in a hazard
Stranded conductor test, 8 mm insulation N/A
removed
No contact between live parts and accessible N/A
metal parts and,
for class II constructions, between live parts N/A
and metal parts separated from accessible
metal parts by supplementary insulation only

TRF No. IEC60335_2_9M


Page 185 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

26.6 Terminals for type X attachment and for N/A


connection of cables of fixed wiring suitable
for connection of conductors with cross-
sectional area according to table 13; rated
current (A); nominal cross-sectional area (mm²)
.......................................................................................:
If a specially prepared cord is used, terminals N/A
need only be suitable for that cord
26.7 Terminals for type X attachment, except in N/A
class III appliances not containing live parts,
accessible after removal of a cover or part of
the enclosure
26.8 Terminals for the connection of fixed wiring, N/A
including the earthing terminal, located close
to each other
26.9 Terminals of the pillar type constructed and N/A
located as specified
26.10 Terminals with screw clamping and screwless P
terminals not used for flat twin tinsel cords,
unless
conductors ends fitted with means suitable for N/A
screw terminals
Pull test of 5 N to the connection P
26.11 For type Y and Z attachment, soldered, welded, P
crimped or similar connections may be used
For Class II appliances, the conductor so N/A
positioned or fixed that reliance is not placed
on soldering, welding or crimping alone
If soldering, welding or crimping alone used, N/A
barriers provided so that clearances and
creepage distances between live parts and
other metal parts are not reduced below the
values for supplementary insulation if the
conductor becomes free
27 PROVISION FOR EARTHING P
27.1 Accessible metal parts of Class 0I and I P
appliances permanently and reliably connected
to an earthing terminal or earthing contact of
the appliance inlet
Earthing terminals and earthing contacts not P
connected to the neutral terminal
Class 0, II and III appliances have no provision N/A
for protective earthing

TRF No. IEC60335_2_9M


Page 186 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Class II appliances and class III appliances can N/A


incorporate an earth for functional purposes
Safety extra-low voltage circuits not earthed, N/A
unless
protective extra-low voltage circuits N/A
No earthing via flexible metal tubes, coiled P
springs and cord anchorage (IEC 60335-2-9)
27.2 Clamping means of earthing terminals P
adequately secured against accidental
loosening
Terminals for the connection of external N/A
equipotential bonding conductors allow
connection of conductors of 2.5 to 6 mm², and
do not provide earthing continuity between N/A
different parts of the appliance, and
conductors cannot be loosened without the aid N/A
of a tool
Requirements not applicable to class II N/A
appliances and class III appliances that
incorporate an earth for functional purposes
27.3 For a detachable part having an earth N/A
connection and being plugged into another
part of the appliance, the earth connection is
made before and separated after current-
carrying connections when removing the part
For appliances with supply cords, current- P
carrying conductors become taut before
earthing conductor, if the cord slips out of the
cord anchorage
Requirements not applicable to class II N/A
appliances and class III appliances that
incorporate an earth for functional purposes
27.4 No risk of corrosion resulting from contact P
between parts of the earthing terminal and the
copper of the earthing conductor or other
metal
Parts providing earthing continuity, other than P
parts of a metal frame or enclosure, have
adequate resistance to corrosion
If of steel, these parts provided with an >7,0μm P
electroplated coating with a thickness at least
5 µm

TRF No. IEC60335_2_9M


Page 187 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Adequate protection against rusting of parts of P


coated or uncoated steel, only intended to
provide or transmit contact pressure
In the body of the earthing terminal is a part of P
a frame or enclosure of aluminium or
aluminium alloys, precautions taken to avoid
risk of corrosion
Requirements not applicable to class II N/A
appliances and class III appliances that
incorporate an earth for functional purposes
27.5 Low resistance of connection between earthing P
terminal and earthed metal parts
This requirement does not apply to N/A
connections providing earthing continuity in
the protective extra-low voltage circuit,
provided the clearances of basic insulation are
based on the rated voltage of the appliance
Requirements not applicable to class II N/A
appliances and class III appliances that
incorporate an earth for functional purposes
Resistance not exceeding 0,1 Ω at the specified 0,08Ω P
low-resistance test (Ω )...........................................:
27.6 The printed conductors of printed circuit N/A
boards not used to provide earthing continuity
in hand-held appliances.
They may be used to provide earthing N/A
continuity in other appliances if at least two
tracks are used with independent soldering
points and the appliance complies with 27.5 for
each circuit
Requirements not applicable to class II N/A
appliances and class III appliances that
incorporate an earth for functional purposes
28 SCREWS AND CONNECTIONS P
28.1 Fixings, electrical connections and P
connections providing earthing continuity
withstand mechanical stresses
Screws not of soft metal liable to creep, such P
as zinc or aluminium
Diameter of screws of insulating material min. N/A
3 mm
Screws of insulating material not used for any N/A
electrical connections or connections
providing earthing continuity

TRF No. IEC60335_2_9M


Page 188 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Screws used for electrical connections or P


connections providing earthing continuity
screwed into metal
Screws not of insulating material if their N/A
replacement by a metal screw can impair
supplementary or reinforced insulation
For type X attachment, screws to be removed N/A
for replacement of supply cord or for user
maintenance, not of insulating material if their
replacement by a metal screw impairs basic
insulation
For screws and nuts; torque-test as specified (see appended table) P
in table 14................................................................... :
28.2 Electrical connections and connections P
providing earthing continuity constructed so
that contact pressure is not transmitted
through non-ceramic insulating material liable
to shrink or distort, unless
there is resiliency in the metallic parts to N/A
compensate for shrinkage or distortion of the
insulating material
This requirement does not apply to electrical connections in circuits of N/A
appliances for which:
 30.2.2 is applicable and that carry a N/A
current not exceeding 0,5 A
 30.2.3 is applicable and that carry a N/A
current not exceeding 0,2 A
28.3 Space-threaded (sheet metal) screws only used N/A
for electrical connections if they clamp the
parts together
Thread-cutting (self-tapping) screws and N/A
thread rolling screws only used for electrical
connections if they generate a full form
standard machine screw thread
Thread-cutting (self-tapping) screws not used if N/A
they are likely to be operated by the user or
installer
Thread-cutting, thread rolling and space threaded screws may be used in N/A
connections providing earthing continuity provided it is not necessary to
disturb the connection:
- in normal use, N/A
- during user maintenance, N/A

TRF No. IEC60335_2_9M


Page 189 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

- when replacing a supply cord having a type X N/A


attachment, or
- during installation N/A
At least two screws being used for each N/A
connection providing earthing continuity,
unless
the screw forms a thread having a length of at N/A
least half the diameter of the screw
28.4 Screws and nuts that make mechanical P
connection secured against loosening if they
also make electrical connections or
connections providing earthing continuity
This requirement does not apply to screws in P
the earthing circuit if at least two screws are
used, or
if an alternative earthing circuit is provided N/A
Rivets for electrical connections or N/A
connections providing earthing continuity
secured against loosening if the connections
are subjected to torsion
29 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION P
Clearances, creepage distances and solid P
insulation withstand electrical stress
For coatings used on printed circuits boards to N/A
protect the microenvironment (Type 1) or to
provide basic insulation (Type 2), Annex J
applies......................................................................... :
The microenvironment is pollution degree 1 N/A
under type 1 protection
For type 2 protection, the spacing between the N/A
conductors before the protection is applied is
not less than the values specified in Table 1 of
IEC 60664-3
These values apply to functional, basic, P
supplementary and reinforced insulation......... :
29.1 Clearances not less than the values specified (see appended table) P
in table 16, taking into account the rated
impulse voltage for the overvoltage categories
of table 15, unless.................................................... :
for basic insulation and functional insulation N/A
they comply with the impulse voltage test of
clause 14

TRF No. IEC60335_2_9M


Page 190 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

However, if the distances are affected by wear, P


distortion, movement of the parts or during
assembly, the clearances for rated impulse
voltages of 1500V and above are increased by
0,5 mm and the impulse voltage test is not
applicable
For appliances intended for use at altitudes N/A
exceeding 2 000 m, the clearances in Table 16
is increased according to the relevant
multiplier values in Table A.2 of IEC 60664-1
Impulse voltage test is not applicable: P
- when the microenvironment is pollution P
degree 3, or
- for basic insulation of class 0 and class 01 N/A
appliances
- to appliances intended for use at altitudes N/A
exceeding 2 000 m
Appliances are in overvoltage category II P
A force of 2 N is applied to bare conductors, P
other than heating elements
A force of 30 N is applied to accessible P
surfaces
29.1.1 Clearances of basic insulation withstand the P
overvoltages, taking into account the rated
impulse voltage
The values of table 16 or the impulse voltage (see appended table) P
test of clause 14 are applicable............................ :
Clearance at the terminals of tubular sheathed N/A
heating elements may be reduced to 1,0 mm if
the microenvironment is pollution degree 1
Lacquered conductors of windings considered N/A
to be bare conductors
29.1.2 Clearances of supplementary insulation not (see appended table) P
less than those specified for basic insulation in
table 16........................................................................ :
29.1.3 Clearances of reinforced insulation not less (see appended table) P
than those specified for basic insulation in
table 16, using the next higher step for rated
impulse voltage.........................................................:

TRF No. IEC60335_2_9M


Page 191 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

For double insulation, with no intermediate N/A


conductive part between basic and
supplementary insulation, clearances are
measured between live parts and the
accessible surface, and the insulation system
is treated as reinforced insulation
29.1.4 Clearances for functional insulation are the largest values determined from: P
- table 16 based on the rated impulse voltage. : (see appended table) P
- table F.7a in IEC 60664-1, frequency not P
exceeding 30 kHz
- clause 4 of IEC 60664-4, frequency exceeding N/A
30 kHz
If values of table 16 are largest, the impulse N/A
voltage test of clause 14 may be applied
instead, unless
the microenvironment is pollution degree 3, or P
the distances can be affected by wear, N/A
distortion, movement of the parts or during
assembly
However, clearances are not specified if the N/A
appliance complies with clause 19 with the
functional insulation short-circuited
Lacquered conductors of windings considered N/A
to be bare conductors
However, clearances at crossover points are N/A
not measured
Clearance between surfaces of PTC heating N/A
elements may be reduced to 1mm
29.1.5 Appliances having higher working voltages than rated voltage, clearances for N/A
basic insulation are the largest values determined from:
- table 16 based on the rated impulse voltage. : N/A
- table F.7a in IEC 60664-1, frequency not N/A
exceeding 30 kHz
- clause 4 of IEC 60664-4, frequency exceeding N/A
30 kHz
If clearances for basic insulation are selected N/A
from Table F.7a of IEC 60664-1 or Clause 4 of
IEC 60664-4, the clearances of supplementary
insulation are not less than those specified for
basic insulation

TRF No. IEC60335_2_9M


Page 192 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

If clearances for basic insulation are selected N/A


from Table F.7a of IEC 60664-1, the clearances
of reinforced insulation dimensioned as
specified in Table F.7a are to withstand 160%
of the withstand voltage required for basic
insulation
If clearances for basic insulation are selected N/A
from Clause 4 of IEC 60664-4, the clearances of
reinforced insulation are twice the value
required for basic insulation
If the secondary winding of a step-down N/A
transformer is earthed, or if there is an earthed
screen between the primary and secondary
windings, clearances of basic insulation on the
secondary side not less than those specified in
table 16, but using the next lower step for rated
impulse voltage
Circuits supplied with a voltage lower than N/A
rated voltage, clearances of functional
insulation are based on the working voltage
used as the rated voltage in table 15
29.2 Creepage distances not less than those (see appended table) P
appropriate for the working voltage, taking into
account the material group and the pollution
degree..........................................................................:
Pollution degree 2 applies, unless N/A
- precautions taken to protect the insulation; N/A
pollution degree 1
- insulation subjected to conductive pollution; P
pollution degree 3
A force of 2 N is applied to bare conductors, P
other than heating elements
A force of 30 N is applied to accessible P
surfaces
In a double insulation system, the working N/A
voltage for both the basic and supplementary
insulation is taken as the working voltage
across the complete double insulation system
Pollution degree 3 applies, unless the P
insulation is enclosed or located so that it is
unlikely to be exposed to pollution during
normal use of the appliance (IEC 60335-2-9)
29.2.1 Creepage distances of basic insulation not less (see appended table) P
than specified in table 17....................................... :

TRF No. IEC60335_2_9M


Page 193 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

However, if the working voltage is periodic and N/A


has a frequency exceeding 30 kHz, the
creepage distances are also determined from
table 2 of IEC 60664-4, these values being used
if exceeding the values in table 17...................... :
Except for pollution degree 1, corresponding N/A
creepage distance not less than the minimum
specified for the clearance in table 16, if the
clearance has been checked according to the
test of clause 14........................................................:
29.2.2 Creepage distances of supplementary (see appended table) P
insulation at least those specified for basic
insulation in table 17, or......................................... :
Table 2 of IEC 60664-4, as applicable................. : P
29.2.3 Creepage distances of reinforced insulation at (see appended table) P
least double those specified for basic
insulation in table 17, or......................................... :
Table 2 of IEC 60664-4, as applicable................. : P
29.2.4 Creepage distances of functional insulation not (see appended table) P
less than specified in table 18.............................. :
However, if the working voltage is periodic and N/A
has a frequency exceeding 30 kHz, the
creepage distances are also determined from
table 2 of IEC 60664-4, these values being used
if exceeding the values in table 18...................... :
Creepage distances may be reduced if the N/A
appliance complies with clause 19 with the
functional insulation short-circuited
29.3 Supplementary and reinforced insulation have P
adequate thickness, or a sufficient number of
layers, to withstand the electrical stresses
Compliance checked: P
- by measurement, in accordance with 29.3.1, P
or
- by an electric strength test in accordance with N/A
29.3.2, or
-for insulation, other than single layer internal N/A
wiring insulation by an assessment of the
thermal quality of the material combined with
an electric strength test, in accordance with
29.3.3, and
for accessible parts of reinforced insulation N/A
consisting of a single layer, by measurement in
accordance with 29.3.4, or

TRF No. IEC60335_2_9M


Page 194 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

- by an assessment of the thermal quality of the N/A


material according to 29.3.3 combined with an
electric strength test in accordance with 23.5,
for each single layer internal wiring insulation
touching each other, or
- as specified in subclause 6.3 of IEC 60664-4 N/A
for insulation that is subjected to any periodic
voltage having a frequency exceeding 30 kHz
Requirement not applied to the sheath of a N/A
visibly glowing heating element that is
inaccessible to test probe 41 of IEC 61032
(IEC 60335-2-9)
29.3.1 Supplementary insulation have a thickness of P
at least 1 mm
Reinforced insulation have a thickness of at P
least 2 mm
29.3.2 Each layer of material withstand the electric N/A
strength test of 16.3 for supplementary
insulation
Supplementary insulation consist of at least 2 N/A
layers
Reinforced insulation consist of at least 3 N/A
layers
29.3.3 The insulation is subjected to the dry heat test N/A
Bb of IEC 60068-2-2, followed by
the electric strength test of 16.3 N/A
If the temperature rise during the tests of N/A
clause 19 does not exceed the value specified
in table 3, the test of IEC 60068-2-2 is not
carried out
29.3.4 Thickness of accessible parts of reinforced N/A
insulation consisting of a single layer not less
than specified in table 19....................................... :
30 RESISTANCE TO HEAT AND FIRE P
30.1 External parts of non-metallic material, P
parts supporting live parts, and P
parts of thermoplastic material providing P
supplementary or reinforced insulation
sufficiently resistant to heat P
Ball-pressure test according to IEC 60695-10-2 P

TRF No. IEC60335_2_9M


Page 195 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

External parts tested at 40 C plus the (see appended table) P


maximum temperature rise determined during
the test of clause 11, or at 75 C, whichever is
the higher; temperature (C)..................................:
Parts supporting live parts tested at 40C plus (see appended table) P
the maximum temperature rise determined
during the test of clause 11, or at 125 C,
whichever is the higher; temperature (C).........:
Parts of thermoplastic material providing (see appended table) P
supplementary or reinforced insulation tested
at 25 C plus the maximum temperature rise
determined during clause 19, if higher;
temperature (C)....................................................... :
Temperature rises occurring during the test of N/A
19.102 are not taken into account
(IEC 60335-2-9)
30.2 Parts of non-metallic material resistant to P
ignition and spread of fire
This requirement does not apply to: P
parts having a mass not exceeding 0,5 g, P
provided the cumulative effect is unlikely to
propagate flames that originate inside the
appliance by propagating flames from one part
to another, or
decorative trims, knobs and other parts P
unlikely to be ignited or to propagate flames
that originate inside the appliance
Compliance checked by the test of 30.2.1, and P
in addition:
- for attended appliances, 30.2.2 applies N/A
- for unattended appliances, 30.2.3 applies P
For appliances for remote operation, 30.2.3 N/A
applies
For base material of printed circuit boards, N/A
30.2.4 applies
For breadmakers, food dehydrators, 30.2.3 N/A
applies (IEC 60335-2-9)
For hotplates 30.2.3 applies (IEC 60335-2-9) P
For cookers, ovens, roasters, rotary grills if N/A
they incorporate a timer or if their instructions
indicate a cooking operation longer than 1h ,
30.2.3 applies (IEC 60335-2-9)

TRF No. IEC60335_2_9M


Page 196 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

For other appliances, 30.2.2 applies N/A


(IEC 60335-2-9)
30.2.1 Parts of non-metallic material subjected to the P
glow-wire test of IEC 60695-2-11 at 550 C
However, test not carried out if the material is P
classified as having a glow-wire flammability
index according to IEC 60695-2-12 of at least
550 C, or
the material is classified at least HB40 N/A
according to IEC 60695-11-10
Parts for which the glow-wire test cannot be N/A
carried out need to meet the requirements in
ISO 9772 for material classified HBF
30.2.2 Appliances operated while attended, parts of N/A
non-metallic material supporting current-
carrying connections, and
parts of non-metallic material within a distance N/A
of 3mm of such connections,
subjected to the glow-wire test of IEC 60695-2- N/A
11
The test severity is: N/A
- 750 C, for connections carrying a current N/A
exceeding 0,5 A during normal operation
- 650 C, for other connections N/A
Glow-wire applied to an interposed shielding N/A
material, if relevant
The glow-wire test is not carried out on parts of material classified as having N/A
a glow-wire flammability index according to IEC 60695-2-12 of at least:
- 750 C, for connections carrying a current N/A
exceeding 0,5 A during normal operation
- 650 C, for other connections N/A
The glow-wire test is also not carried out on small parts. These parts are to: N/A
- comprise material having a glow-wire N/A
flammability index of at least 750 C, or 650 C
as appropriate, or
- comply with the needle-flame test of Annex E, N/A
or
- comprise material classified as V-0 or V-1 N/A
according to IEC 60695-11-10............................... :

TRF No. IEC60335_2_9M


Page 197 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Glow-wire test not applicable to conditions as N/A


specified..................................................................... :
30.2.3 Appliances operated while unattended, tested P
as specified in 30.2.3.1 and 30.2.3.2
The tests are not applicable to conditions as N/A
specified..................................................................... :
30.2.3.1 Parts of non-metallic material supporting P
connections carrying a current exceeding 0,2 A
during normal operation, and
parts of non-metallic material, other than small P
parts, within a distance of 3 mm,
subjected to the glow-wire test of IEC 60695-2- P
11 with a test severity of 850 °C
Glow-wire applied to an interposed shielding P
material, if relevant
The glow-wire test is not carried out on parts of P
material classified as having a glow-wire
flammability index according to IEC 60695-2-12
of at least 850 °C
30.2.3.2 Parts of non-metallic material supporting P
connections, and
parts of non-metallic material within a distance P
of 3mm,
subjected to glow-wire test of IEC 60695-2-11 P
The test severity is: P
- 750 C, for connections carrying a current P
exceeding 0,2 A during normal operation
- 650 C, for other connections N/A
Glow-wire applied to an interposed shielding P
material, if relevant
However, the glow-wire test of 750 C or 650 C as appropriate, is not carried P
out on parts of material fulfilling both or either of the following
classifications:
- a glow-wire ignition temperature according to P
IEC 60695-2-13 of at least:
 775 C, for connections carrying a P
current exceeding 0,2 A during normal
operation
 675 C, for other connections N/A
- a glow-wire flammability index according to P
IEC 60695-2-12 of at least:

TRF No. IEC60335_2_9M


Page 198 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

- 750 C, for connections carrying a current P


exceeding 0,2 A during normal operation
- 650 C, for other connections N/A
The glow-wire test is also not carried out on small parts. These parts are to: N/A
- comprise material having a glow-wire ignition N/A
temperature of at least 775 C or 675 C as
appropriate, or
- comprise material having a glow-wire N/A
flammability index of at least 750 C or 650 C
as appropriate, or
- comply with the needle-flame test of Annex E, N/A
or
- comprise material classified as V-0 or V-1 N/A
according to IEC 60695-11-10
The consequential needle-flame test of Annex E applied to non-metallic parts N/A
that encroach within the vertical cylinder placed above the centre of the
connection zone and on top of the non-metallic parts supporting current-
carrying connections, and parts of non-metallic material within a distance of 3
mm of such connections if these parts are those:
- parts that withstood the glow-wire test of IEC N/A
60695-2-11 of 750 C or 650 C as appropriate,
but produce a flame that persist longer than 2
s, or
- parts that comprised material having a glow- N/A
wire flammability index of at least 750 C or 650
C as appropriate, or
- small parts, that comprised material having a N/A
glow-wire flammability index of at least 750 C
or 650 C as appropriate, or
- small parts for which the needle-flame test of N/A
Annex E was applied, or
- small parts for which a material classification N/A
of V-0 or V-1 was applied
However, the consequential needle-flame test is not carried out on non- N/A
metallic parts, including small parts, within the cylinder that are:
- parts having a glow-wire ignition temperature N/A
of at least 775 C or 675 C as appropriate, or
- parts comprising material classified as V-0 or N/A
V-1 according to IEC 60695-11-10, or

TRF No. IEC60335_2_9M


Page 199 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

- parts shielded by a flame barrier that meets N/A


the needle-flame test of Annex E or that
comprises material classified as V-0 or V-1
according to IEC 60695-11-10
30.2.4 Base material of printed circuit boards N/A
subjected to the needle-flame test of Annex E
Test not applicable to conditions as specified : N/A
31 RESISTANCE TO RUSTING P
Relevant ferrous parts adequately protected P
against rusting
For appliances intended for outdoor use, N/A
compliance is checked by the salt mist test, Kb
of IEC 60068-2-52, severity 2 applicable(IEC
60335-2-9)
Before the test, enclosures having a coating are N/A
scratched by means of hardened steel pin
(IEC 60335-2-
9)
After the test, the appliance shall not have N/A
deteriorated to such an extent that compliance
with this standard, in particular with Clauses 8
and 27, is impaired (IEC 60335-2-
9)
After the test, the coating shall not be broken N/A
and shall not have loosened from the surface
(IEC 60335-2-
9)
32 RADIATION, TOXICITY AND SIMILAR HAZARDS P
Appliance does not emit harmful radiation or P
present a toxic or similar hazard due to their
operation in normal use
Compliance is checked by the limits or tests N/A
specified in part 2, if relevant
A ANNEX A (INFORMATIVE) N/A
ROUTINE TESTS
Description of routine tests to be carried out by N/A
the manufacturer
B ANNEX B (NORMATIVE) N/A
APPLIANCES POWERED BY RECHARGEABLE BATTERIES THAT ARE
RECHARGED IN THE APPLIANCE
The following modifications to this standard N/A
are applicable for appliances powered by
batteries that are recharged in the appliance

TRF No. IEC60335_2_9M


Page 200 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

This annex does not apply to battery chargers N/A


Three forms of construction covered: N/A
a) Appliance supplied directly from the supply N/A
mains or a renewable energy source, the
battery charging circuitry and other supply unit
circuitry incorporated within the appliance
b) The part of the appliance incorporating the N/A
battery is supplied from the supply mains or a
renewable energy source, via a detachable
supply unit. The battery charging circuitry is
incorporated within the part of the appliance
containing the battery
c) The part of the appliance incorporating the N/A
battery is supplied from the supply mains or a
renewable energy source, via a detachable
supply unit. The battery charging circuitry is
incorporated within the detachable supply unit
3.1.9 Appliance operated under the following conditions: N/A
- the appliance, supplied by its fully charged N/A
battery, operated as specified in relevant part 2
- the battery is charged, the battery being N/A
initially discharged to such an extent that the
appliance cannot operate
-if possible, the appliance is supplied from the N/A
supply mains through its battery charger, the
battery being initially discharged to such an
extent that the appliance cannot operate. The
appliance is operated as specified in relevant
part 2
- if the appliance incorporates inductive N/A
coupling between two parts that are detachable
from each other, the appliance is supplied from
the supply mains with the detachable part
removed
3.6.2 Part to be removed in order to discard the N/A
battery is not considered to be detachable
5.B.101 Appliances supplied from the supply mains N/A
tested as specified for motor-operated
appliances
7.1 Battery compartment for batteries intended to N/A
be replaced by the user, marked with battery
voltage and polarity of the terminals

TRF No. IEC60335_2_9M


Page 201 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

The positive terminal indicated by symbol IEC N/A


60417-5005 and the negative terminal by
symbol IEC 60417-5006
Appliances intending to be supplied from a N/A
detachable supply unit marked with symbol
IEC 60417-6181 and its type reference along
with symbol ISO 7000-0790 (2004-01), or
use only with <model designation> supply unit N/A
........................................................................... :
7.6 Symbols 60417-5005 and IEC 60417-5006 N/A
7.12 The instructions give information regarding N/A
charging
The instructions for appliances incorporating N/A
batteries intended to be replaced by the user
includes required information
Details about how to remove batteries N/A
containing materials hazardous to the
environment given
For appliances intending to be supplied from a detachable supply unit for the N/A
purposes of recharging the battery, the type reference of the detachable
supply unit is stated along with the following:
WARNING: For the purposes of recharging the N/A
battery, only use the detachable supply unit
provided with this appliance
If the symbol for detachable supply unit is N/A
used, its meaning is explained
7.15 Markings placed on the part of the appliance N/A
connected to the supply mains
The type reference of the detachable supply N/A
unit is placed in close proximity to the symbol
8.2 Appliances having batteries that according to N/A
the instruction may be replaced by the user
need only have basic insulation between live
parts and the inner surface of the battery
compartment
If the appliance can be operated without N/A
batteries, double or reinforced insulation
required
11.7 The battery is charged for the period stated in N/A
the instructions or 24 h...........................................:

TRF No. IEC60335_2_9M


Page 202 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

11.8 Temperature rise of the battery surface does N/A


not exceed the limit in the battery
manufacturer’s specification; measured (K);
limit (K)........................................................................ :
If no limit specified, the temperature rise does N/A
not exceed 20 K; measured (K) ........................... :
19.1 Appliances subjected to tests of 19.B.101, N/A
19.B.102 and 19.B.103
19.10 Not applicable N/A
19.B.101 Appliances supplied at rated voltage for 168 h, N/A
the battery being continually charged
19.B.102 For appliances having batteries that can be N/A
removed without the aid of a tool, short-circuit
of the terminals of the battery, the battery
being fully charged,
19.B.103 Appliances having batteries replaceable by the N/A
user supplied at rated voltage under normal
operation with the battery removed or in any
position allowed by the construction
19.13 The battery does not rupture or ignite N/A
21.B.101 Appliances having pins for insertion into N/A
socket-outlets have adequate mechanical
strength
Part of the appliance incorporating the pins subjected to the free fall test, N/A
procedure 2, of IEC 60068-2-31, the number of falls being:
- 100, if the mass of the part does not exceed N/A
250 g (g)...................................................................... :
- 50, if the mass of the part exceeds 250 g........ : N/A
After the test, the requirements of 8.1, 15.1.1, N/A
16.3 and clause 29 are met
22.3 Appliances having pins for insertion into N/A
socket-outlets tested as fully assembled as
possible
25.13 An additional lining or bushing not required for N/A
interconnection cords in class III appliances or
class III constructions operating at safety
extra-low voltage not containing live parts
30.2 For parts of the appliance connected to the N/A
supply mains during the charging period,
30.2.3 applies
For other parts, 30.2.2 applies N/A

TRF No. IEC60335_2_9M


Page 203 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

C ANNEX C (NORMATIVE) N/A


AGEING TEST ON MOTORS
Tests, as described, carried out when doubt N/A
with regard to the temperature classification of
the insulation of a motor winding
The value of p in Table C.1 is 2000 (IEC 60335- N/A
2-9)
D ANNEX D (NORMATIVE) N/A
THERMAL MOTOR PROTECTORS
Applicable to appliances having motors that N/A
incorporate thermal motor protectors
necessary for compliance with the standard
Test conditions as specified N/A
E ANNEX E (NORMATIVE) N/A
NEEDLE-FLAME TEST
Needle-flame test carried out in accordance with IEC 60695- 11-5, with the N/A
following modifications:
7 Severities N/A
The duration of application of the test flame is N/A
30 s ± 1 s
9 Test procedure N/A
9.1 The specimen so arranged that the flame can N/A
be applied to a vertical or horizontal edge as
shown in the examples of Figure 1
9.2 The first paragraph does not apply N/A
If possible, the flame is applied at least 10 mm N/A
from a corner
9.3 The test is carried out on one specimen N/A
If the specimen does not withstand the test, the N/A
test may be repeated on two additional
specimens, both withstanding the test
11 Evaluation of test results N/A
The duration of burning not exceeding 30 s N/A
However, for printed circuit boards, the N/A
duration of burning not exceeding 15 s
F ANNEX F (NORMATIVE) N/A
CAPACITORS
Capacitors likely to be permanently subjected to the supply voltage, and used N/A
for radio interference suppression or voltage dividing, comply with the
following clauses of IEC 60384-14, with the following modifications:

TRF No. IEC60335_2_9M


Page 204 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

1.5 Terms and definitions N/A


1.5.3 Class X capacitors tested according to N/A
subclass X2
1.5.4 This subclause is applicable N/A
1.6 Marking N/A
Items a) and b) are applicable N/A
3.4 Approval testing N/A
3.4.3.2 Table 3 is applicable as described N/A
4.1 Visual examination and check of dimensions N/A
This subclause is applicable N/A
4.2 Electrical tests N/A
4.2.1 This subclause is applicable N/A
4.2.5 This subclause is applicable N/A
4.2.5.2 Only table 11 is applicable N/A
Values for test A apply N/A
However, for capacitors in heating appliances N/A
the values for test B or C apply
4.12 Damp heat, steady state N/A
This subclause is applicable N/A
Only insulation resistance and voltage proof N/A
are checked
4.13 Impulse voltage N/A
This subclause is applicable N/A
4.14 Endurance N/A
Subclauses 4.14.1, 4.14.3, 4.14.4 and 4.14.7 are N/A
applicable
4.14.7 Only insulation resistance and voltage proof N/A
are checked
No visible damage N/A
4.17 Passive flammability test N/A
This subclause is applicable N/A
4.18 Active flammability test N/A
This subclause is applicable N/A
G ANNEX G (NORMATIVE) N/A
SAFETY ISOLATING TRANSFORMERS

TRF No. IEC60335_2_9M


Page 205 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

The following modifications to this standard are applicable for safety N/A
isolating transformers:
7 Marking and instructions N/A
7.1 Transformers for specific use marked with: N/A
-name, trademark or identification mark of the N/A
manufacturer or responsible vendor.................. :
-model or type reference........................................ : N/A
17 Overload protection of transformers and associated circuits N/A
Fail-safe transformers comply with subclause N/A
15.5 of IEC 61558-1
22 Construction N/A
Subclauses 19.1 and 19.1.2 of IEC 61558-2-6 N/A
are applicable
29 Clearances, creepage distances and solid insulation N/A
29.1, 29.2, The distances specified in items 2a, 2c and 3 in N/A
29.3 table 13 of IEC 61558-1 apply
For insulated winding wires complying with N/A
subclause 19.12.3 of IEC 61558-1 there are no
requirements for clearances or creepage
distances
For windings providing reinforced insulation, N/A
the distance specified in item 2c of table 13 of
IEC 61558-1 is not assessed
For safety isolating transformers subjected to N/A
periodic voltages with a frequency exceeding
30 kHz, the clearances, creepage distances and
solid insulation values specified in IEC 60664-4
are applicable, if greater than the values
specified in items 2a, 2c and 3 in table 13 of
IEC 61558-1
H ANNEX H (NORMATIVE) N/A
SWITCHES
Switches comply with the following clauses of IEC 61058-1, as modified N/A
below:
The tests of IEC 61058-1 carried out under the N/A
conditions occurring in the appliance
Before being tested, switches are operated 20 N/A
times without load
8 Marking and documentation N/A
Switches are not required to be marked N/A

TRF No. IEC60335_2_9M


Page 206 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

However, a switch that can be tested N/A


separately from the appliance marked with the
manufacturer’s name or trade mark and the
type reference
13 Mechanism N/A
The tests may be carried out on a separate N/A
sample
15 Insulation resistance and dielectric strength N/A
15.1 Not applicable N/A
15.2 Not applicable N/A
15.3 Applicable for full disconnection and micro- N/A
disconnection
17 Endurance N/A
Compliance is checked on three separate N/A
appliances or switches
For 17.2.4.4, the number of cycles declared N/A
according to 7.1.4 is 10 000, unless
otherwise specified in 24.1.3 of the relevant N/A
part 2 of IEC 60335................................................... :
Switches for operation under no load and N/A
which can be operated only by a tool, and
switches operated by hand that are interlocked N/A
so that they cannot be operated under load,
are not subjected to the tests N/A
However, switches without this interlock are N/A
subjected to the test of 17.2.4.4 for 100 cycles
of operation
Subclauses 17.2.2 and 17.2.5.2 not applicable N/A
The ambient temperature during the test is that N/A
occurring in the appliance during the test of
Clause 11 in IEC 60335-1
The temperature rise of the terminals not more N/A
than 30 K above the temperature rise measured
in clause 11 of IEC 60335-1 (K)............................. :
20 Clearances, creepage distances, solid insulation and coatings of rigid printed N/A
board assemblies
Clause 20 is applicable to clearances across N/A
full disconnection and micro-disconnection

TRF No. IEC60335_2_9M


Page 207 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

It is also applicable to creepage distances for N/A


functional insulation, across full disconnection
and micro-disconnection, as stated in Table 24
I ANNEX I (NORMATIVE) N/A
MOTORS HAVING BASIC INSULATION THAT IS INADEQUATE FOR THE
RATED VOLTAGE OF THE APPLIANCE
The following modifications to this standard are applicable for motors having N/A
basic insulation that is inadequate for the rated voltage of the appliance:
8 Protection against access to live parts N/A
8.1 Metal parts of the motor are considered to be N/A
bare live parts
11 Heating N/A
11.3 The temperature rise of the body of the motor N/A
is determined instead of the temperature rise of
the windings
11.8 The temperature rise of the body of the motor, N/A
where in contact with insulating material, not
exceeding values in table 3 for the relevant
insulating material
16 Leakage current and electric strength N/A
16.3 Insulation between live parts of the motor and N/A
its other metal parts is not subjected to the test
19 Abnormal operation N/A
19.1 The tests of 19.7 to 19.9 are not carried out N/A
19.I.101 Appliance operated at rated voltage with each of the following fault N/A
conditions:
- short circuit of the terminals of the motor, N/A
including any capacitor incorporated in the
motor circuit
- short circuit of each diode of the rectifier N/A
- open circuit of the supply to the motor N/A
- open circuit of any parallel resistor, the motor N/A
being in operation
Only one fault simulated at a time, the tests N/A
carried out consecutively
22 Construction N/A
22.I.101 For class I appliances incorporating a motor N/A
supplied by a rectifier circuit, the d.c. circuit
being insulated from accessible parts of the
appliance by double or reinforced insulation

TRF No. IEC60335_2_9M


Page 208 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Compliance checked by the tests specified for N/A


double and reinforced insulation
J ANNEX J (NORMATIVE) N/A
COATED PRINTED CIRCUIT BOARDS
Testing of protective coatings of printed circuit boards carried out in N/A
accordance with IEC 60664-3 with the following modifications:
5.7 Conditioning of the test specimens N/A
When production samples are used, three N/A
samples of the printed circuit board are tested
5.7.1 Cold N/A
The test is carried out at -25 C N/A
5.7.3 Rapid change of temperature N/A
Severity 1 is specified N/A
5.9 Additional tests N/A
This subclause is not applicable N/A
K ANNEX K (NORMATIVE) P
OVERVOLTAGE CATEGORIES
The information on overvoltage categories is P
extracted from IEC 60664-1
Overvoltage category is a numeral defining a P
transient overvoltage condition
Equipment of overvoltage category IV is for N/A
use at the origin of the installation
Equipment of overvoltage category III is N/A
equipment in fixed installations and for cases
where the reliability and the availability of the
equipment is subject to special requirements
Equipment of overvoltage category II is energy P
consuming equipment to be supplied from the
fixed installation
If such equipment is subjected to special N/A
requirements with regard to reliability and
availability, overvoltage category III applies
Equipment of overvoltage category I is N/A
equipment for connection to circuits in which
measures are taken to limit transient
overvoltages to an appropriate low level
L ANNEX L (INFORMATIVE) P
GUIDANCE FOR THE MEASUREMENT OF CLEARANCES AND CREEPAGE
DISTANCES

TRF No. IEC60335_2_9M


Page 209 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Information for the determination of clearances P


and creepage distances
M ANNEX M (NORMATIVE) P
POLLUTION DEGREE
The information on pollution degrees is P
extracted from IEC 60664-1
Pollution P
The microenvironment determines the effect of P
pollution on the insulation, taking into account
the macroenvironment
Means may be provided to reduce pollution at P
the insulation by effective enclosures or similar
Minimum clearances specified where pollution P
may be present in the microenvironment
Degrees of pollution in the microenvironment P
For evaluating creepage distances, the following degrees of pollution in the P
microenvironment are established:
- pollution degree 1: no pollution or only dry, N/A
non-conductive pollution occurs. The pollution
has no influence
- pollution degree 2: only non-conductive P
pollution occurs, except that occasionally a
temporary conductivity caused by
condensation is to be expected
- pollution degree 3: conductive pollution N/A
occurs or dry non-conductive pollution occurs
that becomes conductive due to condensation
that is to be expected
- pollution degree 4: the pollution generates N/A
persistent conductivity caused by conductive
dust or by rain or snow
N ANNEX N (NORMATIVE) P
PROOF TRACKING TEST
The proof tracking test is carried out in accordance with IEC 60112 with the P
following modifications:
7 Test apparatus P
7.3 Test solutions P
Test solution A is used P
10 Determination of proof tracking index (PTI) P
10.1 Procedure P

TRF No. IEC60335_2_9M


Page 210 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

The proof voltage is 100V, 175V, 400V or 600V: 175V P


The test is carried out on five specimens P
In case of doubt, additional test with proof N/A
voltage reduced by 25V, the number of drops
increased to 100
10.2 Report P
The report states if the PTI value was based on N/A
a test using 100 drops with a test voltage of
(PTI-25) V
O ANNEX O (INFORMATIVE) P
SELECTION AND SEQUENCE OF THE TESTS OF CLAUSE 30
Description of tests for determination of P
resistance to heat and fire
P ANNEX P (INFORMATIVE) N/A
GUIDANCE FOR THE APPLICATION OF THIS STANDARD TO APPLIANCES
USED IN WARM DAMP EQUABLE CLIMATES
Modifications applicable for class 0 and 01 appliances having a rated voltage N/A
exceeding 150V, intended to be used in countries having a warm damp
equable climate and that are marked WDaE
Modifications may also be applied to class 1 appliances having a rated N/A
voltage exceeding 150V, intended to be used in countries having a warm
damp equable climate and that are marked WdaE, if liable to be connected to
a supply mains that excludes the protective earthing conductor
5.7 The ambient temperature for the tests of N/A
clauses 11 and 13 is 40 +3/0 C
7.1 The appliance marked with the letters WDaE N/A
7.12 The instructions state that the appliance is to N/A
be supplied through a residual current device
(RCD) having a rated residual operating current
not exceeding 30 mA
The instructions state that the appliance is N/A
considered to be suitable for use in countries
having a warm damp equable climate, but may
also be used in other countries
11.8 The values of Table 3 are reduced by 15 K N/A
13.2 The leakage current for class I appliances not N/A
exceeding 0,5 mA
15.3 The value of t is 37 C N/A
16.2 The leakage current for class I appliances not N/A
exceeding 0,5 mA (mA):

TRF No. IEC60335_2_9M


Page 211 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

19.13 The leakage current test of 16.2 is applied in N/A


addition to the electric strength test of 16.3
Q ANNEX Q (INFORMATIVE) N/A
SEQUENCE OF TESTS FOR THE EVALUATION OF ELECTRONIC CIRCUITS
Description of tests for appliances incorporating electronic circuits N/A
R ANNEX R (NORMATIVE) N/A
SOFTWARE EVALUATION
Programmable electronic circuits requiring N/A
software incorporating measures to control the
fault/error conditions specified in table R.1 or
R.2 validated in accordance with the
requirements of this annex
R.1 Programmable electronic circuits using software N/A
Programmable electronic circuits requiring N/A
software incorporating measures to control the
fault/error conditions specified in table R.1 or
R.2 constructed so that the software does not
impair compliance with the requirements of
this standard
R.2 Requirements for the architecture N/A
Programmable electronic circuits requiring N/A
software incorporating measures to control the
fault/error conditions specified in table R.1 or
R.2 use measures to control and avoid
software-related faults/errors in safety-related
data and safety-related segments of the
software
R.2.1.1 Programmable electronic circuits requiring software incorporating measures N/A
to control the fault/error conditions specified in table R.2 have one of the
following structures:
- single channel with periodic self-test and N/A
monitoring
- dual channel (homogenous) with comparison N/A
- dual channel (diverse) with comparison N/A
Programmable electronic circuits requiring software incorporating measures N/A
to control the fault/error conditions specified in table R.1 have one of the
following structures:
- single channel with functional test N/A
- single channel with periodic self-test N/A
- dual channel without comparison N/A
R.2.2 Measures to control faults/errors N/A

TRF No. IEC60335_2_9M


Page 212 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

R.2.2.1 When redundant memory with comparison is N/A


provided on two areas of the same component,
the data in one area is stored in a different
format from that in the other area
R.2.2.2 Programmable electronic circuits with N/A
functions requiring software incorporating
measures to control the fault/error conditions
specified in table R.2 and that use dual channel
structures with comparison, have additional
fault/error detection means for any fault/errors
not detected by the comparison
R.2.2.3 For programmable electronic circuits with N/A
functions requiring software incorporating
measures to control the fault/error conditions
specified in table R.1 or R.2, means are
provided for the recognition and control of
errors in transmissions to external safety-
related data paths
R.2.2.4 For programmable electronic circuits with N/A
functions requiring software incorporating
measures to control the fault/error conditions
specified in table R.1 or R.2, the programmable
electronic circuits incorporate measures to
address the fault/errors in safety-related
segments and data indicated in table R.1 and
R.2 as appropriate
R.2.2.5 For programmable electronic circuits with N/A
functions requiring software incorporating
measures to control the fault/error conditions
specified in table R.1 or R.2, detection of a
fault/error occur before compliance with clause
19 and 22.115 is impaired (IEC 60335-2-9)
R.2.2.6 The software is referenced to relevant parts of N/A
the operating sequence and the associated
hardware functions
R.2.2.7 Labels used for memory locations are unique N/A
R.2.2.8 The software is protected from user alteration N/A
of safety-related segments and data
R.2.2.9 Software and safety-related hardware under its N/A
control is initialized and terminates before
compliance with clause 19 and 22.115 is
impaired (IEC 60335-2-9)
R.3 Measures to avoid errors N/A
R.3.1 General N/A

TRF No. IEC60335_2_9M


Page 213 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

For programmable electronic circuits with functions requiring software N/A


incorporating measures to control the fault/error conditions specified in table
R.1 or R.2, the following measures to avoid systematic fault in the software
are applied
Software that incorporates measures used to N/A
control the fault/error conditions specified in
table R.2 is inherently acceptable for software
required to control the fault/error conditions
specified in table R.1
R.3.2 Specification N/A
R.3.2.1 Software safety requirements: Software Id: N/A
The specification of the software safety N/A
requirements includes the descriptions listed
R.3.2.2 Software architecture N/A
R.3.2.2.1 The specification of the software architecture Document ref. No: N/A
includes the aspects listed
- techniques and measures to control software
faults/errors (refer to R.2.2);
- interactions between hardware and software;
- partitioning into modules and their allocation
to the specified safety functions;
- hierarchy and call structure of the modules
(control flow);
- interrupt handling;
- data flow and restrictions on data access;
- architecture and storage of data;
- time-based dependencies of sequences and
data
R.3.2.2.2 The architecture specification is validated N/A
against the specification of the software safety
requirements by static analysis
R.3.2.3 Module design and coding N/A
R.3.2.3.1 Based on the architecture design, software is N/A
suitably refined into modules
Software module design and coding is N/A
implemented in a way that is traceable to the
software architecture and requirements
R.3.2.3.2 Software code is structured N/A
R.3.2.3.3 Coded software is validated against the module N/A
specification by static analysis
The module specification is validated against N/A
the architecture specification by static analysis

TRF No. IEC60335_2_9M


Page 214 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

R.3.3.3 Software validation N/A


The software is validated with reference to the N/A
requirements of the software safety
requirements specification
Compliance is checked by simulation of: N/A
- input signals present during normal operation N/A
- anticipated occurrences N/A
- undesired conditions requiring system action N/A

TABLE R.1 e – GENERAL FAULT/ERROR CONDITIONS


Component Fault/error Acceptable measures b, c Definitions Document Document Ver-
a
reference reference dict
for applied for applied
measure test
1 CPU N/A
1.1
Registers Stuck at Functional test, or H.2.16.5
periodic self-test using either: H.2.16.6
- static memory test, or H.2.19.6
- word protection with H.2.19.8.2
single bit redundancy
1.2 VOID N/A
1.3 Stuck at Functional test, or H.2.16.5 N/A
Programme Periodic self-test, or H.2.16.6
counter
Independent time-slot H.2.18.10.4
monitoring, or
Logical monitoring of the H.2.18.10.2
programme sequence
2 No Functional test, or H.2.16.5 N/A
Interrupt interrupt or time-slot monitoring H.2.18.10.4
handling too
and frequent
execution interrupt
3 Wrong Frequency monitoring, or H.2.18.10.1 N/A
Clock frequency time slot monitoring H.2.18.10.4
(for quartz
synchroniz
ed clock:
harmonics/
sub-
harmonics
only)

TRF No. IEC60335_2_9M


Page 215 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

4. Memory N/A
4.1 All single Periodic modified checksum, or H.2.19.3.1
Invariable bit faults multiple checksum, or H.2.19.3.2
memory
word protection with single bit H.2.19.8.2
redundancy
4.2 DC fault Periodic static memory test, or H.2.19.6 N/A
Variable word protection with single bit H.2.19.8.2
memory redundancy

4.3 Stuck at Word protection with single bit H.2.19.8.2 N/A


Addressing redundancy including the
(relevant to address
variable and
invariable
memory)
5 Stuck at Word protection with single bit H.2.19.8.2 N/A
Internal redundancy
data path
5.1 VOID N/A
5.2 Wrong Word protection with single bit H.2.19.8.2 N/A
Addressing address redundancy including the
address
6 Hamming Word protection with multi-bit H.2.19.8.1 N/A
External distance 3 redundancy, or
communicat CRC – single work, or H.2.19.4.1
ion
Transfer redundancy, or H.2.18.2.2
Protocol test H.2.18.14
6.1 VOID N/A
6.2 VOID N/A
6.3 Wrong Time-slot monitoring, or H.2.18.10.4 N/A
Timing point in scheduled transmission H.2.18.18
time
Time-slot and logical H.2.18.10.3
monitoring, or
comparison of redundant
communication channels by
either:
- reciprocal comparison H.2.18.15
- independent hardware H.2.18.3
comparator
Wrong Logical monitoring, or H.2.18.10.2
sequence time-slot monitoring, or H.2.18.10.4
Scheduled transmission H.2.18.18

TRF No. IEC60335_2_9M


Page 216 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

7 Fault Plausibility check H.2.18.13 N/A


Input/output conditions
periphery specified in
19.11.2
7.1 VOID N/A
7.2 N/A
Analog I/O
7.2.1 Fault Plausibility check H.2.18.13
A/D and conditions
D/A- specified in
converter 19.11.2
7.2.2 Wrong Plausibility check H.2.18.13 N/A
Analog addressing
multiplexer
8 VOID N/A
9 Any output Periodic self-test H.2.16.6 N/A
Custom outside the
chips d e.g. static and
ASIC, GAL, dynamic
gate array functional
specificatio
n
NOTE A Stuck-at fault model denotes a fault model representing an open circuit or a non-varying signal
level. A DC fault model denotes a stuck-at fault model incorporating short circuit between signal lines.
a)
For fault/error assessment, some components are divided into their sub-functions.
b)
For each sub-function in the table, the Table R.2 measure will cover the software fault/error.
c)
Where more than one measure is given for a sub-function, these are alternatives.
d)
To be divided as necessary by the manufacturer into sub-functions.
e)
Table R.1 is applied according to the requirements of R.1 to R.2.2.9 inclusive.

TRF No. IEC60335_2_9M


Page 217 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

S ANNEX S (NORMATIVE) N/A


BATTERY OPERATED APPLIANCES POWERED BY BATTERIES THAT ARE
NON-RECHARGEABLE OR NOT RECHARGED IN THE APPLIANCE
The following modifications to this standard are N/A
applicable for battery-operated appliances
where the batteries are either non-rechargeable
(primary batteries), or
rechargeable batteries (secondary batteries) N/A
that are not recharged in the appliance
5.8.1 If the supply terminals for the connection of the N/A
battery have no indication of polarity, the more
unfavourable polarity is applied
5.S.101 Appliances intended for use with a battery box N/A
are tested with the battery box supplied with the
appliance or with the battery box recommended
in the instructions
5.S.102 Appliances are tested as motor-operated N/A
appliances.
7.1 Appliances marked with the battery voltage (V) N/A
and the polarity of the terminals, unless ...........:
the polarity is irrelevant N/A
Appliances also marked with: N/A
– name, trade mark or identification mark of the N/A
manufacturer or responsible vendor..................:
– model or type reference......................................: N/A
– IP number according to degree of protection N/A
against ingress of water, other than IPX0......... :
– type reference of battery or batteries..............: N/A
If relevant, the positive terminal is indicated by N/A
the symbol IEC 60417-5005 and the negative
terminal by the symbol IEC 60417-5006
If appliances use more than one battery, they N/A
are marked to indicate correct polarity
connection of the batteries
7.6 Additional symbols N/A
7.12 The instructions contain the following, as applicable: N/A
– the types of batteries that may be used......... : N/A
– how to remove and insert the batteries N/A
– non-rechargeable batteries are not to be N/A
recharged

TRF No. IEC60335_2_9M


Page 218 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

– rechargeable batteries are to be removed from N/A


the appliance before being charged
– different types of batteries or new and used N/A
batteries are not to be mixed
– batteries are to be inserted with the correct N/A
polarity
– exhausted batteries are to be removed from N/A
the appliance and safely disposed of
– if the appliance is to be stored unused for a N/A
long period, the batteries are removed
– the supply terminals are not to be short- N/A
circuited
11.5 Appliances are supplied with the most unfavourable supply voltage between N/A
– 0,55 and 1,0 times the battery voltage, if the N/A
appliance can be used with non-rechargeable
batteries
– 0,75 and 1,0 times battery voltage, if the N/A
appliance is designed for use with rechargeable
batteries only
The values specified in Table S.101 for the N/A
internal resistance per cell of the battery is
taken into account
19.1 The tests are carried out with the battery fully N/A
charged unless otherwise specified
19.13 The battery does not rupture or ignite N/A
19.S.101 Appliances are supplied with the voltage N/A
specified in 11.5. The supply terminals having
an indication of polarity are connected to the
opposite polarity, unless
such a connection is unlikely to occur due to N/A
the construction of the appliance
19.S.102 For appliances with provision for multiple N/A
batteries, one or more of the batteries are
reversed and the appliance is operated, if
reversal of batteries is allowed by the
construction
25.5 The flexible leads or flexible cord used to N/A
connect an external battery or battery box in is
connected to the appliance by a type X
attachment

TRF No. IEC60335_2_9M


Page 219 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

25.13 This requirement is not applicable to the N/A


flexible leads or flexible cord connecting
external batteries or a battery box with an
appliance
25.S.101 Appliances have suitable means for connection N/A
of the battery. If the type of battery is marked on
the appliance, the means of connection is
suitable for this type of battery
26.5 Terminal devices in an appliance for the N/A
connection of the flexible leads or flexible cord
connecting an external battery or battery box
are so located or shielded that there is no risk
of accidental connection between supply
terminals
30.2.3.2 There is no battery in the area of the vertical N/A
cylinder used for the consequential needle
flame test, unless
the battery is shielded by a barrier that meets N/A
the needle flame test of Annex E, or
that comprises material classified as V-0 or V-1 N/A
according to IEC 60695-11-10

TRF No. IEC60335_2_9M


Page 220 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

10.1 TABLE: Power input deviation P


Input deviation of/at: P rated (W) P measured (W) dP Required dP Remark
(W, %) (W, %)
HK-P55RCL 3000 2910,9 -3,0% -10%,+5% 230V 50Hz
HK-P55RCL 3000 2905,2 -3,2% -10%,+5% 230V 60Hz
HK-12002 2800 2710,6 -3,2% -10%,+5% 230V 50Hz
HK-12002 2800 2708,4 -3,3% -10%,+5% 230V 60Hz
HK-65RCL 2500 2435,4 -2,6% -10%,+5% 230V 50Hz
HK-65RCL 2500 2425,6 -3,0% -10%,+5% 230V 60Hz
HK-P34RCL 2400 2324,4 -3,2% -10%,+5% 230V 50Hz
HK-P34RCL 2400 2321,5 -3,3% -10%,+5% 230V 60Hz
HK-P24RCL 2300 2254,1 -2,0% -10%,+5% 230V 50Hz
HK-P24RCL 2300 2246,8 -2,3% -10%,+5% 230V 60Hz
HK-7501RCL 2200 2114,6 -3,9% -10%,+5% 230V 50Hz
HK-7501RCL 2200 2105,8 -4,3% -10%,+5% 230V 60Hz
HK-6009RCL 2000 1935,2 -3,2% -10%,+5% 230V 50Hz
HK-6009RCL 2000 1930,5 -3,5% -10%,+5% 230V 60Hz
HK-5008RCL 1800 1744,6 -3,1% -10%,+5% 230V 50Hz
HK-5008RCL 1800 1735,2 -3,6% -10%,+5% 230V 60Hz
HK-4803RCL 1600 1541,6 -3,7% -10%,+5% 230V 50Hz
HK-4803RCL 1600 1538,2 -3,9% -10%,+5% 230V 60Hz
HK-3406 1500 1442,5 -3,8% -10%,+5% 230V 50Hz
HK-3406 1500 1437,8 -4,1% -10%,+5% 230V 60Hz
HK-2802RCL 1380 1342,5 -2,7% -10%,+5% 230V 50Hz
HK-2802RCL 1380 1326,8 -3,9% -10%,+5% 230V 60Hz
HK-15 1200 1145,2 -4,6% -10%,+5% 230V 50Hz
HK-15 1200 1138,6 -5,1% -10%,+5% 230V 60Hz
HK-1201 1000 945,2 -5,5% -10%,+5% 230V 50Hz
HK-1201 1000 936,8 -6,3% -10%,+5% 230V 60Hz
HK-0906A3T 800 754,2 -5,7% -10%,+5% 230V 50Hz
HK-0906A3T 800 749,5 -6,3% -10%,+5% 230V 60Hz
HK-09TM 800 752,5 -5,9% -10%,+5% 230V 50Hz
HK-09TM 800 747,6 -6,6% -10%,+5% 230V 60Hz

TRF No. IEC60335_2_9M


Page 221 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Supplementary information:

11.8-A TABLE: Heating test, thermocouple measurements (HK-P55RCL) P


Test voltage (V)...........................................................: 262,3 
Ambient (C)................................................................ : t1: 22,8 to t2: 22,0 
Thermocouple locations Max. temperature rise measured, Max.temperature rise limit,
dT (K) dT (K)
The power cord fork mouth 25,9 50
The internal line of 52,1 175(T200)
Lamp holder (ceramic) 138,5 145(T170)
synchronous motor 50,6 140
shaded pole motor 45,7 140
test side wall 18,8 150
Test Angle plate 13,1 150
Metal case 87,5 Cl,25
The handle 32,4 35
Knob 31,6 60
The thermostat on environment around 74,3 225(T250)
The thermostat environment around 126,1 225(T250)
Supplementary information:

11.8-B TABLE: Heating test, thermocouple measurements (HX-P55) P


Test voltage (V)...........................................................: 262,3 
Ambient (C)................................................................ : t1: 22,7 to t2: 22,0 
Thermocouple locations Max. temperature rise measured, Max.temperature rise limit,
dT (K) dT (K)
The power cord fork mouth 25,5 50
The internal line of 52,4 175(T200)
test side wall 18,4 150
Test Angle plate 12,2 150
Metal case 86,9 Cl,25
The handle 31,5 35
Knob 30,8 60

TRF No. IEC60335_2_9M


Page 222 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

The thermostat on environment around 73,1 225(T250)


The thermostat environment around 124,5 225(T250)
Supplementary information:

11.8-C TABLE: Heating test, thermocouple measurements (HX-P55R) P


Test voltage (V)...........................................................: 262,3 
Ambient (C)................................................................ : t1: 22,4 to t2: 22,0 
Thermocouple locations Max. temperature rise measured, Max.temperature rise limit,
dT (K) dT (K)
The power cord fork mouth 24,4 50
The internal line of 51,5 175(T200)
synchronous motor 48,2 140
test side wall 17,6 150
Test Angle plate 12,2 150
Metal case 86,9 Cl,25
The handle 31,5 35
Knob 32,3 60
The thermostat on environment around 73,1 225(T250)
The thermostat environment around 121,5 225(T250)
Supplementary information:

11.8-D TABLE: Heating test, thermocouple measurements (HK-P55C) P


Test voltage (V)...........................................................: 262,3 
Ambient (C)................................................................ : t1: 22,5 to t2: 22,0 
Thermocouple locations Max. temperature rise measured, Max.temperature rise limit,
dT (K) dT (K)
The power cord fork mouth 24,8 50
The internal line of 51,2 175(T200)
shaded pole motor 44,6 140
test side wall 17,7 150
Test Angle plate 12,9 150
Metal case 86,1 Cl,25
The handle 31,8 35

TRF No. IEC60335_2_9M


Page 223 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Knob 30,2 60
The thermostat on environment around 73,9 225(T250)
The thermostat environment around 122,5 225(T250)
Supplementary information:

11.8-F TABLE: Heating test, thermocouple measurements (HK-09TM) P


Test voltage (V)...........................................................: 262,3 
Ambient (C)................................................................ : t1: 22,1 to t2: 22,0 
Thermocouple locations Max. temperature rise measured, Max.temperature rise limit,
dT (K) dT (K)
The power cord fork mouth 21,4 50
The internal line of 48,7 175(T200)
test side wall 16,2 150
Test Angle plate 11,8 150
Metal case 84,2 Cl,25
The handle 32,4 35
Knob 31,4 60
Supplementary information:

11.102 TABLE: Heating test, thermocouple measurements (HK-09TM) P


Test voltage (V)...........................................................: 230,0 
Ambient (C)................................................................ : t1: 22,1 to t2: 22,0 
Thermocouple locations Max. temperature rise measured, Max.temperature rise limit,
dT (K) dT (K)
Coated metal 49,5 55
Glass 56,7 60
Supplementary information:

13.2 TABLE: Leakage current P


Heating appliances: 1.15 x rated input (W)........: 3756,5W 
Motor-operated and combined appliances: / 
1.06 x rated voltage (V).........................................:
Leakage current between I (mA) Max. allowed I (mA)
Any pole of the supply and metal foil for classⅡ construction 0,042/0,040 0,35peak

TRF No. IEC60335_2_9M


Page 224 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Any pole of the supply and accessible earthing parts 0,036/0,034 0,75
Supplementary information:

13.3 TABLE: Electric strength P


Test voltage applied between: Voltage (V) Breakdown
(Yes/No)
Live part and accessible parts (reinforced insulation) 3000 No

Live part and accessible parts (basic insulation) 1000 No

Supplementary information:

14 TABLE: Transient overvoltages N/A


Clearance between: Cl (mm) Required Cl Rated Impulse test Flashover
(mm) impulse voltage (V) (Yes/No)
voltage (V)
N/A

Supplementary information: N/A

16.2 TABLE: Leakage current P


Single phase appliances: 1.06 x rated voltage (V) 254,4 
.................................................................................. :

Three phase appliances 1.06 x rated voltage / 


divided by 3 (V).................................................... :
Leakage current between I (mA) Max. allowed I (mA)
Live part and metal foil for classⅡ construction 0,072 0,25
Live part and accessible earthing parts 0,065 0,75
Supplementary information:

16.3 TABLE: Electric strength P


Test voltage applied between: Voltage (V) Breakdown
(Yes/No)

Live part and accessible parts (reinforced insulation) 3000 No

Live part and accessible parts (basic insulation) 1250 No

Supplementary information:

TRF No. IEC60335_2_9M


Page 225 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

17 TABLE: Overload protection, thermocouple measurements N/A


Temperature rise of part/at: dT (K) Max. dT (K)
N/A

Supplementary information:

17 TABLE: Overload protection, resistance method P


Test voltage (V)...........................................................: 
Ambient, t1 (C).......................................................... : 
Ambient, t2 (C).......................................................... : 
Temperature of winding R1 (Ω) R2 (Ω) dT (K) T (C) Max. T (°C)

Supplementary information:

19 Abnormal operation conditions P


Operational characteristics YES/NO Operational conditions
Are there electronic circuits to YES There are electronic circuits to control the
control the appliance operation? appliance operation of time and
temperature.
Are there “off” or “stand-by” YES There are “stand-by” position
position?
The unintended operation of the NO 230V
appliance results in dangerous
malfunction?
Sub- Operating Test results PEC EMP Software 19.11.3 Final
clause conditions description description 19.11.4 type PEC result
description required
19.2 Heating Steady N/A N/A N/A N/A P
elements with conditions
restricted heat has been
dissipation. established.
Temperature
rise is lower
than limit.
19.3 Heating Steady N/A N/A N/A N/A P
elements with conditions

TRF No. IEC60335_2_9M


Page 226 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

restricted heat has been


dissipation. established.
Temperature
rise is lower
than limit.
19.4 Tested as in No hazard N/A N/A N/A N/A P
condition of observed,
Cl.11 with measured
thermostats temperature
short- below limit
circuited.
19.5 Each end of No hazard N/A N/A N/A N/A P
the element observed,
connected to measured
the sheath temperature
separately below limit
19.6 N/A N/A N/A N/A N/A N/A N/A
19.7 Heating Steady N/A N/A N/A N/A P
elements with conditions
restricted heat has been
dissipation. established.
Temperature
rise is lower
than limit.
19.8 N/A N/A N/A N/A N/A N/A N/A
19.9 N/A N/A N/A N/A N/A N/A N/A
19.10 N/A N/A N/A N/A N/A N/A N/A
19.11.2 N/A N/A N/A N/A N/A N/A N/A
19.11.4.8 N/A N/A N/A N/A N/A N/A N/A
19.104 N/A N/A N/A N/A N/A N/A N/A
19.105 N/A N/A N/A N/A N/A N/A N/A
Supplementary information: N/A

19.2-A TABLE: Abnormal operation, temperature rises(HK-P55RCL) P


t1=..........................................................................: (℃) 22,5
t2=..........................................................................: (℃) 22,0
Thermocouple locations Max. temperature rise Max. temperature rise
measured, Δ T (K) limit, Δ T (K)
The power cord fork mouth 26,6 150
test side wall 13,1 150
Test Angle plate 25,9 150

TRF No. IEC60335_2_9M


Page 227 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Knob 69,1 Cl,30


N/A
Supplementary information: N/A

19.3-A TABLE: Abnormal operation, temperature rises(HK-P55RCL) P


t1=..........................................................................: (℃) 21,5
t2=..........................................................................: (℃) 22,0
Thermocouple locations Max. temperature rise Max. temperature rise
measured, Δ T (K) limit, Δ T (K)
The power cord fork mouth 27,0 150
test side wall 11,9 150
Test Angle plate 26,0 150
Knob 68,3 Cl,30
N/A
Supplementary information: N/A

19.4-A TABLE: Abnormal operation, temperature rises(HK-P55RCL) P


t1=..........................................................................: (℃) 22,1
t2=..........................................................................: (℃) 22,0
Thermocouple locations Max. temperature rise Max. temperature rise
measured, Δ T (K) limit, Δ T (K)
The power cord fork mouth 62,0 150
test side wall 49,4 150
Test Angle plate 91,2 150
Knob 15,1 Cl,30
N/A
Supplementary information: N/A

19.7-A TABLE: Abnormal operation, temperature rises(HK-P55RCL) P


t1=..........................................................................: (℃) 22,2
t2=..........................................................................: (℃) 22,0
Thermocouple locations Max. temperature rise Max. temperature rise
measured, Δ T (K) limit, Δ T (K)
The power cord fork mouth 70,2 150

TRF No. IEC60335_2_9M


Page 228 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

test side wall 48,1 150


Test Angle plate 28,5 150
Knob 34,9 Cl,30
synchronous motor 92,6 210
shaded pole motor 65,3 210
N/A
Supplementary information: N/A

19.2-B TABLE: Abnormal operation, temperature rises(HX-P55) P


t1=..........................................................................: (℃) 22,5
t2=..........................................................................: (℃) 22,0
Thermocouple locations Max. temperature rise Max. temperature rise
measured, Δ T (K) limit, Δ T (K)
The power cord fork mouth 26,1 150
test side wall 13,2 150
Test Angle plate 25,5 150
Knob 68,5 Cl,30
N/A
Supplementary information: N/A

19.3-B TABLE: Abnormal operation, temperature rises(HX-P55) P


t1=..........................................................................: (℃) 21,5
t2=..........................................................................: (℃) 22,0
Thermocouple locations Max. temperature rise Max. temperature rise
measured, Δ T (K) limit, Δ T (K)
The power cord fork mouth 27,2 150
test side wall 11,4 150
Test Angle plate 25,2 150
Knob 67,9 Cl,30
N/A
Supplementary information: N/A

19.4-B TABLE: Abnormal operation, temperature rises(HX-P55) P


t1=..........................................................................: (℃) 22,1

TRF No. IEC60335_2_9M


Page 229 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

t2=..........................................................................: (℃) 22,0


Thermocouple locations Max. temperature rise Max. temperature rise
measured, Δ T (K) limit, Δ T (K)
The power cord fork mouth 61,4 150
test side wall 49,1 150
Test Angle plate 90,5 150
Knob 16,2 Cl,30
N/A
Supplementary information: N/A

19.2-C TABLE: Abnormal operation, temperature rises(HX-P55R) P


t1=..........................................................................: (℃) 22,5
t2=..........................................................................: (℃) 22,0
Thermocouple locations Max. temperature rise Max. temperature rise
measured, Δ T (K) limit, Δ T (K)
The power cord fork mouth 26,6 150
test side wall 13,1 150
Test Angle plate 25,9 150
Knob 69,1 Cl,30
N/A
Supplementary information: N/A

19.3-C TABLE: Abnormal operation, temperature rises(HX-P55R) P


t1=..........................................................................: (℃) 21,5
t2=..........................................................................: (℃) 22,0
Thermocouple locations Max. temperature rise Max. temperature rise
measured, Δ T (K) limit, Δ T (K)
The power cord fork mouth 27,2 150
test side wall 11,6 150
Test Angle plate 25,4 150
Knob 67,8 Cl,30
N/A
Supplementary information: N/A

TRF No. IEC60335_2_9M


Page 230 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

19.4-C TABLE: Abnormal operation, temperature rises(HX-P55R) P


t1=..........................................................................: (℃) 22,1
t2=..........................................................................: (℃) 22,0
Thermocouple locations Max. temperature rise Max. temperature rise
measured, Δ T (K) limit, Δ T (K)
The power cord fork mouth 61,5 150
test side wall 49,2 150
Test Angle plate 90,0 150
Knob 16,2 Cl,30
N/A
Supplementary information: N/A

19.7-C TABLE: Abnormal operation, temperature rises(HX-P55R) P


t1=..........................................................................: (℃) 22,3
t2=..........................................................................: (℃) 22,0
Thermocouple locations Max. temperature rise Max. temperature rise
measured, Δ T (K) limit, Δ T (K)
The power cord fork mouth 69,5 150
test side wall 47,0 150
Test Angle plate 27,6 150
Knob 33,7 Cl,30
synchronous motor 91,2 210
N/A
Supplementary information: N/A

19.2-D TABLE: Abnormal operation, temperature rises(HK-P55C) P


t1=..........................................................................: (℃) 22,1
t2=..........................................................................: (℃) 22,0
Thermocouple locations Max. temperature rise Max. temperature rise
measured, Δ T (K) limit, Δ T (K)
The power cord fork mouth 26,2 150
test side wall 12,8 150
Test Angle plate 24,2 150
Knob 67,2 Cl,30
N/A

TRF No. IEC60335_2_9M


Page 231 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Supplementary information: N/A

19.3-D TABLE: Abnormal operation, temperature rises(HK-P55C) P


t1=..........................................................................: (℃) 21,5
t2=..........................................................................: (℃) 22,0
Thermocouple locations Max. temperature rise Max. temperature rise
measured, Δ T (K) limit, Δ T (K)
The power cord fork mouth 25,2 150
test side wall 11,5 150
Test Angle plate 25,2 150
Knob 67,9 Cl,30
N/A
Supplementary information: N/A

19.4-D TABLE: Abnormal operation, temperature rises(HK-P55C) P


t1=..........................................................................: (℃) 22,2
t2=..........................................................................: (℃) 22,0
Thermocouple locations Max. temperature rise Max. temperature rise
measured, Δ T (K) limit, Δ T (K)
The power cord fork mouth 61,1 150
test side wall 48,8 150
Test Angle plate 90,0 150
Knob 14,7 Cl,30
N/A
Supplementary information: N/A

19.7-D TABLE: Abnormal operation, temperature rises(HK-P55C) P


t1=..........................................................................: (℃) 22,1
t2=..........................................................................: (℃) 22,0
Thermocouple locations Max. temperature rise Max. temperature rise
measured, Δ T (K) limit, Δ T (K)
The power cord fork mouth 69,5 150
test side wall 47,2 150
Test Angle plate 27,6 150

TRF No. IEC60335_2_9M


Page 232 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Knob 33,8 Cl,30


synchronous motor 91,8 210
shaded pole motor 64,2 210
N/A
Supplementary information: N/A

21.1 TABLE: Impact resistance P


Impacts per surface Surface tested Impact energy (Nm) Comments
3 Knob 0,5 No damage
3 Enclosure 0,5 No damage
Supplementary information: N/A

24.1 TABLE: Critical components information P


Manufacturer/ Mark(s) of
Object / part No. Type / model Technical data Standard
trademark conformity
Guangdong Kai
Plug(for all Hua Electric VDE
KH-9902 AC250V, 16A VDE 0620-1
model) Appliance Co., 40010410
Ltd.
Plug(for all Sheng Yi VDE
SY-22 AC250V, 16A VDE 0620-1
model) (Alt) Electrical Factory 40007744
Shunde Hanli
Plug(for all Electrical Wire VDE
HL-803 AC250V, 16A VDE 0620-1
model) (Alt) Production Co., 40008076
Ltd.
Plug(for all Zhong Shan AoLi VDE
AL-032A AC250V, 16A VDE 0620-1
model) (Alt) Electrical Co. Ltd. 40033273
Zhongshan
Plug(for all Guzhen Hongli VDE
HL-28 AC250V, 16A VDE 0620-1
model) (Alt) Cable & Appliance 40018857
Factory
Zhongshan
Plug(for all Guzhen Hongli VDE
HL-5B AC250V, 16A VDE 0620-1
model) (Alt) Cable & Appliance 40021267
Factory
Plug(for all Shenzhen Linoya VDE
XYP-02L AC250V, 16A VDE 0620-1
model) (Alt) Electronic Co. Ltd. 40015292

TRF No. IEC60335_2_9M


Page 233 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Shunde Huasheng
Plug(for all VDE
Electrical CT-104 AC250V 16A VDE 0620-1
model) (Alt) 40006002
Industrial Co. Ltd.
Mainland Electric
Plug(for all VDE
Wire & Cable ML-302 AC250V, 16A VDE 0620-1
model) (Alt) 40012805
Co., Ltd
Guangdong
Plug(for all VDE
Rifeng Electrical RF-01 AC250V, 16A VDE 0620-1
model) (Alt) 40026780
Cable Co., Ltd.
Plug(for all Ningbo Qiaopu VDE
D03 AC250V, 16A VDE 0620-1
model) (Alt) Electric Co., Ltd. 40002872
Zhongshan
Plug(for all XESON Electronic VDE
XT-109 AC250V, 16A VDE 0620-1
model) (Alt) Technology 40034487
Co。,Ltd
Zhong shan Yong
Plug(for all VDE
Rui Electric Wire YR-102 AC250V, 16A VDE 0620-1
model) (Alt) 40023358
Ltd
Ningbo Dabu
Plug(for≤for VDE
Electric Appliance DB03 AC250V, 16A VDE 0620-1
all model) (Alt) 40031728
Co.,Ltd
BS Plug(for≤ KDJ Quality
2800W model) Electrical KDJ828 AC 250V, 13A BS 1363 KM 54583
(Alt) Company Ltd.
BS Plug(for≤
Luen Tai (IP’S) 8191, 9691,
2800W model) AC 250V, 13A BS 1363 KM 40790
Electrical Mty 9248, 9518
(Alt)
Chip Kwong
BS Plug(for≤
Electrical
2800W model) CK228 AC 250V, 13A BS 1363 KM 61206
Manufactory
(Alt)
Dongguan China
BS Plug (for≤ SW168,
Scolmore
2800W model) SW268, AC 250V, 13A BS 1363 KM 10807
International Ltd
(Alt) SW368
Guangdong
BS Plug(for≤
KaiHua Electric
2800W model) KH-9917 AC 250V, 13A BS 1363 KM 500333
Appliance Co.,
(Alt)
Ltd.
Plug(for≤ Guangzhou
2800W model) Towell Electrical 8802, 8801 AC 250V, 13A BS 1363 ASTA 805
(Alt) Appliance Co.,Ltd.

TRF No. IEC60335_2_9M


Page 234 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Zhongshan
Plug(for≤
Guzhen Hongli
2800W model) HL-17 AC 250V, 13A BS 1363 ASTA 882
Cable & Appliance
(Alt)
Factory
Shunde Hanli
Plug (for≤
Electrical Wire KEMA
2800W model) HL-882 AC 250V, 13A BS 1363
Production Co., 2110291.01
(Alt)
Ltd.
Plug(for≤
Kaixuanfu Metal &
2800W model) HEC-168 AC 250V, 13A BS 1363 KM 60299
Plastic Co.,LTD
(Alt)
Plug(for≤
ML ELECTRIC MS589:PART1:19
2800W model) 333,363,383 AC 250V 13A PM 073901
SDN .BHD 97
(Alt)
Plug(for≤ PSE
MS589:PART1:19
2800W model) INDUSTRIES(M) 8001N, 8001 AC 250V 13A 016142/08
97
(Alt) SDN. BHD.
Plug(for≤ 145,145N,
SUM SUPPLY & MS589:PART1:19
2800W model) AC 250V 13A 012581/08
ENTERPRISE S145,S145N 97
(Alt)
Plug(for≤
METAL SING MS589:PART1:19
2800W model) HEC-168 AC 250V 13A PM079101
PET.LTD 97
(Alt)
Plug(for≤ CPA HST
Huashin Trading
2800W model) SW198 AC 250V 13A SS145:Part 1:1997 PLR 025347-
(S) Pte. Ltd
(Alt) 00
PSE
Plug (for≤ CPA PSE
ELECTRICAL
2800W model) 8001,8001N AC 250V 13A SS145:Part 1:1997 PLR 080113-
MANUFACTURIN
(Alt) 00
G PTE LTD
Plug(for≤ KONI CPA KON
2800W model) ELECTRONICS(S 828 AC 250V 13A SS145:Part 1:1997 PLR 026180-
(Alt) ) PTE LTD 00
Plug(for≤ TUV SUD
2800W model) MetalSing Pte Ltd HEC-168 AC 250V 13A SS145:Part 1:1997 PSB 100928-
(Alt) 11
Plug(for≤
Foshan Anden
2800W model) 203 AC 250V 13A SS145:Part 1:1997 090656-12
Industry Co.,Ltd
(Alt)
Guangdong Kai
Plug (for≤
Hua Electric CH-11-BS-
2000W model) KH-9953 AC 250V, 10A SEV 1011
Appliance Co., 0379
(Alt)
Ltd.

TRF No. IEC60335_2_9M


Page 235 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Zhongshan
Plug(for≤
Guzhen Hongli CH-05-IK-
2000W model) HL-38 AC 250V, 10A SEV 1011
Cable & Appliance 0235.ZA1.A
(Alt)
Factory
Guangdong
Plug(for≤ Huasheng
2000W model) Electrical CT-110 AC 250V, 10A SEV 1011 11.0908
(Alt) Appliances Co.,
Ltd
Plug(for≤ Kai Hua Electric
Appliance Co., CH-03-IK-
2000W model) KH-9914 AC 250 V, 10 A SEV 1011
Ltd. 0264.ZA1.A
(Alt)
Plug(for≤ Guangdong
2000W model) Huasheng CT-109 AC 250V 10A CEI 23-50 CA02.02637
(Alt) El.App.Co.,Ltd

Zhongshan
Plug(for≤
Guzhen Hongli IMQ
2000W model) HL-14 AC 250V, 10A CEI 23-50-IEd
Cable & Appliance CA02.02729
(Alt)
Factory
Plug (for≤
Kenic Electric Mfg
2000W model) KE-29 AC 250V, 10A CEI 23-16-IEd IMQ EM 352
Co., Ltd.
(Alt)
Plug(for≤
ShengYi Electrical IMQ
2000W model) SY-91 AC 250V, 10A CEI 23-50-IEd
Factory CA02.02985
(Alt)
Plug(for≤
KaiHua Electric IMQ
2000W model) KH-9911 AC 250V, 10A CEI 23-50-IEd
Appliance Co.,Ltd. CA02.01654
(Alt)
Plug(for≤
NEW SQUARE IMQ
2000W model) NS-14 AC 250V, 10A CEI 23-16-IEd
COMPANY LTD CA02.00155
(Alt)
Guangdong Kai
Plug(for≤
Hua Electric
2000W model) KH-9909 AC 250 V, 10 A AS/NZS 3112 18517
Appliance Co.,
(Alt)
Ltd.
Zhongshan
Plug(for≤
Guzhen Hongli
1600W model) HL-11-01 AC 250V, 7.5A AS/NZS 3112 Q061015
Cable & Appliance
(Alt)
Factory
Plug(for≤ Mainland electric
2000W model) wire & cable ML-340 AC 250V, 10A AS/NZS 3112 NSW20617
(Alt) CO,LTD

TRF No. IEC60335_2_9M


Page 236 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Zhongshan
Plug(for≤
XESON Electronic AS/NZS
1600W model) XT-114 AC250V, 7,5A NEW25784
Technology Co., 3112:2004A1
(Alt)
Ltd
Zhongshan
Plug(for≤ XESON Electronic AS/NZS
XT-114 AC250V, 10A NEW25784
2000W model) Technology Co., 3112:2004A1
Ltd
Plug(for≤ Guangdong
2000W model) Rifeng Electrical RF-32 AC 250V 10A AS/NZS 3112 TE20296
(Alt) Cable Co.,Ltd
Ningbo Dabu
Plug(for all SAA130154E
Electric Appliance DB21 250VAC 15A AS/NZS 3112
model) (Alt) A
Co.,Ltd
Zhongshan
Guzhen Hongli H05RR-F 3G1,5mm2 VDE
Power cord VDE 0282-4
Cable & Appliance H05RN-F 3G1,0mm2 40015521
Factory
Zhongshan
Power cord (Alt) 3G1,5mm2
Guzhen Hongli H05RR-F VDE
(0,75mm for ≤
2
VDE 0282-4
Cable & Appliance H05RN-F 3G0,75mm2 40015521
2000W model)
Factory

Power cord (Alt) 3G1,5mm2


Zhong Shan AoLi H05RR-F VDE
(0,75mm2 for ≤ 3G1,0mm2 VDE 0282-4
Electrical Co. Ltd H05RN-F 40040342
2000W model) 3G0,75mm2
Guangdong Kai 3G1,5mm2
Power cord (Alt)
Hua Electric H05RR-F VDE
(0,75mm for ≤
2
3G1,0mm2 VDE 0282-4
Appliance Co., H05RN-F 40015132
2000W model) 3G0,75mm2
Ltd.

Power cord (Alt) 3G1,5mm2


Lucky United H05RR-F VDE
(0,75mm2 for ≤ 3G1,0mm2 VDE 0282-4
Electric Wire H05RN-F 40016378
2000W model) 3G0,75mm2
Guangdong
Power cord (Alt) Huasheng 3G1,5mm2
H05RR-F VDE
(0,75mm2 for ≤ Electrical 3G1,0mm2 VDE 0282-4
H05RN-F 40016788
2000W model) Appliances Co., 3G0,75mm2
Ltd
Dong Guan 3G1,5mm2 VDE
Power cord (Alt)
Recheer Electric H05RR-F 40015173
(0,75mm2 for ≤ 3G1,0mm2 VDE 0282-4
Wire & Cable Co., H05RN-F
2000W model) 3G0,75mm 2
Ltd.

TRF No. IEC60335_2_9M


Page 237 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Power cord (Alt) Guangdong 3G1,5mm2


H05RR-F VDE
(0,75mm2 for ≤ Rifeng Electrical 3G1,0mm2 VDE 0282-4
H05RN-F 40015999
2000W model) Cable Co., Ltd. 3G0,75mm2

Power cord (Alt) Huizhou Mainland 3G1,5mm2


H05RR-F VDE
(0,75mm2 for ≤ Electric Wire & 3G1,0mm2 VDE 0282-4
H05RN-F 40026038
2000W model) Cable Co., Ltd. 3G0,75mm2

Power cord (Alt) 3G1,5mm2


Ningbo Qiaopu H05RR-F VDE
(0,75mm2 for ≤ 3G1,0mm2 VDE 0282-4
Electric Co., Ltd. H05RN-F 40016395
2000W model) 3G0,75mm2

Power cord (Alt) Ningbo Dabu 3G1,5mm2


H05RR-F VDE
(0,75mm2 for ≤ Electric Appliance 3G1,0mm2 VDE 0282-4
H05RN-F 40030691
2000W model) Co.,Ltd 3G0,75mm2
Zhongshan
Power cord (Alt) 3G1,0mm2
Guzhen Hongli H05RR-F
(0,75mm2 for ≤ AN/NZS60245.4 Q060879
Cable & Appliance H05RN-F 3G0,75mm2
2000W model) Factory

Power cord (Alt) 3G1,0mm2


Kai Hua Electric H05RR-F SAA
(0,75mm2 for ≤ AN/NZS60245.4
Appliance Co., Ltd H05RN-F 3G0,75mm2 18304
2000W model)
Power cord (Alt) Shunde Huasheng 3G1,0mm2
H05RR-F
(0,75mm2 for ≤ Electrical AN/NZS60245.4 SAA Q03428
H05RN-F 3G0,75mm2
2000W model) Industrial Co., Ltd.
Power cord (Alt) Ningbo Dabu 3G1,0mm2 SAA130155E
(0,75mm2 for ≤ Electric Appliance 60245IEC 53 AN/NZS60245.4
3G0,75mm2 A
2000W model) Co.,Ltd
Shenzhen Mysun 16-22AWG, IEC/EN 60335-1 Tested With
Internal wire Insulation 3122
Materials Co., Ltd. 300V, 200°C IEC/EN 60335-2-9 Appliance

Internal wire Jiangsu Naiante 3122 16-22AWG, IEC/EN 60335-1 Tested With
(Alt) Cable Co., Ltd. 300V, 200°C IEC/EN 60335-2-9 Appliance
Shenzhen Woer 3122 16-22AWG, IEC/EN 60335-1
Internal wire Tested With
Heat-Shrinkable 300V, 200°C
(Alt) IEC/EN 60335-2-9 Appliance
Materials Co, Ltd.
Zhongshan Sen 3122 16-22AWG, IEC/EN 60335-1
Internal wire Tested With
Te Wire & Cable 300V, 200°C
(Alt) IEC/EN 60335-2-9 Appliance
Co., Ltd

TRF No. IEC60335_2_9M


Page 238 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

FUSHAN 3122 16-22AWG,


SHUNDE 300V, 200°C
Internal wire SPECIAL TYPA IEC/EN 60335-1 Tested With
(Alt) WIRE ROD IEC/EN 60335-2-9 Appliance
ELECTRONICS
CO LTD
WUXI 3122 16-22AWG, IEC/EN 60335-1
Internal wire Tested With
HUACHENG 300V, 200°C
(Alt) IEC/EN 60335-2-9 Appliance
CABLE CO LTD
DONGGUAN EVK 3122 16-22AWG,
Internal wire ELECTRIC IEC/EN 60335-1 Tested With
300V, 200°C
(Alt) TECHNIQUE IEC/EN 60335-2-9 Appliance
CO .LTD
Hong Shun Wire & 10362 16AWG -
Internal wire Cable 20AWG IEC/EN 60335-1 Tested With
(Alt) Fluoroplastics 250 C, 600 V IEC/EN 60335-2-9 Appliance
Factory
Shenzhen Mysun 16-20AWG, IEC/EN 60335-1
Internal wire Tested With
Insulation 10362
(Alt) 600V, 250°C IEC/EN 60335-2-9 Appliance
Materials Co., Ltd.
NIZING 16-20AWG, IEC/EN 60335-1
Internal wire Tested With
ELECTRIC CO 10362
(Alt) 600V, 250°C IEC/EN 60335-2-9 Appliance
LTD
Zhongshan AC 250V, 16A,
Haotong Electrical HT-168 T250, 5E4, IEN 60730-1 CQCSCL011
Thermostat Appliances Co., Tf125°C±5°C IEN 60730-2-9 6-0178-B
Ltd.
Zhongshan City 250VAC, 10A,
Adjustable
Xingxin 100000 Cycles, EN 60730-1 TUV
Thermostat KST398B
Thermostat Co., T280, EN 60730-2-9 R50142283
for(Alt)
Ltd. Tf125°C±5°C
250VAC, 10A,
Adjustable Foshan Gaoming 40000 Cycles, EN 60730-1 VDE
Thermostat Xite Electrical Co., KST201B
T240, EN 60730-2-9 40012302
for(Alt) Ltd.
Tf125°C±5°C
250VAC,
Adjustable Shenzhen Forever WK-03 10A/16A,
EN 60730-1 TUV
Thermostat Great Technology 100000 cycles,
WK-03A EN 60730-2-9 R50139229
for(Alt) Co., Ltd. T250,
Tf125°C±5°C

TRF No. IEC60335_2_9M


Page 239 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Foshan KST305-1 AC 250V, EN 60730-1 TUV SUD B1


JinAoXiang KST305-2 10/15/16A EN 60730-2-9 16 03 92563
Adjustable
Electrical T260, 1E5, 003
Thermostat
Appliance Tf125°C±5°C
for(Alt)
Technology
Co.,Ltd
Adjustable Foshan Nuo Kai KST201-2A, AC 250V, 16A, EN 60730-1 TUV R
Thermostat Electrical KST201-1D T250, 3E4, EN 60730-2-9 50263858
for(Alt) Appliance Co., Ltd Tf125°C±5°C
Adjustable ZhongShan City KST-968, AC 250V, 16A, EN 60730-1 TUV R
Thermostat Dickson Electric KSTR-968 T250, 10E4, EN 60730-2-9 50195805
for(Alt) Co., Ltd. Tf125°C±5°C
Foshan Shunde KSD301-Cy AC 250V, 10A EN 60730-1 TUV R
Xingtan Zhongbao T270 270℃ EN 60730-2-9 50114187
Thermostat 10000cyces
Thermostat Co.,
Ltd.
Hua Li Lai
AC250V,
Electrical TUV
Select switch FZ31-3H 10(1.5)A, EN 61058-1
Equipment Co., R50145221
T125/55, 1E4
Ltd.
Select Nova Electronics AC250V, 10A, TUV
KXZ-G EN 61058-1
switch(Alt) Co., Ltd. T160, 1E4 R50047760
Hua Li Lai
Select 250VAC, 16A, TUV
Electrical FZ31-9 EN 61058-1
switch(Alt) T125/55, 1E4 R50033687
Equiment Co., Ltd
Select Cixi Kangbo 250VAC, 16A, TUV
RS-16 EN 61058-1
switch(Alt) Electrical Co., Ltd. T125, 1E4 R50195980
Dongguan Naijiaer XK1-211, XK1- AC 250V, 16A, EN 61058-1 TUV SUD B
Select
Electric Hardware 222 10E3, T125 15 07 92413
switch(Alt)
Co.,Ltd 001
Zhejiang hongxing
Select Electronic 250VAC, 16A, TUV
KX44 EN 61058-1
switch(Alt) Appliances Co., T125, 10E3 50201139
ltdl
Hangzhou
guanzuan 250VAC, 16A, EN 60730-1
Timer DKJ/1 series VDE 126656
Electrical 1E4, T125 EN 60730-2-7
Appliances Co., ltd
Hangzhou Time-
250VAC,16A, EN 60730-1 TUV
Timer (Alt) control Si-Tech DKJ-Y
1E4, T125 EN 60730-2-7 R50166731
Co.,Ltd

TRF No. IEC60335_2_9M


Page 240 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Jiangsu Shalong
Mechanical & SL-60C
250VAC,16A, EN 60730-1 TUV
Timer (Alt) Electrical SL-60C1
1E4, T120 EN 60730-2-7 R50024942
Technology Co., SL-120
Ltd.
Hangzhou
Franden Electrical 250VAC, 16A, EN 60730-1 VDE
Timer (Alt) DKJ-Y
Manufacture Co. 1E4, T125 EN 60730-2-7 40006336
Ltd.
Zhejiang
250VAC, 16A, EN 60730-1 VDE
Timer (Alt) Shammah DKJ-Y-*
1E4, T125 EN 60730-2-7 40034918
Electronics Co.,Ltd
Zhongshan 220-240VAC,
Synchronous Haotong Electrical 50/60Hz, 4W, IEC/EN 60335-1 Tested With
HTY50-H
motor Appliances Co., Class 180 IEC/EN 60335-2-9 Appliance
Ltd. (Class H)
220-240VAC,
Synchronous Cixi Kangbo TYC50A- 50/60Hz, 4W, VDE
EN 60335-1
motor (Alt) Electrical Co., Ltd. 2118-H Class 180 40007003
(Class H)
Zhaoqing Longtou AC220-240V,
Synchronous Electric 50/60Hz, 4W,
TY-50AF EN 60335-1 VDE 134544
motor (Alt) Technology Co., Class 155
Ltd. (Class F)
Zhongshan
AC 220-240V, IEC/EN 60335-1
Haotong Electrical Tested With
Fan motor HT48-07 7W, Class 180
Appliances Co., IEC/EN 60335-2-9 Appliance
(Class H)
Ltd.
Foshan Regal R61-230 AC 220-240V, EN 60335-1 VDE
Motor Co. Ltd. R61-230H 50/60Hz, 12W, EN 60335-2-9 40011982
Class 180
(Class H)
Fan motor (Alt)
AC 220-240V,
50/60Hz, 30W,
Class 180
(Class H)
AC 220-240V,
Foshan Regal VDE
Fan motor (Alt) R48-230 7W, Class 180 EN 60335-1
Motor Co., Ltd. 40011982
(Class H)
Yuyao Changhong AC250V, 2A, VDE
Lampholder E14-A EN 60238
Electric Factory T170 40004460

Lampholder Yuyao Changhong AC250V, 2A, GB17935 CQC0900402


E14-C3
(Alt) Electric Factory T240 EN 60238 9432

TRF No. IEC60335_2_9M


Page 241 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Yueqing TUV SUD


Lampholder AC250V, 2A,
Xianglong Electric E14-A EN 60238 B 11 08
(Alt) T170
Co., Ltd. 77756 004
Lampholder Xiamen Walklong X555 AC250V, 2A EN 60238 TUV*/R
(Alt) Electiical Co.,Ltd T170 50090013

50/60Hz 110-
120V AC 200W
220W 180W
275W 225W
325W 320W
280W 345W
370W 350W
guang dong 375W 400W CQC1000205
Province gao yao 425W 450W IEC/EN 60335-1 3880(Tested
Heating element City jin tian five H 475W 500W
metals products IEC/EN 60335-2-9 With
550W 600W Appliance)
CO.,Ltd 700W
50/60Hz 220-
240VAC 400W
600W 900W
1000W 1100W
1200W 1300W
1400W
Zhongshan
Plastic material Haotong Electrical IEC/EN 60335-1 Tested With
PC, --
for lamp cover Appliances Co., IEC/EN 60335-2-9 Appliance
Ltd.
Dong Guan CQC1313408
Plastic material IEC/EN 60335-1
Chuang Lian 6991(Tested
for lamp cover PC --
Electrical IEC/EN 60335-2-9 With
(Alt)
Appliance Co.Ltd Appliance)
Plastic material
Zhongshan
for Control IEC/EN 60335-1
Haotong Electrical Tested With
Panel and PBT, ---
Appliances Co., IEC/EN 60335-2-9 Appliance
support base,
Ltd.
knobs
Plastic material GUANGDONG
CQC1513412
for Control SHUNDE IEC/EN 60335-1 8285(Tested
Panel and SHUNYAN NEW PBT, ---
support base, MATERAL CO., IEC/EN 60335-2-9 With
Appliance)
knobs( Alt) LTD
Plastic material
NanTong CQC1513413
for Control IEC/EN 60335-1
ZhongLan 7188(Tested
Panel and PBT, ---
Engineering IEC/EN 60335-2-9 With
support base,
Plastics Co,Ltd Appliance)
knobs( Alt)

TRF No. IEC60335_2_9M


Page 242 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Closed circuit HEAVY POWER CE1, CE2, IEC/EN 60335-1 Tested With
105ºC, 300V
terminal CO LTD CE5 IEC/EN 60335-2-9 Appliance
SHENZHEN
WOER HEAT- IEC/EN 60335-1
Heat shrinkable Tested with
SHRINKABLE RSFR-H 600 V, 125°C
tube IEC/EN 60335-2-9 appliance
MATERIAL CO.,
LTD.
GUANGZHOU
Heat shrinkable IEC/EN 60335-1 Tested with
KAIHENG NEW K-102 600 V, 125°C
tube(Alt) IEC/EN 60335-2-9 appliance
MATERLAL .LTD
1) An asterisk indicates a mark which assures the agreed level of surveillance

28.1 TABLE: Threaded part torque test P


Threaded part identification Diameter of thread Column number Applied torque (Nm)
(mm) (I, II, or III)
Fixing screws of enclosure 3.8 II 1.2
Earthing screw 3.8 II 1.2
Supplementar information:

29.1 TABLE: Clearances P


Overvoltage category.......................... ...................... : II 
Type of insulation:
Rated impulse Min. cl (mm) Basic Supplementary Reinforced Functional Verdict / Remark
voltage (V): (mm) (mm) (mm) (mm)
330 0,2* / 0,5 / 0,8**
500 0,2* / 0,5 / 0,8**
800 0,2* / 0,5 / 0,8**
1 500 0,5 / 0,8** / 1,0***
2 500 1,5 / 2,0*** >3,0 >3,0 >3,0 P
4 000 3,0 / 3,5*** >5,0 P
6 000 5,5 / 6,0*** P
8 000 8,0 / 8,5***
10 000 11,0 / 11,5***

TRF No. IEC60335_2_9M


Page 243 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

Supplementary information:
*) For tracks on printed circuit boards if pollution degree 1 and 2
**) For pollution degree 3
***) If the construction is affected by wear, distortion, movement of the parts or during assembly

29.2 TABLE: Creepage distances, basic, supplementary and reinforced insulation


Working voltage Creepage distance
(V) (mm)
Pollution degree
1 2 3 Type of insulation
Material group Material group
I II IIIa/IIIb I II IIIa/IIIb*) B**) S**) R**) Verdict
50 0,18 0,6 0,85 1,2 1,5 1,7 1,9  
50 0,18 0,6 0,85 1,2 1,5 1,7 1,9  
50 0,36 1,2 1,7 2,4 3,0 3,4 3,8  
125 0,28 0,75 1,05 1,5 1,9 2,1 2,4  
125 0,28 0,75 1,05 1,5 1,9 2,1 2,4  
125 0,56 1,5 2,1 3,0 3,8 4,2 4,8  
250 0,56 1,25 1,8 2,5 3,2 3,6 4,0 >  
4,0
250 0,56 1,25 1,8 2,5 3,2 3,6 4,0  >  P
4,0
250 1,12 2,5 3,6 5,0 6,4 7,2 8,0   > P
8,0
400 1,0 2,0 2,8 4,0 5,0 5,6 6,3  
400 1,0 2,0 2,8 4,0 5,0 5,6 6,3  
400 2,0 4,0 5,6 8,0 10,0 11,2 12,6  
500 1,3 2,5 3,6 5,0 6,3 7,1 8,0  
500 1,3 2,5 3,6 5,0 6,3 7,1 8,0  
500 2,6 5,0 7,2 10,0 12,6 14,2 16,0  
630 and 800 1,8 3,2 4,5 6,3 8,0 9,0 10,0  
630 and 800 1,8 3,2 4,5 6,3 8,0 9,0 10,0  
630 and 800 3,6 6,4 9,0 12,6 16,0 18,0 20,0  
800 and 1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5  
800 and 1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5  

TRF No. IEC60335_2_9M


Page 244 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

800 and 1000 4,8 8,0 11,2 16,0 20,0 22,0 25,0   P
1000 and 1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0  
1000 and 1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0  
1000 and 1250 6,4 10,0 14,2 20,0 25,0 28,0 32,0  
1250 and 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0  
1250 and 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0  
1250 and 1600 8,4 12,6 18,0 25,0 32,0 36,0 40,0  
1600 and 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0  
1600 and 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0  
1600 and 2000 11,2 16,0 22,0 32,0 40,0 44,0 50,0  
2000 and 2500 7,5 10,0 14,0 20,0 25,0 28,0 32,0  
2000 and 2500 7,5 10,0 14,0 20,0 25,0 28,0 32,0  
2000 and 2500 15,0 20,0 28,0 40,0 50,0 56,0 64,0  
2500 and 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0  
2500 and 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0  
>2500 and 3200 20,0 25,0 36,0 50,0 64,0 72,0 80,0  
3200 and 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0  
3200 and 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0  
3200 and 4000 25,0 32,0 44,0 64,0 80,0 90,0 100,0  
4000 and 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0  
4000 and 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0  
4000 and 5000 32,0 40,0 56,0 80,0 100,0 112,0 126,0  
5000 and 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0  
5000 and 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0  
5000 and 6300 40,0 50,0 72,0 100,0 126,0 142,0 160,0  
6300 and 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0  
6300 and 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0  
6300 and 8000 50,0 64,0 90,0 126,0 160,0 180,0 200,0  
8000 and 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0  
8000 and 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0  
8000 and 10000 64,0 80,0 112,0 160,0 200,0 220,0 250,0  
10000 and 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0  

TRF No. IEC60335_2_9M


Page 245 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

10000 and 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0  
10000 and 12500 80,0 100,0 142,0 200,0 250,0 280,0 320,0  
Supplementary information:
*) Material group IIIb is allowed if the working voltage does not exceed 50 V
**) B = Basic insulation, S = Supplementary insulation, R = Reinforced insulation

29.2 TABLE: Creepage distances, functional insulation P


Working voltage Creepage distance
(V) (mm)
Pollution degree
1 2 3
Material group Material group
I II IIIa/IIIb I II IIIa/IIIb*) Verdict / Remark
10 0,08 0,4 0,4 0,4 1,0 1,0 1,0
50 0,16 0,56 0,8 1,0 1,4 1,6 1,8
125 0,25 0,71 1,0 1,4 1,8 2,0 2,2
250 0,42 1,0 1,4 2,0 2,5 2,8 3,2 >4,0/P
400 0,75 1,6 2,2 3,2 4,0 4,5 5,0
500 1,0 2,0 2,8 4,0 5,0 5,6 6,3
630 and 800 1,8 3,2 4,5 6,3 8,0 9,0 10,0
800 and 1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5
1000 and 1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0
1250 and 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0
1600 and 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0
2000 and 2500 7,5 10,0 14,0 20,0 25,0 28,0 32,0
2500 and 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0
3200 and 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0
4000 and 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0
5000 and 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0
6300 and 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0
8000 and 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0
10000 and 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0
Supplementary information:
*) Material group IIIb is allowed if the working voltage does not exceed 50 V

TRF No. IEC60335_2_9M


Page 246 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

30 TABLE: Resistance to heat and fire


Object/ Manufacturer Type/ Ball pressure test Glow wire test Glow-wire Glow- Needle- Verdict
part No. / model °C (GWT) flammability index wire flame test
trademark °C (GWFI) ignition (NFT)
°C temp.
(GWIT)
°C
75 125 cl. 11 cl. 19 550 650 750 850 550 650 750 850 675 775
+40 +25
te ti te ti

Zhongshan
Plastic Haotong
N/ N/ N/ N/
material for Electrical PC, 1,0 N/A N/A N/A P N/A N/A N/A N/A N/A N/A N/A N/A P
A A A A
lamp cover Appliances
Co., Ltd.
Plastic
Zhongshan
material for
Haotong
Control N/ N/ N/ N/
Electrical PBT, 1.0 N/A N/A N/A P N/A N/A N/A N/A N/A N/A N/A N/A P
Panel and A A A A
Appliances
support
Co., Ltd.
base, knobs
Closed HEAVY CE1,
N/ N/
circuit POWER CO CE2, N/A N/A N/A N/A N/A 0 0 P N/A N/A N/A N/A N/A N/A N/A P
A A
terminal LTD CE5

Heat SHENZHEN RSFR- N/ N/


N/A N/A N/A N/A N/A 0 0 P N/A N/A N/A N/A N/A N/A N/A P
shrinkable WOER H A A

TRF No. IEC60335_2_9M


Page 247 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Clause Requirement + Test Result - Remark Verdict

tube HEAT-
SHRINKABL
E MATERIAL
CO., LTD.
GUANGZHO
Heat U KAIHENG
N/ N/
shrinkable NEW K-102 N/A N/A N/A N/A N/A 0 0 P N/A N/A N/A N/A N/A N/A N/A P
A A
tube(Alt) MATERLAL .
LTD
Supplementary information:
1) Parts of material classified at least HB40 or if relevant HBF
2) Parts of material classified as V- 0 or V- 1
3)
Flame persisting longer than 2 s (= te – ti) need only be reported for unattended appliances
4)
Surrounding parts subjected to the needle-flame test of annex E
5)
Base material classified as V- 0 or if relevant VTM-0
6)
The GWIT pre-selection option, the 850 °C GWFI pre-selection option, and the 850 °C GWT are not applicable for attended appliances

TRF No. IEC60335_2_9M


Page 248 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

Photos for model HK-P55RCL,HK-P55CL

HK-P55RCL

TRF No. IEC60335_2_9M


Page 249 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

TRF No. IEC60335_2_9M


Page 250 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

TRF No. IEC60335_2_9M


Page 251 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

TRF No. IEC60335_2_9M


Page 252 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

TRF No. IEC60335_2_9M


Page 253 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

TRF No. IEC60335_2_9M


Page 254 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

TRF No. IEC60335_2_9M


Page 255 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

TRF No. IEC60335_2_9M


Page 256 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

Coverage model photos

HK-P55,HK-P55R,HK-P55C,HK-P55L,HK-P55RL,HK-P55CL

HK-12002,HK-12002R,HK-12002C,HK-12002L,HK-12002RL,HK-12002CL

TRF No. IEC60335_2_9M


Page 257 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-12002RC,HK-12002RCL

HK-120,HK-120R,HK-120C,HK-120L,HK-120RL,HK-120CL,

TRF No. IEC60335_2_9M


Page 258 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-120RC,HK-120RCL

HK-10002,HK-10002R,HK-10002C,HK-10002L,HK-10002RL,HK-10002CL,

TRF No. IEC60335_2_9M


Page 259 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-10002RC,HK-10002RCL

HK-100,HK-100R,HK-100C,HK-100L,HK-100RL,HK-100CL,

TRF No. IEC60335_2_9M


Page 260 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-100RC,HK-100RCL

HK-P75,HK-P75R,HK-P75C,HK-P75L,HK-P75RL,HK-P75CL,

TRF No. IEC60335_2_9M


Page 261 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-P75RC,HK-P75RCL;

HK-75,HK-75R,HK-75C,HK-75L,HK-75RL,HK-75CL,

TRF No. IEC60335_2_9M


Page 262 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-75RC,HK-75RCL

HK-95,HK-95R,HK-95C,HK-95L,HK-95RL,HK-95CL,

TRF No. IEC60335_2_9M


Page 263 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-95RC,HK-95RCL

HK-85,HK-85R,HK-85C,HK-85L,HK-85RL,HK-85CL,

TRF No. IEC60335_2_9M


Page 264 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-85RC,HK-85RCL

HK-8002,HK-8002R,HK-8002C,HK-8002L,HK-8002RL,HK-8002CL,

TRF No. IEC60335_2_9M


Page 265 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-8002RC,HK-8002RCL

HK-8001,HK-8001R,HK-8001C,HK-8001L,HK-8001RL,HK-8001CL,

TRF No. IEC60335_2_9M


Page 266 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-8001RC,HK-8001RCL

HK-80,HK-80R,HK-80C,HK-80L,HK-80RL,HK-80CL,

TRF No. IEC60335_2_9M


Page 267 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-80RC,HK-80RCL;

HK-7002,HK-7002R,HK-7002C,HK-7002L,HK-7002RL,HK-7002CL,

TRF No. IEC60335_2_9M


Page 268 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-7002RC,HK-7002RCL

HK-7001,HK-7001R,HK-7001C,HK-7001L,HK-7001RL,HK-7001CL,

TRF No. IEC60335_2_9M


Page 269 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-7001RC,HK-7001RCL

HK-70,HK-70R,HK-70C,HK-70L,HK-70RL,HK-70CL,

TRF No. IEC60335_2_9M


Page 270 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-70RC,HK-70RCL

HK-7501,HK-7501R,HK-7501C,HK-7501L,HK-7501RL,HK-7501CL,

TRF No. IEC60335_2_9M


Page 271 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-7501RC,HK-7501RCL

HK-6008,HK-6008R,HK-6008C,HK-6008L,HK-6008RL,HK-6008CL,

TRF No. IEC60335_2_9M


Page 272 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-6008RC,HK-6008RCL

HK-6006,HK-6006R,HK-6006C,HK-6006L,HK-6006RL,HK-6006CL,

TRF No. IEC60335_2_9M


Page 273 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-6006RC,HK-6006RCL

HK-65C, HK-65CL , HK-65RC , HK-65RCL

TRF No. IEC60335_2_9M


Page 274 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-6005,HK-6005R,HK-6005C,HK-6005L,HK-6005RL,HK-6005CL,

HK-6005RC,HK-6005RCL

TRF No. IEC60335_2_9M


Page 275 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-6004,HK-6004R,HK-6004C,HK-6004L,HK-6004RL,HK-6004CL,

HK-6004RC,HK-6004RCL

TRF No. IEC60335_2_9M


Page 276 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-6003,HK-6003R,HK-6003C,HK-6003L,HK-6003RL,HK-6003CL,

HK-6003RC,HK-6003RCL

TRF No. IEC60335_2_9M


Page 277 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-6002,HK-6002R,HK-6002C,HK-6002L,HK-6002RL,HK-6002CL,

HK-6002RC,HK-6002RCL

TRF No. IEC60335_2_9M


Page 278 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-60,HK-60R,HK-60C,HK-60L,HK-60RL,HK-60CL,

HK-60RC,HK-60RCL

TRF No. IEC60335_2_9M


Page 279 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-6009,HK-6009R,HK-6009C,HK-6009L,HK-6009RL,HK-6009CL,

HK-6009RC,HK-6009RCL

TRF No. IEC60335_2_9M


Page 280 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-56,HK-56R,HK-56C,HK-56L,HK-56RL,HK-56CL,

HK-56RC,HK-56RCL

TRF No. IEC60335_2_9M


Page 281 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-55,HK-55R,HK-55C,HK-55L,HK-55RL,HK-55CL,

HK-55RC,HK-55RCL

TRF No. IEC60335_2_9M


Page 282 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-5501,HK-5501R,HK-5501C,HK-5501L,HK-5501RL,HK-5501CL,

HK-5501RC,HK-5501RCL

TRF No. IEC60335_2_9M


Page 283 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-53,HK-53R,HK-53C,HK-53L,HK-53RL,HK-53CL,

HK-53RC,HK-53RCL

TRF No. IEC60335_2_9M


Page 284 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-5202,HK-5202R,HK-5202C,HK-5202L,HK-5202RL,HK-5202CL,

HK-5202RC,HK-5202RCL

TRF No. IEC60335_2_9M


Page 285 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-P50,HK-P50R,HK-P50C,HK-P50L,HK-P50RL,HK-P50CL, HK-P50RC,HK-P50RCL

HK-5002,HK-5002R,HK-5002C,HK-5002L,HK-5002RL,HK-5002CL,

TRF No. IEC60335_2_9M


Page 286 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-5002RC,HK-5002RCL

HK-5001,HK-5001R,HK-5001C,HK-5001L,HK-5001RL,HK-5001CL,

TRF No. IEC60335_2_9M


Page 287 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-5001RC,HK-5001RCL

HK-50B,HK-50BR,HK-50BC,HK-50BL,HK-50BRL,HK-50BCL,

TRF No. IEC60335_2_9M


Page 288 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-50BRC,HK-50BRCL

HK-5004,HK-5004R,HK-5004C,HK-5004L,HK-5004RL,HK-5004CL,

TRF No. IEC60335_2_9M


Page 289 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-5004RC,HK-5004RCL

HK-5005,HK-5005R,HK-5005C,HK-5005L,HK-5005RL,HK-5005CL,

TRF No. IEC60335_2_9M


Page 290 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-5005RC,HK-5005RCL

HK-5006,HK-5006R,HK-5006C,HK-5006L,HK-5006RL,HK-5006CL,

TRF No. IEC60335_2_9M


Page 291 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-5006RC,HK-5006RCL

HK-5008,HK-5008R,HK-5008C,HK-5008L,HK-5008RL,HK-5008CL,

TRF No. IEC60335_2_9M


Page 292 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-5008RC,HK-5008RCL

HK-5007,HK-5007R,HK-5007C,HK-5007L,HK-5007RL,HK-5007CL,

TRF No. IEC60335_2_9M


Page 293 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-5007RC,HK-5007RCL

HK-4802,HK-4802R,HK-4802C,HK-4802L,HK-4802RL,HK-4802CL,HK-4802RC,HK-
4802RCL

TRF No. IEC60335_2_9M


Page 294 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-4803,HK-4803R,HK-4803C,HK-4803L,HK-4803RL,HK-4803CL,

HK-4803RC,HK-4803RCL

TRF No. IEC60335_2_9M


Page 295 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-46,HK-46R,HK-46C,HK-46L,HK-46RL,HK-46CL,

HK-46RC,HK-46RCL

TRF No. IEC60335_2_9M


Page 296 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-4501,HK-4501R,HK-4501C,HK-4501L,HK-4501RL,HK-4501CL,

HK-4501RC,HK-4501RCL

TRF No. IEC60335_2_9M


Page 297 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-45,HK-45R,HK-45C,HK-45L,HK-45RL,HK-45CL,

HK-45RC,HK-45RCL

TRF No. IEC60335_2_9M


Page 298 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-4504,HK-4504R,HK-4504C,HK-4504L,HK-4504RL,HK-4504CL,

HK-4504RC,HK-4504RCL

TRF No. IEC60335_2_9M


Page 299 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-4505,HK-4505R,HK-4505C,HK-4505L,HK-4505RL,HK-4505CL,

HK-4505RC,HK-4505RCL

TRF No. IEC60335_2_9M


Page 300 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-B44,HK-B44R,HK-B44C,HK-B44L,HK-B44RL,HK-B44CL, HK-B44RC,HK-B44RCL

HK-43,HK-43R,HK-43C,HK-43L,HK-43RL,HK-43CL,

HK-43RC,HK-43RCL

TRF No. IEC60335_2_9M


Page 301 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-4303,HK-4303R,HK-4303C,HK-4303L,HK-4303RL,HK-4303CL,

TRF No. IEC60335_2_9M


Page 302 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-4303RC,HK-4303RCL

HK-4302,HK-4302R,HK-4302C,HK-4302L,HK-4302RL,HK-4302CL, HK-4302RC,HK-
4302RCL

TRF No. IEC60335_2_9M


Page 303 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-4305,HK-4305R,HK-4305C,HK-4305L,HK-4305RL,HK-4305CL,

HK-4305RC,HK-4305RCL

TRF No. IEC60335_2_9M


Page 304 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-4307,HK-4307R,HK-4307C,HK-4307L,HK-4307RL,HK-4307CL,

HK-4307RC,HK-4307RCL

TRF No. IEC60335_2_9M


Page 305 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-42,HK-42R,HK-42C,HK-42L,HK-42RL,HK-42CL,

HK-42RC,HK-42RCL

TRF No. IEC60335_2_9M


Page 306 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-4202,HK-4202R,HK-4202C,HK-4202L,HK-4202RL,HK-4202CL,

HK-4202RC,HK-4202RCL

TRF No. IEC60335_2_9M


Page 307 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-4203,HK-4203R,HK-4203C,HK-4203L,HK-4203RL,HK-4203CL,

HK-4203RC,HK-4203RCL

TRF No. IEC60335_2_9M


Page 308 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-4204,HK-4204R,HK-4204C,HK-4204L,HK-4204RL,HK-4204CL,

HK-4204RC,HK-4204RCL

TRF No. IEC60335_2_9M


Page 309 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-40,HK-40R,HK-40C,HK-40L,HK-40RL,HK-40CL,

HK-40RC,HK-40RCL

TRF No. IEC60335_2_9M


Page 310 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-4001,HK-4001R,HK-4001C,HK-4001L,HK-4001RL,HK-4001CL,

HK-4001RC,HK-4001RCL

TRF No. IEC60335_2_9M


Page 311 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-4002,HK-4002R,HK-4002C,HK-4002L,HK-4002RL,HK-4002CL,

HK-4002RC,HK-4002RCL

TRF No. IEC60335_2_9M


Page 312 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-4003,HK-4003R,HK-4003C,HK-4003L,HK-4003RL,HK-4003CL,

HK-4003RC,HK-4003RCL

TRF No. IEC60335_2_9M


Page 313 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-3803,HK-3803R,HK-3803C,HK-3803L,HK-3803RL,HK-3803CL,

HK-3803RC,HK-3803RCL

TRF No. IEC60335_2_9M


Page 314 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-3807,HK-3807R,HK-3807C,HK-3807L,HK-3807RL,HK-3807CL,

HK-3807RC,HK-3807RCL

TRF No. IEC60335_2_9M


Page 315 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-3804,HK-3804R,HK-3804C,HK-3804L,HK-3804RL,HK-3804CL,

HK-3804RC,HK-3804RCL

TRF No. IEC60335_2_9M


Page 316 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-38,HK-38R,HK-38C,HK-38L,HK-38RL,HK-38CL,

HK-38RC,HK-38RCL

TRF No. IEC60335_2_9M


Page 317 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-3806,HK-3806R,HK-3806C,HK-3806L,HK-3806RL,HK-3806CL,

HK-3806RC,HK-3806RCL

TRF No. IEC60335_2_9M


Page 318 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-36,HK-36R,HK-36C,HK-36L,HK-36RL,HK-36CL,

HK-36RC,HK-36RCL

TRF No. IEC60335_2_9M


Page 319 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-3602,HK-3602R,HK-3602C,HK-3602L,HK-3602RL,HK-3602CL,HK-3602RC,HK-
3602RCL

HK-3603,HK-3603R,HK-3603C,HK-3603L,HK-3603RL,HK-3603CL,

TRF No. IEC60335_2_9M


Page 320 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-3603RC,HK-3603RCL

HK-35,HK-35R,HK-35C,HK-35L,HK-35RL,HK-35CL,

TRF No. IEC60335_2_9M


Page 321 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-35RC,HK-35RCL

HK-3504,HK-3504R,HK-3504C,HK-3504L,HK-3504RL,HK-3504CL,

TRF No. IEC60335_2_9M


Page 322 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-3504RC,HK-3504RCL

HK-3505,HK-3505R,HK-3505C,HK-3505L,HK-3505RL,HK-3505CL,

TRF No. IEC60335_2_9M


Page 323 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-3505RC,HK-3505RCL

HK-3506,HK-3506R,HK-3506C,HK-3506L,HK-3506RL,HK-3506CL,

TRF No. IEC60335_2_9M


Page 324 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-3506RC,HK-3506RCL

HK-3507,HK-3507R,HK-3507C,HK-3507L,HK-3507RL,HK-3507CL,

TRF No. IEC60335_2_9M


Page 325 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-3507RC,HK-3507RCL

HK-3502,HK-3502R,HK-3502C,HK-3502L,HK-3502RL,HK-3502CL,

TRF No. IEC60335_2_9M


Page 326 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-3502RC,HK-3502RCL

HK-P34,HK-P34R,HK-P34C,HK-P34L,HK-P34RL,HK-P34CL,

TRF No. IEC60335_2_9M


Page 327 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-P34RC,HK-P34RCL

HK-3403,HK-3403R,HK-3403C,HK-3403L,HK-3403RL,HK-3403CL,

TRF No. IEC60335_2_9M


Page 328 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-3403RC,HK-3403RCL

HK-34,HK-34R,HK-34C,HK-34L,HK-34RL,HK-34CL,

TRF No. IEC60335_2_9M


Page 329 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-34RC,HK-34RCL

HK-3404,HK-3404R,HK-3404C,HK-3404L,HK-3404RL,HK-3404CL,

TRF No. IEC60335_2_9M


Page 330 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-3404RC,HK-3404RCL

HK-3406,HK-3406R,HK-3406C,HK-3406L,HK-3406RL,HK-3406CL,

TRF No. IEC60335_2_9M


Page 331 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-3406RC,HK-3406RCL

HK-33B,HK-33BR,HK-33BC,HK-33BL,HK-33BRL,HK-33BCL,

TRF No. IEC60335_2_9M


Page 332 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-33BRC,HK-33BRCL

HK-3301,HK-3301R,HK-3301C,HK-3301L,HK-3301RL,HK-3301CL,

TRF No. IEC60335_2_9M


Page 333 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-3301RC,HK-3301RCL

HK-32,HK-32R,HK-32C,HK-32L,HK-32RL,HK-32CL,

TRF No. IEC60335_2_9M


Page 334 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-32RC,HK-32RCL

HK-3201,HK-3201R,HK-3201C,HK-3201L,HK-3201RL,HK-3201CL,

TRF No. IEC60335_2_9M


Page 335 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-3201RC,HK-3201RCL

HK-3202,HK-3202R,HK-3202C,HK-3202L,HK-3202RL,HK-3202CL,HK-3202RC,HK-
3202RCL

TRF No. IEC60335_2_9M


Page 336 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-30,HK-30R,HK-30C,HK-30L,HK-30RL,HK-30CL,

HK-30RC,HK-30RCL

TRF No. IEC60335_2_9M


Page 337 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-P30,HK-P30R,HK-P30C,HK-P30L,HK-P30RL,HK-P30CL, HK-P30RC,HK-P30RCL

HK-3001,HK-3001R,HK-3001C,HK-3001L,HK-3001RL,HK-3001CL,

HK-3001RC,HK-3001RCL

TRF No. IEC60335_2_9M


Page 338 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2808,HK-2808R,HK-2808C,HK-2808L,HK-2808RL,HK-2808CL,

TRF No. IEC60335_2_9M


Page 339 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2808RC,HK-2808RCL

HK-28,HK-28R,HK-28C,HK-28L,HK-28RL,HK-28CL,

TRF No. IEC60335_2_9M


Page 340 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-28RC,HK-28RCL

HK-2805,HK-2805R,HK-2805C,HK-2805L,HK-2805RL,HK-2805CL,HK-2805RC,HK-
2805RCL

TRF No. IEC60335_2_9M


Page 341 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2806,HK-2806R,HK-2806C,HK-2806L,HK-2806RL,HK-2806CL,HK-2806RC,HK-
2806RCL

HK-2801,HK-2801R,HK-2801C,HK-2801L,HK-2801RL,HK-2801CL,

TRF No. IEC60335_2_9M


Page 342 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2801RC,HK-2801RCL

HK-2802,HK-2802R,HK-2802C,HK-2802L,HK-2802RL,HK-2802CL,HK-2802RC,HK-
2802RCL

TRF No. IEC60335_2_9M


Page 343 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2803,HK-2803R,HK-2803C,HK-2803L,HK-2803RL,HK-2803CL,

HK-2803RC,HK-2803RCL

TRF No. IEC60335_2_9M


Page 344 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2804,HK-2804R,HK-2804C,HK-2804L,HK-2804RL,HK-2804CL,

HK-2804RC,HK-2804RCL

TRF No. IEC60335_2_9M


Page 345 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2809,HK-2809R,HK-2809C,HK-2809L,HK-2809RL,HK-2809CL,

HK-2809RC,HK-2809RCL

TRF No. IEC60335_2_9M


Page 346 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-P28,HK-P28R,HK-P28C,HK-P28L,HK-P28RL,HK-P28CL,HK-P28RC,HK-P28RCL

HK-26,HK-26R,HK-26C,HK-26L,HK-26RL,HK-26CL,HK-26RC,HK-26RCL

TRF No. IEC60335_2_9M


Page 347 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2602,HK-2602R,HK-2602C,HK-2602L,HK-2602RL,HK-2602CL,HK-2602RC,HK-
2602RCL

HK-2606,HK-2606R,HK-2606C,HK-2606L,HK-2606RL,HK-2606CL,

TRF No. IEC60335_2_9M


Page 348 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2606RC,HK-2606RCL

HK-2603,HK-2603R,HK-2603C,HK-2603L,HK-2603RL,HK-2603CL,HK-2603RC,HK-
2603RCL

TRF No. IEC60335_2_9M


Page 349 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2605,HK-2605R,HK-2605C,HK-2605L,HK-2605RL,HK-2605CL,

HK-2605RC,HK-2605RCL

TRF No. IEC60335_2_9M


Page 350 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-25,HK-25R,HK-25C,HK-25L,HK-25RL,HK-25CL, HK-25RC,HK-25RCL

HK-2501,HK-2501R,HK-2501C,HK-2501L,HK-2501RL,HK-2501CL,

TRF No. IEC60335_2_9M


Page 351 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2501RC,HK-2501RCL

HK-2502,HK-2502R,HK-2502C,HK-2502L,HK-2502RL,HK-2502CL,

TRF No. IEC60335_2_9M


Page 352 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2502RC,HK-2502RCL

HK-2504,HK-2504R,HK-2504C,HK-2504L,HK-2504RL,HK-2504CL,

TRF No. IEC60335_2_9M


Page 353 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2504RC,HK-2504RCL

HK-2505,HK-2505R,HK-2505C,HK-2505L,HK-2505RL,HK-2505CL,HK-2505RC,HK-
2505RCL

TRF No. IEC60335_2_9M


Page 354 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2506,HK-2506R,HK-2506C,HK-2506L,HK-2506RL,HK-2506CL,

HK-2506RC,HK-2506RCL

TRF No. IEC60335_2_9M


Page 355 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-P24,HK-P24R,HK-P24C,HK-P24L,HK-P24RL,HK-P24CL,HK-P24RC,HK-P24RCL

HK-2401,HK-2401R,HK-2401C,HK-2401L,HK-2401RL,HK-2401CL,

TRF No. IEC60335_2_9M


Page 356 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2401RC,HK-2401RCL

HK-2402,HK-2402R,HK-2402C,HK-2402L,HK-2402RL,HK-2402CL,

TRF No. IEC60335_2_9M


Page 357 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2402RC,HK-2402RCL

HK-23,HK-23R,HK-23C,HK-23L,HK-23RL,HK-23CL,HK-23RC,HK-23RCL

TRF No. IEC60335_2_9M


Page 358 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2301,HK-2301R,HK-2301C,HK-2301L,HK-2301RL,HK-2301CL,HK-2301RC,HK-
2301RCL

HK-2302,HK-2302R,HK-2302C,HK-2302L,HK-2302RL,HK-2302CL,HK-2302RC,HK-
2302RCL

TRF No. IEC60335_2_9M


Page 359 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-22,HK-22R,HK-22C,HK-22L,HK-22RL,HK-22CL,HK-22RC,HK-22RCL

HK-2201,HK-2201R,HK-2201C,HK-2201L,HK-2201RL,HK-2201CL,HK-2201RC,HK-
2201RCL

TRF No. IEC60335_2_9M


Page 360 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-20,HK-20R,HK-20C,HK-20L,HK-20RL,HK-20CL,HK-20RC,HK-20RCL

HK-2001,HK-2001R,HK-2001C,HK-2001L,HK-2001RL,HK-2001CL,HK-2001RC,HK-
2001RCL

TRF No. IEC60335_2_9M


Page 361 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2003,HK-2003R,HK-2003C,HK-2003L,HK-2003RL,HK-2003CL,HK-2003RC,HK-
2003RCL

HK-2004,HK-2004R,HK-2004C,HK-2004L,HK-2004RL,HK-2004CL,HK-2004RC,HK-
2004RCL

TRF No. IEC60335_2_9M


Page 362 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-2304,HK-2304R,HK-2304C,HK-2304RC,

HK-19,HK-19R,HK-19C,HK-19L,HK-19RL,HK-19CL,HK-19RC,HK-19RCL

TRF No. IEC60335_2_9M


Page 363 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-1801,HK-1801R,HK-1801C,HK-1801RC

HK-1802,HK-1802R,HK-1802C,HK-1802L,HK-1802RL,HK-1802CL,HK-1802RC,HK-
1802RCL

TRF No. IEC60335_2_9M


Page 364 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-1803,HK-1803R,HK-1803C,HK-1803RC

HK-16,HK-16R,HK-16C,HK-16RC,

TRF No. IEC60335_2_9M


Page 365 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-16T,HK-16RT,HK-16CT

HK-1601,HK-1601R,HK-1601C,HK-1601RC

TRF No. IEC60335_2_9M


Page 366 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-15,HK-15R,HK-15C

HK-14

TRF No. IEC60335_2_9M


Page 367 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-1201

HK-0906A3T

TRF No. IEC60335_2_9M


Page 368 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-0905A3

HK-09

TRF No. IEC60335_2_9M


Page 369 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-09T

HK-0902

TRF No. IEC60335_2_9M


Page 370 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-0904

HK-0905

TRF No. IEC60335_2_9M


Page 371 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-0906

HK-P12

TRF No. IEC60335_2_9M


Page 372 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-XZ100

HK-XZ100T

TRF No. IEC60335_2_9M


Page 373 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-0908

HK-09M

TRF No. IEC60335_2_9M


Page 374 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-09TM

HK-0902M

TRF No. IEC60335_2_9M


Page 375 of 375 Report No. CQCSCL0116-0178

IEC 60335-2-9
Attachment 1: photo documentation

HK-0904M

TRF No. IEC60335_2_9M

You might also like