You are on page 1of 4

FOOTING 

DESIGN
SERVICE FACTOREDSBC AREA REQL B AREA PROVL B Q ULT

F1 603.9 811.2 100 6.04 2.46 2.46 6.25 2.5 2.5 129.79
6.05
F2 305.1 409.9 100 3.05 1.75 1.75 4.00 2 2 102.48
3.06
F3 242.8 326.1 100 2.43 1.50 1.50 3.06 1.75 1.75 106.48
2.25

TWOWAY PUNCHING SHEAR  PUNCHING SHEAR STRESS

BAR DIA 16 VU 744.48 KN Vp 0.96 Mpa < 1.73 Mpa safe

DEPTH CONC 400 VU 382.51 KN Vp 0.91 Mpa < 1.73 Mpa safe


300
300 VU 297.64 KN Vp 0.71 Mpa < 1.73 Mpa safe
DEPTH 317
217
217 √fc/3 1.73 Mpa
COL SIZE 400 400
350 350
350 350
PHI 0.85
fc 27
fy 420
ONE WAY  BEAM FACTORED SHEAR STRESS

VU 237.84 KN Vp 0.35 Mpa < 0.87 Mpa safe

VU 129.73 KN Vp 0.35 Mpa < 0.87 Mpa safe

VU 94.66 KN Vp 0.29 Mpa < 0.87 Mpa safe


√fc/6 0.87 Mpa

as req asmin

MOMENT 129.79 1.050 2.50 0.5250 178.87 KNm 1520.53 2641.667 govern 14 pcs 16mm both wa

102.48 0.800 2.00 0.4000 65.58 KNm 818.76 1446.667 govern 8 pcs 16mm both way

106.48 0.725 1.75 0.3625 48.97 KNm 593.70 1265.833 govern 7 pcs 16mm both way
ys