Back­Venting Traps Siphon traps, unprotected from siphonage by vent pipes, offer no security whatsoever against the passage of drain air into a
building; therefore, any system of plumbing in which si...

Example Of Back­Venting

An example of back­venting the fixture traps in an ordinary bath room is shown in Fig. 32. The chief conditions to be here noted are: (1) The height
of the vent pipe where it enters the vent stack. It...

Self­Scouring Traps
The chief objection to non­siphon traps heretofore has been that owing to their enlarged bodies they were not self­cleaning, hence they afforded a
fouling place for the deposit of sediment. This objec...

Commercial Types Of Traps
Offset Siphon Trap A common type of siphon trap is the brass trap, Fig. 36. This form of trap has many advantages, among which are the offset
and slip joints, a, which make it adjustable. The pipe o...

Connecting Several Fixtures To One Trap
When a number of wash basins are grouped together in a wash room of a factory, hotel, or other institution it is common practice to connect the
waste pipes from all the basins to one trap. A better pr...

Conditions Governing Use Of Grease Traps
Grease traps should be used to intercept the grease from all kitchen sinks in cities that have installed systems of sewerage from which storm water
is excluded. Under such conditions, the sewers are s...

Location For Grease Traps
A grease trap should be located as close as possible to the sink from which it receives the discharges. It should not be placed in the kitchen,
however, on account of the offensive odors that would en...

Type Of Blow­Off Tanks
A blow­off tank and connections are shown in Fig. 46. Water enters the condensing tank from the boiler through the pipe a. When released from
pressure, some of the water instantly flashes into steam a...

Refrigerator Wastes
System Of Piping In apartment houses, of the better class, refrigerator waste pipes are usually installed to carry off the drip from ice boxes in the
several apartments. Fig. 47 shows the general sys...

Mechanical Discharge Systems
General Consideration Mechanical ejectment of sewage is resorted to in cases where the street sewer is above the level of the area to be drained.
This condition, however, is only found in the sub­bas...

Centrifugal Pump Ejectors
There are three types of apparatus used to raise sewage to the street sewer, each of which has certain features to recommend it. When the volume
of the sewage to be removed is large and the height to ...

Piston­Pump Ejectors
When the volume of sewage to be raised is small or the height it is to be elevated is great, the piston type of pump will give the best results. The
sewage should be screened, however, before entering...

Compressed­Air Ejectors
Air ejectors are now more generally used for sewage ejectment than any other type of apparatus. They are automatic and almost noiseless in
operation, are perfectly odorless, and have but few working p...

Disposal Of Sub­Soil Water
When the street sewer is provided with a sub­sewer drain, as is usually the case in localities where the ground water is high, the proper place to
dispose of sub­soil water is in the sub­sewer drain. ...

Testing Drainage Systems
Methods Of Testing Two tests, a roughing test and a final test, should be applied to the drainage system in every building. The roughing test may
consist of a water test or an air test, The water tes...

Plugs For Traps
Special plugs are now made to stop the outlets to traps. Formerly it was common practice to fill the bottom of the main drain trap with Portland
cement, or calk a disk of sheet lead into the drainage ...

Drainage System Testing In Sections
It is sometimes necessary to test a drainage system in sections, so as not to delay the completion of other parts of the work. When testing in
sections, all parts of the drainage system should be subj...

Compressed Air Drainage System Test
The air test is applied by closing all openings, and then forcing air into the drainage system by means of an air compressor, until there is a uniform
pressure of about 10 pounds per square inch throu...

Water Supply Systems ­ Cold Water Supply Properties Of Water

http://chestofbooks.com/home­improvement/construction/plumbing/Principle­Practice/index.html 3/11