1 2
TRUSTED MANUFACTURING
SOURCE FACILITIES
LEGACY OF HOUSTON TX. USA
EXCEPTIONAL SERVICE MUSCAT OMAN
OVER
40 #1
YEARS LEADER
PRIVATELY OWNED IN THE DESIGN, MANUFACTURE, AND
AND OPERATED INSTALLATION OF SURFACE EQUIPMENT
FOR THE OIL & GAS INDUSTRY
1 5
SUPPLIER SPECIALTIES
TURNKEY PROVISION OF YOUR PROJECT ENHANCED RECOVERY OF HEAVY OIL,
WE DESIGN, ENGINEER, MANUFACTURE GAS GATHERING & OIL PRODUCTION FACILITIES
INSTALL, COMMISSION, SERVICE, OIL & GAS PIPELINE EQUIPMENT
TRAIN & OPERATE METERING & MEASUREMENT
OEM TO END USERS IN THE REFINING, POWER,
FERTILIZER AND OTHER PROCESS INDUSTRIES
(2)
Custom LACT - Provers
4 General Information
8 Lact Components
10 Standard DAN-ACT
11 Coriolis Meters
13 Meter Provers
15 Projects
(3)
Custom LACT - Provers
Engineering personnel within Manufacturing supervision and Through our ISO 9001, 14001
EN-FAB provide a full range of fabrication personnel work with and OSHAS 18001 Quality
services from complete our engineering and quality Assurance and Safety
engineering design, through assurance staff as a team to Programs, EN-FAB, Inc. assures
shop fabrication and/or shop provide our customers with: the equipment we design and
built drawings as the project manufacture meets or exceeds
requires. • An ASME 'PP' 'S' 'U' 'U2' the requirements of our
coded and National Board customers by providing:
EN-FAB’s staff provide a design of Boilers & Pressure Vessel
approach, tempered with Inspectors 'R' Certified • Multiple, intensive
experience, to fit your specific fabrication facility inspections and testing at
needs in accordance with • A quality product fabricated key stages during
recognized industry standards. in accordance with manufacturing
manufacturing standards • Quality assurance manuals
This is accomplished through • A safe and reliable system designed to supply detailed
personnel knowledge in the • 2 modern manufacturing guidance for manufacturing,
applications of: facilities equipped with the inspection and testing
proper equipment and • In-house testing to assure
• Process design and tools, located in Houston, that manufactured products
operation requirements Texas, USA. and Muscat, will perform to our
• Modern manufacturing Oman. customers standards.
techniques
• Proper materials selection
• Domestic and International
mechanical, electrical and
instrumentation standards
and codes
• Engineering standards for
consistent design and ease
of installation, start-up
operation and maintenance
• Mechanical and process
applications. LACT Unit ready to ship from EN-FAB facility Houston, TX. USA
(4)
Custom LACT - Provers
Caustic Membrane Metering System, with Dual meters, Prover, and 4 way valves for Sonatrach, Hassi Berkine Field
The long-term business success A unique material control EN-FAB provides the tools and
of EN-FAB depends on our system including scheduling, expertise you need to optimize
ability to ensure that HSE expediting, and rigid incoming your commissioning, training
remains a top priority for all inspection, coupled with expert and start-up activities.
employees and contractors. scheduling of manpower and
facilities allocation provides Our Design, Build, Own,
The EN-FAB HSE policy is scheduled shipments. Operate, and Maintain program
applied throughout the (DBOOM) ensures the safe and
company. Each employee This system together with seamless transition of your
must maintain up-to-date EN-FAB’s dedication to project through all stages from
certifications in essential HSE commitments assures on-time conception to final operation.
training courses. delivery.
(5)
Custom LACT - Provers
Crude Metering Station Azerbaijan, South Caucasus region of Eurasia, featuring Lease Automated Custody Transfer Unit (LACT), Prover and Analyzer
(6)
Custom LACT - Provers
(7)
Custom LACT - Provers
(LACT) Components
A liquid meter is, in essence, a hydraulic motor with high volumetric efficiency that absorbs a small
amount of energy from the flowing stream. This energy is used to overcome internal friction in
driving the meter and its accessories and is reflected as a pressure drop across the meter. Pressure
drop is regarded as a necessary evil that must be minimized. Pressure drop across the internals of a
PD meter actually creates a hydraulically unbalanced rotor, which causes rotation.
Positive displacement flowmeters are some of the most accurate flowmeters available today and
have long been the standard of measurement for liquid hydrocarbons such as crude oil.
They can easily obtain flow measurements within 0.1% of the true value, and are unique because
they are the only type of flowmeter that directly measures the volumetric flowrate.
Mechanical adjuster
• Mechanical Adjuster
• Measuring Unit
• Housing
Measuring unit
housing
(8)
Custom LACT - Provers
Conventional Operation
Basic LACT Operation Standard Components
Shown below is a typical producing lease • Charge Pump and Motor
surface equipment flow pattern. • Combination Strainer-gas Eliminator
After produced oil has been through the • BS&W Monitor & Probe
separator and/or heater treater it is sent to the 3-way, 2-position Electro Hydraulic or
stock tank. Oil is pumped from the tank through Pneumatic Diverting Valve
the LACT unit when it reaches a predetermined • Positive Displacement Meter with ATC, Right
level in the stock tank. The electrical signal is Angle Drive, and small numeral register
initiated through a static head switch or level (non-resetable)
controls to the holding coil of the charge pump • 3-valve Prover Manifold
prime mover on the LACT unit. If the BS&W • Back Pressure Valve
(Basic Sediment & Water) content is below a • Sampling System with Container & Electric
preset acceptable percentage, the oil is pumped Mix Pump
through the sales meter to the pipe line. If, how- • Control Panel, Control Relays, Visible Panel
ever, the BS&W content is above an acceptable Lights for Oil By-passing, Merchantable Oil &
level, the oil is automatically returned to the Meter failure, Pressure Gauges.
process equipment or a holding tank for further
processing. All LACT units, unless specified otherwise, are
Any time marketable oil is pumped through the fully FAT tested, plug-and-play, and require only
LACT unit to the pipe line, a proportionate minimum external electrical connections.
sample of the oil is automatically obtained and
stored in a vapor proof container. This
composite sample is later used for gravity and
BS&W verification.
Upon reaching low stock tank level, the LACT
unit charge pump will stop and not start again
until a high or run level is reached in the tank.
(9)
Custom LACT - Provers
Configuration 1.
Standard LACT Bare bones" skid-mounted unit for accurate measurement of liquid
Configurations flow. The meter automatically registers throughput. Back-pressure
valve insures full meter. Strainer protects meter from damage by
particulates in flow stream. Tees provided for proving meter while
inline. Double-block-and-bleed valve between proving tees insures that
Config. 1. all flow is diverted through prover.
This low-cost unit particularly suited to applications involving
infrequent proving.
“Standard” options:
• Deaerator
Config. 2.
• Centrifugal charge pump package
• Outlet check valve
Configuration 2.
Desirable if proving needed regularly. All components of Configuration
1.plus valves on proving tees and indicators for pressure and
temperature.
Config. 3. Additional “standard options:
• Hose connections for quick hookup to portable prover.
Configuration 3.
Used if representative sample of product required. An automatic
sampling system verifies product quality before sale or shipment.
Config. 4. Configuration 4.
Provides components commonly called for in Lease Automatic Custody
Transfer (LACT) units. Can detect a preset water content and divert
”bad” oil to treatment tank (especially useful when intermittent slugs of
2500
water are expected in the flow.
Configuration 5.
Flow control provided by flow control computer which eliminates need
Config. 5.
for mechanical meter registers, ticket printers, and mechanical
calibrators. Once portable-prover inlet, outlet, and detector switches
are tied to LACT unit, the computer performs all meter-factor and
2500 flow-factor calculations internally.
Configuration 6.
“Top of the line” LACT unit. A charging pump and deaerator are
Config. 6.
standard.
(10)
Custom LACT - Provers
Coriolis Meters
LACT units are designed for unattended custody transfer of crude oil from a seller to a buyer.
The LACT design is determined by:
• Flow rate
• Operating pressure
• Gravity
• Temperature of the oil
• Minimum pressure drop through the piping and components is desirable.
LACT units have traditionally been fitted with positive-displacement meters, but a turbine meter
can be used with certain types of fluid. Many LACT units utilize Coriolis meters as they can
provide lower costs and have no moving parts.
Drive Coil
Case
Pickoff
Coils
Flow Tube
Resistance
Thermal device
(RTD)
Process Process
Connection Connection
Flange Flange
Flow
(11)
Custom LACT - Provers
Packaged LACT skid for handling 25,000 BPD maximum of crude oil
(12)
Custom LACT - Provers
Meter Provers
Eliminate Measurement Uncertainty
EN-FAB manufactures, functionally test, and Design and Operating Data (Bi-Directional Unit below right)
(13)
Custom LACT - Provers
Meter Provers
Verification and/or checking the accuracy of The petroleum industry and American Petro-
liquid meters can be done with a device known as leum Institute (API) have accepted the use of
a liquid displacement meter prover. Meter provers volume displacement provers in two categories.
can be stationary or mobile. They can be 1. The conventional pipe prover is a displacement
bi-directional, unidirectional, piston type and small prover with sufficient reference volume to
volume type. accumulate 10,000 whole pulses in a single pass;
Meter provers are automated systems used to 2. The captive displacement or small volume prover
provide on-site calibration to verify flow meter (SVP) is a displacement prover with insufficient
uncertainty and establish the K-factor of a meter. reference volume to accumulate 10,000 pulses in a
Provers are designed in accordance to the space single pass and uses pulse interpolation software).
available and the type of product to be proved, In both cases, it will require multiply passes for
however, they must all be sized to accommodate a proving and to establish as new meter factor.
the flow rates of the meters to be proved. Conventional provers have been utilized for
EN-FAB meter provers are in accordance with, meter proving since the early 1950’s, captive
and will meet the standards set forth by the displacement prover entered the market in the mid
American Petroleum Institute (API) and the 1970’s after the acceptance of the double
International Organization for Standardization chronometry or pulse interpolation (techniques
(ISO) which whole meter is counted between detector
switch one and detector switch two and any
remaining fraction of a pulse in calculated) as
identified in API MPMS Chapter 4.6.
(14)
Custom LACT - Provers
Equipment Provided:
• One 800,000 BPD Crude Measurement skid assembly with two
3-10” meter streams.
• One 15’ x 45’ 820,000 BPD Bi-directional Meter Prover assembly
with 30” prover pipe section.
• One Control cabinet containing three OMNI flow computers,
one dedicated to each meter stream, two programmable logic
controllers, sediment and water monitor, function switches,
and other miscellaneous devicesble logic controllers.
• One Master Station Controller
(15)
Custom LACT - Provers
Since the pipeline opened in 1977, over 20,000 tankers have come and
gone from the Valdez terminal, carrying more than 15 billion barrels of oil
to refineries near Seattle, San Francisco, and Los Angeles.
Scope
Block, Outlet & Test, Solenoid, Thermal Relief & Control Valves
Trailer Specifications
Overall Interior Rear Door Capacity
Length Width Height Length Width Height Width Height
48 ft 102” 13’ 6” 47’ 6” 98.5” 100.6” 98” 100.6” 3,465 cu ft
(16)
Custom LACT - Provers
Customer: Pemex
Gulf of Mexico
MEXICO
Poza Rica
Viscosity: 0.08 cP
Service Sweet
(17)
Custom LACT - Provers
EN-FAB Metering Package with Quality loops and control system located in Tengiz, Kazakhstan.
Stretching over 1,500 kilometers from the country's giant Tengiz oil field to
the Russian port of Novorossiysk on the Black Sea, The Caspian Pipeline
Consortium (CPC) oil pipeline was commissioned in 2001. As the first
major pipeline to be built from a former Soviet country, the route was the
Launchers & Receivers at Tengiz Pump Station
result of years of planning and effort.
The $2.5 billion project crosses Russian territory north and west of the
Caspian, at full capacity the pipeline handled 67 million tons, the equivalent of over 1.3 million barrels per day, and
https:/ www.oxy.copipeline.
is so long that it initially took 105 days to fill the entire m/investors/Documents/Earnings/OXY3Q13ConfCal Slides.pdf
(18)
Custom LACT - Provers
MAYAKAN PROJECT
FACTS
ENERGIA MAYAKAN - YUCATAN PENINSULA GAS PIPELINE, MEXICO
ENERGIA MAYAKAN
AT A GLANCE
Year: 1999
EN-FAB Metering and Pressure Regulation System located on the Yucatan Peninsula, Mexico
Mont Belvieu
• Gasoline Meter/Gasoline Prover
• Ethylene Meter
• Mainline Block Valve
• 12" Gasoline Pipeline,
• Propylene Meter/Propylene Prover
Port Arthur
• Gasoline Meter/Gasoline Prover
• Ethylene Meter
• Mainline Block Valve
• 12" Gasoline Pipeline,
• Propylene Meter
• Propylene Prover
(20)
Custom LACT - Provers
(21)
Custom LACT - Provers
GDI SICIM Pipeline S.A. Encino-La Laguna Pipeline 42 “ Launcher and Receiver (Pig Traps)
Hocol /Shell Colombia LACT Unit and Meter Prover
Ienova Infraestructura San Isidro - Samalayuca 153-850 MMSCFD Ultrasonic Metering System w/Control
Lancaster Steel Colombia LACT Unit and Meter Prover
(22)
Custom LACT - Provers
(23)
Custom LACT - Provers
(24)
Custom LACT - Provers
Capability Statement
“Serving the Oil & Gas Industry Since 1980”
About Us
Contact Information EN-FAB, Inc. is a multi-discipline company offering design, fabrication, service, training and operation of surface
EN-FAB, Inc. Houston equipment for the Oil & Gas Industry. EN-FAB currently has 93 full time employees including 6 Professional
3905 Jensen Drive Engineers, Inspectors, Technicians and other experienced support staff. 2 Manufacturing facilities, located in
Houston, TX. 77026 Houston Texas and Muscat, Oman with total under roof fabrication area of 331,674 sq. ft. and 12 acres of
Phone: +1 713 225-4913 paved/concrete yard.
Fax: +1 713 224-7937
email: sales@en-fabinc.com
www.en-fabinc.com
History
Founded by Daniel Industries, Inc., and privately owned since 1995, our growth and success is the result of
EN-FAB, Inc. Mexico sound fiscal management the conscientious performance of our very committed employees and our responsive
Reforma 222, Tower 1, Floor 18 service and our ability to provide quality products and services to our clients.
Col. Juarez, Delegacion Cuauhtemoc
CP 06600, Mexico Geographical Reach
Contact: Alejandro Trujano EN-FAB, Inc. is a global supplier to the Oil, Gas and Petrochemical Industries. Major installations can be found
Mobile: 044 55-1353-6859
in: USA, Algeria, Argentina, Bahrain, Bolivia, Brazil, Cameroon, Canada, Chile, Colombia, Ecuador, Egypt, Gulf
Office: +1 713 635-9053
email: atrujano@en-fabinc.com of Mexico, Kuwait, Mexico, Nigeria, Oman, Peru, Russia, Saudi Arabia, Tanzania, Trinidad, Turkey, and
Venezuela.
EN-FAB, Inc. Bakersfield, CA
11420 Cederhaven Ave. Our Clients
Bakersfield CA. 93312 EPC’s Oil & Gas Pipeline Companies
Contact: Dane Anderson Major Oil & Gas Producers End User Processing Plants & Facilities
Phone: +1 661 472-5553
email: danderson@en-fabinc.com
EN-FAB Unique Strengths & Focus Area
EN-FAB International Metering & Measurement
Oman Metal Industries Gas Measurement Stations Pressure Regulating Skids
Plot 900, Road 9 Liquid Metering Stations Meter Provers
Rusayl Industrial Estate
City Gate Stations Quality Analyzer Systems
Rusayl, Muscat 123
Sultanate of Oman Control Systems
Contact: Mr Rajshekhar
Phone: 011-968-24446132
Gas Gathering & Oil Production
Fax: 011-968-24446179 Early Production Facilities Production & Test Manifolds
email: rajshekhar@omi.om Modular Production Systems Heater Treaters
www.omanmetalindustries.com Production & Test Separators Thermal Liquid (Hot Oil) Heaters/Systems
Well Testing Equipment Indirect and Direct Fired Heaters
Desalters
Performance - Provide quality products Quality - Maintain a real commitment to Teamwork - Establish and maintain
& services within schedule and on budget quality and strict adherence to industry a teamwork environment and relationship
standards with the client
//20 Rev.
(25)
Equipment Offerings
EN-FAB Designs and Manufactures the Following Equipment for Oil and Gas Industry.
EN-FAB also owns, operates and maintains oil field surface equipment.
B. C. D. E.
Gas Oil & Gas Metering & End Users:
Gathering Pipeline Measurement Refinery,
(26)
Surface & Oil Equipment ofOil
Oil&&Gas
Gas Power Plants,
Production Fertilizer
Facility Plants, etc.
Produced fluid
Systems Heaters & Systems
x E.O.R. HRSG
x Early Production x Filter Separators x Direct & Indirect
x DAN-SQUID® 2-Phase Steam Reservoir Facility x Pipeline GasBlowdown Fired Heaters
Distribution System x Modular Production Systems x Gas Measurement x Desalters
Systems x Scrubbers Stations x Demulsifiers
x DAN-STM® Steam Quality & Mass
x 2 & 3 Phase Separators x Mainline BlockValve x Pr. Regulating / x Gas Measurement
Flow Measurement System
x Production & Test Skids Reducing Skids Stations
x Steam Quality & Mass Flow x Quality Analyzer
Separators x Liquid MeteringStns x Pressure Regulating
Measurement using Steam Separator Systems
x Production & Test x Meter Provers & Reducing Skids
x Water-Flood Packages Manifolds x LeakDetection Unit x Leak Detection Units x Fuel Gas Cond.
x Free Water Knockout x Quality Analyzer x Control Systems & Systems
x Chemical Injection Packages
Skids System Panels x Liquid Metering
x Deaerators x Produced Water x LACT Units Stations
x Slug Catchers
Packages x Gas Deaerators x Meter Provers
x Build, Own, Operate Maintain x Surge ControlSystems
Steam Injection Facilties x Heater / Treater x /DXQFKHUV 5HFHLYHUV x Strainers
EN-FAB, Inc. 3905 Jensen Drive, Houston, Texas 77026 U.S.A. Phone: 713-225-4913 Fax: 713-224-7937 E-mail: sales@en-fabinc.com Website:www.en-fabinc.com
Custom LACT - Provers
For over 40 years, EN-FAB has been entrusted source for the engineering,
design, and fabrication of surface equipment to some of the largest
Oil & Gas companies.
(27)
Custom LACT - Provers
EN-FAB, Inc.
3905 Jensen Drive,
Houston, TX. 77026
Phone: 713 225-4913
Fax: 713 224-7937
www.en-fabinc.com
ISO 9001
ISO 14001 OSHAS
18001
EN-FAB® is a Registered Trademark of EN-FAB, Inc.
01/27/2021