You are on page 1of 1

Technical Tips

Subject: Check Cable Routing on AZ Axis


Attn: Field Engineers / Support
Related Model: v85NX, v100NX, GX100NX, v100NX Ka, v85NX Ka

1. Overview
It has been reported that there are few cable damages on the NX series related to AZ Axis
as below. Belows pictures indicate the cable damages near the AZ Axis. As you can see,
cables may get stuck in belt guides or get caught in other structures.
QA team already has revised the cable routing from May 15, 2020.

2. Routing Guide
Tie the AZ Motor Cable, Rotary-Joint Cable, and Slip-Ring Cable with cable tie at the point
“B” 100mm away from cable tie “A”.

In case that support members encountered AZ issue for the applicable antennas, please
have an ETO or field engineer investigate AZ axis.

Intellian Technologies, Inc. Page 1 / 1


This document is proprietary to Intellian Technologies, Inc. and must be treated on a confidential basis. It may be used solely for the purposes intended by Intellian Technologies, Inc. Use or
disclosure of this document, or the information contained herein, for any other purpose is not permitted without prior written authorization.