You are on page 1of 1
COTES COUR CAT Cag ‘Absolute Centipoise Poise ‘Slugs "Pound or Dynamic Gram Ft Sec Ft Sec Viscosity Cm Sec “Pound, Sec Poundal Dyne Sec Fu Fe Cm* ww, (100 4) (ue) (ue) Centipoise Gy 1 0.01 2.09 (10*) 6.72 0%) Poise Gram Cm Sec 100 100 1 2.09 (10%) 0.0672 Dyne Sec Cm* Slugs LESS (ue) 47-900 479 1 gor 32.2 Pound See Be ‘Pounds EES (ute) 1487 14.87 for .0311 1 Poundal Sec Fe “Pound, = Pound of force ‘Pound = Pound of mass ‘To convert absolute or dynamic viscosity from one set _ As an example, suppose a given absolute viscosity of 2 of units to another, locate the given set of units in the poise is to be converted to slugs/foot second. By refer- left hand column and multiply the numerical value by ring to the table, we find the conversion factor to be the factor shown horizontally to the right under the set 2.09 (10°). Then, 2 (poise) times 2.09 (10°) = 4.18 (10) of units desired. = 0.00418 slugs/foot second. Tor) Ua ag Kinematic Viscosity Centistokes Stokes Fe Cm? Sec Sec o oovy ow Centistokes @ I 0.01 1.076 G09 Stokes feng oovy 100 1 1.076 0%) Sec re se, ow 92.900 929 1 Sec ‘To convert kinematic viscosity from one set of units to. Asan example, suppose a given kinematic viscosity another, locate the given set of units in the left hand 0f 0.5 square foot/second is to be converted to column and multiply the numerical value by the centistokes. By referring to the table, we find the factor shown horizontally to the right under the set conversion factor to be 92,900. Then, 0.5 (sq ft/sec) of units desired. times 92,900 = 46,450 centistokes.