You are on page 1of 6

SICK Configuration & Diagnostic

Software

S300 laser scanner Configuration protocol


(COM8)
SICK Configuration & Diagnostic Software

Contents

1. Configuration protocol S300 [H] from 24/02/2020, 08:28...................................................... 3


1.1. Version information......................................................................................................................... 3

1.2. General information........................................................................................................................ 3

1.3. System parameters........................................................................................................................ 3

1.4. Resolution/scanning range............................................................................................................. 3

1.5. Incremental encoder....................................................................................................................... 3

1.6. Inputs.............................................................................................................................................. 4

1.7. OSSDs............................................................................................................................................ 4

1.8. Restart............................................................................................................................................ 4

1.9. Universal I/O................................................................................................................................... 4

1.10. Configuration of the measured data output.................................................................................... 4

1.11. Cases............................................................................................................................................. 4
1.11.1. Monitoring case 1.................................................................................................................. 4

1.12. Field sets........................................................................................................................................ 5

Page 2
SICK Configuration & Diagnostic Software

1. Configuration protocol S300 [H] from 24/02/2020, 08:28

S300 [H] Laser scanner

1.1. Version information


Version number CDS 3.7.2.122
Software version DLL 3.7.2.122
Created with CDS 3.7.2

1.2. General information


Type code S30B-3011BA
Device name S300 H
Serial number 17090802
Serial number (Scanner) 17090802
Serial number (System plug) 17030180
Software version (CPU A) 02.10
Software version (CPU B) 02.10
Sensor head Long Range (3.0 m)
I/O module Standard

Safety Configuration ID (SCID) 0xD422

Status in testing

1.3. System parameters


Name of the user Default
Application name Safety Solution
Rotation of the 7segment display Rotated by 0°

1.4. Resolution/scanning range


Application variant Mobile
Resolution protective field 70 mm (leg detection)
Basic response time 80 ms
Maximum protective field range 300 cm
Angular resolution 0.5 °

1.5. Incremental encoder


Signal velocities Inactive

Page 3
SICK Configuration & Diagnostic Software

1.6. Inputs

Control inputs (Permanently)


Input source S300 [H] [S300 H]
Input delay 10 ms
Sampling for the static control inputs Complementary

1.7. OSSDs
Object in the protective field switches OSSDs Local
External device monitoring Active

1.8. Restart
Restart internal OSSDs With restart interlock

1.9. Universal I/O

Uni I/O 1 Uni I/O 2 Uni I/O 3 Uni I/O 4 Uni I/O 5
(Pin5) (Pin6) (Pin13) (Pin14) (Pin15)

Inputs
External device monitoring - x
Reset x -

Outputs
Contamination warning x - -
Contamination error x - -
Reset required - - x
Error - - -
Protective field - - -
Warning field 1 - x -
Warning field 2 - x -

1.10. Configuration of the measured data output


Baud rate 19200 Baud
Silent Time 5000ms
Send mode Data output only on request

1.11. Cases
Number of monitoring cases 1

1.11.1. Monitoring case 1


Monitoring case name Case 01

Page 4
SICK Configuration & Diagnostic Software

Park mode Inactive


Allocated field set Field set 1
Multiple sampling 3

Activation of the inputs


No inputs used

1.12. Field sets


Number of field sets 1

Field set 1 "Field set 1"


Protective field

Page 5
SICK Configuration & Diagnostic Software

Warning field 1

Warning field 2

Page 6