ISOLATED 

FOOTING DESIGN
SERVICE FACTORED SBC AREA REQ L B AREA PROV L B Q ULT

F1 200 294 100 2.00 1.42 1.42 2.25 1.5 1.5 130.67
2.02
F2 98 144 100 0.98 1.00 1.00 1.21 1.1 1.1 119.01
1.00
F3 70 108 100 0.70 0.84 0.84 0.81 0.9 0.9 133.33
0.71

TWOWAY PUNCHING SHEAR  PUNCHING SHEAR STRESS

BAR DIA 16 VU 244.26 KN Vp 0.52 Mpa < 1.52 Mpa safe

DEPTH CONC 350 VU 98.69 KN Vp 0.23 Mpa < 1.52 Mpa safe


350
300 VU 72.36 KN Vp 0.19 Mpa < 1.52 Mpa safe
DEPTH 267
267
217 √fc/3 1.52 Mpa
COL SIZE 250 400
200 400
300 300
PHI 0.85
fc 20.7
fy 275
ONE WAY  BEAM FACTORED SHEAR STRESS

VU 60.37 KN Vp 0.18 Mpa < 0.76 Mpa safe

VU 14.14 KN Vp 0.06 Mpa < 0.76 Mpa safe

VU 9.96 KN Vp 0.06 Mpa < 0.76 Mpa safe

√fc/6 0.76 Mpa

as req asmin

MOMENT 130.67 0.575 1.50 0.2875 32.40 KNm 504.00 2672.727 govern 14 pcs 16mm both ways

119.01 0.375 1.10 0.1875 9.20 KNm 818.76 1960.00 govern 10 pcs 16mm both ways

133.33 0.300 0.90 0.1500 5.40 KNm 593.70 1374.545 govern 7 pcs 16mm both ways