Result FAIL

Parameter : Conducted Emission Test

1. SINARLUX, LED Street Light


YL02D 120 Watt
Fail in conducted Emission Test, Test Mode 100V_L

No Frequency QPeak Limit Delta Limit Delta Factor


[MHz] [dB µV] [dB µV] [dB] [dB µV] [dB] [dB]
QP QP AVG AVG LISN
1 0.059 91.90 88.49 3.41 78.49 13.41 9.76
2 0.0591 92.99 88.48 4.51 78.48 14.51 9.76
3 0.0592 93.54 88.46 5.08 78.46 15.08 9.76
4 0.0593 93.55 88.45 5.10 78.45 15.10 9.76
5 0.0594 92.49 88.43 4.06 78.43 14.06 9.76

Dinyatakan fail karena, sample mengeluarkan emission melebihi limit yang ditetapkan pada CISPR 15
Detail dapat dilihat pada tabel di atas dan terlihat bahwa nilai Qpeak > Limit QP  Fail