You are on page 1of 1

Pergudangan 

99 Blok R.8, Jalan Raya Salembaran Tangerang
Pergudangan 99 Blok R.8, Jalan Raya Salembaran Tangerang
Telp : 021 ‐ 22550092 / 021‐22550079 Fax. : 021 ‐ 22550077
email : diwanbudiperkasa@gmail.com

DESIGN CALCULATION

PROJECT NAME : SIZE UP LINE BRINE D‐200B DOC No. : T4/23/SA‐72/0621


PROJECT CODE : SA‐72 Rev/Page : 1 / 4 OF 13
CUSTOMER : PT. SULFINDO ADIUSAHA DATE : 30 Juni 2021

MECH. CALCULATION
FRP EQUAL TEE
ASME NM 2 ‐ 2018

3. Design For FRP Equal Tee
Thickness design By HLU methode With 10 BarG Internal Pressure
h k h h l

PD R Reffer ASME NM 2 ‐ 2018 Page 14
t = m
2S

Where :
‐ Inside Diameter of Main Run Structur Wall, DR = (Di + 2c)
‐ Pressure Stress multiplier for integral tees, m
0.25
m = 1.4λZ 
‐ Design Pressure, P = 10 BarG = 1 Mpa
‐ Hoop Tansile Stranght, S = 20.68 Mpa AWWA 950 Table 10 Page 18 ( 3000 Psi)

Tabel.2 Summary Thickness of FRP Equal Tee
y q
P S L Min. Thick Use thicknes
No Pipe Dia c DR λZ m
Di(mm) (mm) (mm) (Mpa) (Mpa) (mm) t (mm) t + C (mm)
1 350 3 356 8.48 1.86 1 20.68 556 16.0 19.0
2 300 3 306 10.20 1.94 1 20.68 506 14.4 17.4
3 25 3 31 1.19 1.14 1 20.68 231 0.9 7

Note :
‐ the use of thicknes has been adjusted to what is offered
‐ Use laminate type 2