You are on page 1of 1

*** Overall summary for all load cases - Usage = Maximum Stress / Allowable Stress

Summary of Steel Pole Usages:

Steel Pole Maximum Load Case Segment Weight


Label Usage % Number (N)
--------------------------------------------
Trial 92.43 WL+2.1TL 8 4954.1

*** Maximum Stress Summary for Each Load Case

Summary of Maximum Usages by Load Case:

Load Case Maximum Element Element


Usage % Label Type
------------------------------------------
WL+2.1TL 92.43 Trial Steel Pole
WL+TL 82.67 Trial Pole Deflection

Summary of Steel Pole Usages by Load Case:

Load Case Maximum Steel Pole Segment


Usage % Label Number
-------------------------------------
WL+2.1TL 92.43 Trial 8
WL+TL 46.88 Trial 8

Summary of Insulator Usages:

Insulator Insulator Maximum Load Case Weight


Label Type Usage % (N)
---------------------------------------------
C1 Clamp 21.33 WL+2.1TL 0.0

Pole Deflection Usages For All Load Cases:

Pole Load Case Deflection Deflection Height Length Tip Allowable Actual Deflection From Usage
Label Check Limit Diameter Deflection Deflection Vertical Axis
% (m) (m) (cm) (m) (m) (m) %
------------------------------------------------------------------------------------------------------------
Trial WL+TL % Pole Height 3.00 11.10 13.00 18.00 0.33 0.28 0.28 82.67

Loads At Insulator Attachments For All Load Cases:

Load Insulator Insulator Structure Structure Structure Structure Structure


Case Label Type Attach Attach Attach Attach Attach
Label Load X Load Y Load Z Load Res.
(kN) (kN) (kN) (kN)
-------------------------------------------------------------------------------
WL+2.1TL C1 Clamp Trial:1 0.000 16.800 3.000 17.066
WL+TL C1 Clamp Trial:1 0.000 8.000 1.500 8.139

Overturning Moments For User Input Concentrated Loads:

Page 10/11