PIPES AND FITTINGS

ESLON U-PVC PIPE


●U-PVC PIPE FOR PORTABLE WATER(ESLON VPW & HI-PipeGold+(plus)[HI-VPW・G])
Excellent corrosion resistance.
Conform to Food Sanitation Law.
Durable flow rate with smooth inner surface as

D
d
L
no scale or rust.

t
Eslon HI pipe has more than twice of impact
strength compared to normal PVC type.

■Size Unit:㎜
Tolerance L Weight
(kg/m) Standard
Important Notes
Size D t d
Max/min Average JIS K 6742 AS20 HI-VPW-G VPW JIS K 6742 AS20 Do not use for acid, such as sulfuric acid or
13 18.0 ±0.20 ±0.2 2.5 ±0.20 13.0 +30
4000   − 0.170 0.174 HI/VPW −
hydrochloric acid. For acid chemical
−10
+30 application, plant VP pipe is usable.
16 22.0 ±0.20 ±0.2 3.0 ±0.30 16.0 4000
−10
  − 0.251 0.256 HI/VPW −
20 26.0 ±0.20 ±0.2 3.0 ±0.30 20.0 4000 +30
−10
  − 0.303 0.310 HI/VPW −
25 32.0 ±0.20 ±0.2 3.5 ±0.30 25.0 4000 +30
−10   − 0.439 0.448 HI/VPW −
30 38.0 ±0.30 ±0.2 3.5 ±0.30 31.0 4000 +30
−10   − 0.531 0.542 HI/VPW −
+30
40 48.0 ±0.30 ±0.2 4.0 ±0.30 40.0 4000 +30
−10 5000
−10 0.774 0.791 HI/VPW −
+30 +30
50 60.0 ±0.40 ±0.2 4.5 ±0.40 51.0 4000 −10 5000 −10 1.098 1.122 HI/VPW −
+30 +30
65 76.0 ±0.50 ±0.2 4.5 ±0.40 67.0 4000 −10 (5000)−10 1.415 1.445 − HI
+30 +30
75 89.0 ±0.50 ±0.2 5.9 ±0.40 77.2 (4000)−10 5000 −10 2.156 2.202 HI/VPW −
+30 +30
100 114.0 ±0.60 ±0.2 7.1 ±0.50 99.8 (4000)−10 5000 −10 3.338 3.409 HI/VPW −
+30 +30
125 140.0 ±0.80 ±0.5 7.5 ±0.50 125.0 4000 −10 (5000)−10 4.370 4.464 − HI
+30 +30
150 165.0 ±1.00 ±0.3 9.6 ±0.60 145.8 (4000)−10 5000 −10 6.561 6.701 HI/VPW −
+30
200 216.0 ±1.30 ±0.7 11.5±0.70 193.0   − (5000)−10 10.338 10.129 − −
+30
250 267.0 ±1.60 ±0.9 14.2±0.90 238.6   − (5000)−10 15.781 15.481 − −
+30
300 318.0 ±1.90 ±1.0 17.0±1.10 284.0   − (5000)−10 22.494 21.962 − −
・Weight is calculated with specific gravity HI-VPW-G: 1.40, VPW: 1.43 for reference.
・For 65A and 125A, they authorized by JWWA as AS20.

●U-PVC PIPE(ESLON VP, VU)JIS K 6741


VP VU HI

D
d
t

Excellent corrosion resistance. ■Size Unit:㎜

t d
Durable flow rate with smooth Size
Tolerance
L
Weight
(kg/m)

inner surface as no scale or rust. D VP VU HI VP VU HI VP VU HI


40 48 ±0.2 3.6+0.8 1.8+0.4 − 40 44 − 0.791 0.413 −
50 60 ±0.2 4.1+0.8 1.8+0.4 − 51 56 − 1.122 0.521 −
65 76 ±0.3 4.1+0.8 2.2+0.6 − 67 71 − 1.445 0.825 −
75 89 ±0.3 5.5+0.8 2.7+0.6 − 77 83 − 2.202 1.159 −
PIPES AND FITTINGS

100 114 ±0.4 6.6+1.0 3.1+0.8 − 100 107 − 3.409 1.737 −


125 140 ±0.5 7.0+1.0 4.1+0.8 − 125 131 − 4.464 2.739 −
150 165 ±0.5 8.9+1.4 5.1+0.8 − 146 154 − 6.701 3.941 −
200 216 ±0.7 10.3+1.4 6.5+1.0 10.3+1.4 194 202 194 4000±10 10.129 6.572 10.338
250 267 ±0.9 12.7+1.8 7.8+1.2 12.7+1.8 240 250 240 15.481 9.758 15.781
300 318 ±1.0 15.1+2.2 9.2+1.4 15.1+2.2 286 298 286 21.962 13.701 22.494
350 370 ±1.2 − 10.5+1.4 − − 348 − − 18.051 −
400 420 ±1.3 − 11.8+1.6 − − 395 − − 23.059 −
450 470 ±1.5 − 13.2+1.8 − − 442 − − 28.875 −
500 520 ±1.6 − 14.6+2.0 − − 489 − − 35.346 −
600 630 ±3.2 − 17.8+2.8 − − 592 − − 52.679 −
1.350∼600A : Only VU Pipe is available.