INS— 1462 Rev 1.0 PORTABLE HC/O2 MONITOR MODEL RX-415 OPERATION MANUAL ; ee | MARINE USE For HC gas use ]Model RX415 (TYPE HO) Measuring range : HC : 0-100%LEL, 0-100voI% 02 : 0-25vol% For CH4 gas use |Model RX-415 (TYPE CHa) Measuring range : CH4 : 0-100%LEL, 0-100voI% 02:0-25v0l% Precaution in operation * After reading this manual wel, start to operate this nstument. + Keep this manual where to camry out easily * When take out this manual by use of construction work, be sure to putit where it was. + Do not use this instrument for no other than given purpose. * When operate this instrument without using this manual or repair it by use of 1no other parts than the genuine one, the safety and quality of products could not be guaranteed. When any accident should take place by those irregular method, we cannot assume the responsibilty forit N) RIKEN KEIKI CO,, LTD, 257-6 Aasava Rebasti-bu Tokyo, 174-8744 Japan Phone: Tokyo (03) 3966-1113 Telex: 272 2638 RKNFNE Fax :(03) 3558 9110 Gil E-Mail: intodept@rikenkeiicojp INS—1462. Rev 1.0 In the beginning ttis of our great pleasure to purchase Riken portable HC/O2 gas detector mode! RX-415 this time. This instrument is an explosion-proof type portable gas detector which is designed to measure the presence of crude vapors in an inert gas or in air such as HC gas, vapors and methane gas and 02. This instruction manual is a guide book for operation of Riken portable HC/O2 gas detector model RX-415. Itis kindly requested to read and understand this content by experienced users as well as beginners. The following headline shall be shown to carry out the safety and effective ‘work in this instruction manual. A Danger This means that it gives the serious harm to the human life, body or material directly such as touching high voltage. A. Warning This means that it gives the serious harm to the human body or material if do not perform the operation according to the instruction manual. A Caution This means that it gives the slight harm to the human body or material if do not perform the operation according to the instruction manual. * Note ‘This means the advice in the operation. Model RX-415 consists of two type according to the kind of gases below ; ForHC gas use: — Model RX-415 (TYPE HC) HC — :0-100%LEL/0-100vol% 02 — :0-25vol% For CH4 gas use: — Model RX-415 (TYPE CH4) CH4 :0-100%LEL/0-100vol% 02 — :0-25vole% INS— 1462. Rev 1.0 Contents Name of each part: +--+ ++ ++++2 55> 2. Operation Preparation * * 5 up procedure 7 ‘Check of flow monitors 8 Zero adjustment 8 M wement 9 Stop of pump operation * + + u 2-7. Measurement completion + + 2 3. Alarm function 31. Kind ofalarm and 13, 3-2. Counterme: M 4. 4 4 4 4 4 1-6. ement of parts * 4-7 ind treatment when not to use fora log time * 23, 5. Scrap of instrument: + +--+ +++ +++++5 24 6. Tyouble-shooting: - 7. Caution in operation: -------++++++> 26 8. Definition of words: -----++++++++++ a 9. Specifications 9-1. Specifications: 28 9— 2. Accessories 30 1 0. Detection principle: ---++++++++++- sl INS— 1462 Rev 1.0 == 1. Name ofeach part \ (a) ey eT) ada een Utd Oo Orrin b or i} INS 1D) Power/Enter switch This is used for the confirmation of power ON, OFF/input. PUMP/(+) switch This is used for pump Switch ON/OFF and to increase the input value. D ZERO) switch This is used for zero adjustment and decrease the input value @ PEAK switch This is used when desired to show the peak value. BATT/ESC switch This is used when desired to show the battery voltage and cancel the input. @ Gas outlet This is the outlet to exhaust sample gas out. © Calibration gas name plate This shows the calibration gas name. 8) Display unit (LCD display with back light) This displays gas concentration. ® Alarm lamp This flickers and lights on at trouble alarm time. rt Photo sensor window This is for automatic back-lights of display unit by detecting that it gets dark around. @® Gas inlet This is a measuring gas inlet. 1 Carrying case 1 Junction tube (20m) Gas sampling relay hose (29m) + Gas sampling hose (1m) 18 Filter tube with flowmonitor 1462 Rev 1.0 INS—1462 Rev 1.0 2. Operation Check item before operation Instrument : + Check that there is no damage on the display unit. Filter tube with flow monitor : ~ Check the dirt of cotton and when it gets dirty, replace the cotton with new one. (See 5-3) When the water drops are deposited, drain it out. + Check that there is no crack or damage. + Check that there is no looseness on the nipple mounting, Gas sampling hose : * Check that there is no break or twist of it. 2—1. Preparation (a) Mount the battery into instrument. (See 5-1) (2) Putthe instrument into the carrying case. (3) Connect the instrument (gas inlet) the junction tube, filter tube with flowmonitor and gas sampling hose with instrument in tum. ‘As there are two types of head hoses for this instrument, use it according to the each environment. Standard specification Gas sampling relay hose (30m) + Sampling hose Bar type (1m) Optional specification Gas sampling relay hose (30m) + Sampling hose Floating type (1m) (C#Gas sampling relay hose and sampling hose (Bar type/Float type) is optional accessories) + Connection between gas sampling relay hose and model RX-415, By holding knurling part with fingers, pull itto the arrow mark, => Plug in to the arrow mark ~~ with its condition. Release the fingers holding the knurling part and press in. Then, locked after ticking sound. Knurling part Junction tube INS 1462 Rev 1.0 Connection between gas sampling relay hose and sampling hose 3. By holding the socket of gas sampling relay hose and the plug of sampling hose by fingers and plug in to the arrow mark untilit gets a ticking sound. Sampling hose = SS Gas sampling relay hose A Warning ~ As this is used in dangerous zone, be sure to use it with carrying case. A Caution + Be sure to plug in the gas sampling hose and junction tube. tf not surely connected, the accurate measurement cannot be carted out. * Be sure to mount the fitter tube with flowmonitor. Hfmeasure without fier, it will be a cause of trouble by sucking dust, water andoil etc. INS= 1462 Rev 1.0 2-2. Start-up procedure Hold pressing power switch for 5 seconds and the power will tun on. Via battery check, filter probe connection check and sensor connection check, the gas detection will start. The sequence performance until the gas detection starts is as follows : Hold pressing power switch for 5 seconds + 100, Ovol®% 25. Atpump comectontai. | * Note Beet ea At power on, check that BATT. :E —-—1—— F_] Atbattery power shortage. | the buzzer and pump prox. 5 seo. TH+ sound PREPARATION prox. 5sec. PROBE ILTER OK? Afier checking tuberfter, press [ENTER]. ‘ SENSOR CHECK ‘Atsensor connection fa prox. 5 sec. ~___+@ SENSOR CHECK OK prox. 5sec._t WARMING UP 30sec 30 sec. T Countdown STAND BY OK prox. 5sec. 4 0. 0 EI Detection starts. D Display, performance at pump connection failure. (See 3.) FALL PUMP 3 ton, Buzzer: Continuous) ght 2 Display, performance at power voltage shortage. (See 3. and 5-1) REPLACE BATTERY | (amp:Lighton, Buzzer: Continuous) ® Display, performance at sensor connection failure. (See 3.) In case of HC sensor connection failure FAIL SENSOR HC (Lamp : Lighton, Buzzer: Continuous) In case of 02 sensor connection failure FAIL SOR 02 (Lamp: Lighton, Buzzer: Continuous) Incase of HC sensor/O2 sensor connection failure FAIL SENSOR (Lamp : Lighton, Buzzer: Continuous) INS= 1462 Rev 1.0 3. Check of flowmonitor When tum on power, the pump starts working. Check that it works properly by the fiowmonitor (float) of fiter tube with flowmonitor. Float | ey Lijit a4 When sucking property (Can see the float) = Be Not sucking properly (Can see the float) 2 24. Zero adjustment Make zero adjustment by removing the gas sampling hose. After the detection starts, see the flow monitor and check that the air is sucked properly. Then, check that the reading gets stable and make zero adjustment by sucking the fresh air into instrument. ‘The operation procedure is shown below. 0. 0% EL 20. 9% ] (Gasdisplay) HOLD 7 Hold pressing [7 ERG for approx 3 sec. APPLY FRESH ATR] Afterchecking that fresh airis sucked into instrument 4 and then, press [ENTER] switch. ADJUSTING ZERO Zero calibration failure L_ r Approx. 5 sec. ZERO _SE Approx. 5 sec. 0. 09 (Gas display)

You might also like