You are on page 1of 2

Load and Resistance Factor Design (LRFD) method

1 1.4DL

2 1.2DL + 1.6LL + 0.5RL

3 1.2DL + 1.6RL + 0.5LL

4 1.2DL + 1.6RL + 0.8(WX +)

5 1.2DL + 1.6RL + 0.8(WX -)

6 1.2DL + 1.6RL + 0.8(WZ +)

7 1.2DL + 1.6RL + 0.8(WZ -)

8 1.2DL + 1.3(WX +) + 0.5LL + 0.5RL

9 1.2DL + 1.3(WX -) + 0.5LL + 0.5RL

10 1.2DL + 1.3(WZ +) + 0.5LL + 0.5RL

11 1.2DL + 1.3(WZ -) + 0.5LL + 0.5RL

12 1.2DL + 1.5(EX +) + 0.5LL

13 1.2DL + 1.5(EX -) + 0.5LL

14 1.2DL + 1.5(EZ +) + 0.5LL

15 1.2DL + 1.5(EZ -) + 0.5LL

16 0.9DL + 1.3(WX +)

17 0.9DL + 1.3(WX -)

18 0.9DL + 1.3(WZ +)

19 0.9DL + 1.3(WZ -)

20 0.9DL + 1.5(EX +)

21 0.9DL + 1.5(EX -)

22 0.9DL + 1.5(EZ +)

23 0.9DL + 1.5(EZ -)
ALLOWABLE STRESS DESIGN METHOD

1. D
2. D+L
3. D + S (X)
4. D + WX+
5. D + WX-
6. D + WZ+
7. D + WZ-
8. D + EX+
9. D + EX-
10. D + EZ+
11. D + EZ-
12. 0.9D + (W or E) (X)
13. D + (H or F) (X)
14. D + L + (H or F) (X)
15. D + S + L (X)
16. D + S + (W or E) (X)
17. D + L + WX+
18. D + L + WX-
19. D + L + (WZ+)
20. D + L + (WZ-)
21. D + L + (EX+)
22. D + L + (EX-)
23. D + L + (EZ+)
24. D + L + (EZ-)
25. D + L + (H or F) + (W or E) (X)
26. D + S + L + (H or F) + (W or E) (X)