You are on page 1of 1
Copyright 2918 National Fire Protection Association (NFPA) Ukerised. by agreamerr. for wvidual 208 dowrvoad on 10/26/2018 te Tennaurx indonesia Pt for designated user Eddy Purwanto, No ceher reproduction or ‘aronsion very om put tens nto eso &/ NEPA. Pa ren ot ep nareed io, conte onthe rss INSTALLATION OF SPRINKLER SYSTEMS ‘Table 17.4.2.1(a) Maximum Distance Between Hangers (ftin.) ‘Nominal Pipe Size (in.) % 1 % Wm 2 % 8 % 4 5 6 8 Steel pipe except threaded lightwall | NA 120 120 150 150 150 150 150 150 150 150 ‘Threaded lighowall steel pipe NA 120 120 120 120 120 120° NA NA NA NA Copper tube 80 80 100 100 120 120 120 150 150 150 150. eve 56 60 66 70 8D 99 100 NA NA NA NA Dactileiron pipe NANA NA NANA NA 150 NA 150 NA. 150. ‘NA Not applicable ‘Table 17.4.2.1(b) Maximum Distance Between Hangers (m) Nominal Pipe Size (mam) 2 2 = +4 50 68 80 90 100-425 ~«150~—-20 Steel pipe except threaded ighwall | NA 37 37 46 46 46 46 46 46 4646 ‘Threaded lightwall steel pipe NA 370 370 37 37 37 37 NA NA NANA Copper tube 24 24 380 BOT T8746 46 45 46 eve L718 20 21 24 27 30 NA NA NANA Dactleiron pipe NANA NANA NA _NA_46 NA, NA 46 46 NA; Not applicable, 17.4.34¢ Unsupported Lengths 1744.1. For steel pipe, the unsupported horizontal length between the end sprinkler and the last hanger on the line shall not be greater than 36 in, (900 mm) for 1 in, (25 mm) pipe, 48 in. (1.2 m) for 1% in. (32 mm) pipe, and 60 in. (1500 m) for UGin, (40 mm) or larger pipe. 1743.42 For copper tube, the unsupported horizontal length between the end sprinkler and the last hanger on the line shall not be greater than 18 in. (450. mm) for I in (25 mm) pipe, 24 in. (600 mm) for 1% in. (82 mm) pipe, and. 30 in. (750 mm) for 1% in. (40 mm) or larger pipe. 17343 Where the limits of 17.4341 and 174342 are ‘exceeded, the pipe shall be extended beyond the end sprinkler and shall be supported by an additional hanger. 1743.44 Unsupported Length with Maximum Pressure Exceeding 100 pst (6.9 bar) and Branch Line Above Ceiling ‘Supplying Sprinklers in Pendent Position Below Ceiling. 174344. Where the maximum static or flowing pressure, whichever is greater at the sprinkler, applied other than through the fire department connection, exceeds 100 psi (6.9 bar) and a branch line above a ceiling supplies sprinklers in a pendent position below the ceiling, the hanger assembly supporting the pipe supplying an end sprinkler in a pendent position shall be of a type that restrains upward movement of the pipe, 1743.44.2 The unsupported length between the end sprin- kler in a pendent position or drop nipple and the last hanger fon the branch line shall not be greater than 12 in, (300 mm) for steel pipe or 6 in. (150 mm) for copper pipe. I7ASAA3 When the limit of 17.43.4429 is exceeded, the pipe shall be extended beyond the end sprinkler and suppor ted by an additional hanger 2019 Eaton ITASAAA Unless flexible hose fittings in accordance with 174133.1 and ceilings in accordance with 17.41.8322 are used, the hanger closest to the sprinkler shall be of a type that restrans the pipe from upward movement, 17.4.8.5* Unsupported Armover Length. I7A3.5.1 The cumulative horizontal length of an unsuppor- ted armover to 2 sprinkler, sprinkler drop, or sprig shall not exceed 24 in, (600 mm) for steel pipe or 12 in. (300 mm) for capper tube, 17.43.5.2° Unsupported Armover Length with Maximum Pressure Exceeding 100 psi (6.9 bar) and Branch Line Above Ceiling Supplying Sprinklers in Pendent Position Below Ceil: ing. 1743.5.2.1 Where the maximum static or flowing pressure, whichever is greater at the sprinkler, applied other than trough the fire deparument connection, exceeds 100 psi (6.9 bar) and a branch line above a ceiling supplies sprinklers in a pendent position below the ceiling, the cumulative horizontal length of an unsupported armoxer to a sprinkler or sprinkler drop shall not exceed 12 in, (300 mm) for steel pipe and 6 in, (150 mam) for copper tube. 1743.5.22 Unless flexible sprinkler hose fitings in accord ance with 17.4.1.3.3.1 are used, the hanger closest to the sprit ler shall be of a type that resirains upward movement of the pipe. 174.3.5.2.3 Where the armover exceeds the maximum ansup- ported length of 17.4.3.52.1, a hanger shal be installed so that the distance from the end sprinkler or drop nipple to the hhanger is not greater than 12 in, (300 mm) for steel oF 6 in. (150 mm) for copper, or the pipe shall be extended beyond, the end sprinkler and shall be supported by an additional hanger, 174.3.6* Wall mounted sidewall sprinklers shall be restrained, to prevent movement.

You might also like