Professional Documents
Culture Documents
Research Article
Experimental Investigation of the Corrosion Behavior of
Friction Stir Welded AZ61A Magnesium Alloy Welds under Salt
Spray Corrosion Test and Galvanic Corrosion Test Using
Response Surface Methodology
Copyright © 2013 A. Dhanapal et al. This is an open access article distributed under the Creative Commons Attribution License,
which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Extruded Mg alloy plates of 6 mm thick of AZ61A grade were butt welded using advanced welding process and friction stir welding
(FSW) processes. The specimens were exposed to salt spray conditions and immersion conditions to characterize their corrosion
rates on the effect of pH value, chloride ion concentration, and corrosion time. In addition, an attempt was made to develop an
empirical relationship to predict the corrosion rate of FSW welds in salt spray corrosion test and galvanic corrosion test using
design of experiments. The corrosion morphology and the pit morphology were analyzed by optical microscopy, and the corrosion
products were examined using scanning electron microscope and X-ray diffraction analysis. From this research work, it is found
that, in both corrosion tests, the corrosion rate decreases with the increase in pH value, the decrease in chloride ion concentration,
and a higher corrosion time. The results show the usage of the magnesium alloy for best environments and suitable applications
from the aforementioned conditions. Also, it is found that AZ61A magnesium alloy welds possess low-corrosion rate and higher-
corrosion resistance in the galvanic corrosion test than in the salt spray corrosion test.
Rotational Welding speed Axial force Tool shoulder diameter Pin diameter Pin length
Pin profile
speed (rpm) (mm/min) (kN) (mm) (mm) (mm)
Left hand thread
1000 75 3 18 6 5
of 1 mm pitch
Levels
S. no. Factor Unit Notation
−1.682 −1 0 +1 +1.682
1 pH value 𝑃 3 4.62 7 9.38 11
2 Corrosion time Hours (h) 𝑇 1 2.62 5 7.38 9
3 Cl− concentration Mole (M) 𝐶 0.2 0.36 0.6 0.84 1
Coded values Actual values Corrosion rate (salt Corrosion rate (galvanic
EX. no.
Time Conc. spray tests) (mm/yr) corrosion tests) (mm/yr)
pH Time Conc. pH
(𝑇) (𝐶)
(𝑃) (𝑇) (𝐶) (𝑃)
(hour) (Mole)
1 −1 −1 −1 4.62 2.62 0.36 14.62 (0.11) 0.0397 (0.16)
2 +1 −1 −1 9.38 2.62 0.36 10.23 (0.56) 0.0254 (0.13)
3 −1 +1 −1 4.62 7.38 0.36 11.89 (0.21) 0.0340 (0.20)
4 +1 +1 −1 9.38 7.38 0.36 8.99 (0.18) 0.0111 (0.18)
5 −1 −1 +1 4.62 2.62 0.84 15.82 (0.16) 0.0456 (0.14)
6 +1 −1 +1 9.38 2.62 0.84 11.31 (0.1) 0.0425 (0.1)
7 −1 +1 +1 4.62 7.38 0.84 12.92 (0.26) 0.0519 (0.52)
8 +1 +1 +1 9.38 7.38 0.84 10.75 (0.05) 0.0376 (0.05)
9 −1.682 0 0 3 5 0.60 17.96 (0.26) 0.0612 (0.08)
10 +1.682 0 0 11 5 0.60 6.88 (0.41) 0.0267 (0.11)
11 0 −1.682 0 7 1 0.60 11.23 (0.56) 0.0598 (0.07)
12 0 +1.682 0 7 9 0.60 8.51 (0.42) 0.0282 (0.11)
13 0 0 −1.682 7 5 0.20 6.66 (0.23) 0.0184 (0.05)
14 0 0 +1.682 7 5 1 15.28 (0.4) 0.0534 (0.08)
15 0 0 0 7 5 0.60 9.89 (0.36) 0.0432 (0.03)
16 0 0 0 7 5 0.60 8.56 (0.02) 0.0365 (0.02)
17 0 0 0 7 5 0.60 9.79 (0.03) 0.0370 (0.21)
18 0 0 0 7 5 0.60 9.97 (0.05) 0.0377 (0.24)
19 0 0 0 7 5 0.60 8.93 (0.04) 0.0379 (0.38)
20 0 0 0 7 5 0.60 9.62 (0.09) 0.0381 (0.12)
The values presented in brackets are the standard deviation.
where 𝑋𝑖 is the required code values of a variable 𝑋, and 𝑋 deep, and 5 wide). The samples under test were inserted into
is any values of the variable from 𝑋min to 𝑋max ; 𝑋min is the the chamber, following which the salt-containing solution
lower level of the variable, and 𝑋max is the upper level of the was sprayed as a very fine fog mist over the samples. NaCl
variable. in tapped water was pumped from a reservoir to spray
nozzles. The solution was mixed with humidified compressed
air at the nozzle, and this compressed air and atomized
2.5. Salt Spray Corrosion Test (Recording the Response). the NaCl solution into a fog at the nozzle. Heaters were
Solutions of NaCl with concentrations of 0.2 M, 0.361 M, maintained at 35∘ C cabinet temperature. Within the chamber,
0.6 M, 0.838 M, and 1 M were prepared. The pH values of the the samples were rotated frequently so that all samples were
solutions were maintained as pH 3, pH 4.619, pH 7, pH 9.38, exposed uniformly to the salt spray mist. Since the spray was
and pH 11 with concentrated HCl and NaOH, respectively. continuous, the samples were continuously wet and therefore,
The pH value was measured using a digital pH meter. The uniformly subjected to corrosion. The corrosion rate of the
test method consists of exposing the specimens in a salt spray friction stir welded AZ61A alloy specimen was estimated by
chamber as per ASTM B 117 standards and evaluating the weight loss measurement. The original weight (𝑤𝑜 ) of the
corrosion tested specimen with the method as per ASTM specimen was recorded, and then the specimen was sprayed
G1-03. Basically, the salt spray test procedure involves the with the solution of NaCl for different spraying times of
spraying of a salt solution onto the samples being tested. This 1, 2.62, 5, 7.38, and 9 hours. The corrosion products were
was done inside a temperature controlled chamber. The glass removed by immersing the specimens for one minute in a
racks were contained in the salt fog chamber (3 high, 3 solution prepared by using 50 gm chromium trioxide (CrO3 ),
International Journal of Metals 5
base metal and 𝑖corr (B) for AZ61A friction stir welds. When
14.00 equal areas of AZ61A Mg base metal and AZ61A friction
stir welds were coupled, the resultant mixed potential of the
12.00 system 𝐸corr (AB) was at the intersection where the total
oxidation rate equals the total reduction rate. The rate of
oxidation of the individual coupled metals was such that the
10.00 base metal corroded at a reduced rate 𝑖corr (A), and AZ61A
friction stir welds corroded at an increased rate 𝐼corr (B).
8.00 Hence, the AZ61A friction stir weld acts as an anode, and
AZ61A base alloy acts as a cathode. Half-cell reactions were
carried out constituting a single cell. Thus, the current 𝑖corr
6.00 (AB) was the galvanic current which can be measured by a
zero resistance ammeter (ZRA). Free corrosion potential of
8.00 10.00 12.00 14.00 16.00 18.00 both metals was found individually and from the potential
Experimental corrosion rate (mm/yr) difference; FSW AZ61A magnesium alloy was considered to
be an anode, because of its more negative potential than
Figure 5: Correlation graph for response (galvanic corrosion test).
AZ61 base alloy, where the latter was the cathode. Corrosion
current values may be obtained from the ZRA measurements.
The corrosion rate can be calculated using Faraday’s Law in
2.5 gm silver nitrate (AgNO3 ), and 5 gm barium nitrate terms of penetration rates as follows:
(Ba(NO3 )2 ) in 250 mL distilled water. Finally, the specimens 𝐾 × 𝐼corr × EW
were washed with distilled water, dried, and weighed again corrosion rate (mm/yr) = , (4)
𝜌
to obtain the final weight (𝑤1 ). The weight loss (𝑤) can be
measured using the following relation: where 𝐾 is corrosion constant (𝐾 is 0.00327 if corrosion
rate in (mm/yr)), 𝐼corr is current density in mA/cm2 , EW is
equivalent weight of the alloy, and 𝜌 is density of the FSW
𝑤 = (𝑤𝑜 − 𝑤1 ) , (2) AZ61A alloy (1.72 gm/cm3 ).
where 𝑤 is weight loss in grams, 𝑤𝑜 is original weight before 2.7. Metallography. Microstructural analysis of the corroded
test in grams, and 𝑤1 is final weight after test in grams. specimens was carried out using a light optical microscope
6 International Journal of Metals
0.06
19
0.055
17
15 0.05
13 0.45
11 0.04
0.2 0.4 0.6 0.8 1.0 0.2 0.4 0.6 0.8 1.0
Chloride ion concentration (M) Chloride ion concentration (M)
(a) (b)
23 Exposure time = 5 h 0.07 Immersion time = 5 h
21
0.06
Corrosion rate (mm/yr)
Corrosion rate (mm/yr)
19
17 0.05
15 0.04
13
0.03
11
9 0.02
0.2 0.4 0.6 0.8 1.0 0.2 0.4 0.6 0.8 1.0
Chloride ion concentration (M) Chloride ion concentration (M)
(c) (d)
21 Exposure time = 9 h 0.06 Immersion time = 9 h
19
0.05
Corrosion rate (mm/yr)
17
0.04
15
0.03
13
0.02
11
9 0.01
7 0
0.2 0.4 0.6 0.8 1.0 0.2 0.4 0.6 0.8 1.0
Chloride ion concentration (M) Chloride ion concentration (M)
pH = 3 pH = 3
pH = 7 pH = 7
pH = 11 pH = 11
(e) (f)
17.96
20
18
+𝑏13 (𝑃𝐶) + 𝑏23 (𝑇𝐶) } ,
16
Corrosion rate (mm/yr)
14 (7)
12
where 𝑏0 is the average of responses (corrosion rate), and
9.89
6.12 ×10−2
10 𝑏1 , 𝑏2 , 𝑏3 . . . 𝑏11 , 𝑏12 , 𝑏13 . . . 𝑏22 , 𝑏23 , 𝑏33 are the coefficients that
4.32 ×10−2
6.88
8 depend on their respective main and interaction factors,
2.67 ×10−2
6 which are calculated using the expression given as follows:
4
∑ (𝑋𝑖 , 𝑌𝑖 )
2 𝐵𝑖 = , (8)
𝑛
0
pH 3 pH 7 pH 11
where “𝐼” varies from 1 to 𝑛, in which 𝑋𝑖 is the corresponding
coded value of a factor, 𝑌𝑖 is the corresponding response
Salt spray corrosion test output value (corrosion rate) obtained from the experiment,
Galvanic corrosion test and “𝑛” is the total number of combinations considered. All
Figure 7: Comparative estimation of corrosion rate with respect to the coefficients were obtained applying central composite
pH value. rotatable design matrix including the Design Expert sta-
tistical software package. After determining the significant
coefficients (at 95% confidence level), the final relationship
(Union Optics, Japan; model: Versamet-3) incorporated with was developed including only these coefficients. The final
an image analyzing software (Clemex-vision). The exposed empirical relationship obtained by the above procedure to
specimen surface was prepared for the microexamination in estimate the corrosion rate of friction stir welds of AZ61A
the “as polished” conditions. The corrosion test specimens magnesium alloy is given as follows.
were polished in disc-polishing machine with minor polish- Salt spray corrosion test,
ing, and the surface was observed at 200x magnification. The
corrosion products were analyzed by SEM-EDX and XRD corrosion rate = {9.48 − 1.89 (𝑃) − 0.88 (𝑇) + 0.82 (𝐶)
analysis. (9)
+1.60 (𝑃2 ) + 1.27 (𝐶2 )} mm/yr;
3. Developing an Empirical Relationship Galvanic corrosion test,
The response surface methodology (RSM) approach was corrosion rate = {0.056 − 7.33 × 10−3 (𝑃)
adopted in this study because of its following advantages:
(1) the ability to evaluate the effects of interactions between + 2.75 × 10−3 (𝑇) + 0.016 (𝐶)
tested parameters and (2) the benefit of limiting the number
of actual experiments to be carried out, in comparison − 4.25 × 10−3 (𝑃𝑇) + 4.26 × 10−3 (𝑃𝐶)
to a classical approach for the same number of estimated
parameters [17–20]. In the present investigation, to correlate + 4.6 × 10−3 (𝑇𝐶)
the potentiodynamic polarization test parameters and the − 3.74 × 10−4 (𝑇2 )} mm/yr.
corrosion rate of AZ61A welds, a second-order quadratic
(10)
model was developed. The response (corrosion rate of AZ61A
welds) is a function of pH values (𝑃), exposure time (𝑇), and
chloride ion concentration (𝐶), and it could be expressed as 3.1. Checking the Adequacy of the Model Salt Spray Testing.
The Analysis of Variance (ANOVA) technique was used
corrosion rate = 𝑓 (𝑃, 𝑇, 𝐶) . (5) to find the significant main and interaction factors. The
In order to study the combined effects of these parameters, results of the second-order response surface model fitting
experiments were conducted at different combinations using in the form of Analysis of Variance (ANOVA) are given
statistically designed experiments. The empirical relationship in Table 5. The determination coefficient (𝑟2 ) indicated the
must include the main and interaction effects of all factors goodness of fit for the model. The model 𝐹 value of 31.30
and hence the selected polynomials are expressed as follows: implies the model is significant. There is only a 0.01%
chance that a “model 𝐹 value” this large could occur due
𝑌 = 𝑏𝑜 + ∑ 𝑏𝑖 𝑥𝑖 + ∑ 𝑏𝑖𝑖 𝑥𝑖2 + ∑ 𝑏𝑖𝑗 𝑥𝑖 𝑥𝑗 . (6) to noise. Values of “Prob > 𝐹” less than 0.0500 indicate
that model terms are significant. In this case 𝑃, 𝑇, 𝐶,
For three factors, the selected polynomial could be expressed
as 𝑃2 , and 𝐶2 are significant model terms. Values greater than
0.1000 indicate that the model terms are not significant.
corrosion rate = {𝑏0 + 𝑏1 (𝑃) + 𝑏2 (𝑇) + 𝑏3 (𝐶) If there are many insignificant model terms (not count-
ing those required to support hierarchy), model reduction
+ 𝑏11 (𝑃2 ) + 𝑏22 (𝑇2 ) may improve the model. The “lack of fit 𝐹 value” of 1.69
8 International Journal of Metals
20 𝜇m 20 𝜇m
pH 3 pH 3
(a) (b)
20 𝜇m 20 𝜇m
pH 7 pH 7
(c) (d)
20 𝜇m 20 𝜇m
pH 11 pH 11
(e) (f)
implies that the lack of fit is not significant relative to the 3.2. Checking the Adequacy of the Model Galvanic Corrosion
pure error. There is a 28.93% chance that a “lack of fit 𝐹 Testing. The Analysis of Variance (ANOVA) technique was
value” this large could occur due to noise. Nonsignificant used to find the significant main and interaction factors. The
lack of fit is good. The “Pred R-Squared” of 0.8176 is in results of second-order response surface model fitting in the
reasonable agreement with the “Adj 𝑅-Squared” of 0.9349. form of Analysis of Variance (ANOVA) are given in Table 6.
“Adeq Precision” measures the signal to noise ratio. 𝑃 ratio The determination coefficient (𝑟2 ) indicated the goodness of
greater than 4 is desirable. Our ratio of 19.440 indicates an fit for the model. The model 𝐹 value of 27.66 implies the model
adequate signal. All of this indicated an excellent suitability of is significant. There is only a 0.01% chance that a “model 𝐹
the regression model. Each of the observed values compared value” this large could occur due to noise. Values of “Prob >
with the experimental values are shown in Figure 4. 𝐹” less than 0.0500 indicate that model terms are significant.
International Journal of Metals 9
17 0.04
16 0.03
15 0.02
0 2 4 6 8 10 0 2 4 6 8 10
Exposure time (h) Immersion time (h)
(a) (b)
18 0.07
17 pH = 7 pH = 7
0.06
16
Corrosion rate (mm/yr)
Corrosion rate (mm/yr)
15 0.05
14
0.04
13
12 0.03
11
0.02
10
9 0.01
0 2 4 6 8 10 0 2 4 6 8 10
Exposure time (h) Immersion time (h)
(c) (d)
16 0.07
pH = 11 pH = 11
15 0.06
14
Corrosion rate (mm/yr)
Corrosion rate (mm/yr)
0.05
13
12 0.04
11 0.03
10
0.02
9
0.01
8
7 0
0 2 4 6 8 10 0 2 4 6 8 10
Exposure time (h) Immersion time (h)
Conc. = 0.2 M Conc. = 0.2 M
Conc. = 0.6 M Conc. = 0.6 M
Conc. = 1 M Conc. = 1 M
(e) (f)
In this case 𝑃, 𝑇, 𝐶, 𝑇𝐶, and 𝑇2 are significant model terms. 4. Results and Discussion
Values greater than 0.1000 indicate that the model terms were
not significant. If there are many insignificant model terms 4.1. Effect of pH on Corrosion Rate. Figure 6 shows the
(not counting those required to support hierarchy), model graph representing the effect of pH on corrosion rate during
reduction may improve the model. salt spray testing and galvanic corrosion testing. For both
The “lack of fit 𝐹 value” of 2.39 implies that the lack of corrosion tests, the graph shows clearly that the corrosion rate
fit was not significant relative to the pure error. There was an decreased with the increase in pH value. At every chloride
18.08% chance that a “lack of fit 𝐹 value” this large could occur ion concentration and immersion time, the FS welds usually
due to noise. Nonsignificant lack of fit is good. The “Pred 𝑅- exhibited a decrease in corrosion rate with increase in pH.
Squared” of 0.7763 is in reasonable agreement with the “Adj In neutral pH, the corrosion rate remained approximately
𝑅-Squared” of 0.9266. “Adeq Precision” measures the signal constant, and comparatively low corrosion rate was observed
to noise ratio. 𝑃 ratio greater than 4 is desirable. Our ratio in alkaline solution. It was seen that the influence of pH
of 21.393 indicates an adequate signal. Each of the observed was more at higher concentration as compared to lower
values compared with the experimental values are shown in concentration in neutral and alkaline solutions.
Figure 5, and it had a good agreement between the observed On comparing the corrosion rate of both, the corrosion
values and the experimental values. tested specimen was represented as bar diagram in Figure 7.
International Journal of Metals 11
15.28
16 with the increase in chloride ion concentration, the rising rate
of corrosion rate decreased. The increase in corrosion rate
Corrosion rate (mm/yr)
14
12
with increasing chloride ion concentration may be attributed
9.89
to the participation of chloride ions in the dissolution
5.34 ×10−2
10
reaction for both corrosion tests [24]. Figure 10 represents
4.32 ×10−2
6.66
20 𝜇m 20 𝜇m
Chloride ion concentration = 0.2 M Chloride ion concentration = 0.2 M
(a) (b)
20 𝜇m 20 𝜇m
Chloride ion concentration = 0.6 M Chloride ion concentration = 0.6 M
(c) (d)
20 𝜇m 20 𝜇m
Chloride ion concentration = 1 M Chloride ion concentration = 1 M
(e) (f)
immersion time, which tends to increase the concentration 2H2 O + 2e− → 2OH− + H2 (13)
of OH− ions strengthening the surface from causing further
corrosion. The strength of the electrolyte reduces from acidity Mg2+ + 2OH− → Mg(OH)2 (14)
to alkalinity with the increase of time.
This is attributed to corrosion occurs over an increasing Figure 13 shows the comparison of the corrosion rate
fraction on the surface leaving the white flakes, which is obtained during the salt spray and galvanic corrosion test.
the insoluble corrosion product [24]. The insoluble corrosion With the increase of corrosion time the corrosion rate
products on the surface of the alloy could slow down the decreases for both specimens. It proved that the protective
corrosion rate: layer made a predominant role to strike against corrosion
with the increment of time. The corrosion rate seems higher
Mg → Mg2+ + 2e− (12) in salt spray corrosion test due to the spraying effect, while
International Journal of Metals 13
13 0.03
0.025
11 0.02
9 0.015
0.01
7
0.005
5 0
4 6 8 10 12 2 4 6 8 10 12
pH pH
(a) (b)
20 Chloride ion concentration = 0.6 M 0.07 Chloride ion concentration = 0.6 M
19
18 0.06
Corrosion rate (mm/yr)
Corrosion rate (mm/yr)
17
16 0.05
15
14 0.04
13
12 0.03
11
10 0.02
4 6 8 10 12 2 4 6 8 10 12
pH pH
(c) (d)
22 0.14
Chloride ion concentration = 1 M Chloride ion concentration = 1 M
0.13
20
0.12
Corrosion rate (mm/yr)
Corrosion rate (mm/yr)
18
0.11
16 0.1
14 0.09
0.08
12
0.07
10
0.06
8 0.05
4 6 8 10 12 2 4 6 8 10 12
pH pH
Time = 1 h Time = 1 h
Time = 5 h Time = 5 h
Time = 9 h Time = 9 h
(e) (f)
11.23
12 in corrosion time, the hydroxide layer formed is the dom-
9.89
inant factor to avoid further corrosion. This is attributed
10 to corrosion occurring over an increasing fraction of the
8.51
Corrosion rate (mm/yr)
5.98 ×10−2
surface, which is the insoluble corrosion product, Mg(OH)2 .
8 Thus, the corrosion rate decreases with the increase of
4.32 ×10−2
corrosion time. It was observed that the corrosion products
2.82 ×10−2
6
were thick and adherent in the specimen that underwent
4 galvanic corrosion test while the specimen that underwent
salt spray test exhibited lamellar corrosion products, which
2 seems higher attack and less protective. This showed higher
corrosion rate in the salt spray test than the galvanic corrosion
0 test.
Time = 1 h Time = 5 h Time = 9 h Figure 16 shows the XRD analysis to predict the compo-
sition of corrosion products and phase in the specimen sub-
Salt spray corrosion test jected to salt spray and galvanic corrosion tests. Figure 16(a)
Galvanic corrosion test shows that the specimen underwent the salt spray corrosion
Figure 13: Comparative estimation of corrosion rate with respect to test; the characteristic peaks originate from the metallic Mg
corrosion time. substrate and the 𝛽 phase. The detected number of peaks
relates to the 𝛽 phase (Mg17 Al12 ) which is higher in its inten-
sities. It symbolizes the hydroxide layer which finds it hard to
in immersed condition, the protective layer formed during form during the salt spray corrosion test due to its spraying
galvanic corrosion was enhanced by the alkalization of the effects. However, Mg(OH)2 and MgO phases are detected
solution. in Figure 16(b), where the specimen underwent the galvanic
Figure 14 shows the effect of corrosion time on pit corrosion test; Mg(OH)2 is the dominant product in the
morphology of the corroded specimen exposed in pH 7 corrosion zone of the anodic specimen that underwent the
with chloride ion concentration of 0.6 M NaCl exposed, galvanic corrosion test. Mg(OH)2 (brucite) has a hexagonal
1 h, 5 h, and 9 h for both salt spray testing and galvanic crystal structure and easily undergoes basal cleavage causing
corrosion testing. The mode of microstructural features was cracking and curling in the film, which could play a major role
comparatively the same during corrosion testing for both in reducing the corrosion behavior and the corrosion rate. It
tests as its corrosion time is taken into account. The FS welded signifies during immersion that the alkalization effect tends
specimens possess refined grain, and quite a lot of 𝛽 particles to strengthen the formation of the hydroxide layer.
were distributed continually along the grain boundary.
In this case, 𝛽 phase particles cannot be easily destroyed 5. Conclusions
and, with the increase of corrosion time, the quantity of 𝛽
phases in the exposed surface would increase and finally (1) A mathematical model has been developed here to
play the role of corrosion barrier [26]. Although there are predict the corrosion rate using salt spray tests and
some grains of 𝛼 phase still being corroded, most of the galvanic corrosion with a 95% confidence level. The
remaining 𝛼 phase grains are protected under the 𝛽 phase corrosion rates obtained were quite different in both
barrier, so the corrosion rate decreased with the increase in tests; it found that, the corrosion rate was much higher
corrosion time. Thus, the corrosion morphology of the alloy in salt spray test than in the galvanic corrosion test.
was predominantly controlled by the 𝛽 phase distribution (2) In this investigation, it was proved from both tests,
[27]. for every pH value; that the FS weld metal exhib-
ited a rise in corrosion rate with decrease in pH
4.4. SEM and XRD Analysis. Figure 15 shows the surface value. In the neutral pH, the corrosion rate remained
texture of the specimens that underwent salt spray corrosion approximately constant in neutral solutions, and a
and galvanic corrosion tests which were observed under comparatively low corrosion rate was observed in
SEM as corrosion time was a factor. Figure 15(a) shows the alkaline solutions.
specimens exposed to 1 hour comprised of more localized
attack. With corrosion time as a factor, the less spraying time (3) Chloride ions were aggressive on magnesium alloy.
tends to attack more locally on the surface, and later, it pen- The adsorption of chloride ions to oxide covered the
etrates to the substrates, causing higher corrosion behavior magnesium surface and transformed Mg(OH)2 to
and corrosion rate. It was redeems to spalling of corrosion easily soluble MgCl2 in salt spray corrosion testing
products. Thus, serious pitting occurred in the surface of the while in galvanic corrosion testing, it readily formed
weldment with less exposure time for both corrosion-tested Mg(OH)2 Cl2 due to the immersion criterion.
specimens. The quantity of corrosion products formed was (4) It resulted in an increase in hydrogen evolution
quite comparably larger in the galvanic corrosion test caused with the increasing corrosion time, which tended to
due to immersion. increase the concentration of OH− ions; thereby, an
Figure 15(b) shows the specimens exposed to 9 hours increasing fraction of the surface was observed, which
composed of more corrosion products. With the increase is the insoluble corrosion products. The insoluble
International Journal of Metals 15
20 𝜇m 20 𝜇m
Corrosion time = 1 h Corrosion time = 1 h
(a) (b)
20 𝜇m 20 𝜇m
Corrosion time = 5 h Corrosion time = 5 h
(c) (d)
20 𝜇m 20 𝜇m
Corrosion time = 9 h Corrosion time = 9 h
(e) (f)
corrosion products on the surface of the alloy could the electrolyte under immersion. The corrosion rate
slow down the corrosion rate. of galvanic couple ranges from 0.03 to 0.06 mm/yr,
which is quite negligible, and shows excellent prop-
(5) In this investigation, it was found that the corrosion erty of corrosion resistant as per corrosion handbooks
rate obtained from the salt spray tests was much and guides. So, the couple were galvanically a good
higher than the rates obtained from the galvanic couple, and they can be suitable for good applications.
corrosion tests. It was due to spraying effect where
stagnation of the solution could not be taken into
account while in galvanic corrosion testing, there is Conflict of Interests
a substantial increase in the pH of the solution during
corrosion reactions due to the migration of ions in The authors declare that there is no conflict of interests.
16 International Journal of Metals
Figure 15: Scanning electron micrograph of corrosion test specimens underwent salt spray corrosion test and galvanic corrosion test.
500
80
400
60
300
Intensity
Intensity
40
200
20
100
0 0
0 20 40 60 80 100 0 20 40 60 80 100
2𝜃 (deg)
2𝜃 (deg)
Mg Mg
Mg(OH)2 Mg(OH)2
Mg17 Al12 Mg17 Al12
(a) (b)
Figure 16: XRD pattern of corrosion test specimens underwent salt spray corrosion test and galvanic corrosion test.
International Journal of Metals 17
Journal of
Metallurgy
BioMed
Research International
Hindawi Publishing Corporation Hindawi Publishing Corporation
http://www.hindawi.com Volume 2014 http://www.hindawi.com Volume 2014
Nanomaterials
Submit your manuscripts at
http://www.hindawi.com
Journal of Journal of
Materials
Hindawi Publishing Corporation
Nanoparticles
Hindawi Publishing Corporation
http://www.hindawi.com Volume 2014 http://www.hindawi.com Volume 2014
Nanomaterials
Journal of
Nanoscience
Hindawi Publishing Corporation
Coatings
Hindawi Publishing Corporation
Crystallography
Hindawi Publishing Corporation
Ceramics
Hindawi Publishing Corporation
Textiles
Hindawi Publishing Corporation
http://www.hindawi.com
http://www.hindawi.com Volume 2014 http://www.hindawi.com Volume 2014 http://www.hindawi.com Volume 2014 http://www.hindawi.com Volume 2014 Volume 2014