Overview
1
Introduction
API 521 - ISO 23251 Definition:
Vessel in the effluent handling system designed to remove and store
liquids.
Function of Flare Knockout Drum:
To separate liquid from gas and hold maximum amount of liquid
relieved in an emergency. KO drum is typically located close to the flare
stack upstream of any liquid seal.
Unit knockout drums:
For process units which possibly release large amount of liquid, it is
desirable to have local KO drums inside the battery limit. This reduces
the sizing requirements for the main flare knockout drum.
Knockout drum can be horizontal or vertical.
2
Design Parameters
3
Design Parameters
6. Typically the relief rates (not rated capacities) used for flare header,
flare tip, and knockout drum design.
7. It is normally not necessary to size local knockout drums for efficient
vapor-liquid separation at maximum flow rate.
8. The economics of the drum design can influence the choice between
horizontal and vertical drums.
● Horizontal drums are more suitable for large liquid capacity and
high vapor flow. They have lower pressure drop than vertical
drums.
● Vertical drums are typically used when the liquid load is low or
limited plot space is available.
4
Design Parameters
9. Nozzle Configurations:
a) Horizontal Drums:
● Vapor entering at one end and exiting at the top of the
opposite end.
● Vapor entering at each end and exiting at the center.
● Vapor entering at the center and exiting at each end of the
drum.
b) Vertical Drums:
● Vapor entering radially and exiting at the top of the drum.
A baffle is required to direct the flow downward.
● Vapor entering tangentially and exiting at the top of the drum.
5
Knockout Drum Sizing
6
Vapor Travel - Liquid Dropout
HV
HL
L HV
TV = N TD =
VV VD
T V : Vapor Residence Time T D : Liquid Dropout Time
L N : KO Drum Nozzle to Nozzle Length H V : Vapor Space Height
V V : Vapor Velocity V D : Liquid Dropout Velocity
7
Horizontal Knockout Drum Sizing
g D (ρ L − ρV )
V D = 1.15
ρV C
VD : Liquid Dropout Velocity
g: Gravitational Constant (9.8 m/s2, 32.2 ft/s2)
D: Particle Diameter
ρL : Liquid Density at Operating Conditions
ρV : Vapor Density at Operating Conditions
C: Drag Coefficient
8
Horizontal Knockout Drum Sizing
Drag Coefficient:
2 (Cte ) ( ρV ) ( D )3 ( ρ L − ρV )
(C ) (Re) =
( µ )2
Re : Reynolds Number
µ: Vapor Viscosity at Operating Conditions
Cte : Constant (0.13 x 108 in Metric and 0.95 x 108 in Imperial Units)
9
API 521 – ISO 23251 Sample Calculation
10
API 521 – ISO 23251 Sample Calculation
Drag Coefficient x Re2 C x Re2= [ 0.95 x 108 x 0.18 x (0.000984)3 x (31 - 0.18) ] / (0.01)2 = 5,021
Dropout Velocity UC= 1.15 * [ 32.2 X 0.000984 x (31 - 0.18) / (0.18 x 1.3) ]0.5 = 2.35 ft/sec
Holdup Cross Sectional Area AH= (31,000 / 31) x (30/60) (ft3) / L (ft)
11
API 521 – ISO 23251 Sample Calculation
AV HH
HT (D)
α
β 1
AH + AS = × [ β − Sin (β ) ] × D 2
8
AH HH
1
AS = × [ α − Sin (α ) ] × D 2
8
AS HS
12
API 521 – ISO 23251 Sample Calculation
Diameter Length Cross Sectional Area Vertical Height Dropout Vapor Minimum
Case No D L AT AS AH AV HT (D) HS + HH HV Time, TD Vel, VV Length, L
13
API 521 Sample calculation
14
API 521 Sample Calculation
15
API 521Sample Calculation
32 Nozzle Centerline to Tangent Nzzl. Centerline to Tan.
33 ft 18.50 ft ft
34 Inlet Nozzle Dia, in: Outlet Nzzle Dia, in:
35 12.00 12.00
36
37 Liq Levels From Bottom ( ft ) Section Vol Residence Time, minute Vapor
38 Space
HHLL (ESD) 4.49 ( ft³ ) Incoming Outgoing (2) Note 3
39 HLL (2nd Pump Starts) 4.69 -29.5 -1.8 -17.7 -2.0
8.0 ft
40 NLL (1st Pump Starts) 4.69 0.0 0.0 0.0 0.0 Add Holdup
41 Slop Level 1.00 500.0 30.0 300.0 33.3 Liq Holdup
42 LLL (Both Pumps Stop) 0.00 66.8 4.0 40.1 4.5 Slop Cap
43 0.0 0.0 0.0 0.0 Dead Vol
44 18.50 ft
45
46 NOTES
47 1. Do NOT link entry cells (cells highlighted blue) to other cells. These cells SHOULD contain a numeric value.
48 2. Residence time for each section based on the capacity of one pump.
49 3. This is the residence time for each section based on the balance of the incoming liquid flow and the outgoing pump-out rate by one pump.
50 Negative numbers (if applicable) mean the pump-out rate is greater than the incoming flow rate.
51
52
53
16
Knockout Drum Spreadsheet - 1
7 Compressibility Factor, Z V --
8 Density, ρ V lb/ft³ 0.180
9 Viscosity, µV cP 0.010
10 Mass Flow Rate, M L lb/hr 31,000
11 Density, ρ L lb/ft³ 31.0
LIQUID
17
Knockout Drum Spreadsheet - 2
16 Vapor Density, ρV lb/ft³ 0.180
17 Volumetric Vapor Rate, Q V ft³/hr 938,889
18 Liquid Holdup Capacity ft³ 500.0
19 Calculated Drum Diameter, D C ft 7.85
20 Calculated Minimum Drum Length (T/T), L C ft 19.11
21 Slop Height from Bottom, H SC ft 0.98
22 Liquid Holdup Height from Bottom (NLL), H NC ft 4.63
23 High Liquid Level Height from Bottom, H LC ft 4.63
24 Liquid Dropout Velocity, V DC ft/sec 2.35
25 Liquid Dropout Time, T DC sec 1.37
26 Vapor Space Height, H VC ft 3.22
27 Vapor Space Cross Sectional Area, A VC ft² 18.7
28 Vapor Velocity, V VC ft/sec 13.95
29 C ( Re ) 2 -- 5,025
30 Drag Coefficient, C C -- 1.298
31 Convergence Absolute Tolerance ft 0.00E+00
18
Knockout Drum Spreadsheet - 3
SELECTED DRUM DIMENSIONS UNIT VALUE
KO Drum Pump(s) Capacity ft³/hr 100.00
Does Second Pump Start at HLL? -- No
Droplet Size for Selected Dimensions, d S micron 303
Selected Drum Diameter, D S ft 8.00
Selected Drum Length (T/T), L S ft 18.50
Slop Height from Bottom, H SS ft 1.00
Liquid Holdup Ht (Normal Level), H NS ft 4.69
High Liquid Level Height, H LS ft 4.69
Liquid Dropout Velocity, V DS ft/sec 2.38
Liquid Dropout Time, T DS sec 1.39
Vapor Space Height, H VS ft 3.31
Vapor Space Cross Sectional Area, A VS ft² 19.6
Vapor Velocity, V VS ft/sec 13.29
C ( Re ) 2 -- 5,180
Drag Coefficient, C S -- 1.284
Iteration Weight -- 2.00
19
Knockout Drum Spreadsheet - 4
32 Nozzle Centerline to Tangent Nzzl. Centerline to Tan.
33 ft 18.50 ft ft
34 Inlet Nozzle Dia, in: Outlet Nzzle Dia, in:
35 12.00 12.00
36
37 Liq Levels From Bottom ( ft ) Section Vol Residence Time, minute Vapor
38 Space
HHLL (ESD) 4.49 ( ft³ ) Incoming Outgoing (2) Note 3
39 HLL (2nd Pump Starts) 4.69 -29.5 -1.8 -17.7 -2.0
8.0 ft
40
NLL (1st Pump Starts) 4.69 0.0 0.0 0.0 0.0 Add Holdup
41 Slop Level 1.00 500.0 30.0 300.0 33.3 Liq Holdup
42 LLL (Both Pumps Stop) 0.00 66.8 4.0 40.1 4.5 Slop Cap
43 0.0 0.0 0.0 0.0 Dead Vol
44 18.50 ft
45
46 NOTES
47 1. Do NOT link entry cells (cells highlighted blue) to other cells. These cells SHOULD contain a numeric value.
48 2. Residence time for each section based on the capacity of one pump.
49 3. This is the residence time for each section based on the balance of the incoming liquid flow and the outgoing pump-out rate by one pump.
50 Negative numbers (if applicable) mean the pump-out rate is greater than the incoming flow rate.
51
52
53
20
Spreadsheet Features UOM
UNITS OF MEASUREMENT
Temperature °F
Pressure psi
Mass Flow Rate lb/hr
Liquid Volumetric Flow Rate ft³/hr
Vapor Volumetric Flow Rate ft³/hr
Density lb/ft³
Dimension ft
Area ft²
Liquid Volume ft³
Velocity ft/sec
Viscosity cP
Nozzle Diameter in
Single Entry TRUE Dual Entry FALSE
21
Spreadsheet Features UOM
22
Spreadsheet Features – UOM
23
Features – Number of Entry Nozzles
Nozzle Diameter in
Single Entry TRUE Dual Entry FALSE
Liq Levels From Bottom ( ft ) Section Vol Residence Time, minute Vapor
Space
HHLL (ESD) 4.49 ( ft³ ) Incoming Outgoing (2) Note 3
HLL (2nd Pump Starts) 4.69 -29.5 -1.8 -17.7 -2.0
8.0 ft
NLL (1st Pump Starts) 4.69 0.0 0.0 0.0 0.0 Add Holdup
LLL (Both Pumps Stop) 0.00 66.8 4.0 40.1 4.5 Slop Cap
18.50 ft
24
Features – Number of Entry Nozzles
Nozzle Diameter in
Single Entry FALSE Dual Entry TRUE
LLL (Both Pumps Stop) 0.00 66.8 4.0 40.1 4.5 Slop Cap
18.50 ft
25
Features – Iterative Calculations
Calculated Values
Entered Data
16 Vapor Density, ρV lb/ft³ 0.180
1 DESCRIPTION UNIT VALUE 17 Volumetric Vapor Rate, Q V ft³/hr 938,889
2 Drum Temperature, t °F 300.0 18 Liquid Holdup Capacity ft³ 500.0
3 Drum Pressure, P bar-g 0.138 19 Calculated Drum Diameter, D C ft 7.85
4 Estimated L/D Ratio, R E -- 2.44 20 Calculated Minimum Drum Length (T/T), L C ft 19.11
5 Mass Flow Rate, M V lb/hr 169,000 Slop Height from Bottom, H SC
21 ft 0.98
6 Molecular Weight, MW V lb/lbmole
VAPOR
12 Maximum Droplet Size, d M micron 300 27 Vapor Space Cross Sectional Area, A VC ft² 18.7
13 Slop Capacity, V S ft³ 66.8 28 Vapor Velocity, V VC ft/sec 13.95
14 Holdup Time, (Slop Level to NLL), T H minute 30 29 C ( Re ) 2 -- 5,025
15 Additional Holdup Volume to HLL, V XL ft³ 0.0 30 Drag Coefficient, C C -- 1.298
31 Convergence Absolute Tolerance ft 0.00E+00
26
Features – Convergence
FLARE KNOCK OUT DRUM PROG NO: JE-103 Converg. Area
Client: JACOBS Prepared By: Date: 05/08/2011 Check Tolerance
Project: API 521 SAMPLE CALCULATION - 1 Checked By: Job No: XXXXX-100 R FALSE 8.96E-05
Subject: FLARE KNOCK OUT DRUM Tag No: V-XXXX E FALSE -6.86E-10
Calc No: XXX-XXXX-XXXXX-000 File No: XXX-XXXX-XXXXX-000 Sheet: 1 of 1 V FALSE -9.89E-10
1 DESCRIPTION UNIT VALUE UNITS OF MEASUREMENT FALSE 9.89E-10
2 Drum Temperature, t °F 300.0 Temperature °F FALSE Converg.
3 Drum Pressure, P psi-g 2.0 Pressure psi FALSE Tolerance
4 Estimated L/D Ratio, R E -- 2.44 Mass Flow Rate lb/hr FALSE 5.56E-09
5 Mass Flow Rate, M V lb/hr 169,000 Liquid Volumetric Flow Rate gpm FALSE 0.00E+00
6 Molecular Weight, MW V lb/lbmole 79.11 Vapor Volumetric Flow Rate ft³/hr FALSE
VAPO R
4.11E-15
7 Compressibility Factor, Z V -- 0.900 Density lb/ft³ FALSE -3.55E-15
8 Density, ρ V lb/ft³ Dimension ft FALSE
9 Viscosity, µV cP 0.010 Area ft² FALSE
10 Mass Flow Rate, M L lb/hr 31,000 Liquid Volume ft³ FALSE
11 Density, ρ L lb/ft³ 31.0 Velocity ft/sec FALSE
L IQ U ID
TRUE 0.00E+00
7 Compressibility Factor, Z V -- Density lb/ft³ TRUE 0.00E+00
8 Density, ρ V lb/ft³ 0.180 Dimension ft TRUE
9 Viscosity, µV cP 0.010 Area ft² TRUE
10 Mass Flow Rate, M L lb/hr 31,000 Liquid Volume ft³ TRUE
11 Density, ρ L lb/ft³ 31.0 Velocity ft/sec TRUE
LIQ U ID
29
Features – Liquid Levels
ft 18.50 ft 0.00 ft
Inlet Nozzles Dia, in:
12.00
Outlet Nzzle Dia, in: 14.00
Liq Levels From Bottom ( ft ) Section Vol Residence Time, minute Vapor
Space
HHLL (ESD) 0.00 ( ft³ ) Incoming Outgoing (2) Note 3
HLL (2nd Pump Starts) 4.69 -566.8 -34.0 -340.1 -37.8
8.0 ft
NLL (1st Pump Starts) 4.69 0.0 0.0 0.0 0.0 Add Holdup
LLL (Both Pumps Stop) 0.00 66.8 4.0 40.1 4.5 Slop Cap
18.50 ft
30
Features – Section Vol., & Resid. Time
ft 18.50 ft 0.00 ft
Inlet Nozzles Dia, in:
12.00
Outlet Nzzle Dia, in: 14.00
Liq Levels From Bottom ( ft ) Section Vol Residence Time, minute Vapor
Space
HHLL (ESD) 0.00 ( ft³ ) Incoming Outgoing (2) Note 3
HLL (2nd Pump Starts) 4.69 -566.8 -34.0 -340.1 -37.8
8.0 ft
NLL (1st Pump Starts) 4.69 0.0 0.0 0.0 0.0 Add Holdup
LLL (Both Pumps Stop) 0.00 66.8 4.0 40.1 4.5 Slop Cap
18.50 ft
31
Features – Effective Drum Length
Nozzle Centerline to Tangent Nzzl. Centerline to Tan.
0.51 ft 17.40 ft 0.59 ft
Inlet Nozzle Dia, in: Outlet Nzzle Dia, in:
12.00 14.00
Liq Levels From Bottom ( ft ) Section Vol Residence Time, minute Vapor
Space
HHLL (ESD) 0.00 ( ft³ ) Incoming Outgoing (2) Note 3
HLL (2nd Pump Starts) 4.69 -566.8 -34.0 -340.1 -37.8
8.0 ft
NLL (1st Pump Starts) 4.69 0.0 0.0 0.0 0.0 Add Holdup
LLL (Both Pumps Stop) 0.00 66.8 4.0 40.1 4.5 Slop Cap
18.50 ft
● Effective Length of the drum is between inlet and outlet nozzle centerlines.
● The distance from the nozzle centerline to head seam must be greater than half
of the nozzle diameter.
32
Features – Cell Comments
33