Wall-based Technology Overview
Power/Data Cable Routing and Access

3 5

Electrical can be configured in any combination of standard 1-P


 ower and cables route vertically within frames
and isolated circuits simply by specifying appropriate and through universal connectors.
receptacles (3+1, 2+2 or 1+3).
2 - L ay-in of cabling in the top channel and base of
Electrical can be later reconfigured to a different combination frames streamlines installation and reconfiguration.
of standard and isolated circuits by simply changing some
receptacles.
1 Electrical feeds and harnesses stay the same, 3-R
 eceptacles and data outlets can be located at the
enabling cost-effective changes with minimal disruption. base, above the base, above and below the work
surface, at standing height, or at shelf height.

4-P
 ower harnesses are modular, nonhanded, and
install easily without tools; two modular connection
points at the end of each power harness allow
branching of power.

5 - Power and cables can be routed horizontally


through openings in the frame every 11 inches.

Z
Wall-based Technology Overview
Power/Data Cable Routing and Access

1 - Cleanly manage cords and power adapters along


underside of surfaces with generously sizes
3 cable managers.
2 - Open shelves in low credenza allow for technology
storage with cord passage to the work surface.
3 - Access power and data outlets on the Canvas wall
above or below surfaces.
4 - Thoughtful cutouts in cable managers allow cords
2 to enter and exit from all sides for easy cord
1 management
5 - ThriveSM Connect power/data support components
can be used for power/data access at the work
surface

Cable Capacity CATEGORIES CATEGORY 6 CATEGORY 6A


3, 5, 5E

FILL FACTOR 40% 60% 40% 60% 40% 60%

powered 11 16 8 12 4 6

4 Base Raceway

non-powered 63 95 49 73 25 37

Frame Vertical
Cable Pass-Thru
(to route cables non-powered 74 110 57 86 29 44
vertically within frame,
include two openings)

Frame Horizontal
Cable Pass-Thru
(to route cables
horizontally from non-powered 158 237 122 183 62 94
frame to frame)

68"h Frame
(five openings)

Top Channel 32 47 24 37 12 19
5

powered 32 47 24 37 12 19
Ceiling Entry,
Connector
non-powered 45 67 35 52 18 27

Z
HERMAN MILLER 8-WIRE WIRING HARNESS

Harness Harness
Top Top
Neutral 2 N2 White / Red Neutral 2 N2 White / Red

Neutral 1 N1 White / Black Neutral 1 N1 White / Black

Isolated Ground G2 Green / Yellow


Isolated Ground G2 Green / Yellow

Common Ground G1 Green


Common Ground G1 Green

Circuit D Hot Circuit D Hot Hd Pink


Hd Pink
Circuit C Hot Hc Blue
Circuit C Hot Hc Blue
Circuit B Hot Hb Red
Circuit B Hot Hb Red
Circuit A Hot Ha Black
Circuit A Hot Ha Black

N H N H N H N H
N H N H N H N H G G G G
G G G G
a b ci d
a b c d

3 general purpose + 1 isolated circuit 2 general purpose + 2 isolated circuits

Harness Harness
Top Top
Neutral 2 N2 White / Red Neutral 2 N2 White / Red
Neutral 1 N1 White / Black Neutral 1 N1 White / Black

Isolated Ground G2 Green / Yellow Isolated Ground G2 Green / Yellow

Common Ground G1 Green Common Ground G1 Green

Circuit D Hot Hd Pink Circuit D Hot Hd Pink

Circuit C Hot Hc Blue Circuit C Hot Hc Blue

Circuit B Hot Hb Red Circuit B Hot Hb Red

Circuit A Hot Ha Black Circuit A Hot Ha Black

N H N H N H N H N H N H N H N H
G G G G G G G G

a bi ci d a b c dn

1 general purpose + 3 isolated circuits 4 general purpose circuits


01/2011
WARNING: RISK OF FIRE OR ELECTRIC SHOCK. THIS OFFICE FURNISHING SYSTEM MAY BE CONNECTED NOTES:
TO MORE THAN ONE SOURCE OF SUPPLY. ALL SOURCES MUST BE DISCONNECTED PRIOR TO
1. NEUTRAL CONDUCTORS ARE 10 GA.
ANY SERVICING. NO SINGLE CIRCUIT MAY BE POWERED BY MORE THAN ONE SOURCE. WHITE #1 HAS BLACK LETTERING AND WHITE #2 HAS RED LETTERING.
2. GREEN/YELLOW CONDUCTOR CAN BE USED AS AN ISOLATED GROUND.
AVERTISSEMENT: CE SYSTEME PEUT ETRE RACCORDE A PLUS D'UNE SOURCE D'ALIMENTATION. TOUTES 3. CSA: 20 AMP CIRCUITS TO USE 20 AMP RECEPTACLES ONLY.
LES SOURCES D'ALIMENTATION DOIVENT ETRE COUPEES AVANT LE DEPANNAGE.

CONNECTION TO A GROUNDED RATING: 120/208V, 3-PH WYE, 60Hz, 20 AMP (CSA 15 AMP)
THREE-PHASE SYSTEM WHITE #1, WHITE #2 RATED AT 35 AMP (CSA 26 AMP) MULTIWIRE BRANCH CIRCUIT

L4 PINK PINK
L3 BLUE BLUE
WHITE #2 WHITE #2
GREEN/YELLOW GREEN/YELLOW

GREEN GREEN
WHITE #1 WHITE #1
L2 RED RED
L1 BLACK BLACK
L1 N1 G1 L2 N1 G1 L3 N1 G1 L4 N2 G2 L1 N1 G1 L2 N1 G1 L3 N2 G2 L4 N2 G2
CIRCUIT CIRCUIT CIRCUIT CIRCUIT CIRCUIT CIRCUIT CIRCUIT CIRCUIT

RECEPTACLE CONNECTIONS (LOAD) "a" "b" "c" "d" "a" "b" "c" "d"

PINK PINK
BLUE BLUE
WHITE #2 WHITE #2
GREEN/YELLOW GREEN/YELLOW

GREEN GREEN
WHITE #1 WHITE #1
RED RED
BLACK BLACK
L1 N1 G1 L2 N2 G2 L3 N2 G2 L4 N2 G2 L1 N1 G1 L2 N1 G1 L3 N1 G1 L4 N2 G1
CIRCUIT CIRCUIT CIRCUIT CIRCUIT CIRCUIT CIRCUIT CIRCUIT CIRCUIT
"a" "b" "c" "d" "a" "b" "c" "d"
WARNING: RISK OF FIRE OR ELECTRIC SHOCK. THIS OFFICE FURNISHING SYSTEM MAY BE CONNECTED NOTES:
TO MORE THAN ONE SOURCE OF SUPPLY. ALL SOURCES MUST BE DISCONNECTED PRIOR TO
1. NEUTRAL CONDUCTORS ARE 10 GA.
ANY SERVICING. NO SINGLE CIRCUIT MAY BE POWERED BY MORE THAN ONE SOURCE. WHITE #1 HAS BLACK LETTERING AND WHITE #2 HAS RED LETTERING.
2. GREEN/YELLOW CONDUCTOR CAN BE USED AS AN ISOLATED GROUND.
AVERTISSEMENT: CE SYSTEME PEUT ETRE RACCORDE A PLUS D'UNE SOURCE D'ALIMENTATION. TOUTES 3. CSA: 20 AMP CIRCUITS TO USE 20 AMP RECEPTACLES ONLY.
LES SOURCES D'ALIMENTATION DOIVENT ETRE COUPEES AVANT LE DEPANNAGE.

CONNECTION TO MULTIPLE GROUNDED RATING: 120/208V, 3-PH WYE, 60Hz, 20 AMP (CSA 15 AMP)
THREE-PHASE POWER SOURCE WHITE #1, WHITE #2 RATED AT 35 AMP (CSA 26 AMP) MULTIWIRE BRANCH CIRCUIT

"a" "b" "c" "a" "b" "a"


RECEPTACLE CONNECTIONS (LOAD) CIRCUIT CIRCUIT CIRCUIT RECEPTACLE CONNECTIONS (LOAD) CIRCUIT CIRCUIT RECEPTACLE CONNECTIONS (LOAD) CIRCUIT
L1 N1 G1 L2 N1 G1 L3 N1 G1 L1 N1 G1 L2 N1 G1 L1 N1 G1

SOURCE #1 BLACK SOURCE #1 BLACK SOURCE #1 BLACK


WHITE #1 WHITE #1 WHITE #1
GREEN
GREEN GREEN
RED RED
BLUE RED
SOURCE #2 BLUE SOURCE #2
WHITE #2
PINK WHITE #2
SOURCE #2
WHITE #2 GREEN/YELLOW
GREEN/YELLOW
BLUE
GREEN/YELLOW PINK
PINK
L4 N2 G2 L3 N2 G2 L4 N2 G2
L2 N2 G2 L3 N2 G2 L4 N2 G2
CIRCUIT CIRCUIT CIRCUIT
CIRCUIT CIRCUIT CIRCUIT
RECEPTACLE CONNECTIONS (LOAD) "d" RECEPTACLE CONNECTIONS (LOAD) "c" "d" RECEPTACLE CONNECTIONS (LOAD) "b" "c" "d"

CONNECTION TO A GROUNDED RATING: 120/240V, 1-PH, 60Hz, 20 AMP


SINGLE-PHASE SYSTEM (CSA 15 AMP) MULTIWIRE BRANCH CIRCUIT

L4 PINK
L3 BLUE
WHITE #2
GREEN/YELLOW

GREEN
WHITE #1
L2 RED
L1 BLACK
L1 N1 G1 L3 N1 G1 L2 N2 G2 L4 N2 G2
CIRCUIT CIRCUIT CIRCUIT CIRCUIT

RECEPTACLE CONNECTIONS (LOAD) "a" "c" "b" "d"


Vivo™ External Direct Connect Power Entry Installation

Parts Included: Tools Needed:

#2 Phillips Screwdriver

A Power Entry Harness

! WARNING
Risk of fire or electrical shock. This office furnishing
system may be connected to more than one source of
supply. All sources must be disconnected prior to any
servicing. No single circuit may be powered by more
than one source.

NOTICE
All electrical connections to building electrical sources
must be made by a qualified electrician according to
national, state and local electrical codes.

IMPORTANT: Save these instructions for layout changes. 1B2GHF REV B

Z Y

z
! WARNING ! WARNING
Disconnect electrical power before installation. Failure to do All electrical connections must be fully engaged and locked.
so can cause electrical shock and personal injury. Loose connections can cause fire and /or electrical shock.
3
1 Distribution Harness
Receptacle Bracket

1. Loosen 4 Screws on Cover and remove.

Screws
A
Right Hand
Cover Receptacle

2 1. Place connector end of Power Entry Harness into a Receptacle Bracket of


Distribution Harness.
2. Push into Receptacle. Make sure connection fully engages.
Port Opening

Base Cover Slot


Tab

Conduit
Slot Tab

1. Close Base Cover.


2. Determine which direction Conduit will run.
1. Feed open wire end of Power Entry Harness through Port Opening In Base Cover. 3. Align Tab on Conduit end with Slot in Body.
1B2GHF REV B

Z Y

z
5
1. Return Cover to Body.

Cover

1. Hand tighten 4 Screws on Cover as shown.


2. Hardwire open wire end of Harness into floor monument, perimeter wall or column
outlet. (Conduit connector supplied by customer.)
1B2GHF REV B

Z Y

z
CANVAS WALL BASED
10-WIRE DEDICATED NEUTRAL WIRING HARNESS
[OPTIONAL CUSTOM PRODUCT]

u Neutral 1 N1 White / Black


v Neutral 1 N1 White / Black
w Neutral 1 N1 White / Black

Neutral 2 N2 White / Red Neutral 2 N2 White / Red Neutral 2 N2 White / Red

Neutral 3 N3 White / Blue Neutral 3 N3 White / Blue Neutral 3 N3 White / Blue

Neutral 4 N4 White / Purple Neutral 4 N4 White / Purple Neutral 4 N4 White / Purple

Common Ground G1 Green or Bare Common Ground G1 Green or Bare Common Ground G1 Green or Bare

Isolated Ground G2 Green / Yellow x Isolated Ground G2 Green / Yellow Isolated Ground G2 Green / Yellow

Circuit 3 Hot H3 Blue Circuit 3 Hot H3 Blue Circuit 3 Hot H3 Blue

Circuit 2 Hot H2 Red Circuit 2 Hot H2 Red Circuit 2 Hot H2 Red

Circuit 4 Hot H4 Pink Circuit 4 Hot H4 Pink Circuit 4 Hot H4 Pink

Circuit 1 Hot H1 Black Circuit 1 Hot H1 Black Circuit 1 Hot H1 Black

N H N H N H N H N H N H N H N H N H N H N H N H

G G G G G G G G G G G G

1N 2N 3N 4N 1N 2N 3N 4G 1N 2N 3G 4G

4 general purpose circuits 3 general purpose + 1 isolated circuit 2 general purpose + 2 isolated circuit

x Neutral 1 N1 White / Black


y Neutral 1 N1 White / Black

Neutral 2 N2 White / Red Neutral 2 N2 White / Red

Neutral 3 N3 White / Blue Neutral 3 N3 White / Blue

Neutral 4 N4 White / Purple Neutral 4 N4 White / Purple

Common Ground G1 Green or Bare Common Ground G1 Green or Bare x


Isolated Ground G2 Green / Yellow Isolated Ground G2 Green / Yellow

Circuit 3 Hot H3 Blue Circuit 3 Hot H3 Blue

Circuit 2 Hot H2 Red Circuit 2 Hot H2 Red

Circuit 4 Hot H4 Pink Circuit 4 Hot H4 Pink

Circuit 1 Hot H1 Black Circuit 1 Hot H1 Black

N H N H N H N H N H N H N H N H
G G G G G G G G

1N 2G 3G 4G 1G 2G 3G 4G

1 general purpose + 3 isolated circuits 4 isolated circuits


7/9/15
Canvas / Vivo Cable Capacity

Product Pathway 4-pr. UTP Cable 4-pr. UTP Cable 4-pr. UTP Cable Fiber Optic Cable
Reference Area (sq. in.) Categories 3,5,5e Category 6 Category 6a
Cable Diameter, in. 0.22 0.25 0.35 .12 x .25
Cable Area, sq. in. 0.03801 0.04909 0.09621 0.03000
Fill Factor 40% 60% 40% 60% 40% 60% 40% 60%
Canvas Wall Based
powered FT110.xxxxJ 1.0 11 16 8 12 4 6 13 20
Base Raceway
non-powered FT110.xxxxN 6.0 63 95 49 73 25 37 80 120
Frame Vertical Cable Pass-Thru
powered FT110. 4.5 47 71 37 55 19 28 60 90
(to route cables vertically within frame,
includes two openngs) non-powered FT110. 7.0 74 110 57 86 29 44 93 140
Frame Horizontal Cable Pass-Thru
(to route cables horizontally from frame to
frame)

powered 4.5 47 71 37 55 19 28 60 90
35h or Frame (two openings) FT110.35
non-powered 6.0 63 95 49 73 25 37 80 120
42h* or 46h Frame (three openings) powered FT110.42 6.75 71 107 55 83 28 42 90 135
Components mounted on top of 42H frame may FT110.46
restrict access to top opening non-powered 9.0 95 142 73 110 37 56 120 180
53h* or 57h Frame ( four openings) powered FT110.53 9.0 95 142 73 110 37 56 120 180
Components mounted on top of 53H frame may FT110.57
restrict access to top opening non-powered 12.0 126 189 98 147 50 75 160 240
powered 11.25 118 178 92 138 47 70 150 225
68h Frame (five openings) FT110.68
non-powered 15.0 158 237 122 183 62 94 200 300
powered 13.5 142 213 110 165 56 84 180 270
79h Frame (six openings) FT110.79
non-powered 18.0 189 284 147 220 75 112 240 360
Top Channel FT110. 3.0 32 47 24 37 12 19 40 60
Cable Tray FT193. 4.67 49 74 38 57 19 29 62 93
powered FT142. 8.9 94 140 73 109 37 56 119 178
Ceiling Entry, End of Run
non-powered FT142. 10.1 106 159 82 123 42 63 135 202
powered FT143 3.0 32 47 24 37 12 19 40 60
Ceiling Entry, Connector
non-powered FT143 4.25 45 67 35 52 18 27 57 85
Top Channel, Thin-Profile Stacking Window FT187 1.0 11 16 8 12 4 6 13 20

8/2/2015
Canvas Data Channel Locations
(46” Frame Shown)

top channel
height above floor

32”
worksurface

21”

10”

3”

data channel

electrical receptacle location


data faceplate location
Canvas Power & Data Locations
(46” high frame shown)
approximate height above floor

electrical data
receptacle faceplate

39”
37”
32” 33”
worksurface

21”
19”

10”

3” 3”

electrical receptacle location


data faceplate location
Canvas Wall Data Faceplate Compatibility
❶ ❷

TIA/EIA-569-B TIA/EIA-569-B
NEMA-equivalent Opening Furniture-size Opening
Standard Screw Mount Snap-in Mount
Single-Gang

Opening Dimensions: 2.92"w x 1.882"h 2.70"w x 1.37"h


Accepts G1189.A Reducer
Accepts G1189.B Extender
Accepts Canvas X1313 Extender

Applications: Canvas (Wall Based, Beam and Dock) G1189.A Reducer


Standard product

Note: Used in Canvas Wall Can only be used


Base & Tile Locations in combination with
G1189A Reducer

Connector Series / Color


Manufacturer Style Model No. Ports Model No. Ports Options

AMP Raised 557505-x 2 -1 = Almond


(Tyco) 557502-x 4 -2 = Black
Note: 'x' = color 558088-x 4 -3 = White
557691-x 6 -4 = Gray

Flush 569084-x 2 1375288-x 4 -1, -2, -3, -4


569086-x 4 -1, -2, -3, -4
569088-x 6 -1, -2, -3, -4

Angled 406185-x 4 -1, -2, -3, -4

Flush 558106-x 2 -1, -2, -4 only


558107-x 3 -1, -2, -4 only
http://www.te.com

Connector Color
Manufacturer Style Model No. Ports Model No. Ports Options

Systimax Flush M12L-xxx 2 M13C-xxx 3 -003 = Black


(Commscope) M13L-xxx 3 M13CLS-xxx 3 -245 = Brown
M14L-xxx 4 -246 = Ivory
Note: 'xxx' = color M16L-xxx 6 -262 = White
-270 = Gray
http://www.commscope.com/systimax/eng/index.html

Connector Color
Manufacturer Style Model No. Ports Model No. Ports Options

Panduit Horiz CFPH2xx 2 CFFP4xx 4 IW=Off White


CFPH4xx 4 CFFPL4xx 4 EI=Elec Ivory
Note: 'xx' = color CFPHSL4xx 4 CFFPA2xx 2 WH=White
CFFPE3xx 3
Vert CFPL2xx 2 CFFPLA4xx 4 IG=Lt. Grey
CFPL3xx 3 UICFFP4xx 4
CFPL4xx 4
CFPL6xx 6 BL=Black
http://www.panduit.com CFPSL2xx 2
CFPSL4xx 4
Connector Color
Manufacturer Style Model No. Ports Model No. Ports Options

Siemon Horiz
MAX Series MX-HFP-01-xx 1 MX-MFP-xx** 4 01=Black
MX-HFP-02-xx 2 (** not avail in colors 02 or 80) 02=White
MX-HFP-03-xx 3 04=Gray
MX-HFP-04-xx 4 20=Ivory
80=Lt Ivory
CT Series CT2-HFP-xx 2* CT-MFP-xx** 2
(** not avail in colors 02 or 80)
Note: 'xx' = color Vert
MAX Series MX-FP-S-01-xx 1
MX-FP-S-02-xx 2
MF-FP-S-03-xx 3
http://www.siemon.com MF-FP-S-04-xx 4
MF-FP-S-06-xx 6

CT Series CT2-FP-xx 2* * Number of ports when using 2-port CT co


CT4-FP-xx 4*
Canvas Wall Data Faceplate Compatibility
❶ ❷

TIA/EIA-569-B TIA/EIA-569-B
NEMA-equivalent Opening Furniture-size Opening
Standard Screw Mount Snap-in Mount
Single-Gang

Opening Dimensions: 2.92"w x 1.882"h 2.70"w x 1.37"h


Accepts G1189.A Reducer
Accepts G1189.B Extender
Accepts Canvas X1313 Extender

Applications: Canvas (Wall Based, Beam and Dock) G1189.A Reducer


Standard product

Note: Used in Canvas Wall Can only be used


Base & Tile Locations in combination with
G1189A Reducer

Connector Color
Manufacturer Style Model No. Ports Model No. Ports Options

Leviton Angled 41081-2xP 2 49910-Sx2 2 I=Ivory


41081-3xP 3 49910-Sx4 4 W=White
Note: 'x' = color 41081-4xP 4 49910-Ex4 4 G=Grey
41081-6xP 6 B=Brown
E=Black
Angled w/ID 42081-2xS 2 A=Almond
42081-3xS 3
42081-4xS 4
42081-6xS 6

Snap-in 49910-Hx2 2
http://www.leviton.com 49910-Hx4 4

Connector Color
Manufacturer Style Model No. Ports Model No. Ports Options

Hubbell Flush IFP11xx 1 FMPS12B 2 (except as noted)


IFP12xx 2 FMPS12BVD 2
Note: 'xx' = color IFP13xx 3 FMPS13B 3 BK=Black
IFP14xx 4 FM5E4A 4 EI=Electrical Ivory
IFP16xx 6 FM5E4I 4 GY-Gray
(Black) OW=Office White
Raised, IMF1xx Up to 6 TI=Telco Ivory
modular FMPS12G 2 W=White
FMPS12GVD 2
Angled AFP14xx 4 FMPS13G 3
www.hubbell-premise.com (Gray)

Connector Color
Manufacturer Style Model No. Ports Model No. Ports Options

Ortronics Trac Jack 40300549-xx 1 40700071-xx 3 all colors not available


40300548-xx 2 & 42100009-xx flush on every model number
Note: 'xx' = color 40300547-xx 3 40700072-xx 3
all colors not available 40300546-xx 4 & 42100009-xx 0.625 deep 00=Black
on every model number 40300545-xx 6 40700073-xx 3 88=Cloud White
& 42100009-xx 1.0 deep 99- Wiremold Ivory
40300633-xx 4 78=Wiremold Dark Grey
1.5 deep 68=Wiremold Light Grey
no code=Fog White
Series II 40300158-xx 6 40300167-xx 2
http://www.ortronics.com/ (Black std)
Cabling can be routed
vertically or horizontally
every 11” of panel height

When power harnesses


are not present
interior is unobstructed

Drawing illustrating
all potential power
and data locations

POTENTIAL CANVAS POWER & DATA LOCATIONS


32 Cat 6a cables Grommets are used
fit in EACH data opening to protect cabling
Even the closest cable
routing path is more
than 6” from the
electrical harness

The cabling is
separated from
the electrical by a
grounded metal frame

A single electrical harness


in the base can supply the
required power needs
90 degree corners
provide a minimum
of 3” bend radius
32 additional Cat 6a cables
can be routed in each
data opening plus 27 more
in the top channel

55 Cat 6a cables can enter An optional cable tray


directly off the column can be used to
and into the base support cable bundle

8
Single-gang faceplate Back view of faceplate
in lower tile in lower tile

Top view of
shielded data jack termination

3” of rear clearance available

Any standard sized single-gang


faceplate can be accomodated

You might also like